Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Asphaltene Adsorption onto Self-Assembled Monolayers of Mixed Aromatic

The adsorption of asphaltenes onto flat solid surfaces modified with mixed self-assembled monolayers (SAMs) of aliphatic and aromatic trichlorosilanes with varying wettabilities, aromaticities, and thicknesses is tested. The mixed SAMs are characterized by means of contact angle to assess hydrophobicity and molecular and chemical uniformity, spectroscopic ellipsometry to measure the thickness of the films, and near edge X-ray absorption fine structure (NEXAFS) spectroscopy to assess chemical and molecular composition. The molecular characteristics of the adsorbed asphaltene layer and the extent of asphaltene adsorption are determined using NEXAFS and spectroscopic ellipsometry, respectively. The SAMs are formed by depositing phenyl-, phenethyl-, butyl-, and octadecyl- trichlorosilanes from toluene solutions onto silica-coated substrates; the chemical composition and the wettability of the SAM surface is tuned systematically by varying the trichlorosilane composition in the deposition solutions. The adsorption of asphaltenes on the substrates does not correlate strongly with the SAM chemical composition. Instead, the extent of asphaltene adsorption decreases with increasing SAM thickness. This observation suggests that the leading interaction governing the adsorption of asphaltenes is their interaction with the polar silica substrate and that the chemical composition of the SAM is of secondary importance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncertainty Quantification by Monte Carlo Analysis using CFD Simulations for GEMIX Benchmark Activities

Uncertainty quantification (UQ) methods can be applied to computational fluid dynamics (CFD) simulations for determining the uncertainty bands of the simulations results. In order to determine the applicability of these different methods, simple benchmark activities have been conducted by various group for comparison. The GEMIX (Generic Mixing experiment) test facility was used to develop benchmark data for this purpose by the Paul Scherrer Institute (PSI). The facility involves the mixing of two fluids that are initially separated. One of the two fluids is water with sugar dissolved in it to create a fluid with similar fluid properties to water, except for density. The other fluid was distilled water to reduce the uncertainty in the fluid's properties. During the experiments, velocity fields and concentration measurements were acquired at several planes of interest. The velocity fields were acquired using particle image velocimetry (PIV) and concentrations of each fluid were acquired using laser induced fluorescence (LIF). The inlet velocity profiles were acquired using laser Doppler velocimetry (LDV). The activity provided the opportunity to vary turbulence models, meshing methodologies, and numerical schemes for creation of uncertainty estimates. The present study investigates the usage of a simple Monte Carlo (MC) technique for varying the inlet boundary conditions of each inlet. The velocity profiles and densities of each inlet were specifically varied based on experiment measurement uncertainty. The intent was to isolate the uncertainty due to inlet quantities and not related to meshing, numerical scheme, or turbulence models. The comparisons of experimental and simulation results were found to be reasonably accurate. Though deficiencies were identified in the modeling approach to be corrected in future works by the authors. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Reactant Mixing in a Rotating Detonation Engine Using Schlieren Imaging and Planar Laser Induced Fluorescence

A linearized version of an axial flow injector used in an air breathing rotating detonation engine (RDE) has been developed to aid in the study of reactant mixing. The test bed was designed with optical access so that a variety of qualitative and quantitative imaging techniques may be applied. Non-reacting, pure mixing studies are presented here. In this initial study high speed Schlieren video is used to understand the evolution of the flow field in time and across an operating regime analogous to its RDE counterpart. Basic flow features are identified and average flow field images are generated and used to assess how the average flow field evolves across the operating regime. Acetone-tracer planar laser induced fluorescence (PLIF) is used to generate plots of instantaneous and average molar fraction and initial data is presented here.

Duvall, James↗

Insights into determining pore size properties of ultrafiltration membranes

The selectivity of porous membranes is often characterized using solute rejection tests, where membranes are challenged with dilute aqueous solutions of neutral solutes at operating conditions that minimize concentration polarization and fouling. In single solute tests, a membrane is challenged with one molecular weight (MW) solute at a time from low to high MW. Since single solute methods are time-intensive, mixed solute tests have become more common, where a mixture of several MW solutes challenges a membrane at once. However, the presence of large solutes in a mixture increases the rejection of smaller solutes. Furthermore, there are no universally accepted operating conditions or standard methods used by membrane manufacturers or researchers for the experiments, leading to difficulty in pore size and pore characteristic comparisons. In this paper, commercial ultrafiltration membranes were challenged with single and mixed solute polyethylene glycol (PEG) and dextran aqueous solutions. First, rejection values determined using total organic carbon (TOC) and high-performance liquid chromatography (HPLC) from single solute filtration experiments are compared. Differences in rejection curves obtained by the two techniques are attributed to solute polydispersity. Mixed solute filtration experiments with binary mixtures of solutes showcased co-solute interactions, which increase with both the size and weight percent of large solute in the mixture. Mixed solute filtration experiments at varying operating conditions (i.e., stir speed and flux) were conducted to determine operating conditions that mitigate co-solute interactions. Stir speed had a minimal effect on co-solute interactions. In contrast, low flux conditions can help minimize co-solute interactions, leading to pore size distributions that closely resemble results observed in single solute filtration using narrowly dispersed solutes. Additionally, at low flux conditions, the predicted membrane pore size distributions utilizing mixed solute experiments with PEG and dextran were similar.

36 MATERIALS SCIENCE↗

Bridging the Gap Between Pure and Mixed-Gas Performance of Thin-Film Composite Membranes

This study examines the influence of cell design on mixed-gas testing with PolyActive™ TFC membranes, featuring pure-gas CO₂ permeance of 1700–3100 GPU, representative of state-of-the-art CO₂/N₂ separation membranes. By designing and 3D-printing a counter-current permeation cell with optimized flow efficiency, we achieved a 33–41% increase in mixed-gas CO₂ permeance compared to traditional cells. Additionally, a comparison of sweep-gas and vacuum permeation methods revealed that vacuum operation mitigates downstream polarization, enhancing mixed-gas CO₂ permeance by 41%. These results underscore the critical role of permeation cell design and testing methods in accurately evaluating membrane performance, with significant implications for scaling up TFC membranes and optimizing industrial processes.

3D printing↗

MULTIPHASE FLOW CONCENTRATION CHARACTERIZATION IN SLURRIES DURING PULSE JET MIXING

Obtaining real-time, in situ slurry concentration measurements during unsteady mixing can provide increased understanding into mixer performance. During tests of an operating pulse jet mixing system, an ultrasonic attenuation sensor was inserted into a mixing vessel to measure the slurry concentration during unsteady mixing in real time. Pulse jet mixing tests to suspend noncohesive solids in Newtonian liquid were conducted at three geometric scales. To understand the solids suspension process and resulting solids distribution, the concentration of solids in the cloud was measured at various elevations and radial positions during the pulse jet mixer cycle. This paper presents transient concentration data obtained at three scales at the tank center to provide insight into pulse jet mixer performance.

concentration profile↗

Lunar and Planetary Science XXXVI, Part 12

Topics discussed include: The Ancient Lakes in Hellas Basin Region as Seen Through the First Year of Mars Express HRSC-Camera; DISR Observations of Craters at Titan at the Huygens Landing Site: Insights Anticipated; The Sun s Dust Disk - Discovery Potential of the New Horizons Mission During Interplanetary Cruise; Evidence for Aqueously Precipitated Sulfates in Northeast Meridiani Using THEMIS and TES Data; Integrated Spectroscopic Studies of Anhydrous Sulfate Minerals; Venusian Channel Formation as a Subsurface Process; Reexamination of Quartz Grains from the Permian-Triassic Boundary Section at Graphite Peak, Antarctica; Observations of Calcium Sulfate Deposits at High Latitudes by OMEGA/Mex at Km/Pixel Resolutions; Observations of the North Permanent Cap of Mars in Mid-Summer by OMEGA/MEX at km per Pixel Resolutions; Classification and Distribution of Patterned Ground in the Southern Hemisphere of Mars Genesis: Removing Contamination from Sample Collectors; Thermal Characterization of Fe3O4 Nanoparticles Formed from Poorly Crystalline Siderite; Hydrogen Abundances in Metal Grains from the Hammadah Al Hamra (HaH) 237 Metal-rich Chondrite: A Test of the Nebular-Formation Theory; REE and Some Other Trace Elements Distributions of Mineral Separates in Atlanta (EL6); The Composition and Origin of the Dewar Geochemical Anomaly; Asteroid Modal Mineralogy Using Hapke Mixing Models: Testing the Utility of Spectral Lookup Tables; and The Huygens Mission at Titan: Results Highlights. (sup 182)Hf-(sup 182)W Chronometry and an Early Differentiation in the Parent Body of Ureilites Ground Penetrating Radar in Sedimentary Rocks Mars, Always Cold, Sometimes Wet: New Constraints on Mars Denudation Rates and Climate Evolution from Analog Studies at Haughton Crater, Devon Island, High Arctic Europa s Porous Ice Rheology and Implications for Ice-penetrating Radar Scattering Loss Surface Generated Cracks on Europa

Source record↗

Effect of swirler-mounted mixing venturi on emissions of flame-tube combustor using jet A fuel

Six headplate modules in a flame-tube combustor were evaluated. Unburned hydrocarbons, carbon monoxide, and oxides of nitrogen were measured for three types of fuel injectors both with and without a mixing venturi. Tests were conducted using jet A fuel at an inlet pressure of 0.69 megapascal, an inlet temperature of 478 K, and an isothermal static pressure drop of 3 percent. Oxides of nitrogen were reduced by over 50 percent with a mixing venturi with no performance penalties in either other gaseous emissions or pressure drop.

Ercegovic, D. B.↗

Performance of a quantitative study of instability-related delamination growth

An experimental program was conducted to quantify instability-induced imbedded delamination growth. Static tests on double cantilever beam (DCB) specimens yielded the critical mode 1 strain energy release rate (G sub 1 C) for T300/5208 graphite/epoxy. Static tests on mixed mode cracked lap shear (CLS) specimens, and a nonlinear finite element analysis (NFEA) of the CLS specimen to separate mode 1 and mode 2 effects, yielded the critical mode 2 strain energy release rate (G sub 2 C) for T300/5208. Constant amplitude fatigue tests on DCB and CLS specimens, along with the NFEA results on CLS specimens, quantified mode 1 and mode 2 contributions to delamination growth rate. Fatigue tests were conducted at a frequency (omega) of 10 Hertz, maintaining the minimum to maximum cyclic load ratio (R) at 0.05. Static compression and constant amplitude compression fatigue tests were also conducted on specimens with imbedded through the width (ITTW) delaminations. Kapton imbeddments were located below 3, 4 or 6 plies in a 64-ply laminate, during layup, to simulate ITTW delaminations.

Ramkumar, R. L.↗

Orthostatic Hypotension After Long-Duration Space Flight: NASA's Experiences from the International Space Station

Our laboratory previously reported that the incidence of orthostatic hypotension (OH) was greater after long- than short-duration spaceflight in astronauts who participated in Mir Space Station and Space Shuttle missions. To confirm and extend these findings, we retrospectively examined tilt test data from International Space Station (ISS) and Shuttle astronauts. We anticipated that the proportion of ISS astronauts experiencing OH would be high on landing day and the number of days to recover greater after long- than short-duration missions. Methods: Twenty ISS and 66 Shuttle astronauts participated in 10-min 80? head-up tilt tests 10 d before launch (L-10), on landing day (R+0) or 1 d after landing (R+1). Data from 5 ISS astronauts tested on R+0 or R+1 who used non-standard countermeasures were excluded. Many astronauts repeated the test 3 d (R+3) after landing. Fisher?s Exact Test was used to compare the ability of ISS and Shuttle astronauts to complete the tilt test on R+0. Cox regression was used to identify cardiovascular parameters that were associated with test completion across all tests, and mixed model analysis was used to compare the change and recovery rates between ISS and Shuttle astronauts. In these analyses, ISS data from R+0 and R+1 were pooled to provide sufficient statistical power. Results: The proportion of astronauts who completed the tilt test on R+0 without OH was less in ISS than in Shuttle astronauts (p=0.03). On R+0, only 2 of 6 ISS astronauts completed the test compared to 53 of 66 (80%) Shuttle astronauts. However, 8 of 9 ISS astronauts completed the test on R+1. On R+3, 13 of 15 (87%) of the ISS and 19 of 19 (100%) of the Shuttle astronauts completed the 10-min test. An index comprised of stroke volume and diastolic blood pressure provided a very good prediction of overall tilt survival. This index was altered by spaceflight similarly for both groups soon after landing (pooled R+0 and R+ 1), but ISS astronauts did not recover at the same rate as Shuttle astronauts (p=0.007). Conclusions: The proportion of ISS astronauts who could not complete the tilt test on R+0 due to OH (4 of 6) is similar to that reported in astronauts who flew on Mir (5 of 6). Further, cardiovascular parameters most closely associated with OH recover more slowly after long- compared to short-duration spaceflight.

Lee, Stuart M. C.↗

Simulant Development for Hanford Double-Shell Tank Mixing and Waste Feed Delivery Testing

The U.S. Department of Energy Office of River Projection manages the River Protection Project, which has the mission to retrieve and treat the Hanford tank waste for disposal and close the tank farms (Certa et al. 2011). Washington River Protection Solutions, LLC (WRPS) is responsible for a primary objective of this mission which is to retrieve and transfer tank waste to the Hanford Waste Treatment and Immobilization Plant (WTP). A mixing and sampling program with four separate demonstrations is currently being conducted to support this objective and also to support activities in a plan for addressing safety concerns identified by the Defense Nuclear Facilities Safety Board related to the ability of the WTP to mix, sample, and transfer fast settling particles. Previous studies have documented the objectives, criteria, and selection of non-radioactive simulants for these four demonstrations. The identified simulants include Newtonian suspending liquids with densities and viscosities that span the range expected in waste feed tanks. The identified simulants also include non-Newtonian slurries with Bingham yield stress values that span a range that is expected to bound the Bingham yield stress in the feed delivery tanks. The previous studies identified candidate materials for the Newtonian and non-Newtonian suspending fluids, but did not provide specific recipes for obtaining the target properties and information was not available to evaluate the compatibility of the fluids and particles or the potential for salt precipitation at lower temperatures. The purpose of this study is to prepare small batches of simulants in advance of the demonstrations to determine specific simulant recipes, to evaluate the compatibility of the liquids and particles, and to determine if the simulants are stable for the potential range of test temperatures. The objective of the testing, which is focused primarily on the Newtonian and non-Newtonian fluids, is to determine the composition of simulant materials that give the desired density and viscosity or rheological parameters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of ratio of wall boundary layer thickness to jet diameter on mixing of a normal hydrogen jet in a supersonic stream

A preliminary experimental program was conducted to determine the effect of the ratio of the free-stream boundary-layer thickness to jet diameter on the secondary jet penetration and mixing rate. Tests were conducted on a flat plate in a Mach number 4.05 airflow with sonic injection of hydrogen normal to the free-stream direction from circular underexpanded injectors. The ratio of boundary-layer thickness to jet diameter ranged from 1.25 to 6.5. Previous correlations of mixing performance were modified to account for the effect of the ratio of boundary-layer thickness to jet diameter.

Mcclinton, C. R.↗

Algebraic aspects of chiral symmetry

Algebraic realization of chiral symmetry and its implications are studied. Hadrons are classified by linear representations with mixing when chiral symmetry is spontaneously broken. The axial vector coupling constant is then determined by representation mixing. Phenomenological test for measuring g{sub A} of a nucleon resonance is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of FTWC Vent System

A monitored exhaust system has been designed for use in venting the Flanged Tritium Waste Containers (FTWCs) at LANL. This system will provide controlled exhaust and emissions monitoring for the FTWCs, and also provide general area exhaust around the venting operations to measure any emissions which may bypass the primary vent system. A full description of the process and need for the system is described in the Pre-Construction Application for this project. This document describes the commissioning testing performed on the FTWC vent system to prepare it for use. The system has been tested and shown to meet ANSI standard requirements and is fully suitable for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fully‐Printed Ion Sensor Arrays for Measuring Agricultural Nitrogen and Potassium Concentrations Using Nernstian and AI Models

Abstract The chemical composition of growing media is a key factor for plant growth, impacting agricultural yield and sustainability. However, there is a lack of affordable chemical sensors for ubiquitous nutrient ion monitoring in agricultural applications. This work investigates using fully printed ion‐sensor arrays to measure the concentrations of nitrate, ammonium, and potassium in mixed‐electrolyte media. Ion sensor arrays composed of nitrate, ammonium, and potassium ion‐selective electrodes and a printed silver‐silver chloride (Ag/AgCl) reference electrode are fabricated and characterized in aqueous solutions in a range of concentrations that encompass what is typical for agricultural growing media (0.01 m m –1 m ). The sensors are also tested in mixed‐electrolyte solutions of NaNO 3 , NH 4 Cl, and KCl of varying concentrations, and the recorded potentials are input into Nernstian and artificial neural network models to compare the prediction accuracy of the models against ground truth. The artificial neural network models demonstrated higher accuracy over the Nernstian model, and the model using only ion‐sensor inputs is 7.5% more accurate than the Nernstian model under the same conditions. By enabling more precise and efficient fertilizer application, these sensor arrays coupled to computational models can help increase crop yields, optimize resource use, and reduce environmental impact.

Goodrich, Payton [University of California Berkele↗

Activation behavior for ion permeation in ion-exchange membranes: Role of ion dehydration in selective transport

Here we explored the mechanisms governing the selectivity of anion- and cation-exchange membranes for the transport of four monovalent anions (i.e., fluoride, chloride, bromide, and nitrate) and four monovalent cations (i.e., sodium, potassium, cesium, and ammonium), respectively. Our ion adsorption and transport tests with mixed ion solutions reveal that an ion with larger ionic radius and lower hydration energy is more favorably adsorbed onto the ion-exchange membrane but diffuses more slowly through the polymer matrix compared to an ion with smaller ionic radius and higher hydration energy. Individual anion (as sodium salt) or cation (as chloride salt) permeation tests at different temperatures were performed to evaluate the activation behavior of ion transport through the ion-exchange membranes by calculating the energy barrier and pre-exponential factor (i.e., the ion flux when the energy barrier is negligible) for ion transport from an Arrhenius-type equation. Our results show that an ion with smaller ionic radius and higher hydration energy experiences higher energy barrier (e.g., fluoride, 10.3 kcal mol -1 ) and possesses higher pre-exponential factor compared to an ion with larger ionic radius and lower hydration energy (e.g., bromide, 4.6 kcal mol -1 ). This correlation corroborates our main hypothesis that the activation behavior observed for ion transport is a result of ion dehydration at the water-membrane interface. Our proposed ion selectivity mechanism elucidates how ion dehydration governs the extent of ion permeation into the membrane and the subsequent transport through the charged polymer matrix. Future membrane design that promotes dehydration of target ions is challenging but can result in unprecedented ion selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗