Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multilevel methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multilevel Morphology of Complex Nanoporous Materials

This work exploits gas adsorption and small-angle X-ray scattering (SAXS) to determine the morphology of complex nanoporous materials. We resolve multiple classes of porosity including previously undetected large-scale texture that significantly compromises the canonical interpretation of gas adsorption. Specifically, a UVM-7 class mesoporous silica was synthesized that has morphological features on three length scales: macropores due to packing of 150 nm globules, 1.9 nm radius spherical mesopores inside the globules, and >7 nm pockets on and between the globules. The total and external surface areas, as well as the mesopore volume, were determined using gas adsorption (α s -plot) and SAXS. A new approach was applied to the SAXS data using multilevel fitting to determine the surface areas on multiple length scales. The SAXS analysis code is applicable to any two-phase system and is freely available to the public. The total surface area determined by SAXS was 12% greater than that obtained by gas adsorption. The macropore interfacial area, however, is only 30% of the external surface area determined by the α s -plot. The overestimation of the external surface area by the αs-plot method is attributed to capillary condensation in nanoscale surface irregularities. Here, the discrepancy is resolved assuming that the macropore–globule interfaces harbor fractally distributed nooks and crannies, which lead to gas adsorption at pressures above the mesopore filling pressure.

36 MATERIALS SCIENCE↗

Fundamental-Frequency Reactive Circulating Current Injection for Capacitor Voltage Balancing in Hybrid-MMC HVDC Systems During Riding Through PTG Faults

Here, this article presents a comprehensive analysis and a novel solution for the discharge problem on the half-bridge submodules' (HBSMs') capacitors in the hybrid modular multilevel converter (MMC)-based high-voltage direct current transmission systems under a long-term (e.g., several minutes or longer) pole-to-ground fault condition. The mechanism of this issue is analyzed, and then a solution based on fundamental-frequency reactive circulating current (FFRCC) injection is proposed. The influence of FFRCC injection is analyzed in terms of the fluctuated arm capacitor energy and the current stress of semiconductors. Moreover, an enhanced arm voltage modulation method based on HBSMs and full-bridge submodules coordinate control is proposed to accelerate the capacitor voltage balance of HBSMs. Finally, the performance of the proposed control strategy is verified by the simulation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parallel Element Agglomeration Multilevel Monte Carlo Library (ParELAGMC)

ParELAGMC is a parallel distributed memory C++ library for multilevel Monte Carlo (MLMC) simulations with algebraically constructed coarse spaces for estimating statistical moments of a quantity of interest involving solutions of partial differential equations with uncertain coefficients. A primary focus of the library is the scalable generation of Gaussian random fields using a novel stochastic PDE (SPDE) sampling technique for large-scale simulations. A key feature in the SPDE sampling technique is a novel non-matching mesh embedding technique to mitigate artificial boundary artifacts that are inherent in the method. Example applications to uncertainty quantification of subsurface flow simulations in the mixed finite element setting are provided as well.

Osborn, SarahV.↗

Scalable Multiphysics Block Preconditioning for Low Mach Number Compressible Resistive MHD with Application to Magnetic Confinement Fusion

This study investigates multiphysics block preconditioners that are critical in devising scalable Newton–Krylov iterative solvers for longer time-scale fully implicit fluid plasma models. The specific model of interest is the visco-resistive, low Mach number, compressible magnetohydrodynamics (MHD) model. This model describes the dynamics of conducting fluids in the presence of electromagnetic fields and can be used to study aspects of astrophysical phenomena, important science and technology applications, and basic plasma physics. The specific application of interest that motivates this study is the macroscopic simulation of longer time-scale stability and disruptions of magnetic confinement fusion devices, specifically the ITER Tokamak. The computational solution of the governing balance equations for mass, momentum, heat transfer, and magnetic induction for resistive MHD systems can be extremely challenging. These difficulties arise from both the strong nonlinear, nonsymmetric coupling of fluid and electromagnetic phenomena as well as the significant range of time and length scales that the interactions of these physical mechanisms produce. To handle the range of time and spatial scales of interest, a fully implicit unstructured variational multiscale finite element formulation is employed. For the scalable solution of the Newton linearized systems, fully coupled block preconditioners are designed to leverage algebraic multigrid subsolves. In conclusion, results are presented for the strong and weak scaling of the method as well as the robustness of these techniques for a large range of Lundquist numbers.

97 MATHEMATICS AND COMPUTING↗

Downscaling-Based Segmentation for Unresolved Images of Highly Heterogeneous Granular Porous Samples

Numerical simulations of pore-scale flow and transport in natural sediments require the knowledge of pore-space topology. Limited resolution of X-ray tomography is often insufficient to fully characterize pore-space structure within fine-grained regions. Single and multilevel threshold-based segmentation approaches are customarily employed to identify solid, pore and porous-solid regions by means of grey intensity thresholds. While the choice of cutoff thresholds is often arbitrary, it dramatically affects the effective properties and the dynamical response of the reconstructed porous structure. As such, we propose an algorithm of downscaling, i.e., the process of increasing image resolution, followed by segmentation, i.e., the identification of different phases, to reconstruct the unresolved pore-space from XCT images of natural geological porous media. The method, applicable to moderately unresolved, chemically homogeneous granular media, is based on a map between local pixel porosity and pore size that does not rely on the definition of arbitrary thresholds and it allows to generate a high-resolution binary image of the porous medium from poorly resolved grey-scale images. First, we validate the method on synthetic unresolved images and compare their known pore-space distribution with the extracted one. Then, we consider a synthetic porous medium and compare the pore size distribution, conductivity, and tortuosity between the original and the reconstructed structures. Finally, we apply the method to extract the pore-space distribution from unresolved XCT images of two natural sediment columns and use it (i) to parametrize a capillary-bundle model and (ii) to estimate the hydraulic conductivity by matching breakthrough behavior of passive solute transport.

58 GEOSCIENCES↗

Wireless Pulse-Width Modulation Control of Power Converters Using Ultra-Wideband Technology for Distributed High-Voltage Systems: Preprint

In this study, we present a new approach for wireless pulse-width modulation (PWM) control of a power converter, applicable to numerous power converters within a complex electrical distribution system. This method eliminates the need for multiple physical connections of gating/PWM signals among distributed converter modules. By using ultra-wideband-based communication, the PWM control signals can be wirelessly transmitted from a central controller to multiple converters simultaneously and seamlessly. System stability is thoroughly analyzed, and experimental results validate the efficacy of the wireless control scheme for a buck converter operating at a 50-kHz switching frequency. The minimum latency obtained from this setup is 5.38 mus. This control concept offers easier implementation of distributed control in high-voltage power systems, especially in multilevel architectures, even under harsh conditions with ambient noise.

ADVANCED PROPULSION SYSTEMS↗

Probing Excited-State Dynamics of Transmon Ionization

The fidelity and quantum nondemolition character of the dispersive readout in circuit QED are limited by unwanted transitions to highly excited states at specific photon numbers in the readout resonator. This observation can be explained by multiphoton resonances between computational states and highly excited states in strongly driven nonlinear systems, analogous to multiphoton ionization in atoms and molecules. In this work, we utilize the multilevel nature of high-𝐸 𝐽 /𝐸 𝐶 transmons to probe the excited-state dynamics induced by strong drives during readout. With up to ten resolvable states, we quantify the critical photon number of ionization, the resulting state after ionization, and the fraction of the population transferred to highly excited states. Moreover, using pulse shaping to control the photon number in the readout resonator in the high-power regime, we tune the adiabaticity of the transition and verify that transmon ionization is a Landau-Zener-type transition. We further extend these methods to a typical transmon with 𝐸 𝐽 /𝐸 𝐶 ≈ 55 and probe the offset-charge dependence of ionization dynamics in a timed-resolved manner. Our experimental results agree well with the theoretical prediction from a semiclassical driven transmon model and may guide future exploration of strongly driven nonlinear oscillators.

cavity quantum electrodynamics↗

Wireless Pulse-Width Modulation Control of Power Converters Using Ultra-Wideband Technology for Distributed High-Voltage Systems

In this study, we present a new approach for wireless pulse-width modulation (PWM) control of a power converter, applicable to numerous power converters within a complex electrical distribution system. This method eliminates the need for multiple physical connections of gating/PWM signals among distributed converter modules. By using ultra-wideband-based communication, the PWM control signals can be wirelessly transmitted from a central controller to multiple converters simultaneously and seamlessly. System stability is thoroughly analyzed, and experimental results validate the efficacy of the wireless control scheme for a buck converter operating at a 50-kHz switching frequency. The minimum latency obtained from this setup is 5.38 ..mu..s. This control concept offers easier implementation of distributed control in high-voltage power systems, especially in multilevel architectures, even under harsh conditions with ambient noise.

ADVANCED PROPULSION SYSTEMS↗

Submodule Capacitor Reduction for a 1 MVA SiC-Based Modular Multilevel Converter Motor Drive using High Frequency Common-Mode Voltage Injection

This paper describes a strategy to reduce the size of submodule capacitors of a 1 MVA, 0-1 kHz, 7-level modular multilevel converter (MMC) based medium voltage variable speed drive (MVVSD) using 1.7 kV SiC MOSFETs. Hardware designs of submodules to withstand high dv/dt and capacitor selection based on common mode voltage injection have been presented in literature. The issue with injection is the error in tracking of injected circulation current which results in fundamental frequency fluctuations in the submodule capacitor voltage. This paper presents a strategy for higher frequency sinusoidal common mode voltage based on more accurate tracking of the circulating current; realized through an improved control strategy combined with a higher switching frequency. Using the methods presented in this paper, a smaller submodule capacitance and reduced output current THD of the motor drive is achieved. A loss analysis model is proposed to evaluate the effect of the proposed strategy on the MMC efficiency. This helps balance the reduction in the capacitor against the increase in the losses as a result of increased switching frequency. Simulations and a down-scaled experimental setup are used to demonstrate this concept.

Potty, Karun↗

Multilevel well modeling in aggregation-based nonlinear multigrid for multiphase flow in porous media

A full approximation scheme (FAS) nonlinear multigrid solver for two-phase flow and transport problems driven by wells with multiple perforations is developed here. It is an extension to our previous work on FAS solvers for diffusion and transport problems. The solver is applicable to discrete problems defined on unstructured grids as the coarsening algorithm is aggregation-based and algebraic. To construct coarse basis that can better capture the radial flow near wells, coarse grids in which perforated well cells are not near the coarse-element interface are desired. This is achieved by an aggregation algorithm proposed in this paper that makes use of the location of well cells in the cell-connectivity graph. Numerical examples in which the FAS solver is compared against Newton's method on benchmark problems are given. In particular, for a refined version of the SAIGUP model, the FAS solver is at least 35% faster than Newton's method for time steps with a CFL number greater than 10.

58 GEOSCIENCES↗

Machine Learning Applied to a Variable Charge Atomistic Model for Cu/Hf Binary Alloy Oxide Heterostructures [Machine Learning a Variable Charge Atomistic Model for Cu/Hf Binary Alloy Oxide Heterostructures]

Alloy oxide heterostructures are essential for a wide variety of energy applications, including anticorrosion coatings, bifunctional catalysis, energy storage, as well as emerging platforms for multilevel nonvolatile memory and neuromorphic devices. The key role played by oxide composition, density, and stoichiometry in governing electrochemical reactions, interface structure, and ionic transport in alloy oxides remains largely unknown. This is primarily due to the lack of variable charge interatomic potential models that can adequately describe the various atomic/ionic interactions in alloy oxides within a unified framework. Here, we introduce a charge transfer ionic potential (CTIP) model for Cu/Hf/O alloy system and demonstrate its ability to accurately capture the complex potential energy surface owing to dynamically varying interactions, including metallic (Cu/Hf), ionic (Cu/Hf/Ox), mixed environment (interfaces). We leverage supervised machine learning methods powered by genetic algorithms coupled with local simplex optimization to efficiently navigate through a high-dimensional parameter space and identify an optimum set of an independent set of CTIP parameters. We train our model against an extensive first-principles based data set that includes lattice constants, cohesive energies, equations of state, and elastic constants of various experimentally observed polymorphs of hafnia, copper oxide, hafnium, as well as copper. Our machine-learned CTIP model captures the structure, elastic properties, thermodynamics, and energetic ordering of various polymorphs. It also accurately predicts the surface properties of both oxides and their metals. To demonstrate the suitability of our CTIP model for investigating dynamic processes, we employed it to identify the atomistic scale mechanisms associated with the initial nanoscale oxidation and surface oxide growth on Cu-doped hafnia surfaces. Here, our machine-learned CTIP model can be used to probe the dynamic response of Cu/Hf/O alloy interfaces subjected to external stimuli (e.g., electric field, pressure, temperature, strain, etc.) and a variety of atomistic phenomena including the dynamics of switching in emerging neuromorphic platforms.

36 MATERIALS SCIENCE↗

Multi-Level Optimal Power Flow Solver in Large Distribution Networks

Solving optimal power flow (OPF) problems for large distribution networks incurs high computational complexity. We consider a large multi-phase distribution network of tree topology with a deep penetration of active devices. We divide the network into collaborating areas featuring subtree topology and subareas featuring subsubtree topology. We design a multilevel implementation of the primal-dual gradient algorithm to solve the voltage regulation OPF problems while preserving nodal voltage information and topological information within areas and subareas. Numerical results on a 4,521-node system verify that the proposed algorithm can significantly improve the computational speed without compromising any optimality.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To damp harmonic resonance, this paper proposes an adaptive narrowband damping control that automatically programs, adds, and adjusts the damping around the oscillation frequency when an oscillation is detected. First, the paper presents a low-pass filter design for MMC control loops that pushes all negative damping of the MMC impedance down to the medium-frequency range (< ~ 1000 Hz). Then, an adaptive damping control that uses online oscillation detection is proposed, which can automatically configure the narrowband damper to provide positive damping to the MMC around the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper dynamically adjusts the damping gain and the width of the damping range based on continuous monitoring of system resonance conditions (e.g., adjust damping gain to zero when the system resonance disappears). Electromagnetic transient simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

InAs sidewall tunnel diodes enabled by surface states

Negative differential resistance (NDR), where the device current decreases with increasing bias voltage, is a representative phenomenon where quantum mechanics induces counterintuitive physical behavior and offers promising applications such as high-frequency oscillators, amplifiers, and multilevel logic circuits. While the NDR behavior has been extensively studied in various materials and devices, the role of surface properties in NDR, particularly in InAs-based diodes, remains underexplored. In this work, we report the observation of NDR in vertically structured InAs p + n diodes that exhibit a peak-valley current ratio of ∼6, which is suitably high for applications. Circumference-normalized current–voltage characterization revealed that the NDR originates from band-to-band tunneling between the valence band of p + -InAs and the conduction band of an n + -InAs surface, where the n + surface is due to surface states on otherwise n − -InAs. In addition, by comparing devices with various surface passivation methods (without intentional passivation, benzocyclobutene polymer, and silicon nitride), we found that the surface termination significantly affects the NDR characteristics. We present an equivalent circuit model to explain the observed device behavior. These findings offer insights into surface-enabled NDR phenomena and present new knobs for engineering NDR devices.

Circuit theorems↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter: Preprint

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To resolve it, this paper proposes an adaptive narrowband damping control that automatically programs, adds and adjusts damping around the oscillation frequency when detect the oscillation. The paper first presents a low-pass filter design for MMC control loops, which pushes all negative damping of MMC impedance down to the medium frequency range (< approximately 1000 Hz). This makes narrowband damping can be more targeted and easier to design because multiple harmonic oscillations are avoided. An adaptive damping control that uses online oscillation detection is then proposed, which can automatically configure the narrowband damper to provide damping to the MMC at the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper adjusts the damping gain (e.g., to zero when system resonance disappears) and the width of the damping range automatically based on continuous monitoring of system resonance conditions. Electromagnetic transient (EMT) simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗