Search NASA⌕ Search

SEARCH · Search NASA

Results for “NonDestructive Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

CHARACTERIZING AND MODELING FERRITE-CORE PROBES

In this paper, we accurately and carefully characterize a ferrite-core probe that is widely used for aircraft inspections. The characterization starts with the development of a model that can be executed using the proprietary volume-integral code, VIC-3D(c), and then the model is fitted to measured multifrequency impedance data taken with the probe in freespace and over samples of a titanium alloy and aluminum. Excellent results are achieved, and will be discussed.

36 MATERIALS SCIENCE↗

INNOVATIVE EDDY CURRENT PROBE FOR MICRO DEFECTS

This paper reports the development of an innovative eddy current (EC) probe, and its application to micro-defects on the root of the Friction Stir Welding (FSW). The new EC probe presents innovative concept issues, allowing 3D induced current in the material, and a lift-off independence. Validation experiments were performed on aluminium alloys processed by FSW. The results clearly show that the new EC probe is able to detect and sizing surface defects about 60 microns depth.

36 MATERIALS SCIENCE↗

Status and evolution of the ESRF beamline ID19

The ESRF synchrotron beamline ID19, dedicated to full-field parallel-beam imaging techniques such as phase-contrast and absorption microtomography and X-ray topography, is one of the most versatile instruments of its kind. This paper presents key characteristics of ID19 in its present form, names examples for research and development performed on the beamline, and outlines the plans for an upgrade on the beamline in coming years, to adapt to the growing needs of the user community. The technical goals envisioned include an increase in available beam size and maximum photon energy, and a substantial increase in flux density for applications using beams of small and intermediate size.

43 PARTICLE ACCELERATORS↗

A Spectral Element Approach for Modeling of Wave-Based Structural Health Monitoring Systems

During the last decades, guided waves have shown great potential for Structural Health Monitoring (SHM) applications. These waves can be excited and sensed by piezoelectric elements that can be permanently attached onto a structure offering online monitoring capability. As the setup of wave based SHM systems may be very difficult and time consuming there is a growing demand for efficient simulation tools providing the opportunity to design wave based SHM systems in a virtual environment. As usually high frequency waves are used, the associated short wavelength leads to the necessity of a very dense mesh, which makes conventional finite elements not well suited for this purpose. Therefore a flat shell spectral element approach is presented in this contribution. By including electromechanical coupling an SHM system can be simulated entirely from actuator voltage to sensor voltage. The focus of this contribution is the analysis of the effect of delaminations on propagating waves. A forward increment Lagrange multiplier method is used to simulate contact within the delaminated area. A model validation is performed using measured data of an anisotropic CFRP-plate.

36 MATERIALS SCIENCE↗

Development and setting of a new system for advanced rheocast components

This paper presents an overview of alternative methods of production of enhanced performance Al-based alloys components for critical areas. In particular, a new rheocasting system, suitable for the manufacturing of high performance industrial components has been considered. The aforementioned method allows obtaining component quickly and results a more convenient process, from economical point of view than other innovative processes. Two series of components have been produced with A356 and A357 alloys, then have been heat treated using T5 and T6 treatments. On polished transverse sections of samples the microstructure of the alloy has been observed. Their soundness has been previously certified by non destructive tests. Samples for tensile and three point bending tests have been machined directly from the produced components. On the fractured samples, fracture surface analysis has been performed in order to analyze and evaluate the influence of the process and of the alloy on the fracture behaviour.

36 MATERIALS SCIENCE↗

Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems

The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNR{sub max} depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.

07 ISOTOPE AND RADIATION SOURCES↗

High-Power, Kilojoule Class Laser Channeling in Millimeter-Scale Underdense Plasma

Experiments were performed using the Omega EP laser, operating at 740 J of energy in 8 ps (90 TW), which provides extreme conditions relevant to fast ignition studies. A carbon and hydrogen plasma plume was used as the underdense target and the interaction of the laser pulse propagating and channeling through the plasma was imaged using proton radiography. The early time expansion, channel evolution, filamentation, and self-correction of the channel was measured on a single shot via this method. A channel wall modulation was observed and attributed to surface waves. After around 50 ps, the channel had evolved to show bubblelike structures, which may be due to postsoliton remnants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Imaging of Surface Motion with a Stereo Borescope

A new stereo borescope has been investigated that would provide a time-resolved calibrated method of recording the motion and deformation of a three-dimensional (3-D) surface during explosively driven dynamic shock experiments at the Nevada Test Site. In these experiments, geometries would likely prove to be incompatible with conventional direct optical systems. Single line-of-sight borescopes lack adequate depth-of-field for quantitative imaging of the 3-D surface. To improve depth-of-field and provide time resolution, a stereo borescope has been fabricated for use with a nine-frame framing camera. At one end, stereo optics couple light from the dynamic surface into a pair of flexible 1-mm-diameter correlated fiber-optic bundles. At the other end, small-format lenses (~3 mm) interface with the framing camera, which is set up to simultaneously record the separate-perspective views. All nine frames could be recorded in a period as short as 1.8 μs, and spatial resolution is optimized to 11 line-pairs per mm. To achieve pseudo 3-D depth perception, photogrammetric analysis has been demonstrated with commercial software from ADAM technology (Australia). This paper presents the results from time-resolved stereo images of dynamic surfaces collected in a series of high-explosives experiments at the National Security Technologies, LLC, “Boom Box” in Santa Barbara, CA. Experience with the stereo borescope has suggested other potentially useful stereoscopic applications, such as stereo viewing of moving surfaces on the interiors of engines and the heating of moving components, and the viewing material deposition on interior surfaces during machine operations and fabrication processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

Nondestructive characterization of as-fabricated composite ceramic panels

Decreasing the weight of protective systems, while minimizing the decrease in ballistic performance, is an ongoing goal of the Army. Ceramic materials are currently combined with other materials in these types of structures in order to decrease weight without losing ballistic performance. This includes structures in which the ceramic material is confined in some way and in which the ceramic material is completely encapsulated. Confinement or encapsulation of ceramic material within a structure generally adds complexity and cost. Relatively simple panel specimens fabricated with ceramic tiles on aluminum backings and side confinement using steel were evaluated using nondestructive methods, including x-ray computed tomography and ultrasonic testing. The nondestructive evaluation results will be discussed and compared, including the detectability and mapping of fabrication features.

07 ISOTOPE AND RADIATION SOURCES↗

TIME-SEQUENCED X-RAY OBSERVATION OF A THERMAL EXPLOSION

The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 mus. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting front within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of mus after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

REAL TIME ULTRASONIC ALUMINUM SPOT WELD MONITORING SYSTEM

Aluminum alloys pose several properties that make them one of the most popular engineering materials: they have excellent corrosion resistance, and high weight-to-strength ratio. Resistance spot welding of aluminum alloys is widely used today but oxide film and aluminum thermal and electrical properties make spot welding a difficult task. Electrode degradation due to pitting, alloying and mushrooming decreases the weld quality and adjustment of parameters like current and force is required. To realize these adjustments and ensure weld quality, a tool to measure weld quality in real time is required. In this paper, a real time ultrasonic non-destructive evaluation system for aluminum spot welds is presented. The system is able to monitor nugget growth while the spot weld is being made. This is achieved by interpreting the echoes of an ultrasound transducer located in one of the welding electrodes. The transducer receives and transmits an ultrasound signal at different times during the welding cycle. Valuable information of the weld quality is embedded in this signal. The system is able to determine the weld nugget diameter by measuring the delays of the ultrasound signals received during the complete welding cycle. The article presents the system performance on aluminum alloy AA6022.

36 MATERIALS SCIENCE↗

DETECTION OF DISBONDING IN GLARE COMPOSITES USING LAMB WAVE APPROACH

Lamb-waves can be used to detect disbonds in composite plates. In this work, a photoacoustic technique was first applied to measure the dispersive property of a GLAss-REinforced (GLARE) composite panel. The measured phase velocity dispersion curves are consistent with the theoretical calculation using the classical transfer matrix method for layered media. Based on the obtained properties, a finite element method (FEM) model was constructed to study the influence of a disbond void on the Lamb wave propagation in the GLARE plate. It is found that the displacement amplitudes of the A{sub o} mode Lamb wave decrease while its travel time increases as the disbond size increases.

36 MATERIALS SCIENCE↗

STUDY OF AGING EFFECTS IN 2205 DUPLEX STAINLESS STEEL USING THERMOELECTRIC POWER MEASUREMENT

Thermoelectric power (TEP) measurements have been used as an effective method for evaluating the metallurgical state of various alloys. In the steel industry, some fabrication processes promote phase transformation and second phase precipitations which affect the material properties. Assessment of mechanical properties is critical in order to ensure quality of components. This work was conducted in order to evaluate the influence of the aging state of 2205 duplex stainless steel on TEP values. Commercial 2205 duplex steel was isothermally aged at 650 deg. C 700 deg. C and 900 deg. C at different aging times. TEP measurement technique was applied as a non destructive assessment technique to characterize the aging kinetics of the aged 2205 duplex stainless steel, hardness Rockwell (RC) and Charpy impact test were preformed to observe the effect of aging time on the specimens. Metallographic analysis was used to monitor phase transformation and sigma phase precipitation caused by the spinodal decomposition process of ferrite into secondary austenite and sigma phase. Results indicate that that the TEP is sensitive to gradual microstructural changes produced by the aging treatments.

36 MATERIALS SCIENCE↗

RELIABLE RADIOGRAPHIC INSPECTION OF FLEXIBLE RISERS FOR THE OIL INDUSTRY

Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segment protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.

36 MATERIALS SCIENCE↗

ANALYSIS OF IMPACT DAMAGE USING LINE SCANNING THERMOGRAPHY

Impact damage in a composite shaft was studied using Line Scanning Thermography (LST), a novel dynamic thermography technique capable of inspecting large areas in short times. It is expected that projectile impact in a laminate composite will generate a discontinuity that affects heat propagation. Therefore, as heat is deposited over the impacted region, a hot spot will be observed. In this study several impact points were evaluated using UT and LST. Experiments show that assessing impact damage using LST is a dynamic process, which should be accounted for when using dynamic thermography to quantify impact damage extension and severity. The LST images provided information about the region affected by impact damage, which was consistent with the damage region determined using UT. It is seen that the damage areas obtained at early observation time after heat application show small areas with severe damage; and for further times after heat application, the temperature of the hot spots drops and the size of the region affected increases with time following a linear relationship with the observation time.

42 ENGINEERING↗

INFRARED IMAGING OF CARBON AND CERAMIC COMPOSITES: DATA REPRODUCIBILITY

Infrared NDE techniques have proven to be superior for imaging of flaws in ceramic matrix composites (CMC) and carbon silicon carbide composites (C/SiC). Not only can one obtain accurate depth gauging of flaws such as delaminations and layered porosity in complex-shaped components such as airfoils and other aeronautical components, but also excellent reproducibility of image data is obtainable using the STTOF (Synthetic Thermal Time-of-Flight) methodology. The imaging of large complex shapes is fast and reliable. This methodology as applied to large C/SiC flight components at the NASA Dryden Flight Research Center will be described.

36 MATERIALS SCIENCE↗