Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARALLEL OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Internal motions of HII regions and giant HII regions

We report new echelle observations of the kinematics of 30 HII regions in the Large Magellanic Clouds (LMC), including the 30 Doradus giant HII region. All of the HII regions possess supersonic velocity dispersions, which can be attributed to a combination of turbulent motions and discrete velocity splitting produced by stellar winds and/or embedded supernova remnants (SNRs). The core of 30 Dor is unique, with a complex velocity structure that parallels its chaotic optical morphology. We use our calibrated echelle data to measure the physical properties and energetic requirements of these velocity structures. The most spectacular structures in 30 Dor are several fast expanding shells, which appear to be produced at least partially by SNRs.

Chu, You-Hua↗

X-Ray Absorbed, Broad-Lined, Red AGN and the Cosmic X-ray Background

This award represents the second phase of an X-ray study of QSOs that are heavily obscured in the optical/near-IR. An earlier survey revealed that these active galactic nuclei (AGN) are also typically strongly absorbed at high photon energies, but the enhanced sensitivity of XMM-Newton provided for the first time the opportunity to measure the spectral indices of individual sources and to test the possibility that obscured AGN are responsible for a substantial portion of the cosmic X-ray background (CXRB). The new observations confirm and greatly extend the earlier results. Substantial intervening absorbing material is detected for 3 of the sources, and 2 additional targets show hard power-law continua. In addition, soft X-ray excesses are detected in 3 of sources, indicating the presence of extended regions of ionized gas. This component is-particularly well-defined in the Type 1 source 2MASS2344+1221, allowing analysis and modeling at a level of detail unusual for such distant sources. An important finding that parallels conclusions from optical polarimetry is the lack of dependence of absorption on optical spectral class (Type 1 or 2). The combination of strong polarization and X-ray absorption in sources that show strong, broad emission lines indicates either a very small (nuclear) absorber or a favored viewing angle which allows the X-ray source to be covered but the surrounding broad emission-line region to be largely exposed. The observed spectral also indicate that obscured AGN of both Type 1 and 2 contribute significantly to the CXRB at higher X-ray energies.

Schmidt, Gary D.↗

(abstract) Neptune: CO and HCN Distributions from Observations at the CSO

We used the Caltech Submillimeter Observatory (CSO ) to make spatially unresolved observations of the 230.538 GHz 2-1 transition of CO and the 265.886 GHz 3-2 transition of HCN at Neptune. All observations used the 10.4 meter antenna with a double sideband SIS junction heterodyne receiver. Spectra were observed with parallel acousto-optic spectrometers simultaneously providing 580 MHz bandwidth at 0.57 MHz resolution and 50 MHz bandwidth at 0.049 MHz resolution. Observed line shapes agree with prior observations by Rosenqvist et al and Marten et al. Analysis of the line shapes and intensities will yield information about the distributions of CO and HCN in the stratosphere of Neptune, and these results will be compared with previous results. The data imply that the mixing ratios of CO and HCN must decrease with altitude somewhere within the pressure range from 1 to 0.001 mbar. HCN data will also address the sharp saturation-induced decrease in the HCN mixing ratio at the lower levels in the stratosphere.

Caltech Submillimeter Observatory SRO CO carbon mo↗

Range-Measuring Video Sensors

Optoelectronic sensors of a proposed type would perform the functions of both electronic cameras and triangulation- type laser range finders. That is to say, these sensors would both (1) generate ordinary video or snapshot digital images and (2) measure the distances to selected spots in the images. These sensors would be well suited to use on robots that are required to measure distances to targets in their work spaces. In addition, these sensors could be used for all the purposes for which electronic cameras have been used heretofore. The simplest sensor of this type, illustrated schematically in the upper part of the figure, would include a laser, an electronic camera (either video or snapshot), a frame-grabber/image-capturing circuit, an image-data-storage memory circuit, and an image-data processor. There would be no moving parts. The laser would be positioned at a lateral distance d to one side of the camera and would be aimed parallel to the optical axis of the camera. When the range of a target in the field of view of the camera was required, the laser would be turned on and an image of the target would be stored and preprocessed to locate the angle (a) between the optical axis and the line of sight to the centroid of the laser spot.

Howard, Richard T.↗

BioSentinel: Biosensors for Deep-Space Radiation Study

The BioSentinel mission will be deployed on NASA's Exploration Mission 1 (EM-1) in 2018. We will use the budding yeast, Saccharomyces cerevisiae, as a biosensor to study the effect of deep-space radiation on living cells. The BioSentinel mission will be the first investigation of a biological response to space radiation outside Low Earth Orbit (LEO) in over 40 years. Radiation can cause damage such as double stand breaks (DSBs) on DNA. The yeast cell was chosen for this mission because it is genetically controllable, shares homology with human cells in its DNA repair pathways, and can be stored in a desiccated state for long durations. Three yeast strains will be stored dry in multiple microfluidic cards: a wild type control strain, a mutant defective strain that cannot repair DSBs, and a biosensor strain that can only grow if it gets DSB-and-repair events occurring near a specific gene. Growth and metabolic activity of each strain will be measured by a 3-color LED optical detection system. Parallel experiments will be done on the International Space Station and on Earth so that we can compare the results to that of deep space. One of our main objectives is to characterize the microfluidic card activation sequence before the mission. To increase the sensitivity of yeast cells as biosensors, desiccated yeast in each card will be resuspended in a rehydration buffer. After several weeks, the rehydration buffer will be exchanged with a growth medium in order to measure yeast growth and metabolic activity. We are currently working on a time-course experiment to better understand the effects of the rehydration buffer on the response to ionizing radiation. We will resuspend the dried yeast in our rehydration medium over a period of time; then each week, we will measure the viability and ionizing radiation sensitivity of different yeast strains taken from this rehydration buffer. The data obtained in this study will be useful in finalizing the card activation sequence for this mission.

Yeast↗

Forced convection and transport effects during hyperbaric laser chemical vapor deposition

This work explores mass transport processes during HP-LCYD, including the transverse forced-flow of precursor gases through a nozzle to enhance fiber growth rates. The use of laser trapping and suspension of nano-scale particles in the precursor flow is also described, providing insights into the nature of the gas flow, including jetting from the fiber tip and thermodiffusion processes near the reaction zone. The effects of differing molecular-weight buffer gases is also explored in conjunction with the Soret effect, and it is found that nucleation at the deposit surface (and homogeneous nucleation in the gas phase) can be enhanced/ retarded, depending on the buffer gas molecular weight. To demonstrate that extensive microstructures can be grown simultaneously, three-dimensional fiber arrays are also grown in-parallel using diffractive optics--without delatory effects from neighboring reaction sites.

36 MATERIALS SCIENCE↗

The dynamics and stability of radiatively driven gas clouds. I - Plane-parallel slabs

A combination of numerical and analytical techniques has been used to investigate the dynamics and stability of optically thin plane-parallel radiatively driven slabs of gas confined by the thermal gas pressure of a high-temperature low-density medium. Scaling laws allow the individual model 'clouds' to be characterized by a single free parameter, chi, a normalized column density which measures the strength of the acceleration due to radiation pressure relative to that due to thermal gas pressure. It is found that these clouds are stable and coherently accelerated only when chi is small. In this regime a simple slab model is constructed which accurately reproduces the more complex gasdynamic results. The low-chi clouds are marginally able to reach the high velocities seen in the atmospheres of quasi-stellar objects, but only if their motion is subsonic with respect to the external confining medium. This implies either that the medium is extremely hot and tenuous or that it is moving outward with the clouds.

Haas, M. R.↗

Hardware and Methods of the Optical End-to-End Test of the Far Ultraviolet Spectroscopic Explorer (FUSE)

The Far Ultraviolet Spectroscopic Explorer (FUSE), currently being tested and scheduled for a 1999 launch, is an astrophysics satellite designed to provide high spectral resolving power (Lambda/(Delta)Lambda = 24,000-30,000) over the interval 90.5-118.7 nm. The FUSE optical path consists of four co-aligned, normal incidence, off-axis parabolic, primary mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographic gratings and delay line microchannel plate detectors. We describe the hardware and methods used for the optical end-to-end test of the FUSE instrument during satellite integration and test. Cost and schedule constraints forced us to devise a simplified version of the planned optical test which occurred in parallel with satellite thermal-vacuum testing. The optical test employed a collimator assembly which consisted of four co-aligned, 15" Cassegrain telescopes which were positioned above the FUSE instrument, providing a collimated beam for each optical channel. A windowed UV light source, remotely adjustable in three axes, was mounted at the focal plane of each collimator. Problems with the UV light sources, including high F-number and window failures, were the only major difficulties encountered during the test. The test succeeded in uncovering a significant problem with the secondary structure used for the instrument closeout cavity and, furthermore, showed that the mechanical solution was successful. The hardware was also used extensively for simulations of science observations, providing both UV light for spectra and visible light for the fine error sensor camera.

Conard, Steven J.↗

Opto-electronic morphological processor

The opto-electronic morphological processor of the present invention is capable of receiving optical inputs and emitting optical outputs. The use of optics allows implementation of parallel input/output, thereby overcoming a major bottleneck in prior art image processing systems. The processor consists of three components, namely, detectors, morphological operators and modulators. The detectors and operators are fabricated on a silicon VLSI chip and implement the optical input and morphological operations. A layer of ferro-electric liquid crystals is integrated with a silicon chip to provide the optical modulation. The implementation of the image processing operators in electronics leads to a wide range of applications and the use of optical connections allows cascadability of these parallel opto-electronic image processing components and high speed operation. Such an opto-electronic morphological processor may be used as the pre-processing stage in an image recognition system. In one example disclosed herein, the optical input/optical output morphological processor of the invention is interfaced with a binary phase-only correlator to produce an image recognition system.

Yu, Jeffrey W.↗

Discorpy : algorithms and software for camera calibration and correction

Camera or lens-based detector calibration is essential for spatial accuracy in applications like dimensional tomography, optical metrology, and computer vision. Many methods and software exist yet there is still a lack of approaches that achieve both high accuracy and robustness while being easy to use and capable of handling a wide range of distortions. Radial lens distortion is common in high-resolution X-ray detector optics used in parallel-beam tomography at synchrotrons. Achieving sub-pixel accuracy requires calibrating with an optical target image. Although methods for characterizing radial distortion are well established, acquired images often also include perspective distortion and optical center offset. Here, we present our approaches to individually characterize and correct both types of distortion using a single calibration image, implemented in the Discorpy software.

36 MATERIALS SCIENCE↗

Comparison of optics and electronics for the calculation of matrix-vector products

Optical processors are attractive because of their ability to perform massively parallel operations such as matrix vector products. The inherently analog nature of optical calculations requires that optical processors be based on analog computations. While the speed at which such analog operations can be performed as well as the natural parallelism of optical systems are great advantages of optical processors, the analog representation of values severely limits the achievable accuracy. Furthermore, optical processors are limited by the need to convert information to and from the intensity of light. Digitization can be used to increase the accuracy of optical matrix-vector processors, but causes a severe reduction in speed. This paper compares the throughput and power requirements of optical and electronic processors, showing that optical matrix-vector processors can provide a greater number of operations/Watt than conventional electronics.

Gary, C. K.↗

Optical computing with laser light

Linear and nonlinear optical processing techniques (Fourier transformation, convolution and correlation, arithmetic operations - addition and subtraction with gratings, generalized orthogonal transformations; theta modulation, half-tone screen process, optical feedback) for mathematical computations are reviewed. The use of gratings and computer holograms in addition, subtraction, differentiation, and application of generalized transformations is discussed. Use of nonlinear optical elements with or without optical coherent feedback in such nonlinear operations as taking logarithms and thresholding is described. Applications in hybrid systems incorporating digital computer and optical processor with real-time interface devices, or optical threshold and logic devices for parallel processing to apply digital techniques to optical information are considered.

Lee, S. H.↗

Advanced miniature processing handware for ATR applications

A Hybrid Optoelectronic Neural Object Recognition System (HONORS), is disclosed, comprising two major building blocks: (1) an advanced grayscale optical correlator (OC) and (2) a massively parallel three-dimensional neural-processor. The optical correlator, with its inherent advantages in parallel processing and shift invariance, is used for target of interest (TOI) detection and segmentation. The three-dimensional neural-processor, with its robust neural learning capability, is used for target classification and identification. The hybrid optoelectronic neural object recognition system, with its powerful combination of optical processing and neural networks, enables real-time, large frame, automatic target recognition (ATR).

Chao, Tien-Hsin↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Investigations into the feasibility of optical-CT 3D dosimetry with minimal use of refractively matched fluids

Purpose: In optical-CT, the use of a refractively matched polyurethane solid-tank in place of a fluid bath has the potential to greatly increase practical convenience, reduce cost, and possibly improve the efficacy of flood corrections. This work investigates the feasibility of solid-tank optical-CT imaging for 3D dosimetry through computer simulation. Methods: A MATLAB ray-tracing simulation platform, ScanSim, was used to model a parallel-source telecentric optical-CT imaging system through a polyurethane solid-tank containing a central cylindrical hollow into which PRESAGE radiochromic dosimeters can be placed. A small amount of fluid fills the 1–5 mm gap between the dosimeter and the walls of the tank. The use of the solid-tank reduces the required amount of fluid by approximately 97%. To characterize the efficacy of solid-tank, optical-CT scanning simulations investigated sensitivity to refractive index (RI) mismatches between dosimeter, solid-tank, and fluid, for a variety of dosimeter (RI = 1.5–1.47) and fluid (RI = 1.55–1.0) combinations. Efficacy was evaluated through the usable radius (r{sub u}) metric, defined as the fraction of the radius of the dosimeter where measured dose is predicted to be within 2% of the ground truth entered into the simulation. Additional simulations examined the effect of increasing gap size (1–5 mm) between the dosimeter and solid-tank well. The effects of changing the lens tolerance (0.5°–5.0°) were also investigated. Results: As the RI mismatch between the dosimeter and solid-tank increased from 0 to 0.02, the usable radius decreased from 97.6% to 50.2%. The optimal fluid RI decreased nonlinearly from 1.5 to 1.34 as the mismatch increased and was up to 9% lower than the tank. Media mismatches between the dosimeter and solid-tank also exacerbate the effects of changing the gap size, with no easily quantifiable relationship with usable radius. Generally, the optimal fluid RI value increases as gap size increases and is closely matched to the dosimeter at large gap sizes (>3 mm). Increasing the telecentric lens tolerance increases the usable radius for all refractive media combinations and improves the maximum usable radius of mismatched media to that of perfectly matched media for tolerances >5.0°. The maximum usable radius can be improved up to a factor of 2 when lens tolerances are small (<1.0°). Conclusions: Dry solid-tank optical-CT imaging in a telecentric system is feasible if the dosimeter RI is a close match with the solid-tank (<0.01 difference), providing accurate dose measurements within ±2% of true dose to over 80% of the dosimeter volume. In order to achieve accurate measurements over 96% of the dosimeter volume (representing out to 2 mm from the dosimeter edge), the dosimeter-tank RI mismatch must be less than 0.005. Optimal results occur when the RI of the dosimeter and tank is the same, in which case the fluid will have the same RI. If mismatches between the tank and dosimeter RI occur, the RI of the matching fluid needs to be fine tuned to achieve the highest usable radius.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phonon coupling to dynamic short-range polar order in a relaxor ferroelectric near the morphotropic phase boundary

We report neutron inelastic scattering experiments on single-crystal PbMg 1/3 Nb 2/3 O 3 doped with 32% PbTiO 3 , a relaxor ferroelectric that lies close to the morphotropic phase boundary. When cooled under an electric field E∥ [001] into tetragonal and monoclinic phases, the scattering cross section from transverse acoustic (TA) phonons polarized parallel to E weakens and shifts to higher energy relative to that under zero-field-cooled conditions. Likewise, the scattering cross section from transverse optic (TO) phonons polarized parallel to E weakens for energy transfers 4 ≤ ℏω ≤ 9 meV. However, TA and TO phonons polarized perpendicular to E show no change. This anisotropic field response is similar to that of the diffuse scattering cross section, which, as previously reported, is suppressed when polarized parallel to E but not when polarized perpendicular to E. Lastly, our findings suggest that the lattice dynamics and dynamic short-range polar correlations that give rise to the diffuse scattering are coupled.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anisotropy of Optical Activity in Langasite Family Crystals

The rotation of the plane of polarization of light transmitted in the directions parallel (ρ{sub ||}) and perpendicular (ρ{sub ⊥}) to the optical axis has been calculated for langasite family crystals. It is shown that the ρ{sub ||} and ρ{sub ⊥} values are, respectively, negative and positive for all the right-handed crystals under study. An analysis of the interatomic potential constructed based on X-ray diffraction data has suggested that this anisotropy of optical activity is structurally based of electron density regions shaped as helices. The atomic helix with an axis parallel to the optical axis is right-handed and three-start, whereas in the direction perpendicular to the optical axis there are three left-handed two-start helices, which intersect in the origin of the unit-cell coordinate system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗