Search NASA⌕ Search

SEARCH · Search NASA

Results for “Organic liquid electrolyte”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

NMR and Theoretical Study of In-Pore Diffusivity of Ionic Liquid–Solvent Mixtures

We report despite having a lower energy density than common batteries, electric double-layer capacitors (EDLCs) offer several advantages for high-power applications, including high power density, quick charge and discharge time, and long cycle life. Room-temperature ionic liquids (RTILs) have been intensely studied as promising electrolytes for applications in ELDCs because of their wide potential window, low volatility, as well as thermal and chemical stability. The main deficiency of neat RTILs in such applications is the sluggish diffusivity, which restricts the EDLCs’ power density. To alleviate the slow diffusivity, RTILs can be used in a mixture with organic solvents. In this study, we applied two-dimensional exchange nuclear magnetic resonance spectroscopy (2D EXSY NMR) and molecular dynamics (MD) simulations to investigate the diffusivity of anions of an RTIL, namely, 1-butyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)imide (BMIM + –TFSI – ), dissolved in five different organic solvents, in the micropores of activated carbon. We determined that the relative concentrations of ions in solutions in the micropores were higher than those in the bulk solutions and were also solvent-dependent. The ion diffusivities in the pores were found to be almost 2 orders of magnitude slower than in the bulk solutions, with methanol showing the largest relative disparity. These results suggested that the interactions of solvents with the activated carbon are critical not only to the power density of EDLCs but also to the energy density. The comparisons of ion diffusivities between the experiments and the MD simulations suggest the need to consider also the surface functionalities of activated carbon for the simulation of ion diffusion in the micropores of activated carbon.

electric double layer capacitors↗

Literature Review Investigating Historical Plutonium Solubility in SRS Tank Waste

The Savannah River Site (SRS) has designed the Accelerated Basin De-inventory (ABD) program to accelerate the de-inventory of L-Basin and accelerate the Spent Nuclear Fuel (SNF) disposition mission. Similarly, the H-Canyon facility at SRS is reestablishing the 6.3D electrolytic dissolver for dissolving unirradiated stainless-steel (SS) clad Fast Critical Assembly (FCA) fuel. In both discard types (ABD and FCA), plutonium is present and its complex solubility when composited to Concentration, Storage, and Transfer Facility (CSTF) sludge is being investigated as it may have downstream impacts to the liquid waste (LW) organization. This literature review aims to highlight and compile the existing literature on plutonium solubility in waste streams relevant to ABD and FCA discards, as well as discuss some considerations in analyzing solubility data of plutonium. This review serves to help define the analysis methods for future experiments involving plutonium (and other actinides) and in designing appropriate testing conditions surrounding these studies. This review is broken up into five parts and will discuss: (i) The possible effects of testing hold time and temperature on plutonium solubility, (ii) the influence of neutralization rate and particle size of freshly precipitated discards, (iii) the coprecipitation of plutonium with iron and uranium, (iv) predictive solubility modeling and the influence of supernate anions on solubility, and (v) the speciation of plutonium in solutionas a result of supernate anions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mass action model of solution activity via speciation by solvation and ion pairing equilibria

Abstract Solutes and their concentrations influence many natural and anthropogenic solution processes. Electrolyte and solution models are used to quantify and predict such behavior. Here we present a mechanistic solution model based on mass action equilibria. Solvation and ion pairing are used to model speciated solute and solvent concentrations such that they correlate to a solution’s vapor pressure (solvent activity) according to Raoult’s law from dilute conditions to saturation. This model introduces a hydration equilibrium constant ( K ha ) that is used with either an ion dissociation constant ( K id ) or a hydration modifier ( m ) with an experimentally determined ion dissociation constant, as adjustable parameters to fit vapor–liquid equilibrium data. The modeled solvation equilibria are accompanied by molecular dynamics (MD) studies that support a decline in the observed degree of solvation with increased concentration. MD calculations indicate this finding is a combination of a solvent that solvates multiple solutes, and changes in a solute’s solvation sphere, with the dominant factor changing with concentration. This speciation-based solution model is lateral to established electrostatics-based electrolyte theories. With its basis in mass action, the model can directly relate experimental data to the modeled solute and solvent speciated concentrations and structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Addressing the sensitivity of signals from solid/liquid ambient pressure XPS (APXPS) measurement

Ambient pressure XPS has demonstrated its great potential in probing the solid/liquid interface, which is a central piece in electrocatalytic, corrosion, and energy storage systems. Additionally, despite the advantage of ambient pressure XPS being a surface sensitive characterization technique, the ability of differentiating the surface adsorbed species (~Å scale) and bulk electrolyte (~10 nm scale) in the spectrum depends on the delicate balance between bulk solution concentration (C), surface coverage (θ), bulk liquid layer thickness (L), and inelastic mean free path (λ) as a function of photon energy. By investigating a model system of gold dissolving in a bromide solution, the connection between theoretical prediction at the atomic resolution and macroscopic observable spectrum is established.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Fast Critical Assembly Fuel Discards on Liquid Waste Processes

The Savannah River Nuclear Solutions (SRNS) Fast Critical Assembly (FCA) mission is reestablishing the electrolytic dissolver for processing of Pu and Pu-U materials clad in stainless steel (SS). H-Canyon is planning to dissolve and neutralize FCA fuel without recovering the special nuclear material (i.e., Pu) prior to discarding to the Concentration, Storage, and Transfer Facilities (CSTF) operated by the Savannah River Mission Completion (SRMC) Liquid Waste (LW) Organization. The FCA discards will be combined with sludge in the CSTF after Low Temperature Aluminum Dissolution (LTAD) if needed. The combined waste will be washed, concentrated, and vitrified at the Defense Waste Processing Facility (DWPF). The high level waste canisters produced will be temporarily stored in the Glass Waste Storage Buildings prior to transfer to a future federal repository. Decants from LTAD and sludge washing will be combined with DWPF recycle and dissolved salt cake to prepare salt batches for processing in the Salt Waste Processing Facility. The resulting decontaminated salt solution will be processed in the Saltstone Production Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of liquid conductance on the temporal evolution of self-organization patterns in atmospheric pressure DC glow discharges

Abstract Self-Organized Patterns (SOPs) at plasma-liquid interface in atmospheric pressure plasma discharges refer to the formation of intricate and puzzling structures due to the interplay of electrodynamic and hydrodynamic processes. Studies conducted to date have shown that this phenomenon results in the formation of distinctive patterns such as circular ring, star, gear, dots, spikes, etc., and primarily depends on working gas, electrolyte type, gap distance, current, conductivity, etc. However, an adequate understanding of how these patterns change from one type to another is still not available. This study aims to elucidate the influence of initial liquid conductance ( σ i ) on the temporal evolution of SOPs in liquid-anode discharges. The discharge was generated in a pin-to-liquid anode configuration at a constant helium (He) flow rate of 500 sccm and DC applied voltage of 6 kV at a gap distance of 12 mm. Through the gradual increment of σ i from 1.8 μ S to 4820 μ S, we observe that the trend in the evolution of SOPS takes place as solid discs, spikes, dots, rings, double rings, and stars. The continuous formation of reactive species onto the liquid anode in all conductive solutions results in a decrease in pH, an increase in bulk liquid temperature, and an increase in total dissolved solutes, and these have been confirmed through experimental measurements. Observations using optical emission spectroscopy show that the electrons at the plasma-liquid interface participate in the reduction of cations followed by their excitation & ionization due to which electron density as well as emissions from excited species (mainly hydroxyl radicals & excited nitrogen) decrease with time. Our investigation provides experimental evidence on the presence of cations at the plasma-liquid interface required for SOP formation.

Physics↗

Structure–Capacitance Relationships of Graphene/Ionic Liquid Electrolyte Double Layers

The differential capacitance profile of electrochemical interfaces reflects the physical properties of the double layer. For carbon electrodes and ionic liquid based electrolytes, these capacitance profiles are not fully understood. In this work, we utilize constant voltage molecular dynamics simulations to compute differential capacitance profiles of ionic liquids [BMIm + ][BF 4 - ] and [BMIm + ][TFSI - ] mixed with acetonitrile and 1,2-dichloroethane, at model graphene electrodes. We find that both pure and 10% mole fraction ionic liquid electrolytes exhibit camel shaped capacitance profiles with two peaks on either side of a minimum centered at the potential of zero charge. This profile shape results from electric field induced rearrangement of ion structure within the inner layer closest to the electrode interface. At low potential, the ionic liquid inner layer is concentrated with non-polar tri-fluoromethyl and butyl functional groups of the anions and cations, corresponding to the minimum of the capacitance profiles. With increasing voltage, electrostatic interactions of polar/charged functional groups with the electrode surface compete with these non-polar interactions, leading to ion rearrangement that increases the inner layer charge density and results in higher capacitance. After the ion restructuring is complete, the response saturates and capacitance diminishes. The presence of organic solvent significantly changes the composition of the inner layer. For example, strong non-polar interactions between dichloroethane molecules and the graphene surface substantially block ion/electrode contact at moderate potentials. Overall, our simulations highlight the dynamic nature of the inner region of organic electrolyte double layers, and the sensitive dependence on electrolyte composition and applied voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Densification Pressure Optimization of MOF-808-Based Membranes for Lithium Metal Batteries

The use of metal–organic frameworks (MOFs) in hybrid electrolytes for lithium (Li) metal batteries has grown in prominence in recent years, primarily due to the chemical tunability of the MOF’s pore structures, which can directly influence Li–ion transport properties. The most attractive form factor for a MOF electrolyte is a thin, flexible membrane, which requires the application of pressure to increase the contact between the MOF particles. Herein, a systematic study of the influence of pressure on the properties of MOF-808-based membranes is presented. It is shown that when a dry, roll-pressed membrane is subjected to pressure ≥120 MPa, a total loss of crystallinity and a significant loss of porosity is observed. Alternatively, a slurry-cast membrane, compressed under controlled pressures, can maintain crystallinity and porosity while decreasing the interparticle void space. Interesting, the conductivity of the membranes infiltrated with liquid electrolyte is not greatly affected by the pressure applied, though ultimately it is shown that for cycling with Li metal, compressed membranes with compact particles are preferred. In conclusion, this study highlights the critical importance of controlling the pressure applied to MOF-based membranes during fabrication and during cell assembly and lays out the foundation for further investigation of how to optimize membrane fabrication for hybrid electrolytes that use MOFs as the dominate component.

25 ENERGY STORAGE↗

Characterizing Hygroscopic Films of Polyzwitterions in Electric Fields Using Neutron and X-ray Reflectometries: Electrostriction or Mass Loss?

Herein we study responses of thermally annealed ultrathin films deposited on silicon substrates and containing polyzwitterions to applied electric fields by using specular neutron reflectometry (NR). In particular, we applied 7 kV under vacuum at 150 °C on the films containing poly(1-(3-sulfonatopropyl)-2-vinylpyridinium) (P2VPPS) and its blends with either a deuterated ionic liquid (EMIMBF 4 - d 11 ), potassium bromide (KBr), or deuterated sodium polystyrenesulfonate (NaPSS-d 7 ). The voltage was applied over an air gap, and the in situ neutron reflectivity measurements allowed us to measure changes in the films. In all the cases, we measured decreases in thicknesses of the films, which varied up to ~8% depending on the added salt. Posteriori X-ray reflectivity (XRR) measurements on the same films at room temperature reveal that these films were highly hygroscopic, which led to the presence of water in these films. Analysis of the NR and the XRR revealed that the decrease in the thickness of the films in the neutron reflectivity experiments on heating resulted from the loss of water and the ionic liquid but not from electrostrictive effects. The in situ NR and posteriori XRR experiments revealed not only the hygroscopic nature of these films but also depth-resolved structural rearrangements due to the applied electric fields in the films containing electrolytes and polyelectrolytes. This work shows that a combination of NR and XRR can be used to distinguish between mass loss and electrostriction in films containing charged polymers such as polyzwitterions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cathode–Sulfide Solid Electrolyte Interfacial Instability: Challenges and Solutions

All-solid-state batteries are a candidate for next-generation energy-storage devices due to potential improvements in energy density and safety compared to current battery technologies. Due to their high ionic conductivity and potential scalability through slurry processing routes, sulfide solid-state electrolytes are promising to replace traditional liquid electrolytes and enable All-solid-state batteries, but stability of cathode-sulfide solid-state electrolytes interfaces requires further improvement. Herein we review common issues encountered at cathode-sulfide SE interfaces and strategies to alleviate these issues.

25 ENERGY STORAGE↗

Electrochemical Cycling of Liquid Organic Hydrogen Carriers as a Sustainable Approach for Hydrogen Storage and Transportation

Hydrogen (H 2 ), as a high-energy-density molecule, offers a clean solution to carry energy. However, the high diffusivity and low volumetric density of H 2 pose a challenge for long-term storage and transportation. Liquid organic hydrogen carriers (LOHCs) have been suggested as a strategic way to store and transport hydrogen in stable molecules. More so, electrochemical LOHC cycling renders an opportunity to utilize renewable energy for hydrogen storage and transportation toward the goal of eliminating carbon emissions. In this Perspective, examples of electrochemical reactions of organic molecules and their suitability for LOHC couples are examined. A comparative carbon footprint assessment of electrochemical LOHC cycling processes against thermochemical and hybrid LOHC cycling processes was performed. The electrochemical LOHC cycling process had the lowest relative carbon footprint only when highly concentrated LOHCs were used as the feed or when purification of the LOHC product was not required. The carbon footprint in electrochemical cycling of diluted LOHC was primarily contributed to by the LOHC distillation separation process. A sensitivity analysis showed the carbon footprint LOHC concentration dependence during the electrochemical cycling process. Moreover, the electrolyte composition significantly affects the carbon footprint during electrochemical LOHC cycling. Energy utilization, water usage, and toxicity for electrochemical LOHC cycling are discussed to provide an overview for better economic and environmental practices. There are significant opportunities in the electrochemical cycling of LOHCs if appropriate conditions such as high concentrations of reactant, reversible redox cycling ability, high Faradaic efficiencies, and catalyst stabilities are achieved.

25 ENERGY STORAGE↗

Strongly Correlated Ion Dynamics in Plastic Ionic Crystals and Polymerized Ionic Liquids

Understanding the mechanisms controlling ionic conductivity is critical for the development of the next generation of batteries and supercapacitors. This paper discusses the significant role played by ionic correlations in conductivity of concentrated ionic systems. Our studies of an organic ionic plastic crystal reveal that correlations in ions dynamics suppress conductivity by 25–100 times in comparison to the expected uncorrelated ionic conductivity estimated from the Nernst–Einstein relationship. Furthermore, additional analysis also demonstrates that ionic correlations suppress conductivity in polymerized ionic liquids and gel by ~10 times. Thus, ionic correlations, usually neglected in many studies, play a very important role in conductivity of concentrated ionic systems. These results cannot be explained by a diffusion of ion pairs because all these systems are essentially single ion conductors. In contrast, strongly correlated motions of mobile ions with the same charge (cation–cation or anion–anion correlations) are the major mechanism suppressing the ionic conductivity in these systems. Finally, on the basis of these results, we emphasize that charge transport rather than ion diffusion is critical for electrolyte performance and suggest the potential design of plastic crystals and polymer electrolytes with enhanced ionic conductivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Superionic Conductivity in Lithium and Sodium Salts of Weakly Coordinating Closo -Hexahalocarbaborate Anions

Solid-state ion conductors based on closo-polyborate anions combine high ionic conductivity with a rich array of tunable properties. Cation mobility in these systems is intimately related to the strength of the interaction with the neighboring anionic network and the energy for reorganizing the coordination polyhedra. In this paper, we explore such factors in solid electrolytes with two anions of the weakest coordinating ability, [HCB 11 H 5 Cl 6 ] – and [HCB 11 H 5 Br 6 ] – , and a total of 11 polymorphs are identified for their lithium and sodium salts. Our approach combines ab initio molecular dynamics, synchrotron X-ray powder diffraction, differential scanning calorimetry, and AC impedance measurements to investigate their structures, phase-transition behavior, anion orientational mobilities, and ionic conductivities. We find that M(HCB 11 H 5 X 6 ) (M = Li, Na, X = Cl, Br) compounds exhibit order–disorder polymorphic transitions between 203 and 305 °C and display Li and Na superionic conductivity in the disordered state. Through detailed analysis, we illustrate how cation disordering in these compounds originates from a competitive interplay among the lattice symmetry, the anion reorientational mobility, the geometric and electronic asymmetry of the anion, and the polarizability of the halogen atoms. These factors are compared to other closo-polyborate-based ion conductors to suggest guidelines for optimizing the cation–anion interaction for fast ion mobility. This study expands the known solid-state poly(carba)borate-based materials capable of liquid-like ionic conductivities, unravels the mechanisms responsible for fast ion transport, and provides insights into the development of practical superionic solid electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybrid electrolytes for group 2 cation-based electrochemical energy storage device

This invention relates to the field of energy storage devices, and especially electrochemical energy storage devices including electrolytes comprising an ionic liquid, one or more solvents, and one or more salts of a Group 2 element. Effects on electrochemical performance of the electrolyte of each of the components of the electrolyte were systematically determined. In addition, interactions between the electrolytes and separator films were dissected to optimize electrochemical performance of coin cell batteries.

25 ENERGY STORAGE↗

Molten Salt Electrolytes: Computational Analysis of Transport, Electrochemical Properties and Designing New Mixtures

Electric aircraft propulsion has gained a traction over the last decade due to possible high-energy density electrochemistries with reasonable cycle life and identification of non-flammable chemistries that can guarantee much better safety. Commercial Li-ion batteries cannot reach such high capacities because of weight limitations that arise from the widely used intercalation electrodes. Also, use of organic electrolytes make them highly susceptible to fire on exposure to air and humidity. Currently, use of Lithium metal anode along with conversion electrochemistries such as Li-O2 and Li-S are being pursued to achieve such high energy densities. Safer inorganic solid-state electrolytes, recently discovered Water-in-Salt electrolytes, molten salt electrolytes are some of the alternatives being pursued for a safer/non-flammable battery. Of these safer alternatives, molten-salt electrolytes offer some attractive properties: liquid at operating temperatures resulting in better electrode-wetting, stable interface with Li-metal anodes and good ionic conductivity; their only drawback being high operating temperatures. In this talk, we will discuss some of the computational studies, driven via atomistic simulations, of the properties of molten-salt electrolytes including transport mechanism and interface stability. We will also discuss predicting electrochemical properties of these high-temperature electrolytes. Further, we will discuss a thermodynamic approach to predicting new molten-salt eutectics with lower melting points.

Molten Salt Electrolytes↗

Alkali Cation-Mediated Modulation of CO 2 Reduction Activity on Tin Electrodes in [EMIM][BF 4 ]/H 2 O Electrolytes

The development of efficient CO 2 reduction technologies hinges upon a thorough understanding of the intricate interplay between solution cations and the characteristics of the electrode surface. Recently, ionic liquids (ILs) have emerged as promising electrolytes for the CO 2 reduction reaction. However, the effect of alkali cations on the electrochemical CO 2 reduction (CO 2 R) reaction remains unclear in ILs. Here, in this report, we studied alkali cation effects by assessing the electrocatalytic CO 2 R activity with the IL 1-ethyl-3-methylimidazolium tetrafluoroborate, [EMIM][BF 4 ], in water with alkali metal co-cations (i.e., Li + , Na + , and K + ) using a polycrystalline Sn catalyst. Contrary to previous findings in purely aqueous media with inorganic cations, where alkali cations strongly enhance CO 2 R via pH modulation and strengthening of interfacial electric fields, alkali cations in electrolytes containing the IL [EMIM][BF4] negatively impact CO 2 R activity on Sn electrodes. These results were attributed to the larger radius and higher concentration of the IL organic cation [EMIM] + that mitigates the impact of alkali cations. These findings highlight the complex interplay between IL cations and alkali metals in shaping CO 2 R performance.

Chemistry↗

Non-thermal atmospheric pressure plasma–liquid synthesis of organic acids in aqueous solution from carbon monoxide

This work aims at understanding the conversion of CO to organic acids, namely oxalic acid and formic acid, using non-thermal atmospheric pressure plasma over aqueous solutions. CO exhibited significantly higher conversion to organic acids (more than 15×) compared to CO 2 under the same reaction conditions. The result bolsters a proposed two-step process for CO 2 fixation, whereby CO 2 is first converted to CO, and then CO is converted to organic acids. The organic acids produced from CO are intermediates in the water–gas shift (WGS) reaction of CO in the presence of an aqueous solution to dissolved CO 2 and hydrogen gas. Based on a simple thermodynamic analysis, the organic acid yield was increased by lowering the plasma–liquid reaction temperature using an ice bath to cool the reaction flask. The composition of the organic acids could be varied by changing the pH of the solution. Oxalate was formed in higher concentrations with increasing solution pH above the pK a of the radical species (CO 2 )˙ − . Below the pK a value, formate was the exclusive organic acid formed. The production of formate has a rather weak pH dependence but is enhanced slightly at a basic pH above 10. Furthermore, at basic pH, the effect of electrolyte concentration comes into play. Higher electrolyte concentrations, leading to shorter electrolyte Debye lengths, resulted in lowered organic acid yields. The highest yields of organic acids obtained in our system were 122 mg L −1 for oxalate and 77 mg L −1 for formate at an optimum 1 mM NaOH concentration in the starting solution. This work is a successful pioneering example of CO to organic acids conversion using non-thermal plasmas, which opens the pathway for a promising two-step conversion process of CO 2 to organic acids.

Sudagar, Alcina Johnson [Washington University in ↗

Anhydrous Proton-Conducting Membranes for Fuel Cells

Polymeric electrolyte membranes that do not depend on water for conduction of protons are undergoing development for use in fuel cells. Prior polymeric electrolyte fuel-cell membranes (e.g., those that contain perfluorosulfonic acid) depend on water and must be limited to operation below a temperature of 125 C because they retain water poorly at higher temperatures. In contrast, the present developmental anhydrous membranes are expected to function well at temperatures up to 200 C. The developmental membranes exploit a hopping-and-reorganization proton- conduction process that can occur in the solid state in organic amine salts and is similar to a proton-conduction process in a liquid. This process was studied during the 1970s, but until now, there has been no report of exploiting organic amine salts for proton conduction in fuel cells.

Narayanan, Sekharipuram↗