Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Covariance Evaluation Work at LANL

Los Alamos evaluates covariances for nuclear data library, mainly for actinides above the resonance regions and light elements in the enUre energy range. We also develop techniques to evaluate the covariance data, like Bayesian and least-squares fitting methods, which are important to explore the uncertainty information on different types of physical quantities such as elastic scattering angular distribution, or prompt neutron fission spectra. This paper summarizes our current activities of the covariance evaluation work at LANL, including the actinide and light element data mainly for the criticality safety study and transmutation technology. The Bayesian method based on the Kalman filter technique, which combines uncertainties in the theoretical model and experimental data, is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probabilistic Economic Valuation of Safety Margin Management

The goal of this project was to explore a new methodology for evaluation of potential safety margin upgrades to add a new instrument to the Risk Informed Safety Margin Characterization (RISMC) toolkit. To this end, the RAVEN code developed by the Idaho National Laboratory was used to perform a cost-benefit analysis of several potential power plant safety upgrades to compare the material cost of the upgrades with the probabilistic benefit of avoiding accident scenario consequences to find the most cost-effective safety upgrades. By coupling RAVEN to MELCOR to drive Monte-Carlo method stochastic parameter analysis and using data from existing nuclear codes, as well as MELCOR’s radionuclide relocation tracking capabilities, the radionuclide release source term activity in a severe accident scenario can be estimated. Severe Accident Mitigation upgrades were benchmarked against the Hardened Containment Ventilation upgrade mandated by the USNRC for Mk1 BWRs using dollars spent per Curie of release prevented as a metric by which to evaluate the economic efficacy of the upgrades. Additionally, Fault Tree/Event Tree-based analyses were performed to compare older methods of evaluation to the methodology pioneered in this work, and Monthly Operating Report (MORP) outage data was analyzed for insights into power plant outage optimization and reduction.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Environmental Cracking and Irradiation Resistant Stainless Steels by Additive Manufacturing

Metal additive manufacturing (AM), or metal 3D printing is an emergent advanced manufacturing method that can create near net shape geometries directly from computer models. This technology can provide the capability to rapidly fabricate complex parts that may be required to enhance the integrity of reactor internals components. Such opportunities may be observed during a plant refueling outage and AM parts can be rapidly custom designed, manufactured and deployed within the outage interval. Additive manufacturing of stainless steel (SS) components can add business benefits on fast delivery on repair hardware, installation tooling, new design prototypes tests, etc. For the nuclear industry, the supply chain is always an issue for reactor service. AM can provide through-life supply chain (40-60 years) for high-value low-volume components. In the meantime, the capability of generating complex geometries and functional gradient materials will improve the performance, reduce the overall component cost, plant asset management cost and increase the plant reliability by the improvement in materials performance in nuclear environments. While extensive work has been conducted regarding additively manufacturing of austenitic SS parts, most efforts focused only on basic attributes such as porosity, residual stress, basic tensile properties, along with components yield and process monitoring. Little work has been done to define and evaluate the material requirements for nuclear applications. Technical gaps exist, which limit this technology adoption in the nuclear industry, which includes high manufacturing cost, unknown risks, limited nuclear related data, lack of specification and qualification methods, and no prior business experience. The main objective of this program was to generate research data to address all these technical gaps and establish a commercial practice to use AM technology in the nuclear power industry. The detailed objectives are listed as follows: (1) Evaluate nuclear related properties of AM 316L SS, including microstructure, tensile properties, impact toughness, stress corrosion cracking (SCC), corrosion fatigue (CF), irradiation effects, and irradiation assisted stress corrosion cracking (IASCC). (2) Understand the correlations among laser processing, heat treatment, microstructure and SCC/irradiation properties; (3) Optimize and improve the manufacturing process to achieve enhanced nuclear application properties; (4) Fabricate, evaluate, qualify and test a prototype reactor component to demonstrate the commercial viability and cost benefit; (5) Create regulatory approval path and commercialization plans for the production of a commercial reactor component.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detection and Calibration of Low-Energy Nuclear Recoils for Dark Matter and Neutrino Scattering Experiments

Detection of low-energy nuclear recoil events plays a central role in searches for particle dark matter interactions with atomic matter and studies of coherent neutrino scatters. Precise nuclear recoil calibration data allow the responses of these dark matter and neutrino detectors to be characterized and enable in situ evaluation of an experiment's sensitivity to anticipated signals. This article reviews the common methods for detection of nuclear recoil events and the wide variety of techniques that have been developed to calibrate detector response to nuclear recoils. We summarize the main experimental factors that are critical for accurate nuclear recoil calibrations, investigate mitigation strategies for different backgrounds and biases, and discuss how the presentation of calibration results can facilitate comparison between experiments. Lastly, we discuss the challenges for future nuclear recoil calibration efforts and the physics opportunities they may enable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-shielding models of MICROX-2 code

The MICROX-2 is a transport theory code that solves for the neutron slowing-down and thermalization equations of a two-region lattice cell. In the previous study, a new fine-group cross section library of the MICROX-2 was generated and tested against reference calculations and measurement data. In this study, existing physics models of the MICROX-2 are reviewed and updated to improve the physics calculation performance of the MICROX-2 code, including the resonance self-shielding model and spatial self-shielding factor. The updated self-shielding models have been verified through a series of benchmark calculations against the Monte Carlo code, using homogeneous and pin cell models selected for this study. The results have shown that the updates of the self-shielding factor calculation model are correct and improve the physics calculation accuracy even though the magnitude of error reduction is relatively small. Compared to the existing models, the updates reduced the prediction error of the infinite multiplication factor by approximately 0.1 % and 0.2% for the homogeneous and pin cell models, respectively, considered in this study. (authors)

97 MATHEMATICS AND COMPUTING↗

Monte Carlo analysis of thermochromatography as a fast separation method for nuclear forensics

Nuclear forensic science has become increasingly important for global nuclear security, and enhancing the timeliness of forensic analysis has been established as an important objective in the field. New, faster techniques must be developed to meet this objective. Current approaches for the analysis of minor actinides, fission products, and fuel-specific materials require time-consuming chemical separation coupled with measurement through either nuclear counting or mass spectrometry. These very sensitive measurement techniques can be hindered by impurities or incomplete separation in even the most painstaking chemical separations. High-temperature gas-phase separation or thermochromatography has been used in the past for the rapid separations in the study of newly created elements and as a basis for chemical classification of that element. This work examines the potential for rapid separation of gaseous species to be applied in nuclear forensic investigations. Monte Carlo modeling has been used to evaluate the potential utility of the thermochromatographic separation method, albeit this assessment is necessarily limited due to the lack of available experimental data for validation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Absolute NMR shielding scales and nuclear spin–rotation constants in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br and {sup 127}I)

We present nuclear spin–rotation constants, absolute nuclear magnetic resonance (NMR) shielding constants, and shielding spans of all the nuclei in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br, {sup 127}I), calculated using coupled-cluster singles-and-doubles with a perturbative triples (CCSD(T)) correction theory, four-component relativistic density functional theory (relativistic DFT), and non-relativistic DFT. The total nuclear spin–rotation constants determined by adding the relativistic corrections obtained from DFT calculations to the CCSD(T) values are in general in agreement with available experimental data, indicating that the computational approach followed in this study allows us to predict reliable results for the unknown spin–rotation constants in these molecules. The total NMR absolute shielding constants are determined for all the nuclei following the same approach as that applied for the nuclear spin–rotation constants. In most of the molecules, relativistic effects significantly change the computed shielding constants, demonstrating that straightforward application of the non-relativistic formula relating the electronic contribution to the nuclear spin–rotation constants and the paramagnetic contribution to the shielding constants does not yield correct results. We also analyze the origin of the unusually large absolute shielding constant and its relativistic correction of gold in AuF compared to the other gold monohalides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Gulf Nuclear Energy Infrastructure Institute: A Multidisciplinary Educational Approach for Integrated Nuclear Energy Safety Security and Safeguards in the Middle East

The Gulf Nuclear Energy Infrastructure Institute (GNEII) at Khalifa University of Science and Technology was created as a regional institute offering education, research and technical services to support nuclear energy safety, security and safeguards (3S) objectives. A mixed methods approach—using the (1) Course Evaluation, (2) GNEH Alumni Survey, (3) Capstone Project and, (4) GNEII-Related Literature data sets—was used to evaluate the effect of implementing this multidisciplinary `3S' educational program and the broader impact of the associated `3S' multidisciplinary institute on nuclear energy human resource development. Data sets (1), (2) and (3) illustrate how well GNEII implemented this novel 3S curriculum and resulted in successful knowledge transfer. Data sets (2), (3) and (4) illustrate how well GNEII's impact has positively influenced professional workplace behaviors and the institute's broader reputation to support responsible nuclear energy program education. Furthermore, GNEII demonstrates one option for successfully providing a multidisciplinary, 3S curriculum to support broader nuclear infrastructure and human resource development aims.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The MUSIC Critical Benchmark and Nuclear Data

The Measurement of Uranium Subcritical and Critical (MUSIC) experiment was a series of measurements of critical and subcritical configurations of bare highly enriched uranium. The goal was to compare measurement methods, analysis techniques, and simulation methods across regimes of criticality and to provide high-quality validation of 235 U nuclear data. A benchmark evaluation of the two critical configurations of the MUSIC experiments will soon be published in the release of the International Criticality Safety Benchmark Evaluation Project Handbook. The recent execution of the experiment aids in proper quantification of model simplifications and all uncertainties associated with the experiment. Historical benchmark evaluations are heavily relied on for uranium nuclear data validation despite the fact that the same level of documentation and comparable uncertainty analysis may not be present. The MUSIC evaluation is less likely to include “unknown unknowns” that could impede accurately modeling the system. Presented are both highly detailed and very simplified models, which represent the experimental configurations accurately, aiding the users of the benchmark for nuclear data or transport code validation. The sensitivities of k eff to nuclear data and nuclear data–related uncertainties are very similar between this experiment and previous bare uranium sphere experiments. In addition, the nuclear data uncertainties to any nuclides other than 235 U are small. For all these reasons, the recently evaluated MUSIC benchmark critical configurations could prove very useful for 235 U nuclear data validation. Currently, major libraries have good agreement with the experimental results, within 200 pcm for all nuclear data libraries, and within one standard deviation of the experimental result for most. Suggested nuclear data adjustments based on MUSIC and Lady Godiva are also presented, with posterior improvements to both the agreement in k eff and the uncertainty associated with the nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ORSphere Benchmark Evaluation and Its Potential Impact on Nuclear Criticality Safety

In the early 1970’s, critical experiments using an unreflected metal sphere of highly enriched uranium (HEU) were performed with the focus to provide a "very accurate description…as an ideal benchmark for calculational methods and cross-section data files." Two near-critical configurations of the Oak Ridge Sphere (ORSphere) were evaluated as acceptable benchmark experiments for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook). The results from those benchmark experiments were then compared with additional unmoderated and unreflected HEU metal benchmark experiment configurations currently found in the ICSBEP Handbook. For basic geometries (spheres, cylinders, and slabs) the eigenvalues calculated using MCNP5 and ENDF/B-VII.0 were within 3 of their respective benchmark values. There appears to be generally a good agreement between calculated and benchmark values for spherical and slab geometry systems. Cylindrical geometry configurations tended to calculate low, including more complex bare HEU metal systems containing cylinders. The ORSphere experiments do not calculate within their 1σ uncertainty and there is a possibility that the effect of the measured uncertainties for the GODIVA I benchmark may need reevaluated. There is significant scatter in the calculations for the highly correlated ORCEF cylinder experiments, which are constructed from close-fitting HEU discs and annuli. Selection of a nuclear data library can have a larger impact on calculated eigenvalue results than the variation found within calculations of a given experimental series, such as the ORCEF cylinders, using a single nuclear data set.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification and validation testing and tools: comparison between MCNP code versions and nuclear data libraries [Slides]

This presentation discusses the primary goal of software testing which is to test the code for correctness. It also discusses the results for individual suites and the role of validation and verification also referred to in the presentation as V&V. In summation, the V&V framework enables easy comparison between calculations performed with different code versions and/or nuclear data libraries. This entire framework will be distributed with the upcoming MCNP6.3 release. V&V test suites shown and several that were not (Criticality, LAQGSM, Lockwood) will be distributed in the new framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EchoSeed Model 6733 Iodine-125 brachytherapy source: Improved dosimetric characterization using the MCNP5 Monte Carlo code

This study primarily aimed to obtain the dosimetric characteristics of the Model 6733 {sup 125}I seed (EchoSeed) with improved precision and accuracy using a more up-to-date Monte-Carlo code and data (MCNP5) compared to previously published results, including an uncertainty analysis. Its secondary aim was to compare the results obtained using the MCNP5, MCNP4c2, and PTRAN codes for simulation of this low-energy photon-emitting source. The EchoSeed geometry and chemical compositions together with a published {sup 125}I spectrum were used to perform dosimetric characterization of this source as per the updated AAPM TG-43 protocol. These simulations were performed in liquid water material in order to obtain the clinically applicable dosimetric parameters for this source model. Dose rate constants in liquid water, derived from MCNP4c2 and MCNP5 simulations, were found to be 0.993 cGyh{sup -1} U{sup -1} ({+-}1.73%) and 0.965 cGyh{sup -1} U{sup -1} ({+-}1.68%), respectively. Overall, the MCNP5 derived radial dose and 2D anisotropy functions results were generally closer to the measured data (within {+-}4%) than MCNP4c and the published data for PTRAN code (Version 7.43), while the opposite was seen for dose rate constant. The generally improved MCNP5 Monte Carlo simulation may be attributed to a more recent and accurate cross-section library. However, some of the data points in the results obtained from the above-mentioned Monte Carlo codes showed no statistically significant differences. Derived dosimetric characteristics in liquid water are provided for clinical applications of this source model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VALIDATION OF NUCLEAR MATERIAL CONTROL AND ACCOUNTABILITY (MC&A) SYSTEM EFFECTIVENESS TOOL (MSET) AT IDAHO NATIONAL LABORATORY (INL)

A Nuclear Material Control and Accountability (MC&A) Functional Model has been developed to describe MC&A systems at facilities possessing Category I or II Special Nuclear Material (SNM). Emphasis is on achieving the objectives of 144 “Fundamental Elements” in key areas ranging from categorization of nuclear material to establishment of Material Balance Areas (MBAs), controlling access, performing quality measurements of inventories and transfers, timely reporting all activities, and detecting and investigating anomalies. An MC&A System Effectiveness Tool (MSET), including probabilistic risk assessment (PRA) technology for evaluating MC&A effectiveness and relative risk, has been developed to accompany the Functional Model. The functional model and MSET were introduced at the 48th annual International Nuclear Material Management (INMM) annual meeting in July, 20071,2. A survey/questionnaire is used to accumulate comprehensive data regarding the MC&A elements at a facility. Data is converted from the questionnaire to numerical values using the DELPHI method and exercises are conducted to evaluate the overall effectiveness of an MC&A system. In 2007 a peer review was conducted and a questionnaire was completed for a hypothetical facility and exercises were conducted. In the first quarter of 2008, a questionnaire was completed at Idaho National Laboratory (INL) and MSET exercises were conducted. The experience gained from conducting the MSET exercises at INL helped evaluate the completeness and consistency of the MC&A Functional Model, descriptions of fundamental elements of the MC&A Functional Model, relationship between the MC&A Functional Model and the MC&A PRA tool and usefulness of the MSET questionnaire data collection process.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

RISK MONITORING CAPABILITES FROM DYNAMIC PRA DATA

Risk Monitors (RMs) are software tools that are employed in nuclear power plants to monitor the safety properties of the plant itself during operation. These safety properties are generated using classical PRA methods which are typically based on static Boolean structures such as Fault-Trees (FTs) and Event-Trees (ETs). The outcomes of these methods are Core Damage Frequency (CDF) and risk importance values of plant components (e.g., valves and pumps). Examples of Risk Importance Measures (RIMs) commonly used are: Risk Achievement Worth (RAW), Risk Reduction Worth (RRW), Birnbaum (B) and Fussell-Vesely (FV) [1,2]. In a RM these values are updated in real time once plant components status is updated (e.g., under maintenance, off-line, testing). In addition, RMs can be used to optimize maintenance schedules so those safety features of the plant are below plant standard values. This paper presents an approach to create temporal profiles of RIMs (i.e., RM capabilities) given a temporal change of the plant configuration. Instead of employing data generated by ETs and FTs, the proposed approach will employ data generated by Dynamic PRA methods. In contrast to classical PRA methods, Dynamic PRA methods couple stochastic methods with safety analysis codes to determine risk associate to complex systems such as nuclear plants. Compared to classical PRA methods, they can evaluate with higher resolution the safety impact of timing and sequencing of events on the accident progression. We will describe how classical RIMs can be generated by Dynamic PRA data and then we will show how the temporal profiles of the RIMs can be generated given a temporal profile of the system configuration.

97 MATHEMATICS AND COMPUTING↗

Testing of ENDF71x: A new ACE-formatted neutron data library based on ENDF/B-VII.1

The ENDF71x library [1] is the most thoroughly tested set of ACE-format data tables ever released by the Nuclear Data Team at Los Alamos National Laboratory (LANL). It is based on ENDF/B-VII. 1, the most recently released set of evaluated nuclear data files produced by the US Cross Section Evaluation Working Group (CSEWG). A variety of techniques were used to test and verify the ENDF7 1x library before its public release. These include the use of automated checking codes written by members of the Nuclear Data Team, visual inspections of key neutron data, MCNP6 calculations designed to test data for every included combination of isotope and temperature as comprehensively as possible, and direct comparisons between ENDF71x and previous ACE library releases. Visual inspection of some of the most important neutron data revealed energy balance problems and unphysical discontinuities in the cross sections for some nuclides. Doppler broadening of the total cross sections with increasing temperature was found to be qualitatively correct. Test calculations performed using MCNP prompted two modifications to the MCNP6 source code and also exposed bad secondary neutron yields for {sup 231,233}Pa that are present in both ENDF/B-VII.1 and ENDF/B-VII.0. A comparison of ENDF71x with its predecessor ACE library, ENDF70, showed that dramatic changes have been made in the neutron cross section data for a number of isotopes between ENDF/B-VII.0 and ENDF/B-VII.1. Based on the results of these verification tests and the validation tests performed by Kahler, et al. [2], the ENDF71x library is recommended for use in all Monte Carlo applications. (authors)

97 MATHEMATICS AND COMPUTING↗

On the Methodology to Calculate the Covariance of Estimated Resonance Parameters

Principles to determine resonance parameters and their covariance from experimental data are discussed. Different methods to propagate the covariance of experimental parameters are compared. A full Bayesian statistical analysis reveals that the level to which the initial uncertainty of the experimental parameters propagates, strongly depends on the experimental conditions. For high precision data the initial uncertainties of experimental parameters, like a normalization factor, has almost no impact on the covariance of the parameters in case of thick sample measurements and conventional uncertainty propagation or full Bayesian analysis. The covariances derived from a full Bayesian analysis and least-squares fit are derived under the condition that the model describing the experimental observables is perfect. When the quality of the model can not be verified a more conservative method based on a renormalization of the covariance matrix is recommended to propagate fully the uncertainty of experimental systematic effects. Finally, neutron resonance transmission analysis is proposed as an accurate method to validate evaluated data libraries in the resolved resonance region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 28 Si ⁢(𝑛,𝑛′⁢𝛾) cross section with 𝑛, 𝛾, and correlated 𝑛−𝛾 angular distributions

Silicon has become an unavoidable element in the circuitry central to everyday life. In turn, the interactions of silicon isotopes with neutrons for nuclear physics applications, among other motivations, have become increasingly important to understand. The dominant isotope of silicon, 28 Si, is thus of primary interest for enhanced understanding for neutron transport calculations and related investigations. Unfortunately, the existing measurement database for neutron scattering reactions on 28 Si is minimal, and nuclear data evaluations on this topic have not been updated for decades. This article details new measurements of the 28 Si ⁢(𝑛,𝑛′⁢𝛾) reaction utilizing multiple analysis methods available within the correlated gamma neutron array for scattering (CoGNAC). Specifically, high-precision near-threshold results and high-incident-energy results were obtained using the 𝛾-only and correlated 𝑛−𝛾 techniques. First-ever measurements of the correlated 𝑛−𝛾 angular distribution for particles emitted following population of the first excited state in 28 Si were obtained as well, which provide unique insight into theoretical descriptions of the inelastic neutron scattering reaction mechanism itself and detailed guidance for nuclear reaction models. The results agree well with literature data where they exist, and substantially expand on the current database for neutron reactions on 28 Si .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Polarization Sensitivity of the DAGATA Polarimeter

In comparison to common Compton Polarimeters the DAGATA (Darmstadt GAmma-ray Tracking Assembly) polarimeter will significantly enhance the sensitivity for gamma-rays above 4 MeV making use of its large volume 36-fold segmented HPGe AGATA crystal and the resulting superior position resolution. Results from Monte Carlo Simulations will be presented as well as approaches for data analysis to further improve the sensitivity. Application limits and realistic simulated spectra will be compared to results from existing polarimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗