Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Industrial deposition of wavelength-shifting films for liquid argon photon detection systems

The Deep Underground Neutrino Experiment (DUNE) Phase-II Far Detector is considering an approximately 2000 m 2 photon detection system to achieve a target mean light yield of 180 PE/MeV. Meeting this requirement demands scalable, cost-effective, and high-quality wavelength-shifter (WLS) coatings capable of converting 127 nm liquid-argon scintillation light into visible photons with controlled and reproducible optical performance. We report on the successful realization of an industrial physical vapor deposition (PVD) process forp-terphenyl (pTP) coatings, adapted from vacuum deposition techniques developed for OLED display manufacturing, to produce uniform WLS layers on large-area inorganic substrates, a task traditionally challenged by adhesion and uniformity issues at organic-inorganic interfaces. Surface characterization by profilometry and spectroscopic measurements demonstrates edge-region thickness variation below 10% and emission spectra consistent with high-quality pTP reference samples. The industrial process demonstrates reproducibility, scalability, and significantly reduced production time compared to laboratory-based methods, while maintaining optical characteristics consistent with established pTP reference samples. These results establish a viable pathway for mass production of high-performance pTP coatings for DUNE FD3 and future neutrino experiments, from a coating manufacturing and process standpoint. Detector-level performance validation, including quantitative VUV conversion efficiency measurements at 127 nm, is identified as future work.

47 OTHER INSTRUMENTATION↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

MIP dQ/dx Calibration in DUNE ND-LAr Prototypes with Pixelated Charge Readout

The Deep Underground Neutrino Experiment (DUNE) will be a next-generation long baseline neutrino oscillation experiment that will employ LArTPC technology in a near detector placed at Fermilab and a far detector at the Sanford Underground Research Facility, at a baseline of 1300 km. The DUNE Liquid Argon Near Detector (ND-LAr) design takes into account the high neutrino intensity expected from the beam at the Long-Baseline Neutrino Facility (LBNF): 35 modules, each containing two optically separated time projection chambers, are instrumented with a pixel-based, true 3D charge readout alongside scintillation light traps to disentangle the O(100) interactions expected per 10us beam spill. A robust prototyping program supports ND-LAr’s design: the 2x2 Demonstrator consists of four scaled-down ND-LAr modules exposed to the NuMI beam at Fermilab, and the Full Scale Demonstrator (FSD) is a single ND-LAr module tested with cosmic rays at the University of Bern. We present here an analysis of minimum ionizing particle (MIP) tracks selected from 2x2 beam data and FSD cosmic ray data used to benchmark the pixel-based charge readout simulation and calibration in both detectors, with the ultimate goal of validating the design of DUNE ND-LAr as well as informing future calibration methods. This poster will showcase the dependence of the charge response on track inclination as well as a per-pixel dQ/dX extraction.

Mandujano, Roberto [UC, Irvine]↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Unusually Strong Near‐Infrared Photoluminescence of Highly Transparent Bulk InSe Flakes

Abstract Bulk γ‐InSe has a direct bandgap of 1.24 eV, which corresponds to near infrared wavelengths ( λ = 1.0 µm) useful in optoelectronic applications from biometric detectors to silicon photonics. However, its potential for optoelectronic applications is largely untapped due in part to the lack of quantitative studies of its optical properties. Here, the unusually low absorptance and high photoluminescence quantum efficiency of single‐crystalline InSe flakes with thickness in the hundreds of nanometers are studied. InSe emits brightly at room temperature from its direct bandgap with a peak photoluminescence quantum yield (PLQY) of 20%, despite displaying indirect bandgap like low absorption coefficient due to the symmetry of its crystal structure. By performing pump‐dependent PLQY measurements, the radiative and nonradiative recombination coefficients are extracted, including the Shockley‐Read‐Hall and Auger coefficients. Finally, a proof‐of‐concept alternating current electroluminescent device at low temperature is demonstrated to show the promise of InSe in optoelectronic technology such as highly transparent, bright NIR light sources.

Geng, Jamie↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray diffraction under grazing incidence conditions

Material properties frequently relate to structures at or near surfaces, particularly in thin films. As a result, it is essential to understand these structures at the molecular and atomistic levels. The most accurate and widely used techniques for characterizing crystallographic order are based on X-ray diffraction. When dealing with thin films or interfaces, standard approaches, such as single crystal or powder diffraction, are not suitable. However, X-ray diffraction under grazing incidence conditions can provide the required information. Here, in this Primer, grazing incidence X-ray diffraction (GIXD) is comprehensively introduced, starting from basic considerations on X-ray diffraction at crystals with reduced dimensionality and the optical properties of X-rays, followed by a more in-depth description of an experimental performance, including X-ray sources, goniometers and detectors. Experimental errors, limitations and reproducibility are discussed. Various applications, from highly ordered inorganic single crystal surfaces to weakly ordered polymer thin films, are presented to illustrate the potential of GIXD. Data visualizations, representations and evaluation strategies are summarized, based on the example of anthracene thin films. The Primer compiles information relevant to perform high-quality GIXD experiments, evaluate data and interpret results, to extend knowledge about X-ray diffraction from surfaces, interfaces and thin films.

36 MATERIALS SCIENCE↗

Machine Learning-Based Extreme Data Reduction for Prompt Supernova Pointing at DUNE

One of the goals of the Deep Underground Neutrino Experiment (DUNE) is to use the massive underground liquid argon time projection chamber (LArTPC) detectors at its far site for multimessenger astronomy (MMA), in the detection of neutrinos from core-collapse supernovae (SNe). Its current baseline trigger strategy detects activity in the detector that is consistent with supernova (SN) neutrinos and saves the raw data for further offline analysis but provides no prompt pointing information crucial for optical follow-ups by other observatories. This approach is based on the assumption that prompt pointing determination using raw data is computationally prohibitive. In this article, we demonstrate a proof-of-concept based on applying extreme data reduction on the buffered SN data in the DUNE data acquisition (DAQ) system’s front-end computers using a machine learning (ML) workflow. This reduces the data by ~5 orders of magnitude, allowing a full track reconstruction to be carried out quickly on a single server. The total time to perform the ML-based data reduction and the full track reconstruction is less than the time to transfer the SN data back to Fermilab or a high-performance computing (HPC) center. This shows that prompt processing of raw SN data is possible and, in fact, trivial once the data have been reduced to reject radiological backgrounds, paving the way to a high-quality SN pointing trigger that is based on fully reconstructed data instead of trigger primitives (TPs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Status of h-BN quasi-bulk crystals and high efficiency neutron detectors

III-nitrides have fomented a revolution in the lighting industry and are poised to make a huge impact in the field of power electronics. In the III-nitride family, the crystal growth and use of hexagonal BN (h-BN) as an ultrawide bandgap (UWBG) semiconductor are much less developed. Bulk crystals of h-BN produced by the high-temperature/high-pressure and the metal flux solution methods possess very high crystalline and optical qualities but are impractical to serve as substrates or for device implementation as their sizes are typically in millimeters. The development of crystal growth technologies for producing thick epitaxial films (or quasi-bulk or semi-bulk crystals) in large wafer sizes with high crystalline quality is a prerequisite for utilizing h-BN as an UWBG electronic material. Compared to traditional III-nitrides, BN has another unique application as solid-state neutron detectors, which however, also require the development of quasi-bulk crystals to provide high detection efficiencies because the theoretical efficiency (ηi) relates to the detector thickness (d) by ηi=1−e−dλ, where λ denotes the thermal neutron absorption length which is 47 μm (237 μm) for 10B-enriched (natural) h-BN. We provide an overview and recent progress toward the development of h-BN quasi-bulk crystals via hydride vapor phase epitaxy (HVPE) growth and the attainment of thermal neutron detectors based on 100 μm thick 10B-enriched h-BN with a record efficiency of 60%. The thermal neutron detection efficiency was shown to enhance at elevated temperatures. Benchmarking the crystalline and optical qualities of h-BN quasi-bulk crystals with the state-of-the-art mm-sized bulk crystal flakes and 0.5 μm thick epitaxial films identified that reducing the density of native defects such as vacancies remains the most critical task for h-BN quasi-bulk crystal growth by HVPE.

Physics↗

Qubit-Based Detector For Dark Matter Search And Radiation Studies

One of the challenges in exploring promising novel materials for dark matter searches is the detection of sub-eV energy excitations from light-dark matter interaction with a target material. Dark matter interaction can excite sub-eV optical phonon modes in polar materials like sapphire. We plan to utilize superconducting qubits on a sapphire substrate to study their response to energy deposition into the superconducting film and the substrate by irradiating them with photons and particles and also generating phonons in the chip. A fraction of the incident energy is expected to break Cooper pairs in the superconductor, releasing quasiparticles. As the quasiparticles tunnel across the Josephson junction, the charge parity of the qubit changes. The parity switching rate is proportional to the quasiparticle density in the qubit superconductor film and can be measured using standard qubit readout protocol. This presentation describes our ongoing attempt to build such a prototype detector.

Khatiwada, Rakshya↗

Characterization and novel application of power over fiber for electronics in a harsh environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at ∼ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer optical power. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency (∼ 51%), and superior isolation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-Ray Spectra of r -process Nuclei

The radioactive decay of unstable nuclei created in the rapid neutron capture process releases a large amount of γ-rays. When the ejecta are optically thick, these γ-rays may contribute to an associated kilonova. Once transparent, prominent spectral features will be directly observable in current and future γ-ray detectors. In this work, we study and compare the γ-ray spectra of different representative r-process trajectories across a broad range of timescales, from hours to 50,000 yr, identifying the nuclei that significantly contribute. We discuss these findings in the context of observability, noting that there are several practical challenges to connecting observed signatures to specific nuclei. However, if these challenges can be overcome, direct observation of γ-rays from r-process sites can provide insight into the fundamental physics underpinning the r-process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗