Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Improvement of the predicted aural detection code ICHIN (I Can Hear It Now)

Acoustic tests were conducted to study the far-field sound pressure levels and aural detection ranges associated with a Sikorsky S-76A helicopter in straight and level flight at various advancing blade tip Mach numbers. The flight altitude was nominally 150 meters above ground level. This paper compares the normalized predicted aural detection distances, based on the measured far-field sound pressure levels, to the normalized measured aural detection distances obtained from sound jury response measurements obtained during the same test. Both unmodified and modified versions of the prediction code ICHIN-6 (I Can Hear It Now) were used to produce the results for this study.

Mueller, Arnold W.↗

A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation

A system for wirelessly measuring the volume of fluid in tanks at non-horizontal orientation is predicated upon two technologies developed at Langley Research Center. The first is a magnetic field response recorder that powers and interrogates magnetic field response sensors [ Magnetic Field Response Measurement Acquisition System, (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28]. Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields and when electrically active respond with their own magnetic fields whose attributes are dependent upon the magnitude of the physical quantity being measured. The response recorder facilitates the use of the second technology, which is a magnetic field response fluid-level sensor ["Wireless Fluid- Level Sensors for Harsh Environments," (LAR-17155), NASA Tech Briefs, Vol. 33, No. 4 (April 2009), page 30]. The method for powering and interrogating the sensors allows them to be completely encased in materials (Fig. 1) that are chemically resilient to the fluid being measured, thereby facilitating measurement of substances (e.g., acids, petroleum, cryogenic, caustic, and the like) that would normally destroy electronic circuitry. When the sensors are encapsulated, no fluid (or fluid vapor) is exposed to any electrical component of the measurement system. There is no direct electrical line from the vehicle or plant power into a fuel container. The means of interrogating and powering the sensors can be completely physically and electrically isolated from the fuel and vapors by placing the sensor on the other side of an electrically non-conductive bulkhead (Fig. 2). These features prevent the interrogation system and its electrical components from becoming an ignition source.

Woodward, Stanley E.↗

Space Station Freedom: Dynamic instrumentation for a large space structure

A proposed approach called Modal Identification Experiment (MIE) for obtaining on-orbit dynamic response measurements on Space Station Freedom, the first of a family of large, flexible space structures is discussed. The Phase 2 conceptual design study which provides a conceptual design of a proposed measurement system and an experimental protocol for inobstrusively collecting dynamic response data critical to characterizing important vibration modes of Space Station Freedom were recently concluded. The case for conducting such a measurement program is presented and the specific MIE objectives that were identified, are listed. The sequence of discrete Space Station Freedom assembly configurations is described, and the Phase 2 conceptual design of the experiment and instrumentation system are defined. In addition, a plan to utilize a space station hydrid scale model in laboratory simulations as part of the design process are discussed.

Raney, John P.↗

Measurement of Device Parameters Using Image Recovery Techniques in Large-Scale IC Devices

Devices that respond to radiation on a cell level will produce histograms showing the relative frequency of cell damage as a function of damage. The measured distribution is the convolution of distributions from radiation responses, measurement noise, and manufacturing parameters. A method of extracting device characteristics and parameters from measured distributions via mathematical and image subtraction techniques is described.

radiation↗

Experiment M-131 - Human vestibular function.

The purpose of the M-131 experiment is to measure responses in astronauts throughout orbital flight that reflect vestibular function and compare them with measurements made before and after flight. Three subtasks require measurement of (1) susceptibility to motion sickness, (2) thresholds of response to stimulation of the semicircular canals, and (3) space perception, viz, visual and nonvisual localization, using external spacecraft and internal morphological frames of reference. Four astronauts will be available for all measurements in Skylab 2 and 3 and two additional astronauts for only the 'static' measurements during the flights.

Miller, E. F., II↗

Evaluation of human response to structural vibration induced by sonic boom

This paper addresses the topic of building vibration response to sonic boom and the evaluation of the associated human response to this vibration. The paper reexamines some of the issues addressed in the previous extensive coverage of the topic, primarily by NASA, and attempts to offer a fresh viewpoint for some of the problems that may assist in reassessing the potential impact of sonic boom over populated areas. The topics addressed are: (1) human response to vibration; (2) criteria for, and acoustic signature of rattle; (3) structural response to shaped booms, including definition of two new descriptors for assessing the structural response to sonic boom; and (4) a detailed review of the previous NASA/FAA Sonic Boom Test Program involving structural response measurements at Edwards AFB and an initial estimate of structural response to sonic booms from possible high speed civil transport configurations. Finally, these estimated vibration responses are shown to be substantially greater than the human response and rattle criteria developed earlier.

Sutherland, L. C.↗

Measurement of frequency response in short thermocouple wires

Experimental measurements are made for the steady-state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 percent with the theoretical predictions of Fralick and Forney (1991). This is accomplished by choosing a natural frequency omega(sub n) for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decreas the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

Measurement of frequency response in short thermocouple wires

Experimental measurements are made for the steady-state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 percent with the theoretical predictions of Fralick and Forney (1991). This is accomplished by choosing a natural frequency omega(sub n) for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decrease the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the calculation of the response of helicopters to control inputs

In the past few years, a number of studies have provided accurate flight test data for the control response of single rotor helicopters over a wide frequency range. These measured responses have been compared to theory in a number of studies. Various differences between theory and experiment appear in all of these studies. Some of these differences are examined. A quantitative explanation of one prominent difference associated with the contribution of the lag degree of freedom is provided. Areas for further investigation are suggested. The discussion is directed towards articulated rotor helicopters. Flight test data from the UH-60, CH-53, and AH-64 helicopters, much of it taken for the express purpose of evaluating the control response, correlation with theory, and the use of parameter identification methods, is considered. Results for flight conditions near hover are emphasized.

Curtiss, H. C., Jr.↗

Testing of Full Scale Flight Qualified Kevlar Composite Overwrapped Pressure Vessels

Many decades ago NASA identified a need for low-mass pressure vessels for carrying various fluids aboard rockets, spacecraft, and satellites. A pressure vessel design known as the composite overwrapped pressure vessel (COPV) was identified to provide a weight savings over traditional single-material pressure vessels typically made of metal and this technology has been in use for space flight applications since the 1970's. A typical vessel design consisted of a thin liner material, typically a metal, overwrapped with a continuous fiber yarn impregnated with epoxy. Most designs were such that the overwrapped fiber would carry a majority of load at normal operating pressures. The weight advantage for a COPV versus a traditional singlematerial pressure vessel contributed to widespread use of COPVs by NASA, the military, and industry. This technology is currently used for personal breathing supply storage, fuel storage for auto and mass transport vehicles and for various space flight and aircraft applications. The NASA Engineering and Safety Center (NESC) was recently asked to review the operation of Kevlar 2 and carbon COPVs to ensure they are safely operated on NASA space flight vehicles. A request was made to evaluate the life remaining on the Kevlar COPVs used on the Space Shuttle for helium and nitrogen storage. This paper provides a review of Kevlar COPV testing relevant to the NESC assessment. Also discussed are some key findings, observations, and recommendations that may be applicable to the COPV user community. Questions raised during the investigations have revealed the need for testing to better understand the stress rupture life and age life of COPVs. The focus of this paper is to describe burst testing of Kevlar COPVs that has been completed as a part of an the effort to evaluate the effects of ageing and shelf life on full scale COPVs. The test articles evaluated in this discussion had a diameter of 22 inches for S/N 014 and 40 inches for S/N 011. The time between manufacture and burst was 28 and 22 years. Visual inspection, shearography, heat soak thermography and borescope inspection were performed on vessel S/N 011 and all but shearography was performed on S/N 014 before they were tested and details of this work can be found in a companion paper titled, "Nondestructive Methods and Special Test Instrumentation Supporting NASA Composite Overwrapped Pressure Vessel Assessments." The vessels were instrumented so that measurements could be made to aid in the understanding of vessel response. Measurements made on the test articles included girth, boss displacement, internal volume, multiple point strain, full field strain, eddy current, acoustic emission (AE) pressure and temperature. The test article before and during burst is shown with the pattern used for digital image correlation full field strain measurement blurring as the vessel fails.

Greene, Nathanael↗

Microwave characteristics of GaAs MMIC integratable optical detectors

Interdigitated photoconductive detectors were fabricated on microwave device structures, making them easily integratable with Monolithic Microwave Integrated Circuits (MMIC). Detector responsivity as high as 2.5 A/W and an external quantum efficiency of 3.81 were measured. Response speed was nearly independent of electrode geometry, and all detectors had usable response at frequencies to 6 GHz. A small signal model of the detectors based on microwave measurements was also developed.

Claspy, Paul C.↗

Direct measurement of MPD thrust

An integrally mounted accelerometer has been used to obtain direct thrust measurements during operation of a magnetoplasmadynamic (MPD) thruster. The structural oscillations which can mask the accelerometer output have been ameliorated by stiffening the thruster to increase the lowest resonant frequency above the 1kHz region of interest. In addition, signal conditioning is used to provide a high signal-to-noise accelerometer output waveform. Impulse response measurement of the thruster frequency response function has proven to be an effective means of selecting the signal filter and estimating measurement errors. Comparison of the total impulse derived from the accelerometer output with that from a swinging arm thrust stand indicates 3 percent agreement, providing some confidence in the viability of the accelerometer thrust measurement technique.

Berg, J. M.↗

Far-infrared imaging antenna arrays

A far-infrared monolithic imaging antenna array with diffraction-limited resolution has been demonstrated. The optical system is similar to an oil-immersion microscope, except that the position of the object and the image are interchanged. The array is a series of evaporated silver bow-tie antennas of 75 nm thick, spaced at 310 microns, on a fused-quartz substrate; the bow angle of 60 deg gives an impedance of 150 ohm to match to bismuth microbolometers. The measured responsivity of the array elements is 1-2 V/W at the relatively low bias of 1 mA. Previous measurements have shown that the bolometers are 1/f noise limited up to 100 kHz and that they have a frequency response of 5 MHz. The antenna array should be adequate for far-infrared plasma interferometer measurements.

Neikirk, D. P.↗

Lanthanide thioborates, an emerging class of nonlinear optical materials, efficiently synthesized using the boron–chalcogen mixture method

Here, the Boron–Chalcogen Mixture method was used to obtain single crystals of the previously extremely difficult to synthesize lanthanide orthothioborates to investigate their structures and their structurally connected optical behavior, such as second harmonic generation. Using a combined halide and polychalcogenide flux, the BCM method yielded single crystals of LnBS 3 (Ln = La, Ce, Pr, Nd), which are isostructural and crystallize in the non-centrosymmetric space group, Pna2 1 . Second harmonic generation measurements confirmed the expectation that LaBS 3 would exhibit a strong SHG response, measured at 1.5 × KDP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗