Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Investigating the origin of the far-field reflection interference fringe (RIF) of microdroplets

We show that the reflection interference fringe (RIF) is formed on a screen far away from the microdroplets placed on a prism-based substrate, which have low contact angles and thin droplet heights, caused by the dual convex–concave profile of the droplet, not a pure convex profile. The geometric formulation shows that the interference fringes are caused by the optical path difference when the reflected rays from the upper convex profile at the droplet–air interface interfere with reflection from the lower concave profile at oblique angles lower than the critical angle. Analytic solutions are obtained for the droplet height and the contact angle out of the fringe number and the fringe radius in RIF from the geometric formulation. Furthermore, the ray tracing simulation is conducted using the custom-designed code. The geometric formulation and the ray tracing show excellent agreement with the experimental observation in the relation between the droplet height and the fringe number and the relation between the contact angle and the fringe radius. This study is remarkable as the droplet's dual profile cannot be easily observed with the existing techniques. However, the RIF technique can effectively verify the existence of a dual profile of the microdroplets in a simple setup. In this work, the RIF technique is successfully developed as a new optical diagnostic technique to determine the microdroplet features, such as the dual profile, the height, the contact angle, the inflection point, and the precursor film thickness, by simply measuring the RIF patterns on the far-field screen.

42 ENGINEERING↗

Measurement of engine-oil fuel dilution using laser induced florescence spectroscopy

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil, or fuel in oil (FiO). Fuel dilution of oil is believed to be one of the underlying mechanisms that promotes low speed pre-ignition (LSPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of transient measurements, the LIF technique resolves transient dilution on the minutes time scale, making it possible to study the relation between FiO and LSPI. The measurement is based on adding a dye (ca. 500 ppm) to the fuel and monitoring for its presence in the oil via LIF. The instrument contains a 532-nm laser diode, and a spectrometer to resolve the LIF spectra. A fiber-optic assembly links the instrument to the engine measurement location; the probe is in a Y-configuration with the six fibers around one on a common probe end that connects to the engine; the Y-assembly legs are connected to the instrument; the two legs are the six fibers for transporting the laser light, and the single fiber for the fluorescence. We have expanded on our previous work (Parks et al, SAE paper 2007-01-4108, 2007), by demonstrating the diagnostic technique with to measure transient oil dilution on a 2.0-liter GM ECOTEC LNF single cylinder SI engine. The proposed LIF diagnostic will be critical in studying oil-dilution correlation with LSPI events.

Neupane, Sneha↗

Kinematics of femtosecond laser-generated plasma expansion: Determination of sub-micron density gradient and collisionality evolution of over-critical laser plasmas

An optical diagnostic based on resonant absorption of laser light in a plasma is introduced and is used for the determination of density scale lengths in the range of 10 nm to >1 μm at the critical surface of an overdense plasma. This diagnostic is also used to extract the plasma collisional frequency, allowing inference of the temporally evolving plasma composition on the tens of femtosecond timescale. This is found to be characterized by two eras: the early time and short scale length expansion (L < 0.1λ), where the interaction is highly collisional and target material dependent, followed by a period of material independent plasma expansion for longer scale lengths (L > 0.1λ); this is consistent with a hydrogen plasma decoupling from the bulk target material. Density gradients and plasma parameters on this scale are of importance to plasma mirror optical performance and comment is made on this theme.

Scott, G. G. (ORCID:000000032772372X)↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

A Sample of Massive Black Holes in Dwarf Galaxies Detected via [Fe x] Coronal Line Emission: Active Galactic Nuclei and/or Tidal Disruption Events

The massive black hole (BH) population in dwarf galaxies ( M BH ≲ 10 5 M ⊙ ) can provide strong constraints on the origin of BH seeds. However, traditional optical searches for active galactic nuclei (AGNs) only reliably detect high-accretion, relatively high-mass BHs in dwarf galaxies with low amounts of star formation, leaving a large portion of the overall BH population in dwarf galaxies relatively unexplored. Here, we present a sample of 81 dwarf galaxies ( M $\star$ ≤ 3 × 10 9 M ⊙ ) with detectable [Fe x]λ6374 coronal line emission indicative of accretion onto massive BHs, only two of which were previously identified as optical AGNs. Here, we analyze optical spectroscopy from the Sloan Digital Sky Survey and find [Fe x]λ6374 luminosities in the range L [Fe x] ≈ 10 36 –10 39 erg s –1 , with a median value of 1.6 × 10 38 erg s –1 . The [Fe x]λ6374 luminosities are generally much too high to be produced by stellar sources, including luminous Type IIn supernovae (SNe). Moreover, based on known SNe rates, we expect at most eight Type IIn SNe in our sample. That said, the [Fe x]λ6374 luminosities are consistent with accretion onto massive BHs from AGNs or tidal disruption events (TDEs). We find additional indicators of BH accretion in some cases using other emission line diagnostics, optical variability, and X-ray and radio emission (or some combination of these). However, many of the galaxies in our sample only have evidence for a massive BH based on their [Fe x]λ6374 luminosities. This work highlights the power of coronal line emission to find BHs in dwarf galaxies missed by other selection techniques and to probe the BH population in bluer, lower-mass dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

A Tabletop Tool for Modeling Life Support Systems

This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations.

Ramachandran, N.↗

Space Laboratory on a Table Top: A Next Generative ECLSS design and diagnostic tool

This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale-time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations. Preliminary experimental and modeling work in this area will be presented. This involves testing of a single inlet-exit model with detailed 3-D flow visualization and quantitative diagnostics and computational modeling of the system.

Ramachandran, N.↗

Microscale Investigation of Thermo-Fluid Transport in the Transition FIL, Region of an Evaporating Capillary Meniscus Using a Microgravity Environment

In order to enhance the fundamental understanding of thin film evaporation and thereby improve the critical design concept for two-phase heat transfer devices, microscale heat and mass transport is to be investigated for the transition film region using state-of-the-art optical diagnostic techniques. By utilizing a microgravity environment, the length scales of the transition film region can be extended sufficiently, from submicron to micron, to probe and measure the microscale transport fields which are affected by intermolecular forces. Extension of the thin film dimensions under microgravity will be achieved by using a conical evaporator made of a thin silicon substrate under which concentric and individually controlled micro-heaters are vapor-deposited to maintain either a constant surface temperature or a controlled temperature variation. Local heat transfer rates, required to maintain the desired wall temperature boundary condition, will be measured and recorded by the concentric thermoresistance heaters controlled by a Wheatstone bridge circuit, The proposed experiment employs a novel technique to maintain a constant liquid volume and liquid pressure in the capillary region of the evaporating meniscus so as to maintain quasi-stationary conditions during measurements on the transition film region. Alternating use of Fizeau interferometry via white and monochromatic light sources will measure the thin film slope and thickness variation, respectively. Molecular Fluorescence Tracking Velocimetry (MFTV), utilizing caged fluorophores of approximately 10-nm in size as seeding particles, will be used to measure the velocity profiles in the thin film region. An optical sectioning technique using confocal microscopy will allow submicron depthwise resolution for the velocity measurements within the film for thicknesses on the order of a few microns. Digital analysis of the fluorescence image-displacement PDFs, as described in the main proposal, can further enhance the depthwise resolution.

Kihm, K. D.↗

Contrails Measurement and Testing Capabilities in NASA's Particulate Aerosol Laboratory

The NASA Glenn Research Center Particulate Aerosol Laboratory (PAL) is a ground test facility for studying emissions and contrails at upper atmospheric conditions. The facility consists of a small-scale combustor that generates hot combustion gases and soot nanoparticles, which flow through a transition pipe into a jet nozzle, which exhausts into an altitude chamber. Thermodynamic conditions experienced in flight are matched in the altitude chamber, allowing the study of ice particle formation of simulated aircraft engine exhaust plumes. A non-intrusive optical diagnostic technique based on Mie scattering provides ice particle size, number density, and mass density. A suite of commercial extractive particle measurement instruments provides estimates of soot number density, size, and black carbon mass distributions. Measurements are presented for various fuels at chamber conditions covering an altitude range of 20,000 ft (6 km) to 45,000 ft (14 km) altitude and ambient temperatures from -48°C to -68°C. The data presented demonstrate the effect of soot number density, altitude, and fuel-to-air equivalence ratio on the contrail ice particle formation. Ice mass density measurements are compared to values predicted by a thermodynamic plume similarity solution.

Optical Instrumentation↗

Representative Phenomena of Cyclic Turbulent Combustion in High-Pressure Fuel Sprays

Abstract Cyclic variations in conventional diesel combustion engines can lead to large differences in engine out emissions even at steady operation. This study uses an optically accessible constant-pressure flow chamber to acquire fuel injections in quick succession to analyze mixing, auto-ignition, and combustion of diesel-surrogate n-heptane using multiple high-speed optical diagnostics. Prior studies have utilized fewer injections and/or they rely on analysis of ensemble average behavior. These approaches do not yield information on injection-to-injection variation or provide confidence in utilizing individual injection measurements for high-fidelity computational fluid dynamics(CFD) model validation. In this study, a large set of 500 injections is used to obtain global parameters including liquid length, vapor penetration length, ignition delay time, and lift-off length. Results for multiple injections are presented to illustrate large injection to injection variations. Potential sources for these variations are analyzed to conclude localized, small scale turbulence and rate of injection variations as the likely sources. Then, a statistical method based on z-scores is proposed and implemented to identify instantaneous injections that best represent the bulk data-set of jet boundaries measured independently by three different diagnostics. This synthesis of statistics-guided screening of data set and ensemble-average analysis offers higher confidence for CFD model validation relying upon both a representative single and average injection results.

42 ENGINEERING↗

Shock-induced kinetics and cellular structures of liquid nitromethane detonation

Using a combination of high-speed diagnostics, optical pyrometry, velocimetry and video photography, we examine the spatiotemporal reaction kinetics of a prototypical high-energy explosive, liquid nitromethane (NM), as we drive this high explosive into detonation. The detonations were initiated by powerful shock waves whose durations (4 ns) were shorter than the characteristic time associated with the reaction (7 ns). Simple optical spectroscopy alone cannot characterize the kinetics with high time resolution because the reactants and products are flowing at a high velocity of ~6 km/s (6 µm/ns). Additionally, every detection volume behind the shock front contains material initiated over a range of times. High spatial resolution can be obtained by probing interfaces where the shock enters or breaks out of the NM. In addition, we obtain cellular patterns imprinted on the luminous shock front by the two-stage explosion in NM. These spatiotemporal patterns arise naturally as a result of the asymmetry produced by the moving shock front. In this way the shock front serves as a thin moving intrinsic optical gauge that reports and characterizes the two-stage NM explosion behind the front.

42 ENGINEERING↗

Fundamental insights on ignition and combustion of natural gas in an active fueled pre-chamber spark-ignition system

Pre-chamber spark-ignition (PCSI), either fueled or non-fueled, is a leading concept with the potential to enable diesel-like efficiency in medium-duty (MD) and heavy-duty (HD) natural gas (NG) engines. However, the inadequate scientific base and simulation tools to describe/predict the underlying processes governing PCSI systems is one of the key barriers to market penetration of PCSI for MD/HD NG engines. To this end, experiments were performed in a heavy-duty, optical, single-cylinder engine fitted with an active fueled PCSI module. Furthermore, the spatial and temporal progress of ignition and subsequent combustion of lean-burn natural gas using PCSI system were studied using optical diagnostic imaging and heat release analysis based on main-chamber and pre-chamber pressure measurements.

42 ENGINEERING↗

Temperature measurements in heavily-sooting ethylene/air flames using synchrotron x-ray fluorescence of krypton

High-fidelity temperature field measurements have been made for several heavily-sooting ethylene/air flames that have historically been challenging environments for conventional optical diagnostics. These challenges have largely been overcome here, in this study, by conducting x-ray fluorescence (XRF) measurements of a Kr fluorescent agent in the hard x-ray regime (15 keV). The current methodology presents a more economical diagnostic than a previously reported implementation of the Kr-XRF method, by limiting seeding of the expensive fluorescent agent to only the fuel stream flows. Detailed reacting flow simulations have been used to interpret experimental signals by tracking the mole fraction of the fluorescent agent in the flow field. Simulated Kr densities are in excellent agreement with measurements throughout the flow field. Temperature measurements of the flow field also agree well with simulations and recent literature studies. However, uncertainties in the measurements become increasingly large downstream of the burner surface as the krypton fraction drops due to mixing of the fuel and co-flow streams. Additionally, we demonstrate that soot particles in the heavily sooting flames studied do not impede the Kr-XRF measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scaling of oxygen-methane reacting coaxial jets using x-ray fluorescence to measure mixture fraction

Stoichiometric mixing length L s of reacting coaxial jet flames is a critical scaling parameter for liquid rocket engine combustors. Previous studies have shown that L s for shear coaxial flames can be scaled like their non-reacting counterparts using a non-dimensional momentum flux ratio J. In addition, stoichiometric mixing lengths of reacting and nonreacting coaxial jets collapse upon a single line by altering J using an effective outer flow gas density. This effective density is calculated from a modified version of the equivalence principle, originally developed by Tacina and Dahm [1, 2] and accounts for the effects of heat release on mixing. However, previous studies also required a second nonphysical scaling constant S c for the reacting jets, which is not predicted by the equivalence principle [3]. It was originally hypothesized that S c is attributed to the limitation of hydroxyl (OH) planar laser-induced fluorescence, which only infers L s . Direct quantitative measurement of conserved scalar fields using conventional optical diagnostics is difficult due to the lack of a tracer that easily fluoresces, survives high temperature oxygen flames, and is not dominated by quenching effects. To measure a conserved scalar field, this work implements x-ray fluorescence of Kr and Ar tracers to obtain quantitative mixture fraction fields. From these mixture fraction fields, stoichiometric mixing lengths for two CH 4 /O 2 flames are calculated and scaled against nonreacting coaxial mixing lengths using the equivalence principle. By directly measuring the stoichiometric mixing length, it is established that the additional constant is a byproduct of the OH measurement technique and the equivalence principle fully captures the scaling. Finally, comparison with high-fidelity simulation of the flame further supports this conclusion. In addition to further strengthening this scaling method, this work represents the first use of x-ray fluorescence to make quantitative conserved scalar measurements in turbulent flames.

33 ADVANCED PROPULSION SYSTEMS↗

Influence of pilot-fuel mixing on the spatio-temporal progression of two-stage autoignition of diesel-sprays in low-reactivity ambient fuel-air mixture

The spatial and temporal locations of autoignition for direct-injection compression-ignition engines depend on fuel chemistry, temperature, pressure, and mixing trajectories in the fuel jets. Dual-fuel systems can provide insight into both fuel-chemistry and physical effects by varying fuel reactivities and engine operating conditions. In this context, the spatial and temporal progression of two-stage autoignition of a diesel-fuel surrogate, n-heptane, in a lean-premixed charge of synthetic natural-gas (NG) and air is imaged in an optically accessible heavy-duty diesel engine. The lean-premixed charge of NG is prepared by fumigation upstream of the engine intake manifold. Optical diagnostics include high-speed (15kfps) cool-flame chemiluminescence-imaging as an indicator of low-temperature heat-release (LTHR) and OH* chemiluminescence-imaging as an indicator high-temperature heat-release (HTHR). NG prolongs the ignition delay of the pilot fuel and increases the combustion duration. Zero-dimensional chemical-kinetics simulations provide further understanding by replicating a Lagrangian perspective for mixtures evolving along streamlines originating either at the fuel nozzle or in the ambient gas, for which the pilot-fuel concentration is either decreasing or increasing, respectively. The zero-dimensional simulations predict that LTHR initiates most likely on the air streamlines before transitioning to HTHR, either on fuel-streamlines or on air-streamlines in regions of near-constant φ. Due to the relatively short pilot-fuel injection-durations, the transient increase in entrainment near the end of injection (entrainment wave) is important for quickly creating auto-ignitable mixtures. To achieve desired combustion characteristics, e.g., multiple ignition-kernels and favorable combustion phasing and location (e.g., for reducing wall heat-transfer or optimizing charge stratification), adjusting injection parameters could tailor mixing trajectories to offset changes in fuel ignition chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the interplay between pilot fuel mixing and auto-ignition chemistry in hydrogen-enriched environment

The diesel-piloted dual-fuel compression ignition combustion strategy is well-suited to accelerate the decarbonization of transportation by adopting hydrogen as a renewable energy carrier into the existing internal combustion engine with minimal engine modifications. Despite the simplicity of engine modification, many questions remain unanswered regarding the optimal pilot injection strategy for reliable ignition with minimum pilot fuel consumption. The present study uses a single-cylinder heavy-duty optical engine to explore the phenomenology and underlying mechanisms governing the pilot fuel ignition and the subsequent combustion of a premixed hydrogen-air charge. The engine is operated in a dual-fuel mode with hydrogen premixed into the engine intake charge with a direct pilot injection of n-heptane as a diesel pilot fuel surrogate. Optical diagnostics used to visualize in-cylinder combustion phenomena include high-speed IR imaging of the pilot fuel spray evolution as well as high-speed HCHO* and OH* chemiluminescence as indicators of low-temperature and high-temperature heat release, respectively. Three pilot injection strategies are compared to explore the effects of pilot fuel mass, injection pressure, and injection duration on the probability and repeatability of successful ignition. The thermodynamic and imaging data analysis supported by zero-dimensional chemical kinetics simulations revealed a complex interplay between the physical and chemical processes governing the pilot fuel ignition process in a hydrogen containing charge. Hydrogen strongly inhibits the ignition of pilot fuel mixtures and therefore requires longer injection duration to create zones with sufficiently high pilot fuel concentration for successful ignition. Results show that ignition typically tends to rely on stochastic pockets with high pilot fuel concentration, which results in poor repeatability of combustion and frequent misfiring. In conclusion, this work has improved the understanding on how the unique chemical properties of hydrogen pose a challenge for maximization of hydrogen’s energy share in hydrogen dual-fuel engines and highlights a potential mitigation pathway.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding the ignition process and flame structure of conventional and oxygenated fuels under engine relevant conditions – An optical study

Renewably generated synthetic fuels such as poly-oxymethylene ethers (OME) have a significant potential to effectively break the soot-NOX trade-off in compression ignition engines by using exhaust gas recirculation (EGR) to maintain low nitrogen oxide (NOX) emissions while maintaining good efficiency and simultaneously contributing to circular carbon economy. However, owing to the fundamental differences in properties of OME when compared to fossil-based diesel fuels, it is critical to fully understand its ignition and combustion phenomenology to take advantage of this fuel to its utmost potential. In this context, this work outlines the results of a systematic experimental study performed in a heavy-duty, single-cylinder, optical engine probing the spatial and temporal progression of fuel decomposition and ignition behavior of OME when compared to n-dodecane, a diesel-fuel surrogate. Thermodynamic analysis and optical diagnostics techniques including simultaneous HCHO-PLIF and OH-PLIF complemented by high-speed OH* chemiluminescence were employed along with parametric sweeps of intake temperature and EGR dilution rates. OME does not exhibit any observable low temperature heat release irrespective of the ambient oxygen concentration. Differences in the observed diffusive flame structure such as longer flame lift-off length, less pronounced combustion recession, faster premixed burn at ignition (“volumetric” ignition), non-sooting behavior suggest that the inherent presence of fuel-bound oxygen in OME can skew the air-fuel ratio (AFR) distribution within the jet thereby reducing the reliance of combustion on mixing and air entrainment. This leads to rapid late-cycle oxidation leading to shorter combustion duration and favorable combustion phasing. Results also suggest that OME exhibits relatively weak negative temperature coefficient (NTC) behavior, however, the OME fuel-decomposition kinetic-pathways produce significant concentration of HCHO, which might be erroneously interpreted as a product of cool-flames.

Air-fuel ratio↗

Online Bayesian State Estimation for Real-Time Monitoring of Growth Kinetics in Thin Film Synthesis

Rapid validation of newly predicted materials through autonomous synthesis requires real-time adaptive control methods that exploit physics knowledge, a capability that is lacking in most systems. Here, in this study, we demonstrate an approach to enable real-time control of thin film synthesis by combining in situ optical diagnostics with a Bayesian state estimation method. We developed a physical model for film growth and applied the direct filter (DF) method for real-time estimation of nucleation and growth rates during pulsed laser deposition (PLD). We validated the approach using simulated and experimental reflectivity data for WSe 2 growth and ultimately deployed the algorithm on an autonomous PLD system during the growth of 1T'-MoTe 2 . The DF robustly estimates growth parameters in real time at early stages of growth, down to 15% monolayer area coverage. This fusion of in situ diagnostics, data assimilation, and physical modeling opens new opportunities in adaptive control of synthesis trajectories toward desired material states.

36 MATERIALS SCIENCE↗