Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA FOCUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The inverse skin effect in the Z-pinch and plasma focus

The inverse skin effect and its influence on the dynamics of high-current Z-pinch and plasma focus discharges in deuterium are analyzed. It is shown that the second compression responsible for the major fraction of the neutron yield can be interpreted as a result of the inverse skin effect resulting in the axial concentration of the longitudinal current density and the appearance of a reversed current in the outer layers of plasma pinches. Possible conditions leading to the enhancement of the inverse skin effect and accessible for experimental verification by modern diagnostics are formulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Common features of particle beams and x-rays generated in a low energy dense plasma focus device

Features of energetic charged particle beams and x-ray emission in a low energy (1–2 kJ) plasma focus (DPF) device are described and the possible mechanism are explained based on circuit analyses and energy balance in the DPF system. In particular, the resistance and the voltage across the plasma column are estimated to explain the mechanisms of the generation of particle beams and hard x-ray. The analysis shows that the total inductance of a DPF might have played a role for enhancement of the particle beams and x-ray emissions during the phase of anomalous resistance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repetitive Nanofocus: Evidence of neutron and x-ray emission from an ultra miniature pinch plasma focus discharge operating at tens of Hz

Evidence of x-ray and neutron emission from an ultraminiature pinch plasma focus is presented. The stored energy in the device is less than 1J per shot and can be operated at tens of Hz of repetition rate. The main features of this device, repetitive Nanofocus, are 5nF of capacity, 5nH of inductance, 5-10 kV charging voltage, 60-250 mJ stored energy, 5-10 kA current peak, per shot. The device has been operated at 20 Hz in hydrogen and deuterium. X-ray radiographs of materials of different thickness were obtained. Neutrons were detected using a system based upon {sup 3}He proportional counter in current mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of bismuth nanospheres deposited by plasma focus device

A new method for producing thin layer of bismuth nanospheres based on the use of low energy plasma focus device is demonstrated. Various techniques such as scanning electron microscopy, Rutherford backscattering spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy have been used to characterize the morphology and the composition of the nanospheres. Experimental parameters may be adjusted to favour the formation of bismuth nanospheres instead of microspheres. Therefore, the formation of large surface of homogeneous layer of bismuth nanospheres with sizes of below 100 nm can be obtained. The natural snowball phenomenon is observed to be reproduced in nanoscale where spheres roll over the small nanospheres and grow up to bigger sizes that can reach micro dimensions. The comet-like structure, a reverse phenomenon to snowball is also observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ determination of the static inductance and resistance of a plasma focus capacitor bank

The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L{sub 0}, and resistance r{sub 0} to be obtained using lightly damped sinusoid equations given the bank capacitance C{sub 0}. However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Carbonitriding of silicon using plasma focus device

Carbonitride thin films have been deposited on silicon substrate by the irradiation of energetic nitrogen ions emanated from dense plasma focus device. The carbon ions are ablated by the irradiation of relativistic electrons from the insert material (graphite) placed at the anode tip. The x-ray diffraction analysis demonstrates that a polycrystalline thin film consisting of various compounds such as Si{sub 3}N{sub 4}, SiC, and C{sub 3}N{sub 4} is formed on the silicon (100) substrate. Crystallinity of different compounds decreases with the increase in angular positions (0 deg., 10 deg., and 20 deg. ). Raman spectroscopy shows the appearance of graphitic and disordered bands with silicon nitride and silicon carbide indicating the formation of carbonitride. Raman spectra also indicate that broadening of bands increases with the increase in focus deposition shots, leading to the amorphization of the thin film. The amorphization of the thin films depends on the ion energy flux as well as on the sample angular position. The scanning electron microscopy exhibits the damaging of the substrate surface at 0 deg. angular position. The microstructure shows the tubular shape for higher ion dose (40 focus shots). At 10 deg. angular position, a two phase phenomenon is observed with the ordered phase in the solid solution. A smooth and uniform surface morphology showing a small cluster is observed for the 20 deg. angular position.

36 MATERIALS SCIENCE↗

Dose Measurements in a 20-J Repetitive Plasma Focus

In this article, the results of X-ray dose measurements executed using thermoluminescent dosimeters in experiments with a very small (20 J) repetitive plasma focus device named SORENA-1 are presented and analyzed. The working gas in these experiments was Argon. Also, pinch formation in experiments with this device has been observed. This device has been designed and constructed in Plasma and Nuclear Fusion Research School of Nuclear Science and Technology Research Institute of Iran. From these results, it is concluded that we can do experiments with this device using Ar as working gas all over the working days of year, and a good symmetry for measured dose around the device has been seen.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rethinking radiation effects in materials science using the plasma-focused ion beam

This work demonstrates the viability of using a plasma-focused ion beam (PFIB) as a new platform to carry out radiation effects studies in solids. While materials subjected to irradiation in either nuclear reactors or energetic particle accelerators experience limitations with respect to inaccuracies in both flux measurements and lack of precise control of irradiation areas, we demonstrate a new irradiation technique that allows the exposure of a single specimen in multiple areas, at multiple doses, and in site-specific dependencies - all with flux variations on the order of only 1%. This versatile technique also allows materials to be exposed to significantly higher irradiation dose rates than conventional accelerators. To validate the new methodology, we selected the classical example of ion-beam-induced amorphization of pure single-crystal Si. By pioneering the use of the PFIB for radiation effects studies in materials science, we were able to exploit, in both micro- and nanometer-sized detail, the differences in electron image contrast arising from crystalline versus amorphous solid-state phases in classical semiconductors subjected to irradiation, thus providing new insights on amorphization mechanisms. This methodology opens new research frontiers at the fringe of materials science with promising applications beyond the scope of materials at extremes such as in nanopatterning, nanodevices and nanoarchitectonics.

36 MATERIALS SCIENCE↗

Trajectories of high energy electrons in a plasma focus

Measurements are made of high-energy electron trajectories in a plasma focus as functions of position, time, energy, and angle of emission. The spatial resolution of the X-ray emission shows that low-energy X-rays are emitted from the anode surface. It is also suggested that the highest energy X-rays originate from a small region on the axis. The so-called shadow technique shows that the electron beam is perpendicular to the anode surface. Polar diagrams of medium and high-energy X-rays agree with the bremsstrahlung emission from a relativistic electron beam, the current of which is several 100 A.

Harries, W. L.↗

Magnetic and neutron measurements on the PF-400 plasma focus facility

Parasitic currents shunting up to one-half of the total discharge current were detected using magnetic probes on a Filippov-type plasma focus facility with a maximum total current of 1 MA and stored energy of 80 kJ. The measured time dependence of neutron emission from the discharge indicates that the parameters of the neutron pulse are closely related to those of the imploding current sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Pyrex and quartz insulators contamination effect on the X-ray intensity in a 4-kJ plasma focus device

The variation of the X-ray intensity has been investigated with the Pyrex and quartz insulators surface contamination in a 4-kJ plasma focus device with argon gas at 11.5-kV charging voltage. Elemental analysis (EDAX) showed that the Cu evaporated from the electrode material and was deposited on the sleeve surface improves the breakdown conditions. A small level of sleeve contamination by copper is found to be essential for good focusing action and high HXR intensity. The SEM imaging showed the grain-type structure of Cu formed on the surface and it changed the surface property. Resistance measurements of original and coated Pyrex surface proved that the copper deposition on the sleeve surface will reduce its resistance as compared to the almost infinitely large resistance of the uncontaminated sleeve. As the contamination is surpassed to some critical level, the HXR intensity from the device is deteriorated.

36 MATERIALS SCIENCE↗

Axial magnetic field and toroidally streaming fast ions in the dense plasma focus are natural consequences of conservation laws in the curved axisymmetric geometry of the current sheath

Direct measurement of axial magnetic field in the PF-1000 dense plasma focus (DPF), and its reported correlation with neutron emission, call for a fresh look at previous reports of existence of axial magnetic field component in the DPF from other laboratories, and associated data suggesting toroidal directionality of fast ions participating in fusion reactions, with a view to understand the underlying physics. In this context, recent work dealing with application of the hyperbolic conservation law formalism to the DPF is extended in this paper to a curvilinear coordinate system, which reflects the shape of the DPF current sheath. Locally unidirectional shock propagation in this coordinate system enables construction of a system of 7 one-dimensional hyperbolic conservation law equations with geometric source terms, taking into account all the components of magnetic field and flow velocity. Rankine-Hugoniot jump conditions for this system lead to expressions for the axial magnetic field and three components of fluid velocity having high ion kinetic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Damages of Carbon-Tungsten Samples under Influence of Deuterium Ions and Dense Plasma Streams within Plasma-Focus Facility

The paper reports on experimental studies of processes of the interaction of pulsed streams of fast deuterium ions (E{sub i}{approx}100 keV) and dense deuterium plasma (v{sub pl}>10{sup 7} cm/s) with samples made of carbon and tungsten. Experiments were performed in the large PF-1000 plasma-focus facility with the charging energy of 481 kJ and with the pure deuterium filling. Power flux density of plasma/ions streams was q = 10{sup 7}-10{sup 10} W/cm{sup 2} and the pulse length was from 10{sup -7} s to 10{sup -6} s, whereas the duration of heat pulses (due to a secondary plasma at the target's surface) was 10{sup -4} s. The stainless steel, tungsten and carbon-tungsten samples were placed in the zone of their strong melting and evaporation or in the zone without their melting. Each sample was exposed to 1 through 10 discharges, and the irradiated samples were investigated with optical-, electron- and atomic-force-microscopes. The interaction of intense plasma-ion pulses with the carbon-tungsten samples caused the formation of a wave-like relief on sample surfaces, the evident erosion of the sample material, and the creation of numerous micro-cracks. It was also found that about 200-nm-thick layer of the irradiated tungsten sample contained many melted fragments of nm-dimensions. The results might be useful for estimations of tungsten behavior in extreme situations (e.g. disruptions) expected in fusion reactors with magnetic plasma confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dense plasma focus (DPF) accelerated non radio isotopic radiological source

A non-radio-isotopic radiological source using a dense plasma focus (DPF) to produce an intense z-pinch plasma from a gas, such as helium, and which accelerates charged particles, such as generated from the gas or injected from an external source, into a target positioned along an acceleration axis and of a type known to emit ionizing radiation when impinged by the type of accelerated charged particles. In a preferred embodiment, helium gas is used to produce a DPF-accelerated He2+ ion beam to a beryllium target, to produce neutron emission having a similar energy spectrum as a radio-isotopic AmBe neutron source. Furthermore, multiple DPFs may be stacked to provide staged acceleration of charged particles for enhancing energy, tunability, and control of the source.

07 ISOTOPE AND RADIATION SOURCES↗

Tailoring a plasma focus as hard x-ray source for imaging

An investigation on temporal and spatial properties of hard x-rays (15-88 keV) emitted in a 5.3 kJ plasma focus using Si pin diodes and a pinhole camera is reported. The maximum yield of hard x-rays of 15-88 keV range is estimated about 4.7 J and corresponding efficiency for x-ray generation is 0.09%. The x-rays with energy >15 keV have 15-20 ns pulse duration and approx1 mm source size. This radiation is used for contact x-ray imaging of biological and compound objects and spatial resolution of approx50 mum is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Spectroscopy of a Mega-Ampere Dense Plasma Focus

Exhibit describes an optical streaked spectroscopy system that was developed to evaluate the spectral emission of the run-down, run-in, and pinch phases on the Gemini Dense Plasma Focus. Time-resolved emission spectra were captured for Hydrogen, Deuterium, Krypton, and Argon gases from these phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗