At least 163 records · Page 9

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Development of a 200-kW Turbo-Electric Distributed Propulsion Testbed

The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC) (Edwards, California) is developing a Hybrid-Electric Integrated Systems Testbed (HEIST) Testbed as part of the HEIST Project, to study power management and transition complexities, modular architectures, and flight control laws for turbo-electric distributed propulsion technologies using representative hardware and piloted simulations. Capabilities are being developed to assess the flight readiness of hybrid electric and distributed electric vehicle architectures. Additionally, NASA will leverage experience gained and assets developed from HEIST to assist in flight-test proposal development, flight-test vehicle design, and evaluation of hybrid electric and distributed electric concept vehicles for flight safety. The HEIST test equipment will include three trailers supporting a distributed electric propulsion wing, a battery system and turbogenerator, dynamometers, and supporting power and communication infrastructure, all connected to the AFRC Core simulation. Plans call for 18 high performance electric motors that will be powered by batteries and the turbogenerator, and commanded by a piloted simulation. Flight control algorithms will be developed on the turbo-electric distributed propulsion system.

distributed↗

The space station tethered elevator system

The optimized conceptual engineering design of a space station tethered elevator is presented. The elevator is an unmanned mobile structure which operates on a ten kilometer tether spanning the distance between the Space Station and a tethered platform. Elevator capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The potential uses, parameters, and evolution of the spacecraft design are discussed. Engineering development of the tethered elevator is the result of work conducted in the following areas: structural configurations; robotics, drive mechanisms; and power generation and transmission systems. The structural configuration of the elevator is presented. The structure supports, houses, and protects all systems on board the elevator. The implementation of robotics on board the elevator is discussed. Elevator robotics allow for the deployment, retrieval, and manipulation of tethered objects. Robotic manipulators also aid in hooking the elevator on a tether. Critical to the operation of the tethered elevator is the design of its drive mechanisms, which are discussed. Two drivers, located internal to the elevator, propel the vehicle along a tether. These modular components consist of endless toothed belts, shunt-wound motors, regenerative power braking, and computer controlled linear actuators. The designs of self-sufficient power generation and transmission systems are reviewed. Thorough research indicates all components of the elevator will operate under power provided by fuel cells. The fuel cell systems will power the vehicle at seven kilowatts continuously and twelve kilowatts maximally. A set of secondary fuel cells provides redundancy in the unlikely event of a primary system failure. Power storage exists in the form of Nickel-Hydrogen batteries capable of powering the elevator under maximum loads.

Anderson, Loren A.↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Synthesis, modular composition, and electrochemical properties of lamellar iron sulfides

Transition metal chalcogenides with layered structures are promising materials for energy storage, catalysis, and electronics, among other areas. We have identified a new layered phase of iron sulfide containing interlayer solvated cations. We present an optimized synthesis for the Li + -containing material from an Fe(III) xanthate complex. Structure and composition data indicate the material consists of poorly-ordered iron sulfide layers separated by solvated cations. The lamellar spacing in these materials can be tuned by changing the identity of the cation. Furthermore, the lamellar spacing can also be reversibly tuned by the degree of solvation of the material. The material is electrically conductive and can serve as a pseudocapacitor with comparable performance to commercial materials such as MnO 2 . Finally, these materials also show promise as lithium or sodium ion battery cathodes with good capacity and reversibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An integrated and modular digital modeling approach for the space station electrical power system development

An electrical power system for the Space Station was designed, developed and built. This system provides for electrical power generation, conditioning, storage, and distribution. The initial configuration uses photovoltaic power generation. The power system control is based on a hierarchical architecture to support the requirements of automation. In the preliminary design and technology development phase of the program, various modeling techniques and software tools were evaluated for the purpose of meeting the Space Station power system modeling requirements. Rocketdyne and LeRC jointly selected the EASY5 simulation software, developed by Boeing Computer Services, as a system level modeling tool. The application of the selected analytical modeling approach to represent the entire power system is described. Typical results of model predictions are also summarized. The equipment modeled includes solar arrays, dc to ac converters, resonant inverters, battery storage system, alternator, transmission line, switch gear, and system level microprocessor controls. During the advanced development phase of this program, several models were developed using this approach.

Gombos, Frank J.↗

An integrated and modular digital modeling approach for the Space Station electrical power system development

An electrical power system for the Space Station was designed, developed and built. This system provides for electrical power generation, conditioning, storage, and distribution. The initial configuration uses photovoltaic power generation. The power system control is based on a hierarchical architecture to support the requirements of automation. In the preliminary design and technology development phase of the program, various modeling techniques and software tools were evaluated for the purpose of meeting the Space Station power system modeling requirements. Rocketdyne and LeRC jointly selected the EASY5 simulation software, developed by Boeing Computer Services, as a system level modeling tool. The application of the selected analytical modeling approach to represent the entire power system is described. Typical results of model predictions are also summarized. The equipment modeled includes solar arrays, dc to ac converters, resonant inverters, battery storage system, alternator, transmission line, switch gear, and system level microprocessor controls. During the advanced development phase of this program, several models were developed using this approach.

Gombos, Frank J.↗

Performance and Total Cost of Ownership of a Fuel Cell Hybrid Mining Truck

The main objective of this work was to investigate the potential of hydrogen and fuel cells replacing diesel and internal combustion engines in the ultraclass haul trucks deployed in the mining sector. Performance, range, durability, and cost are the main criteria considered for comparing the two fuels and engine options. Fuel cell system (FCS) performance is characterized in terms of heat rejection, efficiency, and fuel consumption for a hybrid platform equivalent to a 3500 hp diesel engine operating on a representative open pit mining duty cycle. A hybrid platform was chosen because the heat rejection, with a constrained radiator frontal area, limits the maximum fuel cell-rated power by about 50% compared to that of the diesel truck. The hybrid powertrain was 81–88% more efficient than the diesel powertrain on the truck duty cycle. A liquid hydrogen storage system is required for an equal range or time between refilling, but the packaging remains a challenge. Fuel cell and battery durability were evaluated for their performance degradation and lifetime. Achieving a fuel cell lifetime comparable to the time between major overhauls for diesel trucks necessitates the oversizing of the membrane-active area, catalyst overloading, and voltage clipping. For an equal lifetime, the battery must be oversized to control its depth of discharge and charge/discharge rates. A total cost of ownership (TCO) analysis considering the initial capital expenditures, as well as the lifetime cost of fuel, operation, and maintenance, indicates that fuel cells and hydrogen can compete with diesel. A breakeven fuel cost for TCO parity is obtained if H2 is available at USD 5.79–6.85/kg vs. diesel at USD 3.25/gal and the FCS-specific cost is USD 323/kW e relative to USD 250/kW for a diesel genset. Volume manufacturing is required for FCS cost reduction. High volume is possible through the standardization, modularity, and proliferation of class 8 long-haul truck systems across different heavy-duty applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Annual Technology Baseline: The 2024 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, nuclear, coal, and natural gas. EIA data for conventional biopower are included for reference. This webinar presentation introduces the 2024 update to the ATB Electricity data and documentation.

battery storage↗

Space transportation

The physical laws governing launch vehicles are reviewed, together with the performance of launch vehicles thus far used and expected developments in space transportation systems. Launches are generally made in the direction of earth rotation to take advantage of the initial velocity in that direction, which can amount to about 0.46 km/sec at the equator. Spacecraft usually attain a parking orbit, where spacecraft conditions are assessed before moving on to final orbit or interplanetary trajectory. Rocket batteries were first used in a battle near Beijing in 1232, and manned space flight began with the Vostok flight in 1961, followed by the Apollo lunar landings in the later 1960s. Rocket thrust performance is analyzed, together with the thrust/mass ratio for ascent and descent. The Shuttle, capable of placing 29.5 t in LEO, will be or is equipped to also carry IUS and PAM engines for transferring payloads from LEO to GEO. Parallel burn boosters may be added to increase the payload capability, and Shuttle-derived launch vehicles may be developed to carry construction materials to space and return to earth for a runway landing. Alternatively, the Shuttle engines may be modularized in order to develop a heavy-lift launch vehicle for unmanned cargo ascents.

Davis, H.↗

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic stand-alone modular systems, phase 2

The final hardware and system qualification phase of a two part stand-alone photovoltaic (PV) system development is covered. The final design incorporated modular, power blocks capable of expanding incrementally from 320 watts to twenty kilowatts (PK). The basic power unit (PU) was nominally rated 1.28 kWp. The controls units, power collection buses and main lugs, electrical protection subsystems, power switching, and load management circuits are housed in a common control enclosure. Photo-voltaic modules are electrically connected in a horizontal daisy-chain method via Amp Solarlok plugs mating with compatible connectors installed on the back side of each photovoltaic module. A pair of channel rails accommodate the mounting of the modules into a frameless panel support structure. Foundations are of a unique planter (tub-like) configuration to allow for world-wide deployment without restriction as to types of soil. One battery string capable of supplying approximately 240 ampere hours nominal of carryover power is specified for each basic power unit. Load prioritization and shedding circuits are included to protect critical loads and selectively shed and defer lower priority or noncritical power demands. The baseline system, operating at approximately 2 1/2 PUs (3.2 kW pk.) was installed and deployed. Qualification was successfully complete in March 1983; since that time, the demonstration system has logged approximately 3000 hours of continuous operation under load without major incident.

Naff, G. J.↗

An Adaptable Power System with Software Control Algorithm

A low cost, flexible and modular spacecraft power system design was developed in response to a call for an architecture that could accommodate multiple missions in the small to medium load range. Three upcoming satellites will use this design, with one launch date in 1999 and two in the year 2000. The design consists of modular hardware that can be scaled up or down, without additional cost, to suit missions in the 200 to 600 Watt orbital average load range. The design will be applied to satellite orbits that are circular, polar elliptical and a libration point orbit. Mission unique adaptations are accomplished in software and firmware. In designing this advanced, adaptable power system, the major goals were reduction in weight volume and cost. This power system design represents reductions in weight of 78 percent, volume of 86 percent and cost of 65 percent from previous comparable systems. The efforts to miniaturize the electronics without sacrificing performance has created streamlined power electronics with control functions residing in the system microprocessor. The power system design can handle any battery size up to 50 Amp-hour and any battery technology. The three current implementations will use both nickel cadmium and nickel hydrogen batteries ranging in size from 21 to 50 Amp-hours. Multiple batteries can be used by adding another battery module. Any solar cell technology can be used and various array layouts can be incorporated with no change in Power System Electronics (PSE) hardware. Other features of the design are the standardized interfaces between cards and subsystems and immunity to radiation effects up to 30 krad Total Ionizing Dose (TID) and 35 Mev/cm(exp 2)-kg for Single Event Effects (SEE). The control algorithm for the power system resides in a radiation-hardened microprocessor. A table driven software design allows for flexibility in mission specific requirements. By storing critical power system constants in memory, modifying the system code for other programs is simple. These constants can be altered also by ground command, or in response to an anomolous event. All critical power system functions have backup hardware functions to prevent a software or computer glitch from propagating. A number of battery charge control schemes can be implemented by selecting the proper control terms in the code. The architecture allows the design engineer to tune the system response to various system components and anticipated load profiles without costly alterations. A design trade was made with the size, weight and power dissipation of the electronics versus the performance of the power bus to load variations. Linear, fine control is maintained with a streamlined electronics design. This paper describes the hardware design as well as the software control algorithm. The challenges of closing the system control loop digitally is discussed. Control loop margin and power system performance is presented. Lab measurements are shown and compared to the system response of a hardware model running actual flight software.

Castell, Karen↗

Milli-Watt Radioisotope Power to Enable Small, Long-Term Robotic “Probe” Space Exploration

Milli-watt Radioisotope Power Systems (RPS) based on Radioisotope Heater Units (RHUs) could be an ideal power source for certain spacecraft that cannot use solar power due to large distances from the sun, or other environmental constraints, and where they enable or significantly enhance the ability of a mission to meet its scientific or operational goals. Various modular, compact RHU-based thermoelectric (TE) generator concepts developed or derived from current NASA Small Business Innovation Research (SBIR) projects satisfying this need have been investigated. These modular, compact and low mass power systems could support small, highly-mobile robotic exploration packages, and could be incorporated into different robotic package concepts, spacecraft or satellites. Current modular RPS design concepts with 40mW, 80mW and 120mW power levels use RHUs and Bi2Te3 TE converters. Skutterudites materials could be used in the future if new higher thermal energy output and higher temperature miniature heat sources were developed, for example, using technologies currently in the General Purpose Heat Source (GPHS) used in higher electric power output RTGs. Small (a.k.a., “mice-like”) robotic packages could effectively utilize these RHU-driven power levels to accommodate crawling, climbing, monitoring, taking measurements, and communicating during long-term planetary missions aimed at gathering environmental and geologic data (i.e., over multiple decades). Waste heat from the cold side of the TE converter could also be directed toward the electronics and / or energy storage (e.g. batteries) to keep them within design temperature ranges. In addition to power generation and electronics / battery heating, the RHU / TE configuration could be designed to survive an external 500°C bake out procedure for critical spacecraft sterilization, environmental certification and planetary protection. Analytical studies have been performed to optimize various design configurations for power, mass, volume and robotic mobility. Specific power (mW/kg) and volumetric specific power (mW/cm3) characteristics of various design configurations will be presented and key conceptual design tradeoffs will be discussed. Hot- and cold-side thermal interfaces required to meet power and mass goals and associated design sensitivities will also be discussed. RHU / TE systems must overcome critical design challenges to survive high-g loadings in some robotic applications and we will examine the mass impacts required to satisfy various dynamic loading environments up to 10,000 g’s. Power can be generated for a minimum of 30 years or more using plutonium-238 dioxide heat sources (given that Pu-238 has an 87.7 year half-life) with some reduction in power as the heat source naturally degrades.

Bahrami, Poyan↗

Solid-state rigid-rod polymer composite electrolytes with nanocrystalline lithium ion pathways

A critical challenge for next-generation lithium-based batteries lies in development of electrolytes that enable thermal safety along with use of high-energy-density electrodes. We describe molecular ionic composite (MIC) electrolytes based on an aligned liquid crystalline polymer combined with ionic liquids and concentrated Li salt. This high strength (200 MPa) and non-flammable solid electrolyte possesses outstanding Li + conductivity (1 mS cm -1 at 25 °C) and electrochemical stability (5.6 V vs Li|Li + ) while suppressing dendrite growth and exhibiting low interfacial resistance (32 Ω cm 2 ) and overpotentials (≤ 120 mV @ 1 mA cm -2 ) during Li symmetric cell cycling. A heterogeneous salt doping process modifies a locally ordered polymer-ion assembly to incorporate an inter-grain network filled with defective LiFSI & LiBF 4 nanocrystals, strongly enhancing Li + conduction. Furthermore, this modular material fabrication platform shows promise for safe and high-energy-density energy storage and conversion applications, incorporating the fast transport of ceramic-like conductors with the superior flexibility of polymer electrolytes.

25 ENERGY STORAGE↗

Advanced Sensor Systems for Biotelemetry

The present invention relates to telemetry-based sensing systems that continuously measures physical, chemical and biological parameters. More specifically, these sensing systems comprise a small, modular, low-power implantable biotelemetry system capable of continuously sensing physiological characteristics using implantable transmitters, a receiver, and a data acquisition system to analyze and record the transmitted signal over several months. The preferred embodiment is a preterm labor and fetal monitoring system. Key features of the invention include Pulse Interval Modulation (PIM) that is used to send temperature and pressure information out of the biological environment. The RF carrier frequency is 174-216 MHz and a pair of RF bursts (pulses) is transmitted at a frequency of about 1-2 Hz. The transmission range is 3 to 10 feet, depending on the position of the transmitter in the body and its biological environment. The entire transmitter is encapsulated in biocompatible silicone rubber. Power is supplied by on-board silver-oxide batteries. The average power consumption of the current design is less than 30 microW, which yields a lifetime of approximately 6 - 9 months. Chip-on-Board technology (COB) drastically reduces the size of the printed circuit board from 38 x 28 mm to 22 x 8 mm. Unpackaged dies are flip-chip bonded directly onto the printed circuit board, along with surface mount resistors and capacitors. The invention can monitor additional physiological parameters including, but not limited to, ECG, blood gases, glucose, and ions such as calcium, potassium, and sodium.

Hines, John W.↗