At least 163 records · Page 9

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Feature-agnostic metabolomics for determining effective subcytotoxic doses of common pesticides in human cells

Although classical molecular biology assays can provide a measure of cellular response to chemical challenges, they rely on a single biological phenomenon to infer a broader measure of cellular metabolic response. These methods do not always afford the necessary sensitivity to answer questions of subcytotoxic effects, nor do they work for all cell types. Likewise, boutique assays such as cardiomyocyte beat rate may indirectly measure cellular metabolic response, but they too, are limited to measuring a specific biological phenomenon and are often limited to a single cell type. For these reasons, toxicological researchers need new approaches to determine metabolic changes across various doses in differing cell types, especially within the low-dose regime. Here, the data collected herein demonstrate that LC-MS/MS-based untargeted metabolomics with a feature-agnostic view of the data, combined with a suite of statistical methods including an adapted environmental threshold analysis, provides a versatile, robust, and holistic approach to directly monitoring the overall cellular metabolomic response to pesticides. When employing this method in investigating two different cell types, human cardiomyocytes and neurons, this approach revealed separate subcytotoxic metabolomic responses at doses of 0.1 and 1 µM of chlorpyrifos and carbaryl. These findings suggest that this agnostic approach to untargeted metabolomics can provide a new tool for determining effective dose by metabolomics of chemical challenges, such as pesticides, in a direct measurement of metabolomic response that is not cell type-specific or observable using traditional assays.

59 BASIC BIOLOGICAL SCIENCES↗

Systematic multi-machine analysis of the exhaust time-dependent behavior in tokamaks

The understanding of the time-scales and associated transient behavior of fusion exhaust plasmas plays a crucial role in its dynamic modeling and its control. This work presents an overview of experimental investigations of the exhaust dynamics in TCV, MAST-U, ASDEX-Upgrade, WEST, DIII-D, and JET. From the presented experiments, a clear picture arises on properties of the exhaust dynamics across machines. Particularly, we observe that the scrape-off layer equilibrates on fast time-scales ($>$ 70 Hz) and that exhaust dynamics measured in response to gas valve modulations mostly behave smoothly and linearly, with similarities across devices, across scenarios (H-mode, L-mode), injected species, and injection locations. The measurements presented have formed the basis for systematic exhaust control on the considered devices. We now present this database for the essential validation of dynamic exhaust models for reactor design and control.

control↗

Measuring calcium content in plants using NEXAFS spectroscopy

Calcium is important for the growth and development of plants. It serves crucial functions in cell wall and cell membrane structure and serves as a secondary messenger in signaling pathways relevant to nutrient and immunity responses. Thus, measuring calcium levels in plants is important for studies of plant biology and for technology development in food, agriculture, energy, and forest industries. Often, calcium in plants has been measured through techniques such as atomic absorption spectrophotometry (AAS), inductively coupled plasma–mass spectrometry (ICP-MS), and electrophysiology. These techniques, however, require large sample sizes, chemical extraction of samples or have limited spatial resolution. Here, we used near-edge X-ray absorption fine structure (NEXAFS) spectroscopy at the calcium L- and K-edges to measure the calcium to carbon mass ratio with spatial resolution in plant samples without requiring chemical extraction or large sample sizes. We demonstrate that the integrated absorbance at the calcium L-edge and the edge jump in the fluorescence yield at the calcium K-edge can be used to quantify the calcium content as the calcium mass fraction, and validate this approach with onion epidermal peels and ICP-MS. We also used NEXAFS to estimate the calcium mass ratio in hypocotyls of a model plant, Arabidopsis thaliana , which has a cell wall composition that is similar to that of onion epidermal peels. These results show that NEXAFS spectroscopy performed at the calcium edge provides an approach to quantify calcium levels within plants, which is crucial for understanding plant physiology and advancing plant-based materials.

59 BASIC BIOLOGICAL SCIENCES↗

Deterministic and Statistical Modeling of a New Thermal Breakout Technology for Measuring the Maximum Horizontal In-Situ Stress

The current state-of-the-art technology for in-situ stress measurements involves an integrated approach that combines borehole breakout observations, drilling-induced tensile fractures, and hydraulic fracturing tests (i.e., “mini-fracs”). This methodology has achieved wide application in the oil and gas industry but has several limitations that often prevent successful in-situ stress measurements. One major limitation is that breakouts do not appear in all boreholes and are generally only a natural occurrence that cannot easily be controlled. Because borehole breakouts are used to directly measure the maximum horizontal in-situ stress magnitude, the absence of borehole breakouts presents a major data gap for in-situ stress measurements. In response to this data gap, a new US Department of Energy (US DOE)-sponsored thermal breakout technology that will provide a method for thermally inducing borehole breakouts and allow the consistent measurement of the maximum horizontal stress magnitude is currently in development. This thermal breakout technology involves heating the borehole and increasing the thermoelastic compressive stress in the rock until a breakout develops, which can be directly correlated to the maximum horizontal stress magnitude. The first step in this project was an analytical modeling study of the thermal breakout process. Based on the Kirsch solution (Kirsch 1898), a deterministic and statistical analysis was performed on the pertinent parameters that influence the maximum horizontal stress calculation. As a result of the analysis, the findings indicate that the thermal breakout technology is feasible and provides improved accuracy and/or an enhanced ability to measure the maximum horizontal stress. Future work as part of this US DOE-sponsored project includes additional validation through more detailed numerical modeling, laboratory testing, and field testing of the thermal breakout technology.

58 GEOSCIENCES↗

Revisiting the Anisotropic Complex Refractive Indices of Sodium Nitrate for Interpretation of the Reflectance Spectrum of Pressed Pellets

Reflectance spectroscopy is notoriously confounding in that the measured spectral response is highly dependent upon the morphology of the sample. Fortunately, all such perturbations are neatly encoded by the complex refractive index of the sample. Herein, we seek to quantitatively model the measured infrared reflectance spectrum of a specularly flat pressed pellet sample of the birefringent compound, sodium nitrate. Single crystals of sodium nitrate were synthesized via a slow evaporation process and spectroscopically analyzed using polarization-dependent infrared single-angle reflectance spectroscopy. The anisotropic complex refractive index was measured from 7500 to 300 cm-1 (1.33 to 33.33 µm). The deduced anisotropic optical constants were found to be consistent with those previously reported. Once measured and validated, the optical constants were applied to model the pressed pellet reflectance spectrum. It was evident that an average of the anisotropic refractive indices was insufficient to account for the measured pellet reflectance. In order to account for contributions of all possible microcrystalline orientations within the pellet, the Python package PYELLI was used to calculate a basis set of orientation-dependent reflection spectra spanning the distinct ? and ? Euler rotations of the uniaxial crystal. When the population of orientations was allowed to vary freely in a spectral fit analysis, the fit-deduced orientations were tightly clustered along f = 45º, hinting at residual anisotropy in the pressed pellet sample. Conversely, an equally valid spectral fit (with marginally worse fit metric) was obtained when the population was constrained to an isotropic distribution of orientations. Subsequent non-zero cross-polarization reflectance measurements likewise suggested anisotropy in the pellet. However, both grazing incidence wide-angle x-ray scattering and scanning electron microscopy measurements revealed that the microcrystal orientations at the surface of the pressed pellet sample were isotropically distributed (and that the average crystallite size was larger than ?/10). Application of the measured complex refractive indices for modeling the reflectance spectrum of the pressed pellet, and rectification of these seemingly contradictory observations will be discussed.

Wilhelm, Michael J.↗

Measurement of the light yield response of the Gd-compatible water-based liquid scintillator with the Brookhaven one-ton testbed

The water-based liquid scintillator (WbLS) enables hybrid detection by combining scintillation and Cherenkov signals, providing superior event reconstruction capabilities compared to conventional neutrino detectors. For this work, we measured the light yield of Gd-compatible WbLS at varying concentrations from 0.35% to 1% by mass, using cosmic-ray muons in a 1-ton scale detector at Brookhaven National Laboratory. The light yield is measured as (69.2 ± 6.9) ph/MeV at 0.35% concentration, which increased to (87.3 ± 8.7) ph/MeV at 1%. These results establish a quantitative basis for optimizing future WbLS-based detectors in neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of the frequency response of a novel GaAs plasmonic terahertz detector

Previously there was reported a new type of high-speed plasmonic THz detector that can operate at room temperature. As an extension of that work, the sensitivity of the detector was investigated over a wide range of sub-THz frequencies. The measured frequency response is not purely monotonic but exhibits oscillatory behaviour with a number of maxima and minima. Our study reveals that such frequency dependence is caused by the interference of electromagnetic waves inside the detector substrate, as the frequencies of these extrema are found to be governed by the substrate thickness. We demonstrate that sensitivity of this type of detector can be optimized for the desired operating frequency within 0.06–0.7 THz spectrum by adjusting the substrate thickness. We also show that a monotonic frequency response with eliminated minima can be achieved by mounting the detector on a specially designed silicon lens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous Compensation of Third-Order Resonances at the FNAL Recycler Ring

Third-order resonance lines will have a detrimental effect on the high-intensity operation of the Recycler Ring (RR), under the current Proton Improvement Plan (PIP-II) for the Fermilab Accelerator Complex. Increasing intensity will increase space charge effects, leading to the excitation of normal and skew sextupole lines. Dedicated normal and skew sextupoles have been installed in order to mitigate the effect of these resonance lines. By measuring the response matrix of the third-order Resonance Driving Terms (RDTs) to the currents of these dedicated elements, this study shows how several resonance lines can be compensated simultaneously. Resonance compensation is experimentally verified through loss maps and emittance growth measurements using the Ion Profile Monitor (IPM) system in the Recycler.

43 PARTICLE ACCELERATORS↗

Absolute light yield of the EJ-204 plastic scintillator

The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $γ$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 ± 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Mathematical Model of the Dynamics of Cytokine Expression and Human Immune Cell Activation in Response to the Pathogen Staphylococcus aureus

Cell-based mathematical models have previously been developed to simulate the immune system in response to pathogens. Mathematical modeling papers which study the human immune response to pathogens have predicted concentrations of a variety of cells, including activated and resting macrophages, plasma cells, and antibodies. This study aims to create a comprehensive mathematical model that can predict cytokine levels in response to a gram-positive bacterium, S. aureus by coupling previous models. To accomplish this, the cytokines Tumor Necrosis Factor Alpha (TNF-α), Interleukin 6 (IL-6), Interleukin 8 (IL-8), and Interleukin 10 (IL-10) are included to quantify the relationship between cytokine release from macrophages and the concentration of the pathogen, S. aureus, ex vivo. Partial differential equations (PDEs) are used to model cellular response and ordinary differential equations (ODEs) are used to model cytokine response, and interactions between both components produce a more robust and more complete systems-level understanding of immune activation. In the coupled cellular and cytokine model outlined in this paper, a low concentration of S. aureus is used to stimulate the measured cellular response and cytokine expression. Results show that our cellular activation and cytokine expression model characterizing septic conditions can predict ex vivo mechanisms in response to gram-negative and gram-positive bacteria. Our simulations provide new insights into how the human immune system responds to infections from different pathogens. Novel applications of these insights help in the development of more powerful tools and protocols in infection biology.

60 APPLIED LIFE SCIENCES↗

High frequency impedance characteristics of a tunable microplasma device

Computational studies on high frequency impedance characteristics of a microplasma device are reported. While microplasma is ignited using a primary excitation signal, frequency response of plasma impedance is determined by a secondary high frequency probe signal with significantly lower voltage amplitude such that it does not influence the plasma parameters. Here, the computational model utilizing the drift–diffusion approximation is first validated by comparing with experimental data for microplasmas ignited at pressures ranging from 1 to 5 Torr. In spite of quantitative discrepancies, good overall agreement is obtained between the measured frequency response of impedance of the discharge. Comparisons are also presented for various plasma parameters including mean electron number density, sheath thickness, mean electron temperature, and collision frequency that were inferred from the impedance measurements. The computational model is then used to perform simulations of near-atmospheric pressure microplasmas with the probe signal frequency ranging from 3 to 20 GHz. The simulations demonstrate the presence of a resonance frequency at which the impedance vanishes. More importantly, it is shown that this resonant frequency can be tuned effectively by suitably modifying the operating parameters (gap size, pressure, and excitation voltage). The simulated impedance characteristics are used to determine the effective plasma inductance and capacitance using a non-linear fitting approach, thereby showing the dependence of these electrical parameters on the plasma operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid remodeling of the soil lipidome in response to a drying-rewetting event

Abstract Background Microbiomes contribute to multiple ecosystem services by transforming organic matter in the soil. Extreme shifts in the environment, such as drying-rewetting cycles during drought, can impact the microbial metabolism of organic matter by altering microbial physiology and function. These physiological responses are mediated in part by lipids that are responsible for regulating interactions between cells and the environment. Despite this critical role in regulating the microbial response to stress, little is known about microbial lipids and metabolites in the soil or how they influence phenotypes that are expressed under drying-rewetting cycles. To address this knowledge gap, we conducted a soil incubation experiment to simulate soil drying during a summer drought of an arid grassland, then measured the response of the soil lipidome and metabolome during the first 3 h after wet-up. Results Reduced nutrient access during soil drying incurred a replacement of membrane phospholipids, resulting in a diminished abundance of multiple phosphorus-rich membrane lipids. The hot and dry conditions increased the prevalence of sphingolipids and lipids containing long-chain polyunsaturated fatty acids, both of which are associated with heat and osmotic stress-mitigating properties in fungi. This novel finding suggests that lipids commonly present in eukaryotes such as fungi may play a significant role in supporting community resilience displayed by arid land soil microbiomes during drought. As early as 10 min after rewetting dry soil, distinct changes were observed in several lipids that had bacterial signatures including a rapid increase in the abundance of glycerophospholipids with saturated and short fatty acid chains, prototypical of bacterial membrane lipids. Polar metabolites including disaccharides, nucleic acids, organic acids, inositols, and amino acids also increased in abundance upon rewetting. This rapid metabolic reactivation and growth after rewetting coincided with an increase in the relative abundance of firmicutes, suggesting that members of this phylum were positively impacted by rewetting. Conclusions Our study revealed specific changes in lipids and metabolites that are indicative of stress adaptation, substrate use, and cellular recovery during soil drying and subsequent rewetting. The drought-induced nutrient limitation was reflected in the lipidome and polar metabolome, both of which rapidly shifted (within hours) upon rewet. Reduced nutrient access in dry soil caused the replacement of glycerophospholipids with phosphorus-free lipids and impeded resource-expensive osmolyte accumulation. Elevated levels of ceramides and lipids with long-chain polyunsaturated fatty acids in dry soil suggest that lipids likely play an important role in the drought tolerance of microbial taxa capable of synthesizing these lipids. An increasing abundance of bacterial glycerophospholipids and triacylglycerols with fatty acids typical of bacteria and polar metabolites suggest a metabolic recovery in representative bacteria once the environmental conditions are conducive for growth. These results underscore the importance of the soil lipidome as a robust indicator of microbial community responses, especially at the short time scales of cell-environment reactions.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity calibration of a Carestream HPX-1 image plate scanner

There is a need to measure the sensitivity of the image plate scanners used to scan Z shot data. The Carestream HPX-1 image plate scanner was tested, and its performance was characterized to determine the system sensitivity in terms of signal per incident photon as a function of x-ray energy. A Manson source was used to simultaneously expose an Amptek x-ray multi-channel analyzer and image plates, allowing for a comparison of the counts as a function of energy to the signal recorded on the image plates. NIST-certified radioactive sources were used to assign an absolute sensitivity. Results indicate that the HPX-1 scanner response matches the shape of the modeled response, allowing for absolute scaling using NIST-certified radioisotope sources. The HPX-1 scanner shows a stable response with measurements taken over one week. In contrast, the sensitivity of the DITABIS scanner was characterized using the same approach, but it exhibits changes in its response that varied by more than 50% over the span of 4 days.

42 ENGINEERING↗

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗

Temperature-responsive smart tracers for field-measurement of inter-well thermal evolution: Heterogeneous kinetics and field demonstration

Temperature-responsive smart tracers enable advanced warning of a “premature thermal breakthrough” and may therefore improve reservoir management and reduce financial risk. A successful calculation of inter-well fluid temperatures requires that temperature-dependent kinetics are known, which typically result from homogeneous batch reactor experiments. However, recent meso-scale field experiments at the Altona Field Laboratory involving fluid flow in a discretely-fractured reservoir suggest that silica-fluid interfaces may accelerate hydrolysis kinetics. Here, the Arrhenius parameters of phenyl acetate hydrolysis are investigated under heterogeneous reaction conditions in packed-bed column experiments. The breakthrough curve of the reaction product is compared to an inert reference tracer (carbon-cored nanoparticles). Temperatures experienced during field testing ranging from 10 to 40 °C were studied using a phosphate buffer solution to maintain a near-neutral pH, as found in the reservoir. The empirically-determined pre-exponential factor and activation energy values are subsequently used in a first-order kinetic model to improve calculations of effective reservoir temperatures for these meso-scale field tests. Here, the results suggest that hydrolysis reactions can directly monitor inter-well reservoir temperatures, but only if the influence of solid-fluid interactions are carefully accounted for.

15 GEOTHERMAL ENERGY↗

24.1.3.4 Upgraded Fixed Energy Response Function Analysis with Multiple Efficiencies (FRAM) Software for U/Pu/MOX Mass Measurements

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr 3 ) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗