At least 163 records · Page 9

Mulan: a part-per-million measurement of the muon lifetime and determination of the Fermi constant

The part-per-million measurement of the positive muon lifetime and determination of the Fermi constant by the MuLan experiment at the Paul Scherrer Institute is reviewed. The experiment used an innovative, time-structured, surface muon beam and a near-4 \pi π , finely-segmented, plastic scintillator positron detector. Two in-vacuum muon stopping targets were used: a ferromagnetic foil with a large internal magnetic field, and a quartz crystal in a moderate external magnetic field. The experiment acquired a dataset of 1.6 \times 10^{12} 1.6 × 10 12 positive muon decays and obtained a muon lifetime \tau_{\mu} = 2\, 196\, 980.3(2.2) τ μ = 2 196 980.3 ( 2.2 ) ~ps (1.0~ppm) and Fermi constant G _F = 1.166\, 378\, 7(6) \times 10^{-5} F = 1.166 378 7 ( 6 ) × 10 − 5 GeV ^{-2} − 2 (0.5~ppm). The thirty-fold improvement in \tau_{\mu} τ μ has proven valuable for precision measurements in nuclear muon capture and the commensurate improvement in G _F F has proven valuable for precision tests of the standard model.

Carey, Rebecca↗

Tests of Scintillator+WLS Strips for Muon System at Future Colliders

Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~ 7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of the Effort to Use Active-induced Time Correlation Techniques to Measure the Enrichment of HEU

This document summarizes the effort to use active-induced time correlation techniques to measure the enrichment of bulk quantities of enriched uranium. In summary, these techniques use an external source to initiate fission chains, and the time distribution of the detected fission chain neutrons is sensitive to the fissile material enrichment. The number of neutrons emitted from a chain is driven by the multiplication of the item, and the enrichment is closely coupled to the multiplication of the item. As the enrichment increases (decreases), the multiplication increases (decreases) if the geometry is held constant. The time distribution of fission chain neutrons is a complex function of the enrichment and material configuration. The enrichment contributes to the probability of a subsequent fission in a chain via the likelihood of fissioning on an even-numbered isotope versus an odd-numbered isotope. The material configuration contributes to the same probability via solid angle effects for neutrons inducing subsequent fissions and the presence of any moderating material. To simplify the ability to accurately measure the enrichment, an associated particle imaging (API) D-T neutron generator and an array of plastic scintillators are used to simultaneously image the item and detect the fission chain neutrons. The image is used to significantly limit the space of enrichment and material configuration and enable the enrichment to be determined unambiguously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmic Ray Nuclei (CRN) detector investigation

The Cosmic Ray Nuclei (CRN) detector was designed to measure elemental composition and energy spectra of cosmic radiation nuclei ranging from lithium to iron. CRN was flown as part of Spacelab 2 in 1985, and consisted of three basic components: a gas Cerenkov counter, a transition radiation detector, and plastic scintillators. The results of the experiment indicate that the relative abundance of elements in this range, traveling at near relativistic velocities, is similar to those reported at lower energy.

Meyer, Peter↗

All-Particle Spectrum Measured by the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC), a balloon-borne experiment, is designed to investigate the composition and energy spectra of cosmic rays of charge Z = 1 to 26 over the energy range - 10(exp 11) - 10(exp 14) ev. The instrument consists of a silicon matrix charge detector, plastic-scintillator strip hodoscopes interleaved with graphite interaction targets, and an 18 radiation length deep, fully active bismuth germanate (BGO) calorimeter. ATIC has had two successful long duration balloon (LDB) flights launched from McMurdo Station, Antarc't'ica in 2000 and 2002. In this paper, we present the all-particle spectrum extracted from data collected during the ATIC flights, and compare it with results from other experiments at both lower and higher energies.

Ahn, H. S.↗

Novel Nuclear Reactions Observed in Bremsstrahlung-Irradiated Deuterated Metals

d-D nuclear fusion events were observed in an electronscreened, deuterated metal lattice by reacting cold deuterons with hot deuterons (d*) produced by elastically scattered neutrons originating from bremsstrahlung photodissociation (where “d” and “D” denote 2H). Exposure of deuterated materials (ErD3 and TiD2) to photon energies in the range of 2.5 to 2.9 MeV resulted in photodissociation neutrons that were below 400 keV and also the 2.45-MeV neutrons, consistent with 2H(d, n)3He fusion. Additionally, neutron energies of approximately 4 and 5 MeV for TiD2 and ErD3 were measured, consistent with either boosted neutrons from kinetically heated deuterons or Oppenheimer-Phillips stripping reactions in the highly screened environment. Neutron spectroscopy was conducted using calibrated lead shielded liquid (EJ-309) and plastic (stilbene) scintillator detectors. The data support the theoretical analysis in a companion paper, predicting fusion reactions and subsequent reactions in the highly screened environment.

Bruce M Steinetz↗

SU-E-CAMPUS-T-03: Four-Dimensional Dose Distribution Measurement Using Plastic Scintillator

Purpose: To develop the detector for the four-dimensional dose distribution measurement. Methods: We made the prototype detector for four-dimensional dose distribution measurement using a cylindrical plastic scintillator (5 cm diameter) and a conical reflection grass. The plastic scintillator is used as a phantom. When the plastic scintillator is irradiated, the scintillation light was emitted according to absorbed dose distribution. The conical reflection grass was arranged to surround the plastic scintillator, which project to downstream the projection images of the scintillation light. Then, the projection image was reflected to 45 degree direction by flat reflection grass, and was recorded by camcorder. By reconstructing the three-dimensional dose distribution from the projection image recorded in each frame, we could obtain the four-dimensional dose distribution. First, we tested the characteristic according to the amount of emitted light. Then we compared of the light profile and the dose profile calculated with the radiotherapy treatment planning system. Results: The dose dependency of the amount of light showed linearity. The pixel detecting smaller amount of light had high sensitivity than the pixel detecting larger amount of light. However the difference of the sensitivity could be corrected from the amount of light detected in each pixel. Both of the depth light profile through the conical reflection grass and the depth dose profile showed the same attenuation in the region deeper than peak depth. In lateral direction, the difference of the both profiles was shown at outside field and penumbra region. We consider that the difference is occurred due to the scatter of the scintillation light in the plastic scintillator block. Conclusion: It was possible to obtain the amount of light corresponding to the absorbed dose distribution from the prototype detector. Four-dimensional dose distributions can be reconstructed with high accuracy by the correction of the scattered light.

07 ISOTOPE AND RADIATION SOURCES↗

Qualification study of SiPMs on a large scale for the CMVD Experiment

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel method for modeling the neutron time of flight (nTOF) detector response in current mode to inertial confinement fusion experiments.

There are several machines in this country that produce short bursts of neutrons for various applications. A few examples are the Z machine, operated by Sandia National Laboratories in Albuquerque, NM ; the OMEGA Laser Facility at the University of Rochester in Rochester, NY ; and the National Ignition Facility (NIF) operated by the Department of Energy at Lawrence Livermore National Laboratory in Livermore, California . They all incorporate neutron time of flight (nTOF) detectors which measure neutron yield, and the shapes of the waveforms from these detectors contain germane information about the plasma conditions that produce the neutrons. However, the signals can also be %E2%80%9Cclouded%E2%80%9D by a certain fraction of neutrons that scatter off structural components and also arrive at the detectors, thereby making analysis of the plasma conditions more difficult. These detectors operate in current mode - i.e., they have no discrimination, and all the photomultiplier anode charges are integrated rather than counted individually as they are in single event counting. Up to now, there has not been a method for modeling an nTOF detector operating in current mode. MCNP PoliMi was developed in 2002 to simulate neutron and gamma ray detection in a plastic scintillator, which produces a collision data output table about each neutron and photon interaction occurring within the scintillator; however, the post processing code which accompanies MCNP PoliMi assumes a detector operating in single event counting mode and not current mode. Therefore, the idea for this work had been born: could a new post processing code be written to simulate an nTOF detector operating in current mode? And if so, could this process be used to address such issues as the impact of neutron scattering on the primary signal? Also, could it possibly even identify sources of scattering (i.e., structural materials) that could be removed or modified to produce %E2%80%9Ccleaner%E2%80%9D neutron signals? This process was first developed and then applied to the axial neutron time of flight detectors at the Z Facility mentioned above. First, MCNP PoliMi was used to model relevant portions of the facility between the source and the detector locations. To obtain useful statistics, variance reduction was utilized. Then, the resulting collision output table produced by MCNP PoliMi was further analyzed by a MATLAB postprocessing code. This converted the energy deposited by neutron and photon interactions in the plastic scintillator (i.e., nTOF detector) into light output, in units of MeVee%D1%84 (electron equivalent) vs time. The time response of the detector was then folded into the signal via another MATLAB code. The simulated response was then compared with experimental data and shown to be in good agreement. To address the issue of neutron scattering, an %E2%80%9CIdeal Case,%E2%80%9D (i.e., a plastic scintillator was placed at the same distance from the source for each detector location) with no structural components in the problem. This was done to produce as %E2%80%9Cpure%E2%80%9D a neutron signal as possible. The simulated waveform from this %E2%80%9CIdeal Case%E2%80%9D was then compared with the simulated data from the %E2%80%9CFull Scale%E2%80%9D geometry (i.e., the detector at the same location, but with all the structural materials now included). The %E2%80%9CIdeal Case%E2%80%9D was subtracted from the %E2%80%9CFull Scale%E2%80%9D geometry case, and this was determined to be the contribution due to scattering. The time response was deconvolved out of the empirical data, and the contribution due to scattering was then subtracted out of it. A transformation was then made from dN/dt to dN/dE to obtain neutron spectra at two different detector locations.

Nelson, Alan J.↗

Capture-gated Spectroscopic Measurements of Monoenergetic Neutrons with a Composite Scintillation Detector

Abstract—We report on the measurements of Monoenergetic neutrons from DD and DT fusion reactions by use of the capture gating method in a heterogeneous plastic-glass composite scintillation detector. The cylindrical detector is 5.08 cm in diameter and 5.05 cm in height and was fabricated using 1-mm diameter Li-doped glass rods(GS20) and scintillating polyvinyl toluene (EJ-290). Different scintillation decay constants are used to identify energy depositions in two materials constituting the composite scintillator. Geant4 simulations of the neutron thermalization and capture process were conducted, finding a mean capture time of approximately 2.6 ms for both DD and DT neutrons. A capture gating time acceptance window based on simulation results was used to identify the neutron thermalization pulses. The total scintillation light yield produced in neutron thermalization was measured and found to show consistency on event-by-event basis despite the variety of neutron thermalization histories prior to capture. The ratio of light yields from thermalization of 14.1 MeV and 2.45 MeV neutrons in the EJ-290 scintillator was determined to be 14.6, and the light output from 2.45 MeV neutrons was also correlated to its electron equivalent, obtaining a value of 0.58*0.05 MeVee.

47 OTHER INSTRUMENTATION↗

The Escaramujo Project: Instrumentation Courses During a Road Trip Across the Americas

The Escaramujo Project was a series of eight hands-on laboratory courses on High Energy Physics and Astroparticle Instrumentation, in Latinamerican Institutions. The Physicist Federico Izraelevitch traveled on a van with his wife and dogs from Chicago to Buenos Aires teaching the courses. The sessions took place at Institutions in Mexico, Guatemala, Costa Rica, Colombia, Ecuador, Peru and Bolivia at an advanced undergraduate and graduate level. During these workshops, each group built a modern cosmic ray detector based on plastic scintillator and silicon photomultipliers, designed specifically for this project. After the courses, a functional detector remained at each institution to be used by the faculty to facilitate the training of future students and to support and enable local research activities. The five-days workshops covered topics such as elementary particle and cosmic ray Physics, radiation detection and instrumentation, low-level light sensing with solid state devices, front-end analog electronics and object-oriented data analysis (C++ and ROOT). Throughout this initiative, about a hundred of talented and highly motivated young students were reached. With the detector as a common thread, they were able to understand the designing principles and the underlying Physics involved in it, build the device, start it up, characterize it, take data and analyze it, mimicking the stages of a real elementary particle Physics experiment. Besides the aims to awaken vocations in science, technology and engineering, The Escaramujo Project was an effort to strengthen the integration of Latinamerican academic institutions into the international scientific community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smaller, Lower-Power Fast-Neutron Scintillation Detectors

Scintillation-based fast-neutron detectors that are smaller and less power-hungry than mainstream scintillation-based fast-neutron detectors are undergoing development. There are numerous applications for such detectors in monitoring fast-neutron fluxes from nuclear reactors, nuclear materials, and natural sources, both on Earth and in outer space. A particularly important terrestrial application for small, low-power, portable fast-neutron detectors lies in the requirement to scan for nuclear materials in cargo and baggage arriving at international transportation facilities. The present development of miniature, low-power scintillation-based fast-neutron detectors exploits recent advances in the fabrication of avalanche photodiodes (APDs). Basically, such a detector includes a plastic scintillator, typically between 300 and 400 m thick with very thin silver mirror coating on all its faces except the one bonded to an APD. All photons generated from scintillation are thus internally reflected and eventually directed to the APD. This design affords not only compactness but also tight optical coupling for utilization of a relatively large proportion of the scintillation light. The combination of this tight coupling and the avalanche-multiplication gain (typically between 750 and 1,000) of the APD is expected to have enough sensitivity to enable monitoring of a fast-neutron flux as small as 1,000 cm(exp -2)s(exp -1). Moreover, pulse-height analysis can be expected to provide information on the kinetic energies of incident neutrons. It has been estimated that a complete, fully developed fast-neutron detector of this type, would be characterized by linear dimensions of the order of 10 cm or less, a mass of no more than about 0.5 kg, and a power demand of no more than a few watts.

Patel, Jagdish↗

A high efficiency veto to increase the sensitivity of ZEPLIN-III, a WIMP detector

An active veto detector to complement the ZEPLIN-III two phase Xenon, direct dark matter device is described. The proposed design consists of 52 plastic scintillator segments, individually read out by high efficiency photomultipliers, coupled to a Gd loaded passive polypropylene shield. Experimental work was performed to determine the plastic scintillator characteristics which were used to inform a complete end-to-end Monte Carlo simulation of the expected performance of the new instrument, both operating alone and as an active veto detector for ZEPLIN-III. The veto device will be capable of tagging over 65% of coincident nuclear recoil events in the energy range of interest in ZEPLIN-III, and over 12% for gamma ray rejection, while contributing no significant additional background. In addition it will also provide valuable diagnostic capabilities. The inclusion of the veto to ZEPLIN-III will aid to significantly improve the sensitivity to spin independent WIMP-nucleon cross sections below 10{sup -8} pb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Scintillation detector for carbon-14

Detector consists of plastic, cylindrical double-wall scintillation cell, which is filled with gas to be analyzed. Thin, inner cell wall is isolated optically from outer (guard) scintillator wall by evaporated-aluminum coating. Bonding technique provides mechanical support to cell wall when device is exposed to high temperatures.

Knoll, G. F.↗

A Geant Study of the Scintillating Optical Fiber (SOFCAL) Cosmic Ray Detector

Recent energy measurements by balloon-borne passive emulsion chambers indicate that the flux ratios of protons to helium nuclei and of protons to all heavy nuclei decrease as the primary cosmic ray energy per nucleon increases above approx. 200 GeV/n, and suggest a "break" in the proton spectrum between 200 GeV and 5 TeV. However, these passive emulsion chambers are limited to a lower energy threshold of approx. 5 TeV/n, and cannot fully explore this energy regime. Because cosmic ray flux and composition details may be significant to acceleration models, a hybrid detector system called the Scintillating Optical Fiber Calorimeter (SOFCAL) has been designed and flown. SOFCAL incorporates both conventional passive emulsion chambers and an active calorimeter utilizing scintillating plastic fibers as detectors. These complementary types of detectors allow the balloon-borne SOFCAL experiment to measure the proton and helium spectra from approx. 400 GeV/n to approx. 20 TeV. The fundamental purpose of this study is to use the GEANT simulation package to model the hadronic and electromagnetic shower evolution of cosmic rays incident on the SOFCAL detector. This allows the interpretation of SOFCAL data in terms of charges and primary energies of cosmic rays, thus allowing the determinations of cosmic ray flux and composition as functions of primary energy.

Munroe, Ray B., Jr.↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 12: Suitability of plan class specific reference fields for estimating dosimeter correction factors for small clinical CyberKnife fields

Purpose: The purpose of this work is to investigate the utility of plan class specific reference (PCSR) fields for predicting dosimeter response within isocentric and non-isocentric composite clinical fields using the smallest fields employed by the CyberKnife radiosurgery system. Methods: Monte Carlo dosimeter response correction factors (CFs) were calculated for a plastic scintillator and microchamber dosimeter in 21 clinical fields and 9 candidate plan-class PCSR fields which employ the 5, 7.5 and 10 mm diameter collimators. Measurements were performed in 5 PCSR fields to confirm the predicted relative response of detectors in the same field. Results: Ratios of corrected measured dose in the PCSR fields agree to within 1% of unity. Calculated CFs for isocentric fields agree within 1.5% of those for PCSR fields. Large and variable microchamber CFs are required for non-isocentric fields, with differences as high as 5% between different clinical fields in the same plan class and 4% within the same field depending on the point of measurement. Non-isocentric PCSR fields constructed to have relatively homogenous dose over a region larger than the detector have very different ion chamber CFs from clinical fields. The plastic scintillator detector has much more consistent response within each plan class but still require 3–4% corrections in some fields. Conclusions: While the PCSR field concept is useful for small isocentric fields, this approach may not be appropriate for non-isocentric clinical fields which exhibit large and variable ion chamber CFs which differ significantly from CFs for homogenous field PCSRs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing of the KRI-developed Silicon PIN Radioxenon Detector

Radioxenon detectors are used for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) in a network of detectors throughout the world called the International Monitoring System (IMS). The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS) has tasked Pacific Northwest National Laboratory (PNNL) with testing a V.G. Khlopin Radium Institute (KRI) and Lares Ltd-developed Silicon PIN detector for radioxenon detection. PNNL measured radioxenon with the silicon PIN detector and determined its potential compared to current plastic scintillator beta cells. While the PNNL tested Si detector experienced noise issues, a second detector was tested in Russia at Lares Ltd, which did not exhibit the noise issues. Without the noise issues, the Si detector produces much better energy resolution and isomer peak separation than a conventional plastic scintillator cell used in the SAUNA systems in the IMS. Under the assumption of 1 cm 3 of Xe in laboratory-like conditions, 24-hr count time (12-hr count time for the SAUNA), with the respective shielding the minimum detectable concentrations for the Si detector tested by Lares Ltd (and a conventional SAUNA system) were calculated to be: 131m Xe – 0.12 mBq/m 3 (0.12 mBq/m 3 ); 133 Xe – 0.18 mBq/m 3 (0.21 mBq/m 3 ); 133m Xe – 0.07 mBq/m 3 (0.15 mBq/m 3 ); 135 Xe – 0.45 mBq/m 3 (0.67 mBq/m 3 ). Detection limits, which are one of the important factors in choosing the best detection technique for radioxenon in field conditions, are significantly better than for SAUNA-like detection systems for 131m Xe and 133m Xe, but similar for 133 Xe and 135 Xe. Another important factor is the amount of “memory effect” or carry over signal from one radioxenon measurement to the subsequent sample. The memory effect is reduced by a factor of 10 in the Si PIN detector compared to the current plastic scintillator cells. There is potential for further reduction with the removal of plastics within the cell, which will need to be explored in future work. A third important parameter in choosing the best detection technique for radioxenon is the resolution of the electron detection. While the resolution is important in determining the minimum detectable concentration, it plays a larger role in source identification when there is a visible signal. The Silicon PIN diodes generated improved resolution over a similar plastic scintillator cell. With the improved resolution, it becomes easier to distinguish the radioxenon isomers ( 133m Xe and 131m Xe) from the 133 Xe beta continuum background. With the beta background from 133 Xe ever present with the detection of the isomers, the improved resolution proves vital in calculating the ratios of the three isotopes. With an accurate measurement of the isotopic ratios, the anthropogenic sources of radioxenon (medical isotope production and nuclear reactors) can be more accurately distinguished. Based on the results shown within this report, a Si PIN beta cell shows the potential to aid in the operation and discriminating power of the IMS for the CTBTO. However, there are a number of issues that need attention before a detector of this design would be reliable enough for field operations in the IMS. Issues that need develop include, but are not limited to: studying the robustness of the design in field conditions, eliminating or minimizing the noise and variability of individual Si detector elements, understanding the long-term gain stability of the Si detectors, and reducing the non-Si materials within the cell (i.e. the plastic housing).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗