Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Radioactivity and neutron damage calculators for research and test reactor neutron-activated materials - 25652

The Idaho National Laboratory Nuclear Science User Facilities program is proposing to launch a new online expert system that will assist users in planning experiments and writing proposals. The Combined Materials Experimentation Toolkit (CoMET) will include two nuclear calculators. The first of these, the Neutron Damage Calculator, will assist users in selecting reactor positions in order to obtain desired material damage in Damage Per Atom (DPA) and provide the required irradiation time to reach the damage levels. The second, the Radioactivity Calculator, will estimate the post-irradiation radioactivity levels of sample materials, which will inform technical staff of examination facility requirements and any potential scheduling delays. Both of these calculators were designed to simplify the information needed from users in order to properly plan and execute awarded proposals. This paper presents the primary purpose and methodologies implemented by these two calculators. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ORNL Laboratory Directed Research and Development Program FY 2008 Annual Report

The Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD) Program reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries all ORNL LDRD research activities supported during FY 2008. The associated FY 2008 ORNL LDRD Self-Assessment (ORNL/PPA-2008/2) provides financial data and an internal evaluation of the program’s management process.

08 HYDROGEN↗

ORNLs Laboratory Directed Research and Development Program (FY 2009 Annual Report)

The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries all ORNL LDRD research activities supported during FY 2009. The associated FY 2009 ORNL LDRD Self-Assessment (ORNL/PPA-2010/2) provides financial data and an internal evaluation of the program’s management process.

36 MATERIALS SCIENCE↗

ORNLs Laboratory Directed Research and Development Program FY 2010 Annual Report

The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries of all ORNL LDRD research activities supported during FY 2010. The associated FY 2010 ORNL LDRD Self-Assessment (ORNL/PPA-2011/2) provides financial data and an internal evaluation of the program’s management process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ORNLs Laboratory Directed Research and Development Program (FY 2011 Annual Report)

The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries of all ORNL LDRD research activities supported during FY 2011. The associated FY 2011 ORNL LDRD Self-Assessment (ORNL/PPA-2012/2) provides financial data and an internal evaluation of the program’s management process.

09 BIOMASS FUELS↗

ORNLs Laboratory Directed Research and Development Program (FY 2012 Annual Report)

The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the US Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries of all ORNL LDRD research activities supported during FY 2012. The associated FY 2012 ORNL LDRD Self-Assessment (ORNL/PPA-2012/2) provides financial data and an internal evaluation of the program’s management process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ORNLs Laboratory Directed Research and Development Program FY 2013 Annual Report

The Laboratory Directed Research and Development (LDRD) program at Oak Ridge National Laboratory (ORNL) reports its status to the US Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries of all ORNL LDRD research activities supported during FY 2013. The associated FY 2013 ORNL LDRD Self-Assessment (ORNL/PPA-2014/2) provides financial data and an internal evaluation of the program’s management process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High temperature neutron diffraction investigation of U 3 Si 2

The U-Si system is actively undergoing studies due to its promise as a component of an accident tolerant nuclear fuel. In this work, the crystal structure of the U 3 Si 2 compound in the U-Si system was investigated as a function of temperature from room temperature to 1298 K for a sample of approximately 42.02 at.% Si composition and 1373 K for a sample with approximately 42.10 at.% Si using high temperature time-of-flight neutron diffraction on the High-Pressure Preferred Orientation (HIPPO) diffractometer at Los Alamos Neutron Science Center (LANSCE). The simultaneous Rietveld refinement of five histograms from the five HIPPO detector backs (40°, 60°, 90°, 120°, and 145°) provided datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of a homogeneity range, two sample compositions were analyzed, a 40.02 at.% Si (near stoichiometric) and a potentially hyperstoichiometric (40.10 at.% Si) sample. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were found indicative of a single phase sample and the ability of the U 3 Si 2 compound to accommodate nonstoichiometry, suggesting that the U 3 Si 2 compound is not a line compound confirming previous determinations. However, the differences observed in the average coefficient of linear thermal expansion identified between the two compositions warrant future investigation.

36 MATERIALS SCIENCE↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Neutronics for diagnostics in ITER - Paper 121

ITER, currently under construction in the south of France, will be the first tokamak producing large amounts of neutrons and having a fusion energy gain factor, which is the ratio between the fusion power produced and the input power necessary to maintain the plasma, greater than 10. ITER will be able to generate 500 MW of fusion power, from which 400 MW are 14.1 MeV neutrons from the Deuterium-Tritium fusion reactions in the thermonuclear plasma. For such nuclear machine neutronics are of paramount importance, being a design driver for many of its components, in particular its Ports and its numerous Diagnostics, for which the influence of neutronics is especially important in three main areas: - Shielding: there is a strong need to provide nuclear shielding to areas where human access is foreseen for maintenance. Also, to minimize any impact in the primary shielding components (blankets) in order to avoid significant increases in the heating of the Vacuum Vessel (VV) and Superconductive Coils. - Sensors and diagnostic components: most of the diagnostics have sensitive components that need to be shielded against radiation to survive. Efficient shielding is not always possible, and the radiation levels are usually the decisive factor for selecting the most appropriate component. - Neutron measurements: a large set of neutron diagnostics will be implemented to measure the neutron production and its emissivity profile. Although the scale and performance of ITER will not be very far from a commercial reactor, it is ultimately an experiment to improve the understanding of reactor-grade tokamak plasmas and their effect on plasma facing components. To accomplish this task, large efforts are being dedicated to design over 45 different diagnostics systems. This paper gives an overview of the main activities related to neutronics within the ITER Diagnostics Division. They include the neutron streaming problems in the Ports and the common neutronics issues of the diagnostics housed inside them, as well as the challenges of the in vessel diagnostics. Also the special calculations needed for the neutron diagnostics. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental validation of an integrated modelling approach to neutron emission studies at JET

An integrated modelling methodology for the calculation of realistic plasma neutron sources for the JET tokamak has been developed. The computational chain comprises TRANSP plasma transport and DRESS neutron spectrum calculations, and their coupling to the MCNP neutron transport code, bridging plasma physics and neutronics. Here, we apply the developed methodology to the analysis of neutron emission properties of deuterium and helium plasmas at JET, and validate individual modelling steps against neutron diagnostic measurements. Two types of JET discharges are modelled—baseline-like and three-ion radio-frequency scenarios—due to their diversity in plasma heating, characteristics of the induced fast ion population, and the imprint of these on neutron emission properties. The neutron emission modelling results are quantitatively compared to the total neutron yield from fission chambers, neutron emissivity profiles from the neutron camera, neutron spectra from the time-of-flight spectrometer, and neutron activation measurements. The agreement between measured and calculated quantities is found to be satisfactory for all four diagnostic systems within the estimated experimental and computational uncertainties. Additionally, the effect of neutrons not originating from the dominating D(D, n) 3 He reactions is studied through modelling of triton burnup DT neutrons, and, in mixed D- 3 He plasmas, neutrons produced in the 9 Be(D, nγ) 10 B reaction on impurities. It is found that these reactions can contribute up to several percent to the total neutron yield and dominate the neutron activation of samples. Finally, the effect of MeV-range fast ions on the neutron activation of 115 In and 27 Al samples is measured and computationally validated.

integrated modelling↗

Gramicidin and chlorhexidine encapsulated in bicontinuous microemulsions: Antimicrobial activity performance and their impact on self‐assembly

The utility of bicontinuous microemulsions (BMEs) as carriers of the antimicrobial peptide (AMP) gramicidin D and antiseptic chlorhexidine was investigated for possible topical delivery to chronic wounds. The two water-insoluble solutes dissolved in pre-formed one-phase BMEs of Water/Polysorbate 80/Limonene/Ethanol/Glycerol and Water/Aerosol-OT (AOT)/Polysorbate 85/Isopropyl Myristate and an AOT/Polysorbate 85 Winsor-III system, achieving gramicidin and chlorhexidine concentrations of 1.0 wt% and 0.5% individually and 0.5% and 0.3% in mixtures at 22°C, respectively. Small-angle neutron scattering measurements demonstrated that both solutes decreased surfactant interfacial activity and increased interfacial fluidity for the Polysorbate 80 system. For the AOT/Polysorbate 85 systems, ellipsoidal aggregates consisting of gramicidin and likely adsorbed surfactant and oil formed, while chlorhexidine enhanced the surface activity of surfactants. According to bioassays performed on artificial skin, the incorporation of melittin, gramicidin, and chlorhexidine in general enhanced the bioactivity of Polysorbate 80 BMEs for 24 h treatment against relevant antibiotic-resistant bacteria found on skin relative to controls. Yet, BME treatments were less effective than aqueous melittin control, in contrast to well diffusion bioassays performed previously. The results reflect the strong impact of AMPs and antiseptics on BME structure and dynamics and the complexity of formulating BMEs for optimal antimicrobial activity.

antimicrobial peptides↗

Design And Performance Of A 3 MV Tandetron Accelerator System For High-Current Applications

The Saha Institute of Nuclear Physics, Kolkata, India will commission in 2011 a 3 MV Tandetron accelerator system. Hi-flux neutron production, nuclear reaction cross-section measurements and time of flight experiments are among the research activities to be performed with this system. Features such as high beam currents, high beam energy stability and low beam energy spread are necessary when conducting these types of experiments. At the same time, the beam energy must be known with high accuracy. This article reports the early results obtained during the in-house testing of the system. H beam currents of 500 {mu}A have been transported through the system. The so-called ''Q-snout'' electrode lens ensures high particle transmission ({approx}70%) through the accelerator even at 7% of the rated terminal voltage (TV). At present, the negative H ion beam current output of the SO120 multicusp ion source, rated at only 2 mA, combined with the Tandetron accelerators (with terminal voltage ranging from 1 to 6 MV) provides H beam powers of up to 10 kW.

43 PARTICLE ACCELERATORS↗

Investigating the non-ideal behavior of the Amptek A111 charge sensitive preamplifier & discriminator board— 3 He proportional counter combination used in common safeguards neutron coincidence counters

Neutron coincidence counting is a well-established technique used for the nondestructive quantification of specialnuclear material during international safeguards inspections. The neutron counters are commonly designedwith an annular body, centered about an inner well or cavity into which a measurement item is placed,and the moderating annulus is populated with 3 He tubes connected to a varying number of preamplifiers.The Canberra Industries JAB-01 preamplifier/amplifier/discriminator board is employed within the company’sneutron coincidence counters, built for use by the International Atomic Energy Agency. Non-ideal behavior ofthese boards was identified during a detector characterization, using list mode data acquisition, of a CanberraIndustries JCC-71 Neutron Coincidence Collar implementing four JAB-01 boards. List mode data acquisition andanalysis reveals features that have commonly been overlooked by historic timing gate selection while using shiftregister data acquisition methods, which are routinely adopted in international safeguards. It has been shownthat double pulsing effects are not fully captured within the predelay setting; therefore, they may influencethe response of the system within the standard operating regime. We set out to identify and correct for doublepulsing in our post analysis of neutron pulse trains, while isolating this behavior to the relevant system. Tounderstand and potentially address these concerns, the responses of two different JAB-01 board systems – theJCC-71 Neutron Coincidence Collar and a modified JCC-51 Active Well Neutron Coincidence Counter – arecompared with the responses of an AnTech Inc. N2071 Neutron Coincidence Collar that also uses an amplifierbuilt on the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip, and a JCC-71 that employs custompreamplifiers designed at Oak Ridge National Laboratory

42 ENGINEERING↗