Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

On Approaching the Ultimate Limits of Communication Using a Photon-Counting Detector

Coherent states achieve the Holevo capacity of a pure-loss channel when paired with an optimal measurement, but a physical realization of this measurement scheme is as of yet unknown, and it is also likely to be of high complexity. In this paper, we focus on the photon-counting measurement and study the photon and dimensional efficiencies attainable with modulations over classical- and nonclassical-state alphabets. We analyze two binary modulation architectures that improve upon the dimensional versus photon efficiency tradeoff achievable with the state-of-the-art coherent-state on-off keying modulation. We show that at high photon efficiency these architectures achieve an efficiency tradeoff that differs from the best possible tradeoff--determined by the Holevo capacity--by only a constant factor. The first architecture we analyze is a coherent-state transmitter that relies on feedback from the receiver to control the transmitted energy. The second architecture uses a single-photon number-state source.

photon-counting measurement↗

Approaching the Ultimate Limits of Communication Efficiency with a Photon-Counting Detector

Coherent states achieve the Holevo capacity of a pure-loss channel when paired with an optimal measurement, but a physical realization of this measurement is as of yet unknown, and it is also likely to be of high complexity. In this paper, we focus on the photon-counting measurement and study the photon and dimensional efficiencies attainable with modulations over classical- and nonclassical-state alphabets. We first review the state-of-the-art coherent on-off-keying (OOK) with a photoncounting measurement, illustrating its asymptotic inefficiency relative to the Holevo limit. We show that a commonly made Poisson approximation in thermal noise leads to unbounded photon information efficiencies, violating the conjectured Holevo limit. We analyze two binary-modulation architectures that improve upon the dimensional versus photon efficiency tradeoff achievable with conventional OOK. We show that at high photon efficiency these architectures achieve an efficiency tradeoff that differs from the best possible tradeoff--determined by the Holevo capacity--by only a constant factor. The first architecture we analyze is a coherent-state transmitter that relies on feedback from the receiver to control the transmitted energy. The second architecture uses a single-photon number-state source.

thermal noises↗

µRWELL-PICOSEC: The Development of Fast Timing Resistive Micro-WELL Detector Technology.

We present the development of a new concept of fast timing gaseous detector, the ?RWELL-PICOSEC detector based on Resistive Micro-Well (?RWELL) technology to provide timing resolution in the tens of picosecond range for application as time-of-flight (TOF) technology in the particle physics and medical instrumentation fields. The ?RWELL-PICOSEC technology combined a Cerenkov radiator for the generation of Cerenkov photons from high energy charged particles, a photocathode for the conversion of the produced photons into primary electrons and the ?RWELL foil for the multiplication of the electron to produce large signal on pad segmentation readout. The proof of concept of ?RWELL-PICOSEC is demonstrated with a small single-channel prototype and preliminary timing performance of 90 ps has been measured. Optimization study the amplification structure of ?RWELL-PICOSEC for the improvement of timing resolution is discussed and results on timing performance studies in beam at CERN are presented. The development of large area (100 mm × 100 mm) ?RWELL-PICOSEC and associated multichannel fast readout electronics and data acquisition system are also reported

Weisenberger, Andrew↗

Optimizing 4d Emittance Measurements Using the Pinhole Scan Technique

Accurate measurement of electron beam emittance is essential for optimizing high-brightness electron sources. The Pinhole Scan Technique measures the 4D phase space and hence the emittance by measuring the beam profile after clipping the beam using a pinhole followed by a drift section and then scanning the beam over the pinhole. This technique has been implemented in low energy (< 200 keV) beamlines at both Cornell University and Arizona State University. However, the technique poses several practical challenges. In this work, we analyze and address key issues affecting the 4D phase space and emittance measurements using this technique. We identify and investigate sources of inaccuracies like the pinhole aspect ratio, beam divergence, position-momentum correlations in the phase space, and the point-spread-function of the detector and suggest techniques to minimize them. Our findings offer a pathway to more accurate 4D phase space characterization in advanced electron beam systems.

42 ENGINEERING↗

High-speed 3D shape measurement using the optimized composite fringe patterns and stereo-assisted structured light system

In this study, we propose a high-speed 3D shape measurement technique based on the optimized composite fringe patterns and stereo-assisted structured light system. Stereo phase unwrapping, as a new-fashioned method for absolute phase retrieval based on the multi-view geometric constraints, can eliminate the phase ambiguities and obtain a continuous phase map without projecting any additional patterns. However, in order to ensure the stability of phase unwrapping, the period of fringe is generally around 20, which limits the accuracy of 3D measurement. To solve this problem, we develop an optimized method for designing the composite pattern, in which the speckle pattern is embedded into the conventional 4-step phase-shifting fringe patterns without compromising the fringe modulation, and thus the phase measurement accuracy. We also present a simple and effective evaluation criterion for the correlation quality of the designed speckle pattern in order to improve the matching accuracy significantly. When the embedded speckle pattern is demodulated, the periodic ambiguities in the wrapped phase can be eliminated by combining the adaptive window image correlation with geometry constraint. Finally, some mismatched regions are further corrected based on the proposed regional diffusion compensation technique (RDC). These proposed techniques constitute a complete computational framework that allows to effectively recover an accurate, unambiguous, and distortion-free 3D point cloud with only 4 projected patterns. Experimental results verify that our method can achieve high-speed, high-accuracy, robust 3D shape measurement with dense (64-period) fringe patterns at 5000 frames per second.

42 ENGINEERING↗

An Adaptive Optimizer for Measurement-Frugal Variational Algorithms

Variational hybrid quantum-classical algorithms (VHQCAs) have the potential to be useful in the era of near-term quantum computing. However, recently there has been concern regarding the number of measurements needed for convergence of VHQCAs. Here, we address this concern by investigating the classical optimizer in VHQCAs. We introduce a novel optimizer called individual Coupled Adaptive Number of Shots (iCANS). This adaptive optimizer frugally selects the number of measurements (i.e., number of shots) both for a given iteration and for a given partial derivative in a stochastic gradient descent. We numerically simulate the performance of iCANS for the variational quantum eigensolver and for variational quantum compiling, with and without noise. In all cases, and especially in the noisy case, iCANS tends to out-perform state-of-the-art optimizers for VHQCAs. We therefore believe this adaptive optimizer will be useful for realistic VHQCA implementations, where the number of measurements is limited.

97 MATHEMATICS AND COMPUTING↗

Optimization of Simultaneous Measurement for Variational Quantum Eigensolver Applications

Variational quantum eigensolver (VQE) is a promising algorithm suitable for near-term quantum computers. VQE aims to approximate solutions to exponentially-sized optimization problems by executing a polynomial number of quantum sub-problems. However, the number of subproblems scales as N-4 for typical problems of interest-a daunting growth rate that poses a serious limitation for emerging applications such as quantum computational chemistry. We mitigate this issue by exploiting the simultaneous measurability of subproblems corresponding to commuting terms. Our technique transpiles VQE instances into a format optimized for simultaneous measurement, ultimately yielding 8-30x lower cost. Our work also encompasses a synthesis tool for compiling simultaneous measurement circuits with minimal overhead. We demonstrate experimental validation of our techniques by estimating the ground state energy of deuteron with a quantum computer. We also investigate the underlying statistics of simultaneous measurement and devise an adaptive strategy for mitigating harmful covariance terms.

quantum computing↗

The CU 2-D-MAX-DOAS instrument – Part 2: Raman scattering probability measurements and retrieval of aerosol optical properties

Abstract. The multiannual global mean of aerosol optical depth at 550 nm (AOD550) over land is ∼ 0.19, and that over oceans is ∼ 0.13. About 45 % of the Earth surface shows AOD550 smaller than 0.1. There is a need for measurement techniques that are optimized to measure aerosol optical properties under low AOD conditions. We present an inherently calibrated retrieval (i.e., no need for radiance calibration) to simultaneously measure AOD and the aerosol phase function parameter, g, based on measurements of azimuth distributions of the Raman scattering probability (RSP), the near-absolute rotational Raman scattering (RRS) intensity. We employ radiative transfer model simulations to show that for solar azimuth RSP measurements at solar elevation and solar zenith angle (SZA) smaller than 80°, RSP is insensitive to the vertical distribution of aerosols and maximally sensitive to changes in AOD and g under near-molecular scattering conditions. The University of Colorado two-dimensional Multi-AXis Differential Optical Absorption Spectroscopy (CU 2-D-MAX-DOAS) instrument was deployed as part of the Two Column Aerosol Project (TCAP) at Cape Cod, MA, during the summer of 2012 to measure direct sun spectra and RSP from scattered light spectra at solar relative azimuth angles (SRAAs) between 5 and 170°. During two case study days with (1) high aerosol load (17 July, 0.3 < AOD430 < 0.6) and (2) near-molecular scattering conditions (22 July, AOD430 < 0.13) we compare RSP-based retrievals of AOD430 and g with data from a co-located CIMEL sun photometer, Multi-Filter Rotating Shadowband Radiometer (MFRSR), and an airborne High Spectral Resolution Lidar (HSRL-2). The average difference (relative to DOAS) for AOD430 is +0.012 ± 0.023 (CIMEL), −0.012 ± 0.024 (MFRSR), −0.011 ± 0.014 (HSRL-2), and +0.023 ± 0.013 (CIMELAOD − MFRSRAOD) and yields the following expressions for correlations between different instruments: DOASAOD = −(0.019 ± 0.006) + (1.03 ± 0.02) × CIMELAOD (R2 = 0.98), DOASAOD = −(0.006 ± 0.005) + (1.08 ± 0.02) × MFRSRAOD (R2 = 0.98), and CIMELAOD = (0.013 ± 0.004) + (1.05 ± 0.01) × MFRSRAOD (R2 = 0.99). The average g measured by DOAS on both days was 0.66 ± 0.03, with a difference of 0.014 ± 0.05 compared to CIMEL. Active steps to minimize the error in the RSP help to reduce the uncertainty in retrievals of AOD and g. As AOD decreases and SZA increases, the RSP signal-to-noise ratio increases. At AOD430 ∼ 0.4 and 0.10 the absolute AOD errors are ∼ 0.014 and 0.003 at 70° SZA and 0.02 and 0.004 at 35° SZA. Inherently calibrated, precise AOD and g measurements are useful to better characterize the aerosol direct effect in urban polluted and remote pristine environments.

54 ENVIRONMENTAL SCIENCES↗

A method to calibrate measurement instruments to optimize the spectrometer optics for experiment E94-107 at JLab

A method to calibrate measurement instruments through the fulfillment of physical laws is described. This method is particularly well suited to determine and/or improve magnetic spectrometer optics databases as well as to establish the best resolution achievable with them. Here, this method was applied to obtain the best resolution achievable in the excitation and binding energy spectra of several hypernuclei produced in the experiment E94-107 performed at JLab, allowing us to obtain sub-MeV resolutions.

47 OTHER INSTRUMENTATION↗

Optimally configuring a measurement system to detect diversions from a nuclear fuel cycle

The civilian nuclear fuel cycle is an industrial process that produces electrical power from the nuclear fission of uranium. Using a measurement system to accurately account for nuclear material, such as uranium, in a fuel cycle is important because of the possible loss or diversion of this potentially dangerous material. A measurement system is defined by a set of measurement methods, or “devices,” used to account for material flows and inventory values at specific locations in the fuel cycle. Here, we develop a simulation-optimization algorithm and an integer-programming model to find the best, or near-best, resource-limited measurement system with a high degree of confidence. The simulation-optimization algorithm minimizes a weighted sum of false positive and false negative diversion-detection probabilities while accounting for material quantities and measurement errors across a finite, discrete time horizon in hypothetical non-diversion and diversion contexts. In each time period, the estimated cumulative material unaccounted for is compared to a fixed or an optimized threshold value to assess if a “significant amount of material” is lost from a measurement system. The integer-programming model minimizes the population variance of the estimated material loss, i.e., material unaccounted for, in a measurement system. We analyze three potential problems in nuclear fuel cycle measurement systems: (i) given location-dependent device precisions, find the configuration of n devices at n locations ( n = 3) that gives the lowest corresponding objective values using the simulation-optimization algorithm and integer-programming model, (ii) find the location at which improving device precision reduces objective values the most using the simulation-optimization algorithm, and determine the effect of measurement frequency on measurement system configurations and objective values using the simulation-optimization algorithm. We obtain comparable results for each problem at least an order of magnitude faster than existing methods do. Using an optimized, rather than fixed, detection threshold in the simulation-optimization algorithm reduces the weighted sum of false positive and false negative probabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Maximal Isometric Force to Determine the Optimal Load for Measuring Dynamic Muscle Power

Maximal power output occurs when subjects perform ballistic exercises using loads of ~30-50% of one-repetition maximum (1-RM). However, performing 1-RM testing prior to power measurement requires considerable time, especially when testing involves multiple exercises. Maximal isometric force (MIF), which requires substantially less time to measure than 1-RM, might be an acceptable alternative for determining the optimal load for power testing. PURPOSE: To determine the optimal load based on MIF for maximizing dynamic power output during leg press and bench press exercises. METHODS: Twenty healthy volunteers (12 men and 8 women; mean +/- SD age: 31+/-6 y; body mass: 72 +/- 15 kg) performed isometric leg press and bench press movements, during which MIF was measured using force plates. Subsequently, subjects performed ballistic leg press and bench press exercises using loads corresponding to 20%, 30%, 40%, 50%, and 60% of MIF presented in randomized order. Maximal instantaneous power was calculated during the ballistic exercise tests using force plates and position transducers. Repeated-measures ANOVA and Fisher LSD post hoc tests were used to determine the load(s) that elicited maximal power output. RESULTS: For the leg press power test, six subjects were unable to be tested at 20% and 30% MIF because these loads were less than the lightest possible load (i.e., the weight of the unloaded leg press sled assembly [31.4 kg]). For the bench press power test, five subjects were unable to be tested at 20% MIF because these loads were less than the weight of the unloaded aluminum bar (i.e., 11.4 kg). Therefore, these loads were excluded from analysis. A trend (p = 0.07) for a main effect of load existed for the leg press exercise, indicating that the 40% MIF load tended to elicit greater power output than the 60% MIF load (effect size = 0.38). A significant (p . 0.05) main effect of load existed for the bench press exercise; post hoc analysis indicated that the effect of load on power output was: 30% > 40% > 50% = 60%. CONCLUSION: Loads of 40% and 30% of MIF elicit maximal power output during dynamic leg presses and bench presses, respectively. These findings are similar to those obtained when loading is based on 1-RM.

Spiering, Barry A.↗

Optimal weights for measuring redshift space distortions in multitracer galaxy catalogues

Since the volume accessible to galaxy surveys is fundamentally limited, it is extremely important to analyse available data in the most optimal fashion. One way of enhancing the cosmological information extracted from the clustering of galaxies is by weighting the galaxy field. The most widely used weighting schemes assign weights to galaxies based on the average local density in the region (FKP weights) and their bias with respect to the dark matter field (PVP weights). They are designed to minimize the fractional variance of the galaxy power-spectrum. We demonstrate that the currently used bias dependent weighting scheme can be further optimized for specific cosmological parameters. We develop a procedure for computing the optimal weights and test them against mock catalogues for which the values of all fitting parameters, as well as the input power-spectrum are known. In this work, we show that by applying these weights to the joint power-spectrum of emission line galaxies and luminous red galaxies from the Dark Energy Spectroscopic Instrument survey, the variance in the measured growth rate parameter can be reduced by as much as 36 per cent.

79 ASTRONOMY AND ASTROPHYSICS↗

On the Optimal Transport of Semiclassical Measures

In this paper we study the optimal transport of projected semiclassical measures on the flat torus which are linked to a class of Schrödinger’s type equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal two-copy discrimination of quantum measurements

We investigate optimal discrimination between two projective quantum measurements on a single qubit. We consider a scenario where the measurement that should be identified can be performed twice and we show that adaptive discrimination strategy, entangled probe states, and feed forward all help to increase the probability of correct identification of the measurement. We also experimentally demonstrate the studied discrimination strategies and test their performance. The employed experimental setup involves projective measurements on polarization states of single photons and preparation of required probe two-photon polarization states by the process of spontaneous parametric downconversion and passive linear optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment and Optimization of Lidar Measurement Availability for Wind Turbine Control: Preprint

Turbine-mounted lidars provide preview measurements of the incoming wind field. By reducing loads on critical components and increasing the potential power extracted from the wind, the performance of wind turbine controllers can be improved [2]. As a result, integrating a light detection and ranging (lidar) system has the potential to lower the cost of wind energy. This paper presents an evaluation of turbine-mounted lidar availability. Availability is a metric which measures the proportion of time the lidar is producing controller-usable data, and is essential when a wind turbine controller relies on a lidar. To accomplish this, researchers from Avent Lidar Technology and the National Renewable Energy Laboratory first assessed and modeled the effect of extreme atmospheric events. This shows how a multirange lidar delivers measurements for a wide variety of conditions. Second, by using a theoretical approach and conducting an analysis of field feedback, we investigated the effects of the lidar setup on the wind turbine. This helps determine the optimal lidar mounting position at the back of the nacelle, and establishes a relationship between availability, turbine rpm, and lidar sampling time. Lastly, we considered the role of the wind field reconstruction strategies and the turbine controller on the definition and performance of a lidar's measurement availability.

17 WIND ENERGY↗

SU-E-I-62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

Purpose: Reducing patient dose while maintaining (or even improving) image quality is one of the foremost goals in CT imaging. To this end, we consider the feasibility of optimizing CT scan protocols in conjunction with the application of different beam-hardening filtrations and assess this augmentation through noise-power spectrum (NPS) and detector quantum efficiency (DQE) analysis. Methods: American College of Radiology (ACR) and Catphan phantoms (The Phantom Laboratory) were scanned with a 64 slice CT scanner when additional filtration of thickness and composition (e.g., copper, nickel, tantalum, titanium, and tungsten) had been applied. A MATLAB-based code was employed to calculate the image of noise NPS. The Catphan Image Owl software suite was then used to compute the modulated transfer function (MTF) responses of the scanner. The DQE for each additional filter, including the inherent filtration, was then computed from these values. Finally, CT dose index (CTDIvol) values were obtained for each applied filtration through the use of a 100 mm pencil ionization chamber and CT dose phantom. Results: NPS, MTF, and DQE values were computed for each applied filtration and compared to the reference case of inherent beam-hardening filtration only. Results showed that the NPS values were reduced between 5 and 12% compared to inherent filtration case. Additionally, CTDIvol values were reduced between 15 and 27% depending on the composition of filtration applied. However, no noticeable changes in image contrast-to-noise ratios were noted. Conclusion: The reduction in the quanta noise section of the NPS profile found in this phantom-based study is encouraging. The reduction in both noise and dose through the application of beam-hardening filters is reflected in our phantom image quality. However, further investigation is needed to ascertain the applicability of this approach to reducing patient dose while maintaining diagnostically acceptable image qualities in a clinical setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗