Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design and Flight Testing of an Inflatable Sunshield for the NGST

The Next Generation Space Telescope (NGST) mission is scheduled to launch in 2007 and be stationed at L2 for a mission life of ten years. The large aperture mirror and optical detectors aboard NGST require shielding from the constant solar energy seen at this orbit. The government reference NGST design, called the Yardstick, baselined a sunshield using an inflation deployment system. During the formulation phase, NGST is spending approximately 25% of the overall budget to foster the development of new technology. The goal is to develop and demonstrate enabling or enhancing technology and provide innovative solutions for the design of the NGST observatory. Inflatable technology falls in the category of enhancing technology due to its advantages in weight, stowed volume and cost. The Inflatable Sunshield in Space (ISIS) flight experiment will provide a realistic space flight demonstration of an inflatable sunshield. The supporting technology development program will provide an information base for the design, manufacture, assembly and testing of large thin membranes and inflatable structural elements for space structures. The ISIS experiment will demonstrate the feasibility of using inflatable technology to passively cool optical systems for NGST and provide correlation between analytical predictions and on orbit results. The experiment will be performed on a Hitchhiker/Space Shuttle mission in late 2001. The ISIS mission is an effort to address several major technical challenges of the NGST inflatable sunshield, namely controlled inflation deployment, plenarity and separation of large stretched membranes, space rigidization of inflatable booms, and dynamic modeling and simulation. This paper will describe the design of the flight experiment and the testing to be performed on-orbit.

Adams, Michael L.↗

Ground Calibration of the Astro-H (Hitomi) Soft X-Ray Spectrometer

The Astro-H (Hitomi) Soft X-ray Spectrometer (SXS) was a pioneering imaging x-ray spectrometer with 5 eV energy resolution at 6 keV. The instrument used a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution non-dispersive spectroscopy in the soft x-ray waveband (0.3-12 keV). We present the suite of ground calibration measurements acquired from 2012-2015, including characterization of the detector system, anti-coincidence detector, optical blocking filters, and filter-wheel filters. The calibration of the 36-pixel silicon thermistor microcalorimeter array includes parameterizations of the energy gain scale and line spread function for each event grade over a range of instrument operating conditions, as well as quantum efficiency measurements. The x-ray transmission of the set of five Al/polyimide thin-film optical blocking filters mounted inside the SXS dewar has been modeled based on measurements at synchrotron beamlines, including with high spectral resolution at the C, N, O, and Al K-edges. In addition, we present the x-ray transmission of the dewar gate valve and of the filters mounted on the SXS filter wheel (external to the dewar), including beryllium, polyimide, and neutral density filters.

detectors↗

Transverse photoresistivity from photothermal current deflection in metal films

Quantum geometry in centrosymmetric systems has motivated the search for photocurrent responses beyond second order. In particular, electric field-induced nonlinear responses may also enable intrinsic polarization-sensitive optical detectors. Despite numerous efforts, clear methods are still needed to remove experimental artifacts, separating intrinsic from extrinsic effects, and disentangling linear responses from their higher-order counterparts. Here, we provide a systematic study of fabrication and measurement techniques to remove external artifacts in photoelectronic responses. This reveals a previously hidden photothermoelectric response in the transverse photoresistivity of symmetric thin films of simple metals. We identify its origin in thermal gradients producing current deflection and determine the device design and measurement parameters to minimize extrinsic effects that arise in photoinduced electronic responses.

Bolometric effect↗

Microbial load monitor

Device can detect and identify a number of medically important microorganisms in an average of approximately 8 hours. Monitor consists of cartridges containing special selective media and solid state electro-optical detectors.

Jones, P. W.↗

The space telescope

Papers concerning the development of the Space Telescope which were presented at the Twenty-first Annual Meeting of the American Astronautical Society in August, 1975 are included. Mission planning, telescope performance, optical detectors, mirror construction, pointing and control systems, data management, and maintenance of the telescope are discussed.

Source record↗

Nuclear Science Symposium, 4th, and Nuclear Power Systems Symposium, 9th, San Francisco, Calif., October 19-21, 1977, Proceedings

Consideration is given to the following types of high energy physics instrumentation: drift chambers, multiwire proportional chambers, calorimeters, optical detectors, ionization and scintillation detectors, solid state detectors, and electronic and digital subsystems. Attention is also paid to reactor instrumentation, nuclear medicine instrumentation, data acquisition systems for nuclear instrumentation, microprocessor applications in nuclear science, environmental instrumentation, control and instrumentation of nuclear power generating stations, and radiation monitoring. Papers are also presented on instrumentation for the High Energy Astronomy Observatory.

Source record↗

Polarization by a tilted absorbing glass plate

Formulas for the response of an optical detector to the transmitted component of a tilted absorbing glass plate are derived in terms of the angle of incidence, the thickness of the plate, and the absorption coefficient and index of refraction of the glass. Numerical results are discussed for detectors of various sizes compared to the width of the incident beam and thickness of the plate.

Walraven, R. L.↗

Overview and outline of Mass-Driver Two

An overview of the Princeton-M.I.T. second mass-driver is presented. Mass-Driver Two is a 13.1 cm caliber system which uses a two coil superconducting bucket and a two-phase in quadrature drive system. Discrete drive coils are individually energized with timing supplied by position-sensing optical detectors. Intermediate energy storage is provided by sector capacitors which are recharged every half cycle by an external power source. A vacuum environment is provided for the superconducting bucket by a 4 inch ID glass pipe with the drive coils surrounding it. Magnetic flight is generated by eddy current repulsion from six copper guide strips lining the glass pipe. The length is 2.5 meters equally divided between acceleration and deceleration sections. Nominal acceleration is 5000 m/sec per sec giving a maximum bucket velocity of 112 m/sec. Regenerative braking is used to decelerate the bucket. Current densities of 25 sq cm are achieved in the superconducting bucket coils and are maintained by a cryogenic service station.

Oneill, G. K.↗

Construction and testing of the 2.5m mass driver

Presented are the designs used in the construction of the 2.5 m mass driver and the results of the initial testing program. The mass driver consists of equal length sections of acceleration and deceleration each containing 59 drive coils of 13.1 cm caliber. Intermediate energy storage is provided by sector capacitors which are recharged every half cycle by an external power source. The drive coils are individually energized through SCR's with timing supplied by position sensing optical detectors. The drive consists of two phases which operate in quadrature. The initial bucket to be propelled through the mass driver contains two coils of aluminum wire chilled to liquid nitrogen temperatures to momentarily sustain superconducting field intensities. Magnetic flight is generated by eddy current repulsion from six copper guide strips lining the mass driver. Nominal acceleration is 5000 m/sec per sec giving a maximum bucket velocity of 112 m/s.

Snow, W. R.↗

Infrared radiometer for the Pioneer Venus orbiter. I - Instrument description

A ten-channel IR radiometer for the Pioneer Venus orbiter is described. The experimental techniques used and the design of the instrumentation by which they were implemented are considered. Emphasis is placed on temperature sounding, limb sounding, limb darkening, zenith scanning, cloud top temperature, spectral albedo and water vapor measurements. Instrumentation description is also given including optics, detectors, and electronics. Attention is given to data acquisition and handling, calibration, and in-flight performance.

Taylor, F. W.↗

Attitude measurement: Principles and sensors

Tools used in the measurement of satellite attitude are described. Attention is given to the elements that characterize an attitude sensor, the references employed (stars, moon, Sun, Earth, magnetic fields, etc.), and the detectors (optical, magnetic, and inertial). Several examples of attitude sensors are described, including sun sensors, star sensors, earth sensors, triaxial magnetometers, and gyrometers. Finally, sensor combinations that make it possible to determine a complete attitude are considered; the SPOT attitude measurement system and a combined CCD star sensor-gyrometer system are discussed.

Duchon, P.↗

Wide field of view laser beacon system for three-dimensional aircraft position measurement

This paper presents a new wide field of view laser beacon system for measurement, in three dimensions, of aircraft or other remote objects. The system is developed for aircraft collision hazard warning independent of ground-based hardware, as well as for flight research, helicopter-assisted construction and rescue, and robotic manipulation applications. Accurate information describing the relative range, elevation, and azimuth of the aircraft are generated by the sweep of a low-power fan-shaped rotating laser beacon past an array of optical detectors. The system achieves a wide angle of acceptance of laser beacon light through use of compound parabolic concentrators, which collimate the light for spectral filtering to minimize solar interference. An on-board microprocessor system converts the pulse sequence to aircraft position in real time. System reliability and performance are enhanced through narrow pass filtering of the pulse signals, digital logic design to mask spurious signals, and adaptive modulation of trigger threshold levels.

Sweet, L. M.↗

Interferometer Measures Broardband Surface Acoustic Waves

Dual differential interferometer uses two pairs of orthogonallypolarized optical beams to measure amplitude and orientation of broadband ultrasonic surface acoustic waves. Instrument modular, and sensitivity limited only by optical detector used.

Claus, R. O.↗

Acousto-optic Extensometer for Bolts

Bolt torque or tension deduced from non contacting measurements. Pulsed Laser induces shockwave in bolthead while continuous-wave acousto-optic detector monitors distortion produced by shock. Shock travel time measured to determine bolt length. Solid-state position detector relatively inexpensive and keeps down cost of extensometer.

Maram, J.↗