Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Dynamic Mooring Field Experiment and Design of a Wave Energy Converter Platform Test System

Abstract This study evaluated a multi-catenary spread mooring system design of a mobile ocean test berth for wave energy converters (WECs), the Ocean Sentinel (OS) instrumentation buoy, through dynamic simulation, numerical analysis, and comparison with measured field motion data of the OS off the OR coast. First, the accuracy of the numerical employed model based on a fully-coupled method of the OS and its mooring lines was validated by comparing predicted mooring tensions to the field measurements. Then, the anchor movability, fatigue damage, and extreme mooring tension of the OS mooring system were analyzed to assess survivability. Field test results show that the numerical model provided accurate predictions of mooring tensions even under environmental conditions of strong wind, current, and waves. Factors affecting the accuracy are discussed. One mooring anchor was shown to have moved significantly during the ocean field test. Mooring fatigue damage was calculated for different levels of sea states. Design strengths of the mooring lines were calculated and analyzed.

Engineering↗

Aerosol Vertical Profiling at Oliktok Point (AVPOP) Field Campaign Report

Aerosols are an important component of the atmospheric system through their various impacts on climate. Notably, the largest uncertainty of the energy budget (i.e., radiative forcing estimate) is the aerosol indirect effect. Aerosol-induced microphysical modifications influence cloud lifetime and albedo. However, constraining aerosol-cloud impacts in climate models, specifically in regions such as the Arctic, remains a significant challenge due to limited observations. The efficacy of an aerosol to impact the arctic energy budget largely depends on its concentration, composition, and source. While ground-based measurements will provide a consistent, high-resolution time series of aerosol observations, the arctic atmosphere can be stratified, and thus what is observed on the ground may not be representative of the aerosol aloft. A key gap in arctic aerosol research is routine vertical profiling of abundance and source characterization. Previous work outside of the Arctic has focused on using launched or tethered balloon systems (LBS and TBS, respectively) to measure vertical profiles of aerosol size distributions and has demonstrated the utility of such observations (e.g., Hofmann et al. 1989; Hofmann 1993; Iwasaka et al. 2003; Kim et al. 2003; Tobo et al. 2007). More specifically, particle spectrometers have also been deployed via TBS systems (de Boer et al. 2018; Greenberg et al. 2009; Maletto et al. 2003; Renard et al. 2016; Wehner et al. 2007; Siebert et al. 2004) affording information on aerosol layer locations and evolution by means of multiple profiles. Filter samples for post-processing of aerosol composition and ice nucleation properties have also been conducted in mid-latitudes (Creamean et al. 2018). However, while these studies present novel measurements of aerosol vertical profiling via balloon systems, few exist to date in the Arctic. The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility TBS is composed of a variety of winches, balloons, and instrumentation that flies within ARM’s Restricted Airspace (R-2204) at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska (Figure 1). The system payload comprises instruments that can simultaneously collect in situ data on horizontal winds, ice microphysics, turbulence, thermodynamic state, aerosols, and the cloud-top environment (https://www.arm.gov/capabilities/instruments/tbs). Recent campaigns at AMF3 have involved the use of the ARM helikite, which is a balloon-kite hybrid that uses lighter-than-air principles to obtain its initial lift and a kite to achieve stability and dynamic lift. Additional information on the specifications of the helikite TBS can be found in the ARM TBS handbook (Dexheimer 2018).

Oliktok Point, North Slope of Alaska,, tethered ba↗

AmeriFlux Measurement Component (AMC) Instrument Handbook

An AMC system was installed at the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling photosynthetically active radiation (PAR) sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape.

54 ENVIRONMENTAL SCIENCES↗

Identifiability analysis of rotational diffusion tensor and electronic transition moments measured in time-resolved fluorescence depolarization experiment

The subject of this paper is studies of the deterministic identifiability of molecular parameters, such as rotational diffusion tensor components and orientation of electronic transition moments, resulting from the time-resolved fluorescence anisotropy experiment. In the most general case considered, a pair of perpendicularly polarized emissions enables the unique determination of all the rotational diffusion tensor's principal components. The influence of the tensor's symmetry and the associated degeneration of its eigenvalues on the identifiability of the electronic transitions moments is systematically investigated. The analysis reveals that independently of the rotational diffusion tensor's symmetry, the transition moments involved in photoselection and emission processes cannot be uniquely identified without a priori information about their mutual orientation or their orientation with respect to the principal axes of the tensor. Moreover, it is shown that increasing the symmetry of the rotational diffusion tensor deteriorates the degree of the transition moments identifiability. To obtain these results analytically, a novel approach to solve bilinear system of equations for Markov parameters is applied. The effect of the additional information, obtained from fluorescence measurements for different molecular mobilities, to improve the identifiability at various levels of analysis is shown. The effectiveness and reliability of the target analysis method for experimental determination of the molecular parameters is also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the safety of mobile units for the conditioning of radioactive waste

In Germany mobile units are used to treat and condition radioactive waste. On behalf of the relevant authorities TUV SUD Industrie Service GmbH evaluates their safety. In this paper we outline the general procedure we apply and point out typical results. Generally, a generic safety case evaluates the effects of incidents and accidents and its consequences for the workers and the public. Special care is necessary to define the radioactive inventory, the nuclide composition and the mobility of the radioactive substances. A systems analysis is carried out. Typical aspects to be considered are the handling procedures, the measurement devices and automatic actions. From the various possible malfunctions the critical ones have to be identified. Generally one or only a few scenarios have to be considered in detail. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summer Aerosol and Trace Gas Observations in Houston, Texas Using an Adaptable Mobile Facility

An aerosol container featuring a shared inlet system was deployed to Houston, Texas in July 2022, enabling direct, high-time-resolution in situ measurements of aerosols and trace gases. The internal rack system and floorplan was designed for adaptable modularity to elucidate aerosol physicochemical processes at fine scales. The design allowed for the deployment of a core instrument suite and additional customized research grade instruments. A heterogeneous mixture of aerosols was observed during three regimes: (1) intermittent black carbon (BC) and diurnal variations in aerosol chemical composition, (2) observed particle growth associated with SO 2 , (3) transported supermicron dust. The high variability of observed particles and gases in high time resolution indicated a complex urban area with multiple local and regional sources and processes. Particle growth rates of 7–16 nm/hr were observed for submicron particles during periods when SO 2 was >0.5 ppbv. Two periods of multi-day long-range transport events of dust from the African Sahara were observed in the supermicron and submicron particle modes with total mass concentrations up to 30 μg m −3 . Aerosol scattering angstrom exponents and extinction coefficients (B ext ) increased with humidity as a function of particle composition. The measurements demonstrate collaborative capabilities that can be used to increase observations of aerosol processing, microphysical and optical properties, internal mixing state, and supermicron aerosol that are not parameterized or missing in global Earth energy system models.

54 ENVIRONMENTAL SCIENCES↗

Surface-based observations of cold-air outbreak clouds during the COMBLE field campaign

Abstract. Cold-air outbreaks (CAOs) are characterized by extreme air–sea energy exchanges and low-level convective clouds over large areas in the high-latitude oceans. As such, CAOs are an important component of the Earth's climate system. The CAOs in the Marine Boundary Layer Experiment (COMBLE) deployment of the US Department of Energy Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF) provided the first comprehensive view of CAOs using a suite of ground-based observations at the northern coast of Norway. Here, cloud and precipitation observations from 13 CAO cases during COMBLE are analyzed. A vertical air motion retrieval technique is applied to the Ka-band ARM Zenith-pointing Radar (KAZR) observations. The CAO cumulus clouds are characterized by strong updrafts with magnitudes between 2–8 m s−1, vertical extents of 1–3 km, and horizontal scales of 0.25–3 km. A strong relationship between our vertical air velocity retrievals and liquid water path (LWP) measurements is found. The LWP measurements exceed 1 kg m−2 in strong updraft areas, and the vertical extent of the updraft correlates well with the LWP values. The CAO cumulus clouds exhibit eddy dissipation rate values between 10−3 and 10−2 m2 s−3 in the lowest 10 km of the atmosphere, and using a radar Doppler spectra technique, evidence of secondary ice production is found during one of the cases.

54 ENVIRONMENTAL SCIENCES↗

MCNP Techniques for Modeling Sodium Iodide Spectra of Kiwi Surveys

This work demonstrates how MCNP can be used to predict the response of mobile search and survey equipment from base principles. The instrumentation evaluated comes from the U.S. Department of Energy’s Aerial Measurement Systems. Through reconstructing detector responses to various point-source measurements, detector responses to distributed sources can be estimated through superposition. Use of this methodology for currently deployed systems allows predictive determinations of activity levels and distributions for common configurations of interest. This work helps determine the quality and efficacy of certain surveys in fully characterizing an effected site following a radiological event of national interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple-Input Data Acquisition System (MIDAS) for Measuring the Carbon Content in Soil Using Inelastic Neutron Scattering

This report describes work funder under STTR grants Phase I and II and carried out jointly by XIA LLC and Brookhaven National Laboratory (BNL). The project goal was to develop a mobile nuclear activation analysis instrument that could be towed behind a tractor to document soil carbon levels in agricultural lands for carbon credit certification. XIA developed large NaI(Tl) detectors with integrated digital pulse processors controlled over USB 2.0 and delivered 16 of these units to BNL for integration into the prototype instrument, together with the necessary software to calibrate them and collect data. For reasons that are unknown to XIA, the BNL participants never completed the prototype vehicle, performed system integration, or carried out the proposed qualification and field tests, leaving the project incomplete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Application of 238 U/ 235 U Measurements To Detect Reoxidation and Mobilization of U(IV)

Biostimulation to induce reduction of soluble U(VI) to relatively immobile U(IV) is an effective strategy for decreasing aqueous U(VI) concentrations in contaminated groundwater systems. If oxidation of U(IV) occurs following the biostimulation phase, U(VI) concentrations increase, challenging the long-term effectiveness of this technique. However, detecting U(IV) oxidation through dissolved U concentrations alone can prove difficult in locations with few groundwater wells to track the addition of U to a mass of groundwater. In this paper, we propose the 238 U/ 235 U ratio of aqueous U as an independent, reliable tracer of U(IV) remobilization via oxidation or mobilization of colloids. Reduction of U(VI) produces 238 U-enriched U(IV), whereas remobilization of solid U(IV) should not induce isotopic fractionation. The incorporation of remobilized U(IV) with a high 238 U/ 235 U ratio into the aqueous U(VI) pool produces an increase in 238 U/ 235 U of aqueous U(VI). Finally, during several injections of nitrate to induce U(IV) oxidation, 238 U/ 235 U consistently increased, suggesting 238 U/ 235 U is broadly applicable for detecting mobilization of U(IV).

54 ENVIRONMENTAL SCIENCES↗

Cyclotron resonance in the high mobility GaAs/AlGaAs 2D electron system over the microwave, mm-wave, and terahertz- bands

Abstract The reflected microwave power from the photo-excited high mobility GaAs/AlGaAs 2D device has been measured over the wide frequency band spanning from 30 to 330 GHz simultaneously along with diagonal magnetoresistance as a function of the magnetic field. Easily distinguishable resonances in the reflected power signal are observed at the same magnetic fields as a reduced amplitude in the Shubnikov-de Haas (SdH) oscillations of the diagonal magnetoresistance. The reflection resonances with concurrent amplitude reduction in SdH oscillations are correlated with cyclotron resonance induced by microwave, mm-wave, and terahertz photoexcitation. The magnetoplasma effect was also investigated. The results suggest a finite frequency zero-magnetic-field intercept, providing an estimate for the plasma frequency. The experimentally measured plasma frequency appears to be somewhat lower than the estimated plasma frequency for these Hall bars. The results, in sum, are consistent with an effective mass ratio of m*/m = 0.067, the standard value, even in these high mobility GaAs/AlGaAs devices, at very large filling factors. Preliminary findings from this article have been published as conference proceedings, see Kriisa, A., et al ., J. of Phys. Conf. Ser . 864 , 012057 (2017).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of THz radiation with devices made from wafers with HgTe and InSb quantum wells

In this study we present measurements of the Terahertz (THz) photoconductivity of 2D electron system realized at HgTe/HgCdTe and AlInSb/InSb/AlInSb quantum wells (QWs) in Corbino geometry (inner and outer radius: 500 {mu}m and 1500 {mu}m) with different mobilities and electron densities. To characterize the devices, the Shubnikov-de Haas (SdH) effect up to magnetic fields B of 7T and current-voltage (I-V) characteristics at various magnetic fields were measured. The THz radiation is provided by a p-Ge laser which operates with a magnetic field and a high voltage for the electrical pumping. The stimulated emission is caused by transitions between Landau levels of light holes [1]. The laser is tunable in the range between 1.7 to 2.5 THz (corresponding to wavelengths between 120 to 180 {mu}m or energies of 7 to 12 meV). The laser is pulsed with a pulse rate of 1 Hz and pulse lengths of about 1 {mu}s with low switching times (about 20 ns). The monochromatic THz radiation is transferred to our samples via a 0.32m long brass waveguide immersed in liquid Helium. The detection of a change in the conductivity of the sample due to absorption of THz-radiation (photoresponse) requires a low-noise circuit. For the Corbino-shaped samples the photoresponse (PR) is measured via a resistor R{sub V} of 1 k{Omega}. The signal is transferred via in a high-frequency cable and detected with a digital oscilloscope.

36 MATERIALS SCIENCE↗

Explanation and Application of the Evolving Contact Traction Fields in Shallow Foundation Systems

The present paper provides a qualitative discussion of the evolution of contact traction fields beneath rigid shallow foundations resting on granular materials. A phenomenological similarity is recognized in the measured contact traction fields of rigid footings and at the bases of sandpiles. This observation leads to the hypothesis that the stress distributions are brought about by the same physical phenomena, namely the development of arching effects through force chains and mobilized intergranular friction. A set of semi-empirical equations are suggested for the normal and tangential components of this contact traction based on past experimental measurements and phenomenological assumptions of frictional behaviors at the foundation system scale. These equations are then applied to the prescribed boundary conditions for the analysis of the settlement, resistance, and stress fields in supporting granular materials beneath the footing. A parametric sensitivity study is performed on the proposed modelling method, highlighting solutions to the boundary-value problems in an isotropic, homogeneous elastic half-space.

42 ENGINEERING↗

Vertical distribution of aerosols in the vicinity of Mexico City during MILAGRO-2006 Campaign

On 7 March 2006, a mobile, ground-based, vertical pointing, elastic lidar system made a North-South transect through the Mexico City basin. Column averaged, aerosol size distribution (ASD) measurements were made on the ground concurrently with the lidar measurements. The ASD ground measurements allowed calculation of the column averaged mass extinction efficiency (MEE) for the lidar system (1064 nm). The value of column averaged MEE was combined with spatially resolved lidar extinction coefficients to produce total aerosol mass concentration estimates with the resolution of the lidar (1.5 m vertical spatial and 1 s temporal). Airborne ASD measurements from DOE G-1 aircraft made later in the day on 7 March 2006, allowed the evaluation of the assumptions of constant ASD with height and time used for estimating the column averaged MEE. The results showed that the aerosol loading within the basin is about twice what is observed outside of the basin. The total aerosol base concentrations observed in the basin are of the order of 200 {mu}g/m{sup 3} and the base levels outside are of the order of 100 {mu}g/m{sup 3}. The local heavy traffic events can introduce aerosol levels near the ground as high as 900 {mu}g/m{sup 3}. The article presents the methodology for estimating aerosol mass concentration from mobile, ground-based lidar measurements in combination with aerosol size distribution measurements. An uncertainty analysis of the methodology is also presented.

54 ENVIRONMENTAL SCIENCES↗

Enhancing the Electron Mobility via Delta-Doping in SrTiO3

We fabricated high-mobility {delta}-doped structures in SrTiO{sub 3} thin films in order to investigate the low temperature electronic transport properties of confined carriers in this system. An enhancement of the electron mobility above the bulk value was observed as the doped layer thickness decreased. High-field Hall measurements revealed that this mobility enhancement originates from higher-mobility electrons in the undoped clean regions, which have quantum-mechanically broadened from the doped layer. Because of the absence of apparent lattice misfit between the layers, this structure is highly suitable for investigating two-dimensional electron gases in SrTiO{sub 3}

36 MATERIALS SCIENCE↗

An Analysis of Field-Aged Diesel Particulate Filter Performance: Particle Emissions Before, During and After Regeneration

A field-aged, passive diesel particulate filter (DPF) employed in a school bus retrofit program was evaluated for emissions of particle mass and number concentration before, during and after regeneration. For the particle mass measurements, filter samples were collected for gravimetric analysis with a partial flow sampling system, which sampled proportionally to the exhaust flow. Total number concentration and number-size distributions were measured by a condensation particle counter and scanning mobility particle sizer, respectively. The results of the evaluation show that the number concentration emissions decreased as the DPF became loaded with soot. However after soot removal by regeneration, the number concentration emissions were approximately 20 times greater, which suggests the importance of the soot layer in helping to trap particles. Contrary to the number concentration results, particle mass emissions decreased from 6 1 mg/hp-hr before regeneration to 3 2 mg/hp-hr after regeneration. This indicates that nanoparticles with diameter less than 50 nm may have been emitted after regeneration since these particles contribute little to the total mass. Overall, average particle emission reductions of 95% by mass and 10,000-fold by number concentration after four years of use provided evidence of the durability of a field-aged DPF. In contrast to previous reports for new DPFs in which elevated number concentrations occurred during the first 200 seconds of a transient cycle, the number concentration emissions were elevated during the second half of the heavy-duty federal test procedure when high speed was sustained. This information is relevant for the analysis of mechanisms by which particles are emitted from field-aged DPFs.

33 ADVANCED PROPULSION SYSTEMS↗

SU-E-I-21: Dosimetric Characterization and Image Quality Evaluation of the AIRO Mobile CT Scanner

Purpose: The AIRO Mobile CT system was recently introduced which overcomes the limitations from existing CT, CT fluoroscopy, and intraoperative O-arm. With an integrated table and a large diameter bore, the system is suitable for cranial, spine and trauma procedures, making it a highly versatile intraoperative imaging system. This study is to investigate radiation dose and image quality of the AIRO and compared with those from a routine CT scanner. Methods: Radiation dose was measured using a conventional 100mm pencil ionization chamber and CT polymethylmetacrylate (PMMA) body and head phantoms. Image quality was evaluated with a CATPHAN 500 phantom. Spatial resolution, low contrast resolution (CNR), Modulation Transfer Function (MTF), and Normalized Noise Power Spectrum (NNPS) were analyzed. Results: Under identical technique conditions, radiation dose (mGy/mAs) from the AIRO mobile CT system (AIRO) is higher than that from a 64 slice CT scanner. MTFs show that both Soft and Standard filters of the AIRO system lost resolution quickly compared to the Sensation 64 slice CT. With the Standard kernel, the spatial resolutions of the AIRO system are 3lp/cm and 4lp/cm for the body and head FOVs, respectively. NNPSs show low frequency noise due to ring-like artifacts. Due to a higher dose in terms of mGy/mAs at both head and body FOV, CNR of the AIRO system is higher than that of the Siemens scanner. However detectability of the low contrast objects is poorer in the AIRO due to the presence of ring artifacts in the location of the targets. Conclusion: For image guided surgery applications, the AIRO has some advantages over a routine CT scanner due to its versatility, large bore size, and acceptable image quality. Our evaluation of the physical performance helps its future improvements.

60 APPLIED LIFE SCIENCES↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗