Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A fiber optic sensor for ophthalmic refractive diagnostics

This paper demonstrates the application of a lensless fiber optic spectrometer (sensor) to study the onset of cataracts. This new miniaturized and rugged fiber optic probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for cold-induced cataract in excised bovine eye lenses, and aging effects in excised human eye lenses. The device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics.

Ansari, Rafat R.↗

Recent Developments in X-Ray Diagnostics for Cryogenic and Optically Dense Coaxial Rocket Sprays

The mixing and atomization of propellants is often characterized by optically dense flow fields and complex breakup dynamics. In the development of propulsion systems, the complexity of relevant physics and the range of spatio-temporal scales often makes computational simulation impractical for full scale injector elements; consequently, continued research into improved systems for experimental flow diagnostics is ongoing. One area of non-invasive flow diagnostics which has seen widespread growth is using synchrotron based x-ray diagostics. Over the past 3 years, a series of water and cryogenic based experiments were performed at the Advanced Photon Source, Argonne National Lab, on a NASA in-house designed swirl co-axial rocket injector, designed for operation using liquid oxygen and liquid methane in support of Project Morpheus. A range of techniques, such as x-ray fluorescence and time-averaged radiography were performed providing qualitative and quantitative mass and phase distributions, and were complemented by investigations using time-resolved radiography and white beam imaging, which provided information on breakup and mixing dynamics. Results of these investigations are presented, and conclusions regarding the viability of x-ray based diagnostics are discussed.

Radke, Christopher D.↗

Multi-Spectral Solar Telescope Array. V - Temperature diagnostic response to the optically thin solar plasma

The compact soft X-ray/EUV/FUV multilayer coated telescopes developed for solar chromosphere, corona, and corona/solar-wind interface studies permit the use of conventional (Cassegrain, Herschelian, etc.) configurations. The multilayer coatings also allow a narrow-wavelength band to be selected for imaging. NASA's Multi-Spectral Solar Telescope Array is composed of 17 of these compact telescopes; attention is given to their ability to obtain temperature-diagnostic information concerning the solar plasma.

Deforest, Craig E.↗

Laser anemometry - Advances and applications 1991; Proceedings of the 4th International Conference, Cleveland, OH, Aug. 5-9, 1991. Vols. 1 & 2

The papers presented in this volume provide an overview of the latest advances in laser anemometry and optical flow diagnostics. Topics discussed include turbulence, jets, and chaos; novel optical techniques for velocity measurements; chemical reactions and combusting flows; and LDA/CFD interface. Attention is also given to particle image velocimetry, high speed flows and aerodynamic flows, internal flows, particle sizing, optics and signal processing, two-phase flows, and general fluid mechanics applications.

Dybbs, Alexander↗

The optically thick O III spectrum. I - Diagnostic ratios involving the intercombination lines

An escape-probability calculation of the optically thick O III spectrum is carried out to obtain the optical depth dependence of the intercombination doublet at 1663 A and of resonance lines between the 2p2, 2s2p3, and 2p4 configurations. The effect of optical depth on diagnostic ratios involving the intercombination lines is quantitatively established. The general question raised is whether such effects may occur in actual sources.

Kastner, S. O.↗

Optical property measurements as a diagnostic tool for control of materials processing in space and on Earth

A new method is described, including results, to measure, control, and follow containerless processing in ground based levitators. This technique enables instantaneous optical property measurements from a transient solid or liquid surface concurrent with true temperature measurement. This was used successfully as a diagnostic tool to follow processing of Al, Si, and Ti during electromagnetic levitation. Experiments on Al show the disappearance of the oxide (emittance 0.33) at ca. 1300 C leaving a liquid surface with an emittance of 0.06. Electromagnetic levitation of silicon shows a liquid with a constant emittance (0.2) but with a solid whose emittance decreases very rapidly with increasing temperature. Consequently, the processing of materials at high temperatures can be controlled quite well through the control of surface optical properties.

Krishnan, Shankar↗

'Diamondlike' carbon films - Optical absorption, dielectric properties, and hardness dependence on deposition parameters

An RF plasma deposition system was used to prepare amorphous 'diamondlike' carbon films. The source gases for the RF system include methane, ethylene, propane, and propylene, and the parameters varied were power, dc substrate bias, and postdeposition anneal temperature. Films were deposited on various substrates. The main diagnostics were optical absorption in the visible and in the infrared, admittance as a function of frequency, hardness, and Auger and ESCA spectroscopy. Band gap is found to depend strongly on RF power level and band gaps up to 2.7 eV and hardness up to 7 Mohs were found. There appears to be an inverse relationship between hardness and optical band gap.

Natarajan, V.↗

Holographic, particle imaging and data reduction at Spectron Development Laboratores

Spectron has been deeply involved in the development and use of a wide variety of particle and flow diagnostic, electro optical instruments. Holography and imaging systems have played an important role in this work, but the extraction of data from images and holograms have always presented a limit to their use. Systems and techniques were devised to speed up and automate the extraction of data from holographic and conventional interferograms, particle images and holograms, and other types of optical flow visualization techniques. An IBM/AI based image analyzer was developed that is capable of automatically analyzing many useful image types including interferograms. A key feature of this system is the low total cost of the required hardware. In the particle field work, a commercial diffraction field analyzer was adopted to the image reconstructed from a hologram. This could expand the use of holography in particle diagnostics greatly.

Trolinger, James D.↗

Optical depth of molecular gas in starburst galaxies - Is M82 the prototype?

An attempt is made to survey the CO(2-1) emission toward the centers of 17 IR-luminous galaxies which have previously been detected in CO(1-0). These galaxies span a wide range of size and L(FIR)/L(B) ratio, many have multiple-wavelength studies establishing them as starbursts, and some bear a morphological resemblance to M 82. Nine galaxies are detected and useful upper limits are placed on the remaining eight. Using the CO(2-1)/CO(1-0) ratio of antenna temperature as a diagnostic of optical depth, it is found that all of the galaxies contain predominantly optically thick molecular gas. This implies that the phase of starburst during which the molecular gas is optically thin, currently witnessed in M 82, is either uncommon or short-lived.

Verter, F.↗

Overview of Extractive and Optical PM Measurements from the NASA SE-5 High Pressure Flame Diagnostics Laboratory

Soot emissions measurements of multiphase non-premixed flames are sparse in the literature due to the complexities of sampling in such environments. We present an overview from on-going work at the NASA SE-5 High Pressure Flame Diagnostics laboratory focusing on soot and gaseous emissions at elevated pressures. SE-5 is a gaseous and liquid fueled high pressure flame tube facility capable of operating at pressures up to 880 psia, cooling capacity of 4,000,000 BTU/hr, liquid fuel flow rates up to 2 GPH, and an equivalence ratio range of 0.2 (fuel lean) to 4 (fuel rich). SE-5 provides optical access via four UV-grade fused silica optical windows of the primary reaction zone enabling non-intrusive optical diagnostics of the flame.

Soot↗

Fe I oscillator strengths determined from anomalous dispersion of shock-heated gases.

Determination of Fe I oscillator strengths by the hook method on shock-heated gases. Within the given errors these values agree with oscillator strengths obtained by other methods, including wall-stabilized arc and shock-tube emission, the beam-foil technique, and delayed-coincidence measurements, except that the data reported in the present article tend to be somewhat higher. If it is assumed that no change occurs in atmospheric models, the authors' f-value scale would suggest a solar abundance at the lower limit of the recently published values - namely, log (A sub Fe/A sub H) + 12 = 7.4. This study demonstrates the effectiveness of the hook method for quantitative spectroscopy on shock-heated gases and points up its usefulness for gas diagnostics on optically thick lines.

Huber, M. C. E.↗

Interactive computer modeling of combustion chemistry and coalescence-dispersion modeling of turbulent combustion

An interactive computer code for simulation of a high-intensity turbulent combustor as a single point inhomogeneous stirred reactor was developed from an existing batch processing computer code CDPSR. The interactive CDPSR code was used as a guide for interpretation and direction of DOE-sponsored companion experiments utilizing Xenon tracer with optical laser diagnostic techniques to experimentally determine the appropriate mixing frequency, and for validation of CDPSR as a mixing-chemistry model for a laboratory jet-stirred reactor. The coalescence-dispersion model for finite rate mixing was incorporated into an existing interactive code AVCO-MARK I, to enable simulation of a combustor as a modular array of stirred flow and plug flow elements, each having a prescribed finite mixing frequency, or axial distribution of mixing frequency, as appropriate. Further increase the speed and reliability of the batch kinetics integrator code CREKID was increased by rewriting in vectorized form for execution on a vector or parallel processor, and by incorporating numerical techniques which enhance execution speed by permitting specification of a very low accuracy tolerance.

Pratt, D. T.↗

The development of a fiber optic Raman temperature measurement system for rocket flows

A fiber-optic Raman diagnostic system for H2/O2 rocket flows is currently under development. This system is designed for measurements of temperature and major species concentration in the combustion chamber and part of the nozzle of a 100 Newton thrust rocket currently undergoing tests. This paper describes a measurement system based on the spontaneous Raman scattering phenomenon. An analysis of the principles behind the technique is given. Software is developed to measure temperature and major species concentration by comparing theoretical Raman scattering spectra with experimentally obtained spectra. Equipment selection and experimental approach are summarized. This experimental effort is part of a program, which is in progress, to evaluate Navier-Stokes based analyses for this class of rockets.

De Groot, Wim A.↗

Stabilised electromagnetic levitation at 2-13 MHz

SEL, the Stabilised Electromagnetic Levitator, has been developed to exploit the unique design opportunities available in containerless microgravity experiments. Efficiency and versatility are obtained with multiple coils driven by individual broadband amplifiers whose phase and frequency are controlled. The heating and positioning fields are decoupled. Specimen translation, spin, and for liquids, shape may be adjusted. An open coil structure provides access for optical and diagnostic probes. Results of experiments with a prototype device are discussed. Levitating and heating materials on earth were demonstrated at frequencies up to 13 MHz.

Danley, T. J.↗

Swept shock/boundary-layer interactions: Scaling laws, flowfield structure, and experimental methods

A general review is given of several decades of research on the scaling laws and flowfield structures of swept shock wave/turbulent boundary layer interactions. Attention is further restricted to the experimental study and physical understanding of the steady-state aspects of these flows. The interaction produced by a sharp, upright fin mounted on a flat plate is taken as an archetype. An overall framework of quasiconical symmetry describing such interactions is first developed. Boundary-layer separation, the interaction footprint, Mach number scaling, and Reynolds number scaling are then considered, followed by a discussion of the quasiconical similarity of interactions produced by geometrically-dissimilar shock generators. The detailed structure of these interaction flowfields is next reviewed, and is illustrated by both qualitative visualizations and quantitative flow images in the quasiconical framework. Finally, the experimental techniques used to investigate such flows are reviewed, with emphasis on modern non-intrusive optical flow diagnostics.

Settles, Gary S.↗

Plasma CVD of Carbon Nanotubes

Carbon nanotubes(CNT) exhibit remarkable mechanical and unique electronic properties and thus have created excitement in the research community about their potential in electronics, computing, sensor and structural applications. Realization of these applications critically depends on the ability to control the properties(such as diameter, chirality) as well purity. We have investigated CNT growth using an inductively coupled plasma(ICP) process using hydrocarbon feedstock. The catalyst required for nanotube growth consists of thin sputtered layers of aluminum and iron(10 nm each) and aligned carbon nanotubes have been obtained. Optical emission diagnostics as well as a plasma modeling effort have been undertaken to understand growth mechanisms. This presentation will discuss growth characteristics under various pressure, power and feedgas compositions and our understanding from modeling and diagnostics.

Delzeit, Lance↗

Schlieren System Enhancements at GRC

This presentation describes the latest improvements that have been made to the Schlieren systems at the NASA Glenn Research Center. These systems are used for the visualization of flow and shock structures in our wind tunnel test facilities. Improvements have been made to the optics, light sources and knife edges using the latest state-of-the-art technology. The eventual goal of this upgrade work is to improve the sensitivity of the systems so that they can be used to make quantitative flow measurements.

Schlieren↗