Search NASA⌕ Search

SEARCH · Search NASA

Results for “NUCLEAR EMULSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

159 records · Page 9

Nucleus-nucleus interactions between 20 and 65 GeV per nucleon

A hybrid electronic-counter/emulsion-chamber instrument was exposed to high-energy cosmic rays on a balloon. The data on 105 nucleus-nucleus collisions in the energy range 20-65 GeV/nucleon and for incident nuclear charges Zp in the range of 22 to 28 are presented. Inclusive characteristics of particle production on different targets (plastic, emulsion, and lead) are shown and compared with models based on the superposition of nucleon-nucleus interactions. Features of a subset of the more central collisions with a plastic target and some characteristics of individual events with the highest multiplicity of produced particles are described.

Burnett, T. H.↗

Characteristics of central collision events in Fe-nucleus interactions for 20 - 60 GeV/nucleon

A counter emulsion hybrid chamber in Japanese-American Cooperative Emulsion Experiment (JACEE-3) was flown on a balloon at the altitude (5.4 g/sq cm) in 1982 with the objective of probing the heavy nuclear collisions above 20 GeV per nucleon. In the energy region, it is suggested that nucleus-nucleus collisions provide dense collisions complex through compression and secondary particle production. In the lower energy region, an evidence of collective flow has been reported. And also, at higher energy region, it has been argued that nucleus has rather large stopping power. In this paper, the high multiplicity characteristics of Fe nucleus central collisions with energies 20 to 50 GeV/nucleon are presented. This is considered to be relevant to compressibility and collective flow of nuclear matter.

Burnett, T. H.↗

Multiplicities of secondaries in nuclear interactions, induced by Ne-20, Ar-40 and Fe-56 nuclei at 0.1-0.5 GeV/nucleon

Multiplicities of various species of charged secondaries produced in inelastic interactions of Ne-20, Ar-40, and Fe-56 nuclei with emulsion nuclei, at 0.1-0.5 GeV/nucleon have been measured. The data obtained are compared with the results for interactions of higher energy nuclei with emulsion nuclei. The dependences of the nucleus-nucleus interaction parameters on masses and energies of colliding nuclei are examined.

Dudkin, V. E.↗

Fluctuation analysis of relativistic nucleus-nucleus collisions in emulsion chambers

An analytical technique was developed for identifying enhanced fluctuations in the angular distributions of secondary particles produced from relativistic nucleus-nucleus collisions. The method is applied under the assumption that the masses of the produced particles are small compared to their linear momenta. The importance of particles rests in the fact that enhanced fluctuations in the rapidity distributions is considered to be an experimental signal for the creation of the quark-gluon-plasma (QGP), a state of nuclear matter predicted from the quantum chromodynamics theory (QCD). In the approach, Monte Carlo simulations are employed that make use of a portable random member generator that allow the calculations to be performed on a desk-top computer. The method is illustrated with data taken from high altitude emulsion exposures and is immediately applicable to similar data from accelerator-based emulsion exposures.

Mcguire, Stephen C.↗

Analysis of relativistic nucleus-nucleus interactions in emulsion chambers

The development of a computer-assisted method is reported for the determination of the angular distribution data for secondary particles produced in relativistic nucleus-nucleus collisions in emulsions. The method is applied to emulsion detectors that were placed in a constant, uniform magnetic field and exposed to beams of 60 and 200 GeV/nucleon O-16 ions at the Super Proton Synchrotron (SPS) of the European Center for Nuclear Research (CERN). Linear regression analysis is used to determine the azimuthal and polar emission angles from measured track coordinate data. The software, written in BASIC, is designed to be machine independent, and adaptable to an automated system for acquiring the track coordinates. The fitting algorithm is deterministic, and takes into account the experimental uncertainty in the measured points. Further, a procedure for using the track data to estimate the linear momenta of the charged particles observed in the detectors is included.

Mcguire, Stephen C.↗

Nuclear composition

The results of direct measurements of the energy distribution and elemental composition of cosmic rays are reviewed. Consideration is given to early calorimeter, Cerenkov-counter, and superconducting-magnet data; HEAO-3 results; balloon-borne measurements beyond 30 GeV/nucleon, and the balloon-borne emulsion-chamber data obtained in the JACEE experiments (Burnett et al., 1982 and 1983). The potential of Space Station observations to extend the data to energies as high as 10 PeV is discussed.

Balasubrahmanyan, V. K.↗

Analysis of SOFCAL calibration data

Ionization calorimeters determine the total energy of a particle by absorbing, within the mass of the calorimeter, the entire energy of the particle or a significant (and determinable) fraction of it. The JACEE group has used passive ionization calorimetery, which employs photographic emulsions as the detector medium, to measure the charge composition and energy spectrum of cosmic rays up to, and exceeding, 10(exp 14)eV. The SOFIC approach depends similarly on the use of three-dimensional nuclear-electromagnetic shower theory to relate the ionization deposits obtained during a shower to the energy of the particle causing the shower. Bundles of thousands of scintillating optical fibers are read out using image-intensified CCD's. Such an event may be triggered by a fast shower detector placed under the instrument or if only heavy particles are of interest, from a fast primary Cerention detector placed above the calorimeter. In the first study, fast Hammatsu photomultiplier tubes were purchased and tested for possible application for a triggering purpose. In the second study, some refinements have been made to the theoretical treatment of hadronic interactions in the central collision region. These will be helpful in improving the simulations necessary for observations of high energy cosmic ray nuclei with a SOFIC.

Gregory, John C.↗

A note on the tissue star dose in personnel radiation monitoring in space

Secondaries from nuclear interactions of high energy primaries in the body tissues themselves contribute substantially to the astronaut's radiation exposure in space. The so-called tissue star dose is assessed from the prong number distribution of disintegration stars in emulsion. Prong counts of 1,000 emulsion stars from the Apollo-Soyuz mission reported earlier were re-evaluated. The original scores were divided into sets of 250, 500, 750, and 1,000 emulsion stars and the respective prong number distributions established. The statistical error of the gelatin star number for the four consecutively larger was found to vary, on the 67 percent confidence level, from + or - 25 percent for the count of 250 emulsion stars to + or - 11 percent for 1,000 stars. Seen in the context of the other limitations of the experimental design, the lowest effort of prong-counting 250 stars appears entirely appropriate.

Schaefer, H. J.↗

Spectra, composition and interactions of nuclei above 10 TeV using magnet-interferometric chambers (SCIN/MAGIC)

Initial definition studies were performed for the SCIN/MAGIC experiment selected as an Astromag investigation on Space Station Freedom. The study focused on Science Objectives and Science Requirement, Accommodation on both the STS and the Astromag facility, Data extraction techniques and Background Studies. The detectors are emulsion chambers which will be exposed for approximately 90 days and then recovered from orbit for subsequent processing and analysis in the laboratory. Such a technique is the only means to obtain information on the ultrahigh energy cosmic rays and their nuclear interactions. The SCIN/MAGIC investigation can supply unique data in relatively unexplored energy region and address many of the fundamental questions in particle astrophysics.

Wefel, John P.↗

Workshop on Cosmic Ray and High Energy Gamma Ray Experiments for the Space Station Era, Louisiana State University, Baton Rouge, October 17-20, 1984, Proceedings

The potential of the Space Station as a platform for cosmic-ray and high-energy gamma-ray astronomy is discussed in reviews, reports, and specific proposals. Topics examined include antiparticles and electrons, science facilities and new technology, high-energy nuclear interactions, nuclear composition and energy spectra, Space Shuttle experiments, Space Station facilities and detectors, high-energy gamma rays, and gamma-ray facilities and techniques. Consideration is given to universal-baryon-symmetry testing on the scale of galactic clusters, particle studies in a high-inclination orbit, balloon-borne emulsion-chamber results on ultrarelativistic nucleus-nucleus interactions, ionization states of low-energy cosmic rays, a large gamma-ray telescope for point-source studies above 1 GeV, and the possible existence of stable quark matter.

Jones, W. V.↗

Lateral distribution of high energy hadrons and gamma ray in air shower cores observed with emulsion chambers

A high energy event of a bundle of electrons, gamma rays and hadronic gamma rays in an air shower core were observed. The bundles were detected with an emulsion chamber with thickness of 15 cm lead. This air shower is estimated to be initiated with a proton with energy around 10 to the 17th power to 10 to the 18th power eV at an altitude of around 100 gmc/2. Lateral distributions of the electromagnetic component with energy above 2 TeV and also the hadronic component of energy above 6 TeV of this air shower core were determined. Particles in the bundle are produced with process of the development of the nuclear cascade, the primary energy of each interaction in the cascade which produces these particles is unknown. To know the primary energy dependence of transverse momentum, the average products of energy and distance for various average energies of secondary particles are studied.

Matano, T.↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

Neutrons, gamma rays, and beta particles interactions with IIaO films flown on Astro I and Astro II and comparison with IIaO flown on the get-away-special STS-7

The current requirements for the Laboratory for Astronomy and Solar Physics, sends rocket satellites and in the near future will involve flights in the shuttle to the upper reaches of the Earth's atmosphere where they will be subjected to the atomic particles and electromagnetic radiation produced by the Sun and other cosmic radiation. It is therefore appropriate to examine the effect of neutrons, gamma rays, beta particles, and X-rays on the film currently being used by the Laboratory for current and future research requirements. It is also hoped by examining these particles in their effect that we will have simulated the space environment of the rockets, satellites, and shuttles. Several samples of the IIaO film were exposed to a neutron howitzer with a source energy of approximately 106 neutrons/steradians. We exposed several samples of the film to a 10 second blast of neutrons in both metal and plastic containers which exhibited higher density readings which indicated the possibility of some secondary nuclear interactions between neutrons and the aluminum container. The plastic container showed some variations at the higher densities. Exposure of the samples of IIaO film to a neutron beam of approximately 10 neutrons per steradians for eight minutes produces approximately a 13% difference in the density readings of the dark density grids. It is not noticeable that at the lighter density grid the neutrons have minimal effects, but on a whole the trend of the eight minute exposed IIaO film density grids at the darker end had a 7.1% difference than the control. Further analysis is anticipated by increasing the exposure time. Two sets of film were exposed to a beta source in a plastic container. The beta source was placed at the bottom so that the cone of rays striking the film would be conical for a period of seven days. It was observed in the films, designated 4a and 4b, a dramatic increase in the grid densities had occurred. The attenuation of beta particles due to the presence of air were observed. The darker density grids, whose positions were the furthest from the beta source, displayed minimal fluctuations as compared with the control. It is suspected that the orientation of the film in the cansister with the beta source is the key factor responsible for the dramatic increases of the lighter density grids. Emulsions 3a and 3b exposed for a period of six days with the grid orientation reserved produced substantial differences in the darker grids as shown in the graphs. There is a great deal of fluctuations in this sample between the beta exposed density grids and the control density grids. The lighter density grids whose orientations were reversed displays minimal fluctuations due to the presence of this beta source and the attenuation that is taking place.

Hammond, Ernest C., Jr.↗