Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Nonlinear optics with two trapped atoms

We show theoretically that two atomic dipoles in a resonator constitute a nonlinear medium, whose properties can be controlled through the relative position of the atoms inside the cavity and the detuning and intensity of the driving laser. We identify the parameter regime where the system operates as a parametric amplifier, based on the cascade emission of the collective dipole of the atoms, and determine the corresponding spectrum of squeezing of the field at the cavity output. This dynamics might be observed as a result of self-organization of laser-cooled atoms in resonators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent-state phase concentration by quantum probabilistic amplification

We propose a probabilistic measurement-induced amplification for coherent states. The amplification scheme uses a counterintuitive architecture: a thermal noise addition (instead of a single-photon addition) followed by a feasible multiple-photon subtraction using a realistic photon-number-resolving detector. It allows one to substantially amplify weak coherent states and simultaneously reduce their phase uncertainty, which is impossible when using a deterministic Gaussian amplifier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical amplifier-powered quantum optical amplification

I show that an optical amplifier, when combined with photon subtraction, can be used for quantum state amplification, adding noise at a level below the standard minimum. The device could be used to significantly decrease the probability of incorrectly identifying coherent states chosen from a finite set.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum light by atomic arrays in optical resonators

Light scattering by a periodic atomic array is studied when the atoms couple with the mode of a high-finesse optical resonator and are driven by a laser. When the von-Laue condition is not satisfied, there is no coherent emission into the cavity mode, and the latter is pumped via inelastic scattering processes. We consider this situation and identify conditions for which different nonlinear optical processes can occur. We show that these processes can be controlled by suitably tuning the strength of laser and cavity coupling, the angle between laser and cavity axis, and the array periodicity. We characterize the coherence properties of the light when the system can either operate as degenerate parametric amplifier or as a source of antibunched light. Our study permits us to identify the individual multiphoton components of the nonlinear optical response of the atomic array and the corresponding parameter regimes, thereby in principle allowing one to control the nonlinear optical response of the medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Passive-State Preparation for Continuous-Variable Quantum Communications

In the Gaussian-modulated coherent state quantum key distribution (QKD) protocol, the sender first generates Gaussian-distributed random numbers and then encodes them on weak laser pulses actively by performing amplitude and phase modulations. Recently, an equivalent passive QKD scheme has been proposed by exploring the intrinsic field fluctuations of a thermal source [B. Qi, P. G. Evans, and W. P. Grice, Phys. Rev. A 97, 012317 (2018)]. This passive QKD scheme is especially appealing for chip-scale implementation since no active modulation is required. In this paper, we conduct an experimental study of the passively encoded QKD scheme using an off-the-shelf amplified spontaneous emission source operated in continuous-wave mode. Our results show that the excess noise introduced by the passive state preparation scheme can be effectively suppressed by applying optical attenuation and a secure key can be generated over metro-area distances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanisms for suppressing the transverse mode coupling instability in a circular accelerator

The chromatic and nonlinear suppression of the transverse mode coupling instability in a circular accelerator is analyzed. Analytical estimates are compared with the results of experiments and numerical simulations. The transverse mode coupling (or fast head-tail) instability is a significant factor that limits the beam intensity in circular accelerators. This instability arises when the bunch current exceeds a threshold value determined by the broadband impedance of the vacuum chamber. Feedback systems are traditionally used to suppress the instability. The experience of working with such systems shows that their efficiency depends strongly on the operating parameters of the amplifier, particularly on the chromaticity and nonlinearity of the magnetic lattice. Thus, both chromatic and nonlinear effects should be taken into account to better understand the physical processes and to increase the feedback efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mass Spectrometer Transient Analysis

This software implements a complete preprocessing pipeline for transient mass spectrometry (MS) data collected during TAP (Temporal Analysis of Products) experiments. It is designed to extract chemically meaningful fluxes from overlapping ion signals by applying a calibrated defragmentation matrix and solving the resulting linear system using non-negative least squares (NNLS) regression. The core script, preprocess_mass_spec.py, performs the following operations: Gain correction: Applies amplifier gain scalars derived from inert-packed calibration pulses to normalize signal intensities across AMUs and acquisition settings. Background subtraction: Removes experiment baselines using user-defined time windows, ensuring compatibility with slow-diffusing species and preventing negative values that would interfere with NNLS. Options to subtract before and after defragmentation. Defragmentation: Constructs a fragmentation matrix A from zeroth moments of calibration pulses (equal molar gas:inert mixtures) and solves Ax=b at each time point, where b is the raw MS signal and x is the estimated species flux. The matrix is normalized to inert signals and accounts for instrument-specific fragmentation behavior. Pulse-mode handling: Supports both averaged and individual pulse modes, enabling statistical treatment of fluxes and calculation of standard deviations. Integration and output: Computes zeroth moments (integrated fluxes) and exports time-resolved and integrated data in CSV format, suitable for downstream kinetic modeling. The software is validated using both virtual TAP simulations (VTAP) and experimental data from propane dehydrogenation (PDH) on CrOx/Al2O3 catalysts. It preserves temporal resolution by applying NNLS point-by-point across the pulse duration (typically 6,000+ time slices per pulse), leveraging the linear superposition principle to reconstruct full flux profiles. The defragmented outputs are compatible with kinetic extraction methods such as the G and Y procedures, which are used to derive rate–concentration relationships from TAP data. The details of these validations are discussed in detail in the supporting manuscript and supporting information. Example data and output files are also included. The methodology is robust to experimental noise and drift, with calibration protocols that account for pulse size effects, MS aging, and inert gas normalization. The software is modular, reproducible, and tailored for high-throughput TAP-MS workflows in catalysis research.

Kristy, Stephen [Idaho National Laboratory (INL), ↗

Characterization and Comparison of Control Units for Piezo Actuators to be used for Lorentz Force Compensation inth ILC

Superconducting accelerators, such as the International Linear Collider (ILC), rely on very high Q accelerating cavities to achieve high electric fields at low RF power. Such cavities have very narrow resonances: a few kHz with a 1.3GHz resonance frequency for the ILC. Several mechanical factors cause tune shifts much larger than this: pressure variations in the liquid helium bath; microphonics from pumps and other mechanical devices; and for a pulsed machine such as the ILC, Lorentz force detuning (pressure from the contained RF field). Simple passive stiffening is limited by many manufacturing and material considerations. Therefore, active tuning using piezo actuators is needed. Here we study a supply for their operation. Since commercial power amplifiers are expensive, we analyzed the characteristics of four power amplifiers: (iPZD) built by Istituto Nazionale di Fisica Nucleare (Sezione di Pisa); and a DC-DC converter power supply built in Fermilab (Piezo Master); and two commercial amplifiers, Piezosystem jena and Piezomechanik. This paper presents an analysis and characterization of these amplifiers to understand the cost benefit and reliability when using in a large scale, pulsed beam accelerator like the ILC.

43 PARTICLE ACCELERATORS↗

Analysis of a Novel Diffractive Scanning Wire Beam Position Monitor (BPM) for Discriminative Profiling of Electron Vs. X Ray Beams

Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPM with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r&d) tasks for fabricating and testing the proposed BPM are discussed.

43 PARTICLE ACCELERATORS↗

Feedback Requirements for SASE-FELs

The operation of a Self Amplified Spontaneous Emission (SASE) Free Electron Lasers (FEL) at soft and hard X-ray wavelengths driven by a high brightness electron beam imposes strong requirements on the stability of the accelerator and feedback systems are necessary to both guarantee saturation of the SASE process as well as a stable photon beam for user experiments. Diagnostics for the relevant transverse and longitudinal beam parameters are presented and various examples of feedback systems for bunches with low repetition rate as well as systems for intra bunch train feedbacks are discussed.

43 PARTICLE ACCELERATORS↗

Development of high frequency and wide bandwidth Johnson noise thermometry

We develop a high frequency, wide bandwidth radiometer operating at room temperature, which augments the traditional technique of Johnson noise thermometry for nanoscale thermal transport studies. Employing low noise amplifiers and an analog multiplier operating at 2 GHz, auto- and cross-correlated Johnson noise measurements are performed in the temperature range of 3 to 300 K, achieving a sensitivity of 5.5 mK (110 ppm) in 1 s of integration time. This setup allows us to measure the thermal conductance of a boron nitride encapsulated monolayer graphene device over a wide temperature range. Our data show a high power law (T ∼ 4) deviation from the Wiedemann-Franz law above T ∼ 100 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Use of a Solid State Analog Television Transmitter as a Superconducting Electron Gun Power Amplifier

A solid state analog television transmitter designed for 200 MHz operation is being commissioned as a radio frequency power amplifier on the Wisconsin superconducting electron gun cavity. The amplifier consists of three separate radio frequency power combiner cabinets and one monitor and control cabinet. The transmitter employs rugged field effect transistors built into one kilowatt drawers that are individually hot swappable at maximum continuous power output. The total combined power of the transmitter system is 33 kW at 200 MHz, output through a standard coaxial transmission line. A low level radio frequency system is employed to digitally synthesize the 200 MHz signal and precisely control amplitude and phase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High gain and wideband hybrid optical amplifier using bismuth-doped and neodymium-doped fibers for E-band applications

A hybrid dual-stage bismuth-doped fiber and neodymium-doped fiber amplifier with high optical gain and extended bandwidth of operation in the E-band is demonstrated. The amplifier features a maximum gain of 43 dB, output power of 372 mW, and a minimum noise figure of 5.5 dB, and operation wavelength range of 1397–1472 nm, enabled by 153-m of bismuth-doped fiber and two 7-m lengths of neodymium-doped fiber. The demonstration shows the possibility of achieving improved gain bandwidth by combining fiber amplifiers with overlapping gain spectra in the E-band.

Applied optics↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scaling high-energy pulsed solid-state lasers to high average power

Techniques are provided for scaling the average power of high-energy solid-state lasers to high values of average output power while maintaining high efficiency. An exemplary technique combines a gas-cooled-slab amplifier architecture with a pattern of amplifier pumping and extraction in which pumping is continuous and in which only a small fraction of the energy stored in the amplifier is extracted on any one pulse. Efficient operation is achieved by propagating many pulses through the amplifier during each period equal to the fluorescence decay time of the gain medium, so that the preponderance of the energy cycled through the upper laser level decays through extraction by the amplified pulses rather than through fluorescence decay.

Erlandson, Alvin C.↗

Geometric invariants of quantum metrology

Here, we establish a conservation law for the Quantum Fisher Information Matrix (QFIM) expressed as follows; when the QFIM is constructed from a set of observables closed under commutation, i.e., a Lie algebra, the spectrum of the QFIM is invariant under unitary dynamics generated by these same operators. Each Lie algebra therefore endows any quantum state with a fixed “budget” of metrological sensitivity—an intrinsic resource that we show, like optical squeezing in interferometry, cannot be amplified by symmetry-preserving operations. The Uhlmann curvature tensor naturally inherits the same symmetry group, and so quantum incompatibility is similarly fixed. As a result, a metrological analog to Liouville's theorem appears; statistical distances, volumes, and curvatures are invariant under the evolution generated by the Lie algebra. We discuss this as it relates to the quantum analogs of classical optimality criteria. This enables one to efficiently classify useful classes of quantum states at the level of Lie algebras through geometric invariants.

Wilson, Christopher [University of Colorado, Bould↗

Particle simulation of a ka-band gyrotron traveling wave amplifier

The design of a ka-band gyrotron traveling wave (gyro-TWT) amplifier is presented. The gyro-TWT amplifier with a severed structure operates in the fundamental harmonic TE{sub 01} circular electric mode. The beam-wave interaction is studied by using a particle-in-cell (PIC) code. The simulations predict that the amplifier can produce an output peak power of over 155 kW, 22% efficiency, 23 dB gain, and a 3 dB bandwidth of 2 GHz for a 70 kV, 10 A electron beam with an axial velocity spread {Delta}v{sub z}/v{sub z}=5%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗