Search NASA⌕ Search

SEARCH · Search NASA

Results for “National Transonic Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An assessment of the future roles of the National Transonic Facility and the Langley Transonic Dynamics Tunnel in aeroelastic and unsteady aerodynamic testing

The characteristics and capabilities of the two tunnels, that relate to studies in the fields of aeroelasticity and unsteady aerodynamics are discussed. Scaling considerations for aeroelasticity and unsteady aerodynamics testing in the two facilities are reviewed, and some of the special features (or lack thereof) of the Langley Research Center Transonic Dynamics Tunnel (TDT) and the National Transonic Facility (NTF) that will weigh heavily in any decisions conducting a given study in the two tunnels are discussed. For illustrative purposes a fighter and a transport airplane are scaled for tests in the NTF and in the TDT, and the resulting model characteristics are compared. The NTF was designed specifically to meet the need for higher Reynolds number capability for flow simulation in aerodynamic performance testing of aircraft designs. However, the NTF can be a valuable tool for evaluating the severity of Reynolds number effects in the areas of dynamic aeroelasticity and unsteady aerodynamics. On the other hand, the TDT was constructed specifically for studies and tests in the field of aeroelasticity. Except for tests requiring the Reynolds number capability of NTF, the TDT will remain the primary facility for tests of dynamic aeroelasticity and unsteady aerodynamics.

Hanson, P. W.↗

Full scale aircraft simulation with cryogenic tunnels and status of the National Transonic Facility

The paper reviews the results of some of the real-gas studies made at Langley that are directly related to establishing the range of operating conditions that can be used in a cryogenic nitrogen wind tunnel and still be assured of valid full-scale simulation. Consideration is given to the important aerodynamic features, anticipated performance capability, status of construction, and projected operating data for the National Transonic Facility.

Kilgore, R. A.↗

Fifteen Years of Operation at NASA's National Transonic Facility with the World's Largest Adjustable Speed Drive

In September 1995, a project was initiated to replace the existing drive line at NASA's most unique transonic wind tunnel, the National Transonic Facility (NTF), with a single 101 MW synchronous motor driven by a Load Commutated Inverter (LCI). This Adjustable Speed Drive (ASD) system also included a custom four-winding transformer, harmonic filter, exciter, switch gear, control system, and feeder cable. The complete system requirements and design details have previously been presented and published [1], as well as the commissioning and acceptance test results [2]. The NTF was returned to service in December 1997 with the new drive system powering the fan. Today, this installation still represents the world s largest horizontal single motor/drive combination. This paper describes some significant events that occurred with the drive system during the first 15 years of service. These noteworthy issues are analyzed and root causes presented. Improvements that have substantially increased the long term viability of the system are given.

Sydnor, George H.↗

A Wall Correction Program Based on Classical Methods for the National Transonic Facility (Solid Wall or Slotted Wall) and the 14x22-Ft Subsonic Tunnel at NASA LaRC

A Fortran subroutine CMWALL is described, which is an implementation of the collective information from classical methods-based wall corrections. These methods use established closed-form expressions which were developed based on simple linear potential-based methods. This is a simple and rapid tool to calculate corrections due to wall interference in the National Transonic Facility (Solid Wall or Slotted Wall) or the 14x22-Ft Subsonic Tunnel at NASA LaRC. It is designed to be easily implemented in the existing tunnel data reduction programs, either as real-time or post-point. It is however important to realize that the method is based on the simplifying assumptions of linearity, small model and attached flow. The computed results are thus to be viewed as first-cut estimates, to be refined further using more complex methods based on measured wall pressures (known as wall signature methods).

Hemsch, Michael J.↗

NASA 5.2%-Scale High Lift Common Research Model (CRM-HL) Test in the National Transonic Facility (NTF)

Problem: Predicting CL,max and assessing transition, turbulence models, and Reynolds number effect predictions in CFD requires wind tunnel data for comparison. Objective: Expand the CFD validation database by running multiple models designed using the same reference geometry in various wind tunnels around the world. The wind tunnel data and model geometry will be open source to allow for CFD validation use. Approach: Run the NASA 5.2%-scale High Lift Common Research Model (CRM-HL) semi-span model at the National Transonic Facility (NTF). Test the model at chord Reynolds numbers (Rec) between 1.6 million and 30 million and at varying Q/Es to assess Reynolds number effects and aeroelasticity affects on the model, while collecting force and moment, pressure and wing deformation data. Test the model with ice shapes installed on the leading edges. Results: Ran eight model configurations, including four landing, two landing with ice shapes installed, and two takeoff configurations. Ran in air (120°F) and nitrogen operations (-50°F, -180°F and -250°F) at 7 different chord Reynolds numbers. The data compare well with previous tests of the same model at DLR (The Germany Aerospace Center) and the 14- by 22-Foot Subsonic Tunnel (14x22). Significance: Provided valuable high Reynolds number data on a high lift configuration to the worldwide research community. Provide icing data at flight Reynolds number to the research community.

CRM-HL↗

A comparison of two photogrammetric algorithms for the measurement of model deformation in the National Transonic Facility

A comparison was made of two photogrammetric measurement techniques which can be used for the determination of the spatial loctions of targets. One technique is known as the Direct Linear Transformation (DLT), and the other is referred to as the Bundle method. Each technique utilizes triangulation of image data from two or more cameras, but they differ in their method of determining camera parameters. While the study was performed with simulated data, the geometries, image data accuracies and other parameters were set to simulate conditions for a two-camera, photogrammetric system which will be used at the National Transonic Facility at the NASA's Langley Research Center. For the conditions studied the Bundle technique was found to have smaller errors. Both methods were sensitive to the spatial distribution of control-point targets, but this effected the accuracy of the Bundle algorithm less than that of the DLT algorithm.

Monteith, J. H.↗

Self-Aligned Focusing Schlieren at the 0.3-M Transonic Cryogenic Tunnel and the National Transonic Facility

The implementation of a self-aligned focusing schlieren (SAFS) system at two cryogenic wind tunnels at NASA Langley Research Center is discussed. Risk-reduction testing of the SAFS system was first performed at the 0.3-M Transonic Cryogenic Tunnel to evaluate the system’s operation in a small-scale characteristic cryogenic facility. Testing was conducted with three models: a three-quarter span 25.4-mm-diameter cylinder, a semi-span 65A006 tapered unswept airfoil, and a full-span SC(3)-0712 airfoil. Testing with the cylinder and semi-span airfoil revealed a highly dynamic shock environment, whereas the shock on the full-span airfoil was stationary, solidifying the usage of this model for a pre-/post-shock particle tracking velocimetry measurement. Temperature-induced polarization-altering window stresses were encountered during low-temperature testing and were mitigated using a “non-ideal” quartz/quartz Rochon prism that had largely been neglected since the SAFS system’s first introduction in favor of the more favorable “ideal” glass/quartz Rochon prism. The size of the SAFS system was then decreased in order to fit inside an environmentally controlled camera can enclosure at the National Transonic Facility (NTF) for testing of a sting-mounted aircraft model. The SAFS system was demonstrated to be effective at filtering out the large density gradient flow in the0.3-M plenum, and the thick, high density turbulent boundary layers on the wind tunnel walls at the NTF. Results of the testing campaigns and improvements to future systems are discussed.

Joshua M Weisberger↗

Self-Aligned Focusing Schlieren at the 0.3-M Transonic Cryogenic Tunnel and the National Transonic Facility

The implementation of a self-aligned focusing schlieren (SAFS) system at two cryogenic wind tunnels at NASA Langley Research Center is discussed. Risk-reduction testing of the SAFS system was first performed at the 0.3-M Transonic Cryogenic Tunnel to evaluate the system’s operation in a small-scale characteristic cryogenic facility. Testing was conducted with three models: a three-quarter span 25.4-mm-diameter cylinder, a semi-span 65A006 tapered unswept airfoil, and a full-span SC(3)-0712 airfoil. Testing with the cylinder and semi-span airfoil revealed a highly dynamic shock environment, whereas the shock on the full-span airfoil was stationary, solidifying the usage of this model for a pre-/post-shock particle tracking velocimetry measurement. Temperature-induced polarization-altering window stresses were encountered during low-temperature testing, and were mitigated using a “non-ideal” quartz/quartz Rochon prism that had largely been neglected since the SAFS system’s first introduction in favor of the more favorable “ideal” glass/quartz Rochon prism. The size of the SAFS system was then decreased in order to fit inside an environmentally-controlled camera can enclosure at the National Transonic Facility (NTF) for testing of a sting-mounted aircraft model. The SAFS system was demonstrated to be effective at filtering out the large density gradient flow in the 0.3-M plenum, and the thick, high density turbulent boundary layers on the wind tunnel walls at the NTF. Results of the testing campaigns and improvements to future systems are discussed.

Joshua M. Weisberger↗

Statistical Calibration and Validation of a Homogeneous Ventilated Wall-Interference Correction Method for the National Transonic Facility

Wind tunnel experiments will continue to be a primary source of validation data for many types of mathematical and computational models in the aerospace industry. The increased emphasis on accuracy of data acquired from these facilities requires understanding of the uncertainty of not only the measurement data but also any correction applied to the data. One of the largest and most critical corrections made to these data is due to wall interference. In an effort to understand the accuracy and suitability of these corrections, a statistical validation process for wall interference correction methods has been developed. This process is based on the use of independent cases which, after correction, are expected to produce the same result. Comparison of these independent cases with respect to the uncertainty in the correction process establishes a domain of applicability based on the capability of the method to provide reasonable corrections with respect to customer accuracy requirements. The statistical validation method was applied to the version of the Transonic Wall Interference Correction System (TWICS) recently implemented in the National Transonic Facility at NASA Langley Research Center. The TWICS code generates corrections for solid and slotted wall interference in the model pitch plane based on boundary pressure measurements. Before validation could be performed on this method, it was necessary to calibrate the ventilated wall boundary condition parameters. Discrimination comparisons are used to determine the most representative of three linear boundary condition models which have historically been used to represent longitudinally slotted test section walls. Of the three linear boundary condition models implemented for ventilated walls, the general slotted wall model was the most representative of the data. The TWICS code using the calibrated general slotted wall model was found to be valid to within the process uncertainty for test section Mach numbers less than or equal to 0.60. The scatter among the mean corrected results of the bodies of revolution validation cases was within one count of drag on a typical transport aircraft configuration for Mach numbers at or below 0.80 and two counts of drag for Mach numbers at or below 0.90.

Walker, Eric Lee↗

Statistical Calibration and Validation of a Homogeneous Ventilated Wall-Interference Correction Method for the National Transonic Facility

Wind tunnel experiments will continue to be a primary source of validation data for many types of mathematical and computational models in the aerospace industry. The increased emphasis on accuracy of data acquired from these facilities requires understanding of the uncertainty of not only the measurement data but also any correction applied to the data. One of the largest and most critical corrections made to these data is due to wall interference. In an effort to understand the accuracy and suitability of these corrections, a statistical validation process for wall interference correction methods has been developed. This process is based on the use of independent cases which, after correction, are expected to produce the same result. Comparison of these independent cases with respect to the uncertainty in the correction process establishes a domain of applicability based on the capability of the method to provide reasonable corrections with respect to customer accuracy requirements. The statistical validation method was applied to the version of the Transonic Wall Interference Correction System (TWICS) recently implemented in the National Transonic Facility at NASA Langley Research Center. The TWICS code generates corrections for solid and slotted wall interference in the model pitch plane based on boundary pressure measurements. Before validation could be performed on this method, it was necessary to calibrate the ventilated wall boundary condition parameters. Discrimination comparisons are used to determine the most representative of three linear boundary condition models which have historically been used to represent longitudinally slotted test section walls. Of the three linear boundary condition models implemented for ventilated walls, the general slotted wall model was the most representative of the data. The TWICS code using the calibrated general slotted wall model was found to be valid to within the process uncertainty for test section Mach numbers less than or equal to 0.60. The scatter among the mean corrected results of the bodies of revolution validation cases was within one count of drag on a typical transport aircraft configuration for Mach numbers at or below 0.80 and two counts of drag for Mach numbers at or below 0.90.

Walker, Eric L.↗

Instrumentation systems for the National Transonic Facility

Instrumentation and measurement systems designs to achieve high Reynolds number test are discussed. The national transonic tunnel with its unique operational characterisics is a complex facility and represents a significant challenge to wind tunnel instrument designers. The instrument requirements imposed by the new testing environment, the instrument systems provided for facility calibration and operation, and the research and development activities directed at meeting overall instrument and measurement requirements are described.

Guarino, J. F.↗