Search NASA⌕ Search

SEARCH · Search NASA

Results for “Molten Salt Technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Temperature and anion ligand field dependence of LnCl 3 (Ln = Nd, Dy, Sm) electronic absorption spectra in LiCl–KCl eutectic molten salt

A comprehensive knowledge of the coordination, bonding, and speciation of elements in molten salt mixtures is necessary to understand and predict the chemical and physical properties of the salt. Absorption spectroscopy can yield information about the chemistry of species of interest in alkali halide molten salt mixtures by revealing information about the electronic structure and transitions of those species. In this study, ultraviolet (UV), visible (vis), and near-infrared (NIR) absorption spectroscopy was used to examine changes to the electronic structure of trivalent Nd, Sm, and Dy in LiCl–KCl eutectic molten salt with changes in temperature and the anion composition of the melt. With increasing temperature, changes to spectral features suggest a distortion of the coordination complexes. Changes to lineshape with the substitution of alternative halide anions were examined and analyzed, revealing differences in the coordination for I – versus F – with the lanthanides. Gaussian peak fitting was used to show that the changes in lineshape with the progressive addition of F – anions can be explained by the superposition of a set of absorption bands from complexes with all Cl – anion ligands and a set of blueshifted absorption bands from complexes containing both F – and Cl – anion ligands. Finally, this work yields a new method to analyze and interpret change to electronic absorption spectra for f-block elements dissolved in alkali halide molten salts as well as new observations of the interactions of larger and smaller halide anions with lanthanides in Cl – -based molten salts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Molten Salt Thermal Property Uncertainty Workshop Report

Operation of a molten salt fueled reactor is governed, more so than any other type of reactor, by the thermal properties of the molten salt fuel because it is in a liquid form. The composition of the fuel salt will evolve during use in a reactor, as fission products are generated and corrosion of structural materials release corrosion products into the salt. The recently released NUREG/CR7299 states that fuel qualification for molten salt fuels will be based upon maintaining fuel salt properties within an acceptable range that results in achievement of fundamental safety functions (NUREG/CR-7299). Understanding the dependence of fuel properties on temperature and composition across the anticipated range of operating temperatures, burn-up and anticipated levels of contamination is required to qualify molten salt fuels. Measuring aspects of salt chemistry is appropriately a major thrust of the Molten Salt Reactor (MSR) campaign under the Advanced Reactor Technology program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of Electrochemical Methods to Molten Salt Reactors: Draft TLR Documenting Assessment of Electrochemical Monitoring

Nuclear Regulatory Commission (NRC) is developing the regulatory framework and technical expertise to support regulatory review of advanced non-water reactors, including molten salt reactors (MSRs). In an MSR, it is essential that the salt chemistry be maintained in a desired range in terms of redox potential for reliable operation and mitigation of corrosion to structural materials in the reactor, particularly the reactor vessel and heater exchanger. Measuring the redox potential of the salt in the reactor would also allow for the material lifetimes to be predicted more accurately, and chemical issues to be diagnosed more quickly. In addition to the chemical composition analysis by ICP-MS, electrochemical methods including potentiometry and linear wave scanning (LSC) were also used in molten salt reactor experiment (MSRE) for redox potential monitoring purposes. Electrochemcial methods offers unique advantages such as quick turnaround in results and unique capability of in-line monitoring of redox potential, and are considered popular electroanalytical techniques that can be used to monitor redox potentials and salt chemistry including impurities. The last two decades have seen significant advances in science and engineering of electrochemical methods for potential application to molten salts. The primary goal of this report is to assist NRC in understanding the monitoring of the salt chemistry by electrochemical methods and provide NRC reviewers with necessary information and tools to support regulatory review of MSR designs. This reports consists of two majors parts—Part 1, chemical potential of molten salts and effects by fission process in MSR; Part 2, assessment of electrochemical methods for application to MSRs. The TRLs of the typical relevant electrochemical methods for molten salts were evaluated based on the DOE TRL guidelines and upon a review of the current status of the electrochemical methods for two typical salt systems, fluoride and chloride, for MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Temperature-Dependent Morphological Evolution during Corrosion of the Ni-20Cr Alloy in Molten Salt Revealed by Multiscale Imaging

Understanding the mechanisms leading to the degradation of alloys in molten salts at elevated temperatures is significant for developing several key energy generation and storage technologies, including concentrated solar and next-generation nuclear power plants. Specifically, the fundamental mechanisms of different types of corrosion leading to various morphological evolution characteristics for changing reaction conditions between the molten salt and alloy remain unclear. Here, in this work, the three-dimensional (3D) morphological evolution of Ni–20Cr in KCl–MgCl 2 is studied at 600 °C by combining in situ synchrotron X-ray and electron microscopy techniques. By further comparing different morphology evolution characteristics in the temperature range of 500–800 °C, the relative rates between diffusion and reaction at the salt–metal interface lead to different morphological evolution pathways, including intergranular corrosion and percolation dealloying. In this work, the temperature-dependent mechanisms of the interactions between metals and molten salts are discussed, providing insights for predicting molten salt corrosion in real-world applications.

36 MATERIALS SCIENCE↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Surrogate Fission Products on Thermal Conductivity and Viscosity of NaCl-UCl 3

Thermophysical properties of salt systems relevant to molten salt reactors (MSRs) are experimentally measured in support of the US Department of Energy Office of Nuclear Energy (DOE-NE) MSR campaign within the Advanced Reactor Technology (ART) Program. These property measurements also support the development of the thermophysical arm of the Molten Salt Database (MSD) within DOE-NE’s Nu clear Energy Advanced Modeling and Simulation (NEAMS) Program. Several US Department of Energy (DOE) laboratories, including Oak Ridge National Laboratory (ORNL), have been capitalizing on modern methodologies and sample characterization techniques to conduct thermophysical property measurements to support these programs and to provide MSR developers and modelers with more recent and higher-quality data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Cesium Removal from Surrogate Pyroprocessing Salt by Electrodeposition

Active metals in used nuclear fuel dissolve into the salt during pyroprocessing and are not removed by electrorefining or drawdown operations. The buildup of 137 Cs over time increases the heat load and ionizing radiation level of the salt such that it must be replaced frequently, resulting in a significant amount of salt waste. An effective means of managing cesium in the molten salt electrolyte would increase the efficiency of pyroprocessing and decrease the volume of salt waste requiring disposal. A previous report summarized issues that must be addressed when developing a removal strategy and assessed the suitability of existing methods and remaining technological gaps to their application (Rose and Thomas 2023). Cesium is extremely stable in molten salt as a chloride—even more stable than the LiCl-KCl eutectic base salt used for pyroprocessing fuel—which makes removing cesium a challenge. However, sufficiently strong atomic interactions occur between active metal species and liquid metals that make the electrodeposition of active metal fission products into liquid metal electrodes energetically favorable. The feasibility of recovering cesium from LiCl-KCl pyroprocessing salt through electrodeposition into liquid metals is eing assessed by identifying potentially effective liquid metals and performing tests to determine the effectiveness of electrodepositing cesium from a LiCl/KCl salt into these liquid metals. Previous studies investigating the electrodeposition of Sr 2+ , and Ba 2+ into zinc, cadmium, bismuth, lead, tin and antimony have shown that alkali and alkaline earth metals can be electrodeposited at liquid metal cathodes (Kim et al., 2018). The removal of Ba 2+ and Sr 2+ was measured to be more efficient than the removal of monovalent cations due to the greater thermochemical driving force for alloying those elements with the liquid metal (Jang et al. 2022). Because the equilibrium potentials are dependent on the interactions of the active metal in the liquid metal, it is likely that the other alkali metals Li + , and K + , will deposit from LiCl/KCl salt with the Cs + . Therefore, application of this method to recover active metals from pyroprocessing salt will benefit from the use of a liquid metal and set of operating conditions that sufficiently increase the reduction potential of cesium to remove cesium from the waste salt with an acceptable amount of co-deposited lithium and potassium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Safety Analysis for a 400-kW Molten Salt Nuclear Battery

The Molten Salt Nuclear battery (MsNB) is a microreactor based on technology developed and operated at Oak Ridge National Laboratory in the 1960s [1]. But the MsNB has been simplified by removing pumps and valves for improved reliability and safety. The MsNB can safely provide up to 10 MWe of power for up to 10 years and potentially it can be transported by air, truck, and rail thanks due to to its small footprint. A computer model has been developed to represent a prototypical 400-kW MsNB using the ANL system code SAM [2]. The model has been used to produce a reactor thermal-hydraulic performance map and perform analysis of unprotected loss of heat sink accident scenario.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radionuclide tracing based in situ corrosion and mass transport monitoring of 316L stainless steel in a molten salt closed loop

In the study, we report an in situ corrosion and mass transport monitoring method developed using a radionuclide tracing technique for the corrosion study of 316L stainless steel (316L SS) in a NaCl–MgCl 2 eutectic molten salt natural circulation loop. This method involves cyclotron irradiation of a small tube section with 16 MeV protons, later welds at the hot leg of the molten salt flow loop, generating radionuclides 51 Cr, 52 Mn, and 56 Co at the salt–alloy interface. By measuring the activity variations of these radionuclides at different sections along the loop, both the in situ monitoring of the corrosion attack depth of 316L SS and corrosion product transport and its precipitation in flowing NaCl–MgCl 2 molten salt are achieved. While 316L SS is the focus of this study, the technique reported herein can be extended to other structural materials being used in a wide range of industrial applications.

36 MATERIALS SCIENCE↗

The Radiation-Induced Fate of Fission Product Iodine in Molten Salts

Understand and Predict Radiation-Induced Iodine Speciation, Chemistry, and Transport in High-Temperature Molten Salts Award Number: DE-AC07-05ID1451 Gregory P. Holmbeck (Gregory.Holmbeck@inl.gov), Center for Radiation Chemistry Research, Idaho National Laboratory, 1955 N. Fremont Avenue Idaho Falls, ID, 83415, USA. Project Scope The goal of this Chemical and Materials Sciences to Advance Clean Energy Technologies and Low-Carbon Manufacturing project is to understand and predict the radiation-induced speciation, chemistry, and transport of fission product iodine in the triumvirate extremes of high-temperature, ionizing radiation, and corrosive molten salts. This missing fundamental information is critical for the accelerated development and deployment of safe, clean nuclear energy based on molten salt reactor (MSR) and pyrochemical reprocessing technologies. The central hypothesis driving this research is, the radiation-induced conversion of iodide will yield an extensive suite of transient and steady-state iodine radiolysis products that will alter the bulk chemical and physical properties of the irradiated molten salt system—the speciation, distribution, and chemical transport of which will be dictated by the composition and the availability of multivalent metal cations and metal alloy interfaces. To test this hypothesis, this project initiated three synergistic Research Objectives: (1) determine how the inclusion of iodine/iodide influences the chemical and physical properties of complex molten salt mixtures; (2) elucidate the speciation and fundamental chemical behavior of transient and steady-state iodine/iodide species formed by the irradiation of molten and solid salt mixtures; and (3) understand the influence of interfacial processes on determining the final disposition of iodine in high temperature molten salts, notably the structure and chemical speciation of iodine at metal-salt interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Heaters on Molten Salt Reactors Dynamics

Recently, there has been renewed interest in the Molten Salt Reactor (MSR) concept. This interest is mainly due to its advantages over Light Water Reactors (LWRs). Among these advantages are the flexibility in the fuel choice and the possibility to burn actinides [1]. Currently, two molten research reactors are under development. A 2 MW molten salt experimental reactor has been constructed and is planned for operation in China. A 1 MW Molten Salt Research Reactor is under construction in the United States [2]. Thus, Research and Development (R&D) programs are needed for the MSR technology. Reactor dynamics studies are crucial safety evaluation studies. The development of reactor dynamics tools for MSRs started during the Molten Salt Reactor Program (MSRP) at ORNL, focusing on the Molten Salt Reactor Experiment (MSRE) [3]. Although various dynamic simulation tools are available, R&D efforts to develop specialized tools for MSRs are still ongoing [4]. The primary motivation for this interest is the goal of commercializing MSRs. Developing a dynamics tool for MSRs is crucial for analyzing their safety and supporting their demonstration efforts. A crucial safety issue in MSRs is ensuring that the fuel salt in the primary loop remains molten. This concern becomes particularly important when the reactor operates at lower power levels. Most chloride and fluoride salts used as fuel have a melting point of approximately 450 °C [5]. Therefore, maintaining fuel salt temperatures above this melting point is essential to prevent it from freezing. Freezing of the fuel salt can lead to volume expansion, potentially causing damage to reactor components [6]. Moreover, it can create local blockages within fuel salt channels, reducing cooling efficiency and resulting in hot spots [7]. Various methods can prevent fuel salt from freezing at low power levels. These include reducing the fuel mass flow rate in the primary loop, decreasing heat exchange between the primary and secondary loops in the reactor, and using electric fuel salt heaters. Reducing the mass flow rate of fuel salt in the primary loop can increase the fuel salt transit time in the core, enhancing heat production and increasing temperature. However, it can potentially lead to challenges. These include increasing the potential for fuel salt deposition on the reactor channel walls [8], affecting the overall heat transfer processes. Thus, alternative methods should be used [9]. This research investigates the effects of fuel salt heaters on the dynamics and stability during MSR operation. The investigation includes studying the reactor stability with the fuel salt heaters on and off. In addition, the reactor response to transients is compared with and without the operation of fuel salt heaters. These transients include reactivity insertion, primary and secondary pump failure, and heat sink temperature increase. The results of the reactivity insertion transient are presented in the summary.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Continuous removal of fission products from molten-salt-fueled reactors

A method based on separation of volatilized molten salt (MS) components, including by mass, is being developed to extract fission products (FPs) from operating molten-salt reactors. The initial application of this method is for accelerator-driven subcritical reactors fueled by (fluorinated molten salt) spent nuclear fuel (UNF) from any past, present, or future reactor. The actinides remain in the subcritical reactor to produce profitable energy and be transmuted while the extracted FPs can be buried without long-lived actinides such that a geologic repository is not necessarily needed to close the nuclear fuel cycle. By removing neutron-absorbing FPs and operating sub-critically, where the restrictive link between operation and criticality is broken, it is possible to envision complete burnup of the UNF fuel. The game-changing feature of continuously processing the molten salt inside the reactor while the reactor operates eliminates the need for a separate reprocessing plant. This feature also simultaneously improves the neutronics of the reactor, increasing the burnup of the fuel and extending its useful life for generating energy. Nuclear nonproliferation and need for geologic repositories are addressed by keeping actinides inside the reactor containment until they are consumed. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Waste Attributes of SMRs Scheduled for Near-Term Deployment

The purpose of this study is to evaluate the nuclear waste attributes of Small Modular Reactors (SMRs) scheduled for deployment within this decade using available data and established nuclear waste metrics, with the results compared to a reference large Pressurized Water Reactor (PWR). The current fleet of commercial nuclear reactors in the U.S. is composed of 92 large Light Water Reactors (LWR) with an average electricity generating capacity of over 1,000 MWe each. These large LWRs built on-site in massive construction projects have been the mainstay of the industry for the last 50 years. However, new construction soon is expected to include several designs of smaller reactors primarily fabricated in factories and installed in the field in modules. Some of these SMRs will also be LWRs, while some will use other coolants such as liquid metals, molten salts or gases, and different types of fuels. The technologies and economics of SMRs have been the focus of many studies, but there has been only minimal information published on the amount of nuclear waste different types of SMRs are expected to generate and no reports focused on near-term-deployable designs. In this study, the nuclear waste attributes of three small reactors scheduled for near-term-deployment, VOYGR TM (from NuScale Power), Natrium TM ab (from TerraPower), and Xe-100 (from X-energy), were assessed by comparing nuclear waste metrics with those of a reference large Pressurized Water Reactor (PWR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling support for the development of material surveillance specimens and procedures

This report describes modeling and simulation activities performed at Argonne National Laboratory supporting the development of passively actuated mechanical test articles for material surveillance in Molten Salt Reactors (MSRs). These test articles are a critical technology in formulating material surveillance programs for future MSRs to monitor the degradation in the structural properties of the materials in critical plant components. The main activity described in this report is the development of a method for inferring the amount of mechanical damage a test article has experienced during some duration of exposure to plant thermal and environmental conditions, using only mechanical test data collected from the test articles before and after exposure. The basic approach is to develop a model of the test article, including a description of mechanical degradation through continuum damage mechanics, and then use this model to cast the problem of inferring mechanical degradation in the test article materials into a shooting problem for a set of ordinary differential equations. We can then solve the shooting problem to determine the amount of damage accumulated in the sample. The report also details a few miscellaneous simulation studies completed at Argonne to support the development of the test articles themselves at Idaho National Laboratory.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗