Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical data fusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

High repetition rate mapping of the interaction between a laser plasma and magnetized background plasma via laser induced fluorescence

In this work, the laminar coupling of energy between a laser-produced plasma and a background magnetized plasma was investigated via planar laser induced fluorescence diagnostic and magnetic flux probes. Experiments performed on the Large Plasma Device at the University of California, Los Angeles, mapped out the two-dimensional spatiotemporal evolution of the laser-plasma (debris) ion velocity distribution function (VDF) to assess debris-background coupling in a sub-Alfvénic regime. The acquisition of these data necessitates high repetition rate (1 Hz) as each dataset is the accumulation of thousands of laser shots, which would not be feasible in single-shot experiments. Fully kinetic, three-dimensional particle-in-cell simulations are compared to the measured VDFs to provide a framework in which we can understand the coupling of a sub-Alfvénic plasma flow through a preformed, magnetized plasma. The simulations display the same departure from the expected gyromotion of the debris plasma as observed in the experimental data, and in conjunction with the measured magnetic field traces, have led to the direct observation of the collisionless coupling via laminar fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid retrieval of first-order spatiotemporal distortions for ultrashort laser pulses

High-intensity, ultrashort laser sources are a foundational pillar for High-Energy-Density (HED) physics, and as the repetition-rates of these systems increase, diagnostics must be developed to match their data collection speed. Characterization of any spatiotemporal distortions in the laser pulse is necessary in order to standardize results across facilities. Here, we have previously developed a laser diagnostic called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, or STRIPED FISH, to measure the full spatiotemporal laser electric field on a single shot. In order to provide rapid feedback, we here adapt the STRIPED FISH retrieval algorithm, which typically has computation times of up to 30 minutes due to the high spatial resolution of the device and its retrieval of the complete four-dimensional pulse field, to distill the key electric field quantities into a handful of scalars for rapid assessment of the pulse's first order distortions. Here, our new, rapid non-iterative retrieval algorithm is validated with simulated and experimental data, and it provides, within seconds, the same first-order information as given by the full analysis. This algorithm is suitable for on-shot assessment of spatiotemporal distortions and can be adapted to assess high repetition-rate laser quality in HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and modeling of indirectly driven magnetized implosions on the NIF

The use of magnetic fields to improve the performance of hohlraum-driven implosions on the National Ignition Facility (NIF) is discussed. The focus is on magnetically insulated inertial confinement fusion, where the primary field effect is to reduce electron-thermal and alpha-particle loss from the compressed hotspot (magnetic pressure is of secondary importance). We summarize the requirements to achieve this state. The design of recent NIF magnetized hohlraum experiments is presented. These are close to earlier shots in the three-shock, high-adiabat (BigFoot) campaign, subject to the constraints that magnetized NIF targets must be fielded at room-temperature, and use ≲1 MJ of laser energy to avoid the risk of optics damage from stimulated Brillouin scattering. We present results from the original magnetized hohlraum platform, as well as a later variant that gives a higher hotspot temperature. In both platforms, imposed fields (at the capsule center) of up to 28 T increase the fusion yield and hotspot temperature. Integrated radiation-magneto-hydrodynamic modeling with the Lasnex code of these shots is shown, where laser power multipliers and a saturation clamp on cross-beam energy transfer are developed to match the time of peak capsule emission and the P2 Legendre moment of the hotspot x-ray image. The resulting fusion yield and ion temperature agree decently with the measured relative effects of the field, although the absolute simulated yields are higher than the data by 2.0−2.7×. The tuned parameters and yield discrepancy are comparable for experiments with and without an imposed field, indicating the model adequately captures the field effects. Self-generated and imposed fields are added sequentially to simulations of one BigFoot NIF shot to understand how they alter target dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing laser-heated polymer foams with simultaneous x-ray fluorescence spectroscopy and Thomson scattering at the Matter in Extreme Conditions Endstation at LCLS

Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Fabrication of glass gas cells for the HALOE and MAPS satellite experiments

The Halogen Occultation Experiment (HALOE) and the Measurement of Air Pollution from Satellites (MAPS) experiment are satellite-borne experiments which measure trace constituents in the Earth's atmosphere. The instruments which obtain the data for these experiments are based on the gas filter correlation radiometer measurement technique. In this technique, small samples of the gases of interest are encapsulated in glass cylinders, called gas cells, which act as very selective optical filters. This report describes the techniques employed in the fabrication of the gas cells for the HALOE and MAPS instruments. Details of the method used to fuse the sapphire windows (required for IR transmission) to the glass cell bodies are presented along with detailed descriptions of the jigs and fixtures used during the assembly process. The techniques and equipment used for window inspection and for pairing the HALOE windows are discussed. Cell body materials and the steps involved in preparing the cell bodies for the glass-to-sapphire fusion process are given.

Sullivan, E. M.↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MAB Phase Ceramics for Lunar Applications

During the ten-week internship my work focused on designing characterization protocol for 3D printed MAB phase ceramics on steel and Tiplates. I was mentored by Dr. Samuel Hocker of NASA and advised by Dr. Gupta from University of North Dakota. I also collaborated with Mackenzie Short from the University of North Dakota. The characterization protocol was divided into following steps; initially, we performed visual inspection of the plates. During this process, the coatings which spalled or delaminated were discarded for further evaluation. During the next step, we performed optical microscopy to discern and document surface features and porosities of the samples. We also noted some decomposition under the optical microscope as well. Thereafter, profilometry analysis was performed to understand the effect of power density on the surface roughness. Due to the deposited powder over the samples, the profilometry was inconclusive. We then cleaned the samples on the steel plate using ethanol and cotton swabs to wipe up the loose powder covering the samples. Detailed SEM analysis was then performed on the cleaned specimens. In parallel, the 3D printed samples on the Tiplate were cleaned by using an ultrasonic bath for 1h. Optical imaging showed that this cleaning process was more effective for cleaning except that small cracks propagated through the layered ceramics. The profilometry data gathered on the titanium plate after cleaning was more conclusive. The SEM data on the steel plate showed that there is decomposition at all wattages although at 100 W the extent of decomposition was lower. We are planning to characterize the steel samples after cleaning in ultrasonic bath for 5-10 min to minimize cracking during the cleaning process. In addition, we are also planning to study the fractured surface by SEM analysis.

Additive Manufacturing, Laser Powder Bed Fusion, S↗

DisasterAWARE – A Global Alerting Platform for Flood Events

The rising number of flooding events combined with increased urbanization is contributing to significant economic losses due to damages to structures and infrastructures. From a risk reduction and resilience perspective, it is not only essential to forecast flood risk and potential impacts, but also to disseminate the information to stakeholders on the ground for rapid implementation of mitigation and response measures. This paper provides (i) an introduction to DisasterAWARE®, a global alerting system, that is used to disseminate flood risk information to stakeholders across the globe, and (ii) a discussion of the models implemented using earth observation data (Synthetic Aperture Radar and optical imagery) for near real-time assessment of flood severity and potential flood impacts to infrastructures. While the models are still in their nascent stage, a case study implementation of the models for the 2020 flooding event in Africa is presented to showcase the model integration with DisasterAWARE®.

54 ENVIRONMENTAL SCIENCES↗

Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens

The BHx streak tube, under development at the Laboratory for Laser Energetics, incorporates a series of novel electron-optics elements to enable high fidelity measurements for high-energy-density physics experiments. The system is engineered to support a 25-mm active photocathode region compatible with sub-picosecond temporal resolution and with 70% internal photoelectron throughput. It exhibits negligible geometric distortion on a flat output screen, making it well suited for variety of measurements, such as ultrafast x-ray spectroscopy. Here, this paper presents characterization data from a prototype unit tested with an ultraviolet laser in a static deflection (non-swept) mode and shows good agreement with the predictions from numerical modeling, including focusing performance and geometric distortion measurements. Key design elements have been demonstrated and de-risked, laying the foundation for dynamic deflection testing. The anticipated improvements in data fidelity are expected to impact the fields as diverse as inertial confinement fusion, laboratory astrophysics, and materials science.

High energy density physics↗

Nondestructive Modular Leak Detection in 3D Printed 316L Stainless Steel Pipes via Laser Powder Bed Fusion

This research investigates the leak detection features of 316L Stainless Steel pipe structures manufactured via Laser Powder Bed Fusion (LPBF). This work involves the design of a modular sensor system integrating nondestructive evaluation (NDE) methods, including thermal imaging and ultrasonic frequency detection to detect and characterize leaks in components. This aims to improve leak detection sensitivity within medium-pressure gas systems, during continuous operation without halting flow or introducing safety risks. The system could be adaptable for use on unmanned aerial vehicles (UAVs), enabling remote leak detection in active environments. A custom pneumatic system incorporating temperature and pressure sensors was assembled to detect leaks in LPBF-printed 316L SS tee pipes. Experimental results and simulations confirm the system’s effectiveness in leak detection and material evaluation. This research program also integrated a Python-based image recognition platform based on a metallography and optical microscopy to assess the porosity and complement the leak detection data on the printed structures. This allows a detailed analysis of pore distribution and internal leak paths, which could compromise structural integrity, critical for quality control during manufacturing. Findings suggest that the investigated approach holds potential for enhancing leak detection technologies and adapt them for advanced manufactured parts.

36 MATERIALS SCIENCE↗

Report on laser-induced fluorescence transitions relevant for the microelectronics industry and sustainability applications

A wide variety of feed gases are used to generate low-temperature plasmas for the microelectronics and sustainability applications. These plasmas often have a complex combination of reactive and nonreactive species which may have spatial and temporal variations in density, temperature, and energy. Accurate knowledge of these parameters and their variations is critically important for understanding and advancing these applications through validated and predictive modeling and the design of relevant devices. Laser-induced fluorescence (LIF) provides both spatial and temporally resolved information about the plasma-produced radicals, ions, and metastables. However, the use of this powerful diagnostic tool requires the knowledge of optical transitions including excitation and fluorescence wavelengths which may not be available or scattered through a huge literature domain. In this paper, we collected, analyzed, and compiled the available transitions for laser-induced fluorescence for more than 160 chemical species relevant to the microelectronics industry and the sustainability applications. A list of species with overlapping LIF excitations and fluorescence wavelengths have been identified. Finally, this summary is intended to serve as a data reference for LIF transitions and should be updated in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of the Impact of Discontinuity in Satellite Instruments and Retrievals on Global PM2.5

Exposure to fine particulate matter (PM2.5) is the leading environmental risk factor for mortality globally. Satellite-derived estimates of surface PM2.5 developed from a combination of satellites, simulations, and ground monitor data are relied upon for health impact studies. The ability to develop satellite-derived PM2.5 estimates requires the continued availability of aerosol optical depth (AOD) sources. This work examines the impact of the addition or loss of satellite AOD data sources on global PM2.5 estimation and the impact of continuing the longterm record with AOD from the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi-National Polar orbiting Partnership (S-NPP) satellite after the loss of the MODIS (MODerate resolution Imaging Spectroradiometer) and MISR (Multi-angle Imaging Spectroradiometer) instruments on board the Terra and Aqua satellites. We find that the addition of VIIRS S-NPP AOD products to geophysical PM2.5 estimates from satellites and simulations causes regional differences that correspond to differences in the VIIRS and MODIS Deep Blue AOD algorithms and sampling. Changes in long-term trends and timeseries due to the addition or loss of AOD data sources are generally within their uncertainties. Statistical fusion with ground monitor data partially corrects for changes due to sampling differences when introducing the VIIRS AOD products, but uncertainty remains over desert regions where ground monitor coverage is sparse. This work provides promise for the sustained development of global satellite-derived PM2.5 estimates, despite discontinuities in instruments and retrieval methods.

Remote sensing↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconciling calculations and measurements of inverse bremsstrahlung absorption

It was recently shown that the use of Coulomb logarithms appropriate for bremsstrahlung radiation (rather than transport processes) along with corrections for the Langdon effect and ion screening reproduced measurements of collisional absorption in well-characterized underdense plasmas [D. Turnbull et al., Phys. Rev. Lett. 130, 145103 (2023)]. However, it was recognized at the time that the use of the standard absorption-reduction factor from Langdon's seminal paper was inconsistent with the use of Coulomb logarithms that are thermally averaged over a Maxwellian electron-velocity distribution function. A more accurate approach would be to average over the expected super-Gaussian distribution function while accounting for the Gaunt factor's velocity dependence, which somewhat mitigates the Langdon effect; however, at that time, this theory matched the data less well. This conflict is now eliminated with the additional insight that the ionization state of our mid-Z ion species (when present) was lower than had been assumed, as evidenced by the Thomson-scattering data and time-dependent Cretin simulations. We are now able to show that an improved treatment of the Langdon effect provides the best match to data. Otherwise, the prior conclusions remain unchanged. We also show an example of the substantial expected impact to the absorption rate in calculations of indirect-drive hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manufacturing and Mechanical Testing of TC1225/LM-PAEK and TC1200/PEEK Thermoplastic Composite Panels

Development of thermoplastic composites (TPCs) for aerospace structures is experiencing renewed enthusiasm attributed to the availability of rapid manufacturing technology, ease of joining through fusion welding processes, and the successful utilization of the material in flight critical structures. Semicrystalline thermoplastics such as polyether ether ketone (PEEK), polyether ketone ketone (PEKK), and polyphenylene sulfide (PPS) have been successfully demonstrated as thermoplastic skins, keel beams, and angle brackets for commercial aircraft. Composite specimens were fabricated from the Toray TC1225 and TC1200 unidirectional prepreg systems and tested to gain confidence with NASA in-house TPC processing as part of the Thermoplastics Development for Exploration Application (TDEA) project. TC1225 is a relatively new material system that uses T700GC fibers and low-melt polyaryl ether ketone (LM-PAEK) resin. TC1200 is the latest version of a material system that has been available for several decades with AS4 fibers and PEEK resin. Results for ultrasonic inspection, optical microscopy, acid digestion, and differential scanning calorimetry establish the quality of the panels. Mechanical test data for unnotched and notched laminate tension and compression as well as compression after impact provide data for equivalency assessment and support material selection in TDEA. Satisfactory equivalence of the TC1225 results and the National Center for Advanced Materials Performance (NCAMP) database was found. The results indicate high-quality manufacturing was achieved, and the resulting mechanical test data are in agreement with that in the literature.

Thermoplastic Composites↗

Characterization of an imploding cylindrical plasma for electron transport studies using x-ray emission spectroscopy

We report here on the characterization of the conditions of an imploding cylindrical plasma by time-resolved x-ray emission spectroscopy. Knowledge about this implosion platform can be applied to studies of particle transport for inertial confinement fusion schemes or to astrophysical plasmas. A cylindrical Cl-doped CH foam within a tube of solid CH was irradiated by 36 beams (I total ~5×10 14 W/cm 2 , 1.5ns square pulse, and E total ~ 16.2kJ) of the OMEGA-60 laser to radially compress the CH toward the axis. The analysis of the time-resolved spectra showed that the compression can be described by four distinct phases, each presenting different plasma conditions. First the ablation of the cylinder is dominant; second, the foam is heated and induces a significant jump in emission intensities; third, the temperature and density of the foam reaches a maximum; and finally, the plasma expands. Ranges for the plasma temperature were inferred with the atomic physics code SCRAM (Spectroscopic Collisional-Radiative Atomic Model) and the experimental data have been compared to hydrodynamic simulations performed with the 2D code FLASH, which showed a similar implosion dynamic over time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗