Search NASA⌕ Search

SEARCH · Search NASA

Results for “Office Equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Advanced Test Reactor Long-Term (20-Year) Operational Strategy

The Department of Energy Office of Nuclear Energy (DOE-NE) and the Naval Nuclear Propulsion Program (NNPP) have identified the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) as a critical need for continued thermal irradiation testing capability to support and advance U.S. commercial and naval nuclear power systems. The ATR is currently the only suitable test reactor operating in the world that can provide these capabilities at volume. ATR must, then, plan to operate for at least the next 20 years. As of the beginning of 2024, ATR has operated for 57 years, with many of the original reactor structures, systems, and components installed and operated for 60 years. Some ATR Complex and reactor support equipment that is currently in use was installed 75 years ago with the startup of the Materials Testing Reactor (MTR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation-Hardened Instrumentation, Sensors and Electronics

To assist the US Department of Energy in defining a course for Office of Nuclear Energy–funded radiation-hardened (rad-hard) electronics research, Oak Ridge National Laboratory (ORNL) will focus on three main tasks in FY21. The first task will investigate the survivability of silicon junction-gate field-effect transistors (Si-JFETs) through a 100 Mrad total ionizing dose (TID) experiment and report the test results. The second task will investigate wide bandgap (WBG)-based JFET devices and sources. The third task is an investigation into commercially available systems and components and will be performed to determine whether a standardized list of devices can be identified for reactor instrumentation application. If the devices are feasible, then this list will provide direction to designers and equipment suppliers for selection of components to meet specific reactor requirements.

42 ENGINEERING↗

Secure Storage: Historical Documentation of TA-08-0032, TA-11-0036, TA-22-0016, TA-22-0023, TA-22-0025, TA-22-0035, TA-37-0006, TA-37-0009, and TA-37-0020

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (NA-LA), is pursuing the decommissioning and demolition (D&D) of facilities contaminated with high-explosives residues at the Los Alamos National Laboratory (Laboratory or LANL). This effort affects nine facilities associated with high-explosives and detonator research, development, and storage: Technical Area (TA) 8 Facility 32 (TA-08-0032), TA-11-0036, TA-22-0016, TA-22-0023, TA-22-0025, TA-22-0035, TA-37-0006, TA-37-0009, and TA-37-0020. All nine facilities proposed for D&D have been evaluated for listing in the National Register of Historic Places (NRHP) and determined eligible. NA-LA previously requested the State Historic Preservation Officer (SHPO) to concur with the NRHP-eligibility determinations of these nine properties presented in four reports: (1) TA-08-0032 was determined eligible for listing in the NRHP in the report, From Ranching to Radiography: An Assessment of Historic Buildings at Anchor West Site (TA-8), Vol. 1 (McGehee et al. 2008a). The SHPO concurred with this eligibility determination on November 26, 2008. (2) TA-11-0036 was determined eligible for listing in the NRHP in the report, ESA Division’s Five-Year Plan: Consolidation and Revitalization at Technical Areas 3, 8, 11, and 16, Vol. 1) (McGehee et al. 2003). The SHPO concurred with this eligibility assessment on June 22, 2003. (3) TA-22-0016, TA-22-0023, TA-22-0025, and TA-22-0035 were determined eligible for listing in the NRHP in the report, DX Division’s Facility Strategic Plan: Consolidation and Revitalization at Technical Areas 6, 8, 9, 14, 15, 22, 36, 39, 40, 60, and 69, Vol. 1 (McGehee et al. 2005a). The SHPO concurred with these eligibility determinations on April 18, 2006. (4) TA-37-0006, TA-37-0009, and TA-37-0020 were determined eligible for listing in the NRHP in the report, High Explosives and the Nuclear Stockpile: An Assessment of Historic Buildings at Magazine Area C (TA-37), Vol. 1 (McGehee et al. 2008b). The SHPO concurred with these eligibility determinations on April 17, 2008. In a letter dated January 24, 2020, NA-LA acknowledged that the D&D of these nine NRHP-eligible facilities was an adverse effect that requires resolution through mitigation. NA-LA proposed the use of standard mitigation practices as defined in the Programmatic Agreement (PA) among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office, and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos, New Mexico. The PA states that adverse effects to NRHP-eligible buildings and structures will be resolved according to the standard practices defined in Part II, Section 10, of the Laboratory’s Cultural Resources Management Plan, A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (Purtzer et al. 2019), and Section 2.B of Appendix D of the PA itself. The standard practice documentation package includes the following components: (1) Interior and exterior photography and production of archival-quality digital photographs; (2) Documentation and curation of historically significant equipment and artifacts; (3) A list of all known drawings for the property; (4) Reduced-scale reproductions of selected drawings for the property; (5) A location map that shows the location of the property relative to the entire Laboratory property; (6) Reproduction of historical TA maps; (7) A TA map that depicts the footprint of each eligible and non-eligible facility; and (8) An expanded historic context that uses oral-history interviews, if available. On March 3, 2020, the SHPO concurred with the adverse effect determination and the mitigation plan. The documentation package, as previously described, is provided in Volumes 1 and 2 of this report.

99 GENERAL AND MISCELLANEOUS↗

Office of Nuclear Verification FY 2023 Quarterly Report TSVT Q1

This project encompasses the continued development and training of a U.S. operational team, the Test Site Verification Team (TSVT), supporting verification of nuclear testing activities. TSVT builds on decades of U.S. nuclear testing history and nuclear explosion monitoring experience. The Team maintains readiness to deploy internationally on short notice to provide field-based support of verification of declared or undeclared nuclear testing and associated activities, as well as follow-on activities including monitoring and capability disablement and dismantlement, as established by negotiated agreement or treaty. The roles and structure of the TSVT are integrated with other NA-243 deployable verification teams and the interagency. FY23 TSVT activities focus on continued capability buildup within the team, including Team trainings and exercises with a focus on missions in confined spaces (e.g., tunnels, mines, other underground facilities), increased familiarity with foreign nuclear weapons testing programs, demonstration of Team capacity to deploy, train, and practice sustained OPSEC in non-western locations, establishment of sustainable storage and maintenance of equipment, specification and procurement of additional equipment to support field observations, further evolution of concepts of operation documents (CONOPs), and mission coordination with Headquarters and associated Stakeholders. Activities will culminate with a full-scale domestic team exercise at the end of FY23 focusing on underground activities signatures/observations and safety including advanced outdoor safety and familiarity in working around explosive test environments. In addition, we will be further articulating approaches and capacity relevant to the identification of nuclear tests, as well as monitoring of nuclear testing activities and/or dismantlement of nuclear test sites and anticipate developing additional equipment requests in support of this evolution. The TSVT Team Leads will also coordinate with its Senior Advisor, the TSVT Logistics and Readiness (L&R) Training Lead, and NNSA Headquarters to draft a five-year TSVT training and exercise plan, that strategically and incrementally builds capacity and expertise in key areas of significance for the continuum of nuclear and nuclear-related testing activities that fall within the team’s mission space.

42 ENGINEERING↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Airport Ground Support Equipment Infrastructure & Logistics Electrification Assessment Tool: 2025 Data Development, Modeling and Analysis for DFW

The aviation industry is increasingly turning to modernize freight facilities by integrating electric Ground Support Equipment (eGSE) to enhance operational efficiency of freight facility moving vehicles and equipment. Airports worldwide are adopting eGSE to streamline cargo movement, reduce fuel and maintenance costs, and improve logistics coordination.1 North America, with its advanced aviation infrastructure, leads this transition, leveraging Internet of things (IoT)-enabled automation and zero emission technologies to boost reliability and reduce human errors.2 Electrification of freight facility moving vehicles and equipment boosts turnaround times, improves equipment reliability, and optimizes logistics coordination, giving operators a competitive advantage. With rising fuel price volatility and the pressure to meet stringent performance benchmarks, airports are focusing on cost-effective, scalable solutions for long-term financial and operational gains. To further accelerate electrification, airports are integrating Zero Emission Vehicles (ZEVs) into rental car fleets and deploying electric baggage carts, requiring strategic investments in charging infrastructure. 3 The shift, however, presents challenges, such as limited technical expertise, high capital costs, and complex procurement processes. By forging strategic partnerships, leveraging advanced technologies, and optimizing infrastructure investments, airports can create a resilient, future-ready ecosystem that enhances the movement of people and goods through electrification-driven efficiency. Supported by the U.S. Department of Energy (DOE) Vehicle Technologies Office (VTO), this electrification effort provides a scalable, cost-effective solution to improve airport freight operations. Through targeted investments and innovation, airports enhance efficiency, reduce costs, and meet performance benchmarks while advancing toward a resilient, electrified future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure

With the support of DOE's Vehicle Technologies Office and the DOE/DOT Joint Office (JO), NREL has applied the EVI-X modeling suite to conduct a National Electric Vehicle Infrastructure Needs Assessment. This report considers a 2030 scenario in which 50% of light-duty sales are electric (including plug-in hybrids), resulting in an on-road stock of 33 million vehicles. We consider the needs of vehicles used for typical daily driving, drivers without access to residential charging, corridor charging supporting long-distance travel, and ride-hailing electrification. We find that a cumulative capital investment of $82 billion in public and private charging infrastructure will be necessary in our baseline scenario (approximately 3x greater than our estimate of planned investments to date). This result is framed as a conservative estimate as the assumed costs include charging equipment and installation but exclude the cost of grid upgrades and distributed energy resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling U.S. Light-Duty Demand for EV Charging Infrastructure in 2030

With the support of DOE's Vehicle Technologies Office and the DOE/DOT Joint Office (JO), NREL has applied the EVI-X modeling suite to conduct a National Electric Vehicle Infrastructure Needs Assessment. This report considers a 2030 scenario in which 50% of light-duty sales are electric (including plug-in hybrids), resulting in an on-road stock of 33 million vehicles. We consider the needs of vehicles used for typical daily driving, drivers without access to residential charging, corridor charging supporting long-distance travel, and ride-hailing electrification. We find that a cumulative capital investment of $82 billion in public and private charging infrastructure will be necessary in our baseline scenario (approximately 3x greater than our estimate of planned investments to date). This result is framed as a conservative estimate as the assumed costs include charging equipment and installation but exclude the cost of grid upgrades and distributed energy resources.

33 ADVANCED PROPULSION SYSTEMS↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Characterization of MC&A for the Molten Salt Fuel Cycle

Advanced reactor developers are exploring diverse reactor designs, including molten salt reactors (MSRs). These advanced reactors are considered for wider applications and a range of deployment locations, including supporting the integration of renewable energy sources in the grid. There are three main types of MSRs: (1) reactors in which the fuel salt freely circulates within the core; (2) reactors with the fuel salt contained within vented fuel tubes; and (3) reactors that use molten salt solely as a coolant, with the fuel in a separate, solid form. In this document, the term MSR refers specifically to the first two types, which use fuel salt—special nuclear material (enriched uranium, plutonium, and 233 U) in chloride or fluoride form mixed with chloride- or fluoride-based carrier salt in a peritectic mixture—as the primary medium for fission. The composition of fuel salt, both at startup and for makeup or refueling, varies depending on the MSR design and the chosen fuel cycle approach, which can be either once-through or closed. For MSRs, a variety of fuel cycle approaches (e.g., U, U–Pu, U–Pu–TRU, U–Th, U–Pu–Th) are being considered. Fuel in MSRs is much different than traditional solid fuel, including its preparation. The uniqueness warrants investigation into characterizing fuel preparation processes, known as fuel salt synthesis . This effort characterized major fuel preparation and synthesis processes, identifying temperature, equipment, and environmental requirements for uranium-, plutonium-, and thorium-based fuel preparation and synthesis. Because MSR fuel salt synthesis facilities handle special nuclear material in loose, bulk form, a material control and accounting plan will be required for licensing from the US Nuclear Regulatory Commission or under the US Department of Energy authorization. This effort serves as a foundation to investigate material control and accounting approaches for synthesis facilities, including determining measurement points and techniques. Because several MSR developers are planning demonstration facilities in the coming years, this effort will support stakeholders with preparing or reviewing material control and accounting plans for providing assurance that all special nuclear material is accounted for at fuel salt synthesis facilities. This report was produced for Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy (DOE), Office of Nuclear Energy, Nuclear Fuel Cycle and Supply Chain.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Fuel Fabrication Report

The U.S. Department of Energy Office of Nuclear Energy (DOE NE) and the Idaho National Laboratory (INL) Advanced Reactor Technologies (ART) Advanced Gas Reactor (AGR) Fuel Development and Qualification program (referred to as AGR Fuel program hereafter) are pursuing qualification of tristructural isotropic (TRISO) coated particle fuel for use in high temperature gas cooled reactors (HTGRs). The AGR Fuel program was established to provide a fuel qualification data set in support of the licensing and operation of an HTGR. BWX Technologies Nuclear Operations Group (BWXT-NOG) was subcontracted to fabricate the fuel for the AGR program. Several investments and innovations were realized in preparation to fabricate fuel for the AGR-5/6/7 irradiation experiments that brought fuel fabrication fully out of the laboratory and into engineering-scale operations. These included: • Increased the kernel fabrication line capacity and uniformity • Upgraded ancillary support equipment and processes for the tristructural isotropic (TRISO) coating furnace • Demonstrated efficient production of the matrix precursor powder by dry jet milling of co mingled components • Demonstrated an engineering-scale method for quick and efficient overcoating TRISO particles with the matrix precursor • Demonstrated an automated, multi cavity compacting system with a volumetric feed system • Demonstrated a combined-cycle thermal treatment furnace These changes increased production rates of some of these processes by an order of magnitude or more while eliminating the use of flammable solvents, multiple grinding and sorting operations, and the weighing out of individual die charges. Three fuel kernel lots were fabricated for production of the fuel for AGR-5/6/7. The initial lot (J52R-16-39316) was certified to fuel specifications but was not used because the kernels had a high fraction of internal fissures that caused an unacceptable fraction of the kernels to fragment when charged to the coating furnace where the TRISO coating would be deposited. Fragmented kernels increased the dispersed uranium in the particles and produced a worrisome fraction of dimpled particles with an elevated probability of in-pile failure. After some efforts to identify the cause of the fissure formation, two additional lots were produced with much lower fissure fractions, J52R-16-69317 and 69318. The latter kernel lot was a backup to the first and was not needed. Multiple kernel batches were composited to form each of the lots so as to simulate a commercial-scale operation where kernel batches would also be composited. Multiple TRISO coating runs were performed and the product characterized so that several could be composited into a TRISO lot. TRISO lot J52R-16-98005 conformed to all fuel specifications except the mean outer pyrocarbon (OPyC) layer thickness was thinner than specified. Furthermore, it was determined that the TRISO lot had a dispersed uranium fraction (DUF) that might result in the compacts not meeting the DUF specification. A review of the role of the OPyC layer and consequences of the DUF by the Technical Coordination Team and INL concluded that the fuel was acceptable for use in the AGR-5/6/7 irradiation experiment. The TRISO particles were overcoated with the matrix precursor that had been produced in a jet-milling operation. The overcoating was performed in equipment originally designed to coat pharmaceuticals. The overcoating process performed well; producing highly spherical and uniform overcoats requiring little upgrading and no recycle or rework. TRISO particles were overcoated with the matrix precursor to achieve nominal volumetric packing fractions (PFs) of TRISO particles of 25% and 40% for the irradiation experiments. The 40% PF compacts occupy the first and fifth test capsule in the test train while the inner three capsules are loaded with 25% PF compacts. The resinated graphite matrix precursor powder was a derivative of the German A3-27 matrix formulation, which differs from previous AGR irradiation campaigns that used an A3-3 formulation. Jet milling of the matrix powder precursor produced a finer mean graphite particle size than the milling operations used for the A3-3 matrix powder precursor. Changes made in the matrix formula and equipment yielded compacts with significantly higher matrix density than was attained in previous AGR irradiation campaigns. The changes in the matrix formulation and the means of milling the powders also complicated resolution of the three fuel compact defect fractions, DUF, exposed kernel fraction (EKF), and the silicon carbide defect fraction (SDF). Characterization data from BWXT-NOG had some anomalous results, so samples of the fuel compacts and overcoated TRISO particles were also analyzed by Oak Ridge National Laboratory (ORNL) to ensure that the defect fractions were accurately characterized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

US Department of Energy, Office of Science High Performance Computing Facility Operational Assessment 2021: Oak Ridge Leadership Computing Facility

Oak Ridge National Laboratory’s (ORNL’s) Leadership Computing Facility (OLCF) continues to surpass its operational target goals of supporting users; delivering fast, reliable computational ecosystems; creating innovative solutions for high-performance computing (HPC) needs; contributing to the community to build the next generation HPC workforce, and managing risks, safety, and security associated with operating some of the most powerful computers in the world. The results can be seen in the cutting-edge science conducted by users and the praise from the research community. Calendar year (CY) 2021 saw continued excellence in research supported by the OLCF’s leadership-class computing resources, including Summit (the nation’s most powerful supercomputer), the global scratch file system Alpine, the Scalable Protected Infrastructure (SPI), the Exploratory Visualization Environment for Research in Science and Technology (EVEREST), and the archival mass-storage resource High-Performance Storage System (HPSS). While maintaining access and exceptional user support for Summit, the OLCF continued to make progress on the installation and deployment of Frontier, which will be the nation’s first exascale system when it comes online at the start of CY 2023. Users have already begun running and optimizing scientific codes on Crusher, the OLCF test and development system equipped with Frontier’s architecture. Throughout the year, the OLCF maintained a strong culture of operational excellence, including risk management, workplace safety, and cybersecurity. The OLCF’s rigorous risk management strategy anticipated and mitigated risks, and at this time there are no high-priority operational risks. Similarly, ORNL and the OLCF were committed to operating under the US Department of Energy’s (DOE’s) safety regulations that ensure a safe workplace. Technical staff tracked and monitored existing threats and vulnerabilities within the OLCF while continually developing tools and practices to enhance operations without increasing the facility’s risk. CY 2021 was filled with outstanding results and accomplishments, including a very high rating from users on overall satisfaction for the eighth consecutive year; a tremendous number of node hours delivered to 1,671 researchers on Summit; and the successful delivery of the allocation split of roughly 60%, 20%, and 20% of core-hours offered for the Innovative and Novel Computational Impact on Theory and Experiment (INCITE), Advanced Scientific Computing Research Leadership Computing Challenge (ALCC), and Director’s Discretionary (DD) programs, respectively (Section 2). COVID-19 research remained a focus in 2021, and the ALCC and DD programs allocated over 1 million Summit hours to the COVID-19 High Performance Computing Consortium. These accomplishments, coupled with the high utilization rates (i.e., overall and capability usage), represent the fulfillment of the promise of leadership class machines: efficient facilitation of leadership-class computational applications.

97 MATHEMATICS AND COMPUTING↗

Section 110 Documentation of a Douglas AD-2 Skyraider Crash Site, Area 1, Nevada National Security Site, Nye County, Nevada

The National Nuclear Security Administration, Nevada Field Office has undertaken a Section 110 current condition assessment of the unanticipated discovery of an aviation crash site in Nye County, Nevada. Because no undertaking is planned, an area of potential effect (APE) was not defined. A study area of 0.55 acres was established to delineate the general extent of the debris scatter and establish a boundary for the cultural resource documentation of the site by Desert Research Institute (DRI). The Douglas AD-2 Skyraider drone crash site (26NY17011) is recommended eligible for the National Register of Historic Places (NRHP) under Significance Criterion A, as a physical remnant of Project 5.1 “Atomic Weapons Effects on AD Type Aircraft in Flight,” one of the series of military effects studies conducted as part of Shot Simon during Operation Upshot-Knothole in 1953. Furthermore, the site is eligible under Criterion D because closer examination of the debris could address research questions concerning the Type 1 Remote Control Equipment developed by the Naval Air Experimental Station that was onboard to remotely pilot the aircraft.

54 ENVIRONMENTAL SCIENCES↗

Vanderbilt Alumni Hall

This dataset includes processed and raw data from the Vanderbilt Alumni Hall Building (VAH) located on the University of Vanderbilt Campus in Nashville, TN. VAH is a mixed use commercial building (LEED Gold Certified) that consists of classrooms, meeting rooms, office rooms, conference rooms, an exercise room, and others. This dataset spans one year of time-series data from 2019 and includes measurements corresponding to whole building electrical power, thermal power, zone level thermal power, set-point, indoor temperature, humidity, water and air side supply and return temperatures and flow rates as CSV files. In addition to the measurements, a metadata .json file, and a .ttl file to visualize the data as per BRICK schema are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CIE Curriculum Guide (V.2.0)

The Cyber-Informed Engineering (CIE) Curriculum Guide offers a comprehensive framework, guidance, and resources for integrating CIE into university-level engineering programs and related educational activities. The primary goal is to help educators adopt CIE principles into their teaching to produce future engineers and technicians who understand digital risks in modern engineered systems, thereby addressing the nation’s infrastructure resilience needs. This guide outlines practical integration examples, links to resources to accelerate CIE adoption, and shares insights from partner academic institutions on various implementation strategies. CIE is a framework for embedding engineered controls that mitigate the impact of cyber-attacks in any cyber-physical system used in critical energy infrastructure and other sectors. Developed by the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER), the National Cyber-Informed Engineering Strategy emphasizes embedding CIE into formal education, training, and credentialing. This guide supports this strategic objective by providing examples of integrating CIE concepts into engineering curricula, from class activities to new courses and certificate programs. The importance of educating cyber-informed engineers is underscored by the evolving cybersecurity threats facing engineered systems. As industrial control systems (ICS) increasingly incorporate digital technologies, the responsibility for security extends to both cyber professionals and engineers. CIE addresses critical gaps in designing and protecting physical systems with digital components against cyber risks, ensuring engineers consider digital risk throughout the engineering design lifecycle. Currently, engineering education does not routinely include cyber-informed principles, highlighting a gap in addressing modern engineering system risks. This guide advocates for updating engineering curricula to include digital risk management as a fundamental element. By doing so, future engineers will be equipped to design resilient systems that mitigate digital risks from the outset. Through this guide, engineering faculty can integrate CIE into their curricula, bridging the gap between digital risk and engineering. This approach prepares a cyber-informed workforce capable of safeguarding the cyber-physical systems crucial to national security and public welfare. By embedding CIE into education and training, institutions can produce engineers and technicians who can effectively mitigate cyber impacts throughout the engineering design lifecycle, resulting in more secure critical infrastructures.

42 - ENGINEERING↗

High-Efficiency, Medium-Voltage-Input, Solid-State-Transformer-Based 400-kW/1000V/400A Extreme Fast Charger for Electric Vehicles

Range anxiety and long battery charging time continue to be critical challenges to mass adaptation of EVs. A major identified gap to wider adoption of BEVs is the ability and availability to refuel quickly or to fast charge. Studies have shown that in areas where drivers have access to 50-kW or 120-kW fast charge stations, annual electric vehicle (EV) miles traveled (i.e., eVMT) increased by over 25%, even in cases where fast charging was used for 1% to 5% of total charging events. Charge stations of higher power not only alleviate the “range anxiety” and reduce the driver’s waiting time, but also requires less investment. Michigan Energy Office completed a study in early 2019 titled “Electric Vehicle Charger Placement Optimization in Michigan: Phase I – Highways”. This study finds a system with 150kW chargers, though more expensive individually, actually has lower total system cost when compared to a 50kW charging system when serving the same battery size EV. To be truly competitive to the ICEV refueling experience, even higher power stations are necessary. However, high power charge stations would create large power draws from the grid. If this occurs during peak demand periods, grid capacity could be overloaded. This problem needs to be addressed to reduce the impact on the electric utility infrastructure. The main goal of this project is to develop a 400-kW/400-A XFC system targeting total efficiency of 96.5 percent from the MVAC grid to a vehicle. The novel SST power cell topology, combined with a new silicon carbide (SiC) MOSFET device, enables a 3.5 percent improvement in system efficiency, a 50-percent smaller equipment footprint, and four times less weight than today’s DCFC systems. The SST technology would directly utilize MVAC at 4.8-kV or 13.2-kV. This would eliminate the line frequency transformer (LFT), which steps down medium-voltage AC to 3-Phase 480-V line-to-line voltage in current DCFC systems.

42 ENGINEERING↗

Acoustic Travel-Time Tomography for Wind Energy

New remote sensing technologies for direct observation of the atmospheric flow in the proximity of operating wind turbines are necessary for the advancement of wind turbine design, wind plant control, and the validation of high-fidelity numerical models; fundamental goals of the DOE Wind Energy Technology Office's (WETO's) A2e program. Modern remote sensing technologies for commercial and research applications rely on the backscatter of light or sound waves, which limits spatial and temporal resolution and cannot produce reliable flow estimates near solid bodies or reflective surfaces. Acoustic tomography (AT) is an innovative sensing technology based on fundamental thermodynamic properties of the atmosphere and an inverse algorithm that can reconstruct both velocity and temperature fields within a network of acoustic transducers. AT relies on the direct travel path of acoustic signals between speakers and microphones in the network and can achieve much higher resolutions than conventional backscatter technologies. For wind energy R&D applications, AT represents an extremely economical option over other remote sensing technologies, integrating mature and commonly available acoustic and signal processing hardware. This report is intended as an update on the development of the AT array on the NREL Flatirons Campus (FC) and includes a brief review of the instrumentation, the calibration of equipment, signal processing, and resulting flow field estimates. Designs for future AT systems and applications are detailed in this report, including summaries of new capabilities, engineering and theoretical challenges, and anticipated costs help to outline future directions for AT technology R\&D. The potential for application of AT to utility-scale turbines is also discussed. Investing in the development of the proposed instrument will establish AT as a transformational RS technique that represents a significant advance in measurement instrumentation, enabling new fundamental insights into the structure of the atmospheric boundary layer and supporting applications for wind energy, pollution transport, and resource characterization. AT is also an extremely economical option over other RS instruments, integrating mature and commonly available acoustic and signal processing hardware.

17 WIND ENERGY↗