Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

2195 Aluminum-Copper-Lithium Friction Plug Welding Development

Technology developments and applications of friction plug welding is presented. This friction repair welding technology is being studied for implementation on the Space Transportation System's Super Light Weight External Tank. Single plug repairs will be used on a vast majority of weld defects, however, linear defects of up to several inches can be repaired by overlapping plug welds. Methods and results of tensile, bend, simulated service, surface crack tension and other tests at room and cryogenic temperatures is discussed. Attempts to implement Friction Plug Welding has led to both tool and process changes in an attempt to minimize expansive tooling and lengthy implementation times. Process control equipment and data storage methods intended for large scale production will also be addressed. Benefits include increased strength and toughness, decreased weld repair time, automated and highly reliable process, and a lower probability of having to re-repair defect locations.

Takeshita, Rike P.↗

Friction Plug Weld Repair Geometric Innovations

A viewgraph presentation outlines the fundamentals of friction plug welding. A process overview is given for friction push plug welding, including different uses and strengths of push plug welding. Details are given for friction pull plug welding, including welding parameters, details on observed defects, expected benefits, and test results.

Coletta, Edmond R.↗

Elimination of toxicity from polyurethane foam plugs used for plant culture

Polyurethane foam plugs commonly are used as collars or supports to grow plants in solution culture. Despite their utility, these foam plugs can be quite toxic to plants, particularly to small seedlings. We have observed tissue injury in tests using plugs to support lettuce, red beet, and potato plants in solution culture. Typically, the injury is initiated on the hypocotyl or stem tissue in direct contact with the foam, and appears within 30 hr as a brownish discoloration on the tissue surface. This discoloration can be followed by complete collapse of affected tissue and eventual death of the seedling. When injury does not progress beyond surface browning, the seedling survives but growth is slowed. In this paper, we report on different treatments that can be used to remove the toxicity of these plugs so they can be used in plant research.

Non-NASA Center↗

SpaceWire Plug and Play

The ability to rapidly deploy inexpensive satellites to meet tactical goals has become an important goal for military space systems. In fact, Operationally Responsive Space (ORS) has been in the spotlight at the highest levels. The Office of the Secretary of Defense (OSD) has identified that the critical next step is developing the bus standards and modular interfaces. Historically, satellite components have been constructed based on bus standards and standardized interfaces. However, this has not been done to a degree, which would allow the rapid deployment of a satellite. Advancements in plug-and-play (PnP) technologies for terrestrial applications can serve as a baseline model for a PnP approach for satellite applications. Since SpaceWire (SpW) has become a de facto standard for satellite high-speed (greater than 200Mbp) on-board communications, it has become important for SpW to adapt to this Plug and Play (PnP) environment. Because SpW is simply a bulk transport protocol and lacks built-in PnP features, several changes are required to facilitate PnP with SpW. The first is for Host(s) to figure out what the network looks like, i.e., how pieces of the network, routers and nodes, are connected together; network mapping, and to receive notice of changes to the network. The second is for the components connected to the network to be understood so that they can communicate. The first element, network topology mapping & change of status indication, is being defined (topic of this paper). The second element describing how components are to communicate has been defined by ARFL with the electronic data sheets known as XTEDS. The first element, network mapping, is recent activities performed by Air Force Research Lab (ARFL), Naval Research Lab (NRL), NASA and US industry (Honeywell, Clearwater, FL, and others). This work has resulted in the development of a protocol that will perform the lower level functions of network mapping and Change Of Status (COS) indication required by Plug 'n' Play over SpaceWire. This work will be presented to the SpaceWire working group for standardization under European Cooperation for Space Standardization (ECSS) and to obtain a permanent Protocol ID (see SpaceWire Protocol ID: What Does it Mean to You; IEEE Aerospace Conference 2006). The portion of the Plug 'n' Play protocol that will be described in this paper is how the Host(s) of a SpaceWire network map the network and detect additions and deletions of devices on a SpaceWire network.

Rakow, Glenn↗

Friction plug welding

Friction plug welding (FPW) usage is advantageous for friction stir welding (FSW) hole close-outs and weld repairs in 2195 Al--Cu--Li fusion or friction stir welds. Current fusion welding methods of Al--Cu--Li have produced welds containing varied defects. These areas are found by non-destructive examination both after welding and after proof testing. Current techniques for repairing typically small (<0.25) defects weaken the weldment, rely heavily on welders' skill, and are costly. Friction plug welding repairs increase strength, ductility and resistance to cracking over initial weld quality, without requiring much time or operator skill. Friction plug welding while pulling the plug is advantageous because all hardware for performing the weld can be placed on one side of the workpiece.

Takeshita, Riki↗

NaK Plugging Meter Design for the Feasibility Test Loops

The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

Pearson, J. Boise↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction, supersonic, jet noise↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction↗

Flow, Noise and Thrust of Supersonic Plug Nozzles

Nozzles with internal mixers and external plugs are candidates for supersonic aircraft concepts. A fundamental experimental investigation is being conducted at NASA Glenn Research Center (GRC) to assess the optimum performance of external plugs. The focus is on noise reduction potential during landing and takeoff (LTO) operation of the aircraft while maintaining optimum thrust performance. Earlier results on flow field and noise of plug nozzles were presented in the 2022 AIAA Aeroacoustics Meeting [1]; see also [2] for a review of the plug nozzle literature.

Jets↗

Laser spark plug numerical design process with experimental validation

This work reports the numerical modeling design procedure for a miniaturized laser spark plug. In previous work both side pumped and end pumped laser spark plugs were empirically designed and tested. Experimental data from the previous laser spark plug development cycles is compared to the output predicted by a known set of rate equations. The rate equations are used to develop interrelated inter cavity time dependent waveforms that are then used to identify key variables. These variables are then input to a set of secondary equations for determining the output pulse energy, output power, and output pulse width of the simulated laser system. The physical meaning and the operation of the rate equations is explained in detail. This paper concentrates on the process and decision points needed to successfully design a solid state passively Q-switched laser system, either side pumped or end pumped, that produces the appropriate output needed for use as a laser spark plug for internal combustion engines.

58 GEOSCIENCES↗

Laser spark plug numerical design process with experimental validation

This work reports the numerical modeling design procedure for a miniaturized laser spark plug. In previous work both side pumped and end pumped laser spark plugs were empirically designed and tested. Experimental data from the previous laser spark plug development cycles is compared to the output predicted by a known set of rate equations. The rate equations are used to develop interrelated inter cavity time dependent waveforms that are then used to identify key variables. These variables are then input to a set of secondary equations for determining the output pulse energy, output power, and output pulse width of the simulated laser system. The physical meaning and the operation of the rate equations is explained in detail. This paper concentrates on the process and decision points needed to successfully design a solid state passively Q-switched laser system, either side pumped or end pumped, that produces the appropriate output needed for use as a laser spark plug for internal combustion engines.

33 ADVANCED PROPULSION SYSTEMS↗

System and method for charging a plug-in electric vehicle

A charging system and method that may be used to automatically apply customized charging settings to a plug-in electric vehicle, where application of the settings is based on the vehicle's location. According to an exemplary embodiment, a user may establish and save a separate charging profile with certain customized charging settings for each geographic location where they plan to charge their plug-in electric vehicle. Whenever the plug-in electric vehicle enters a new geographic area, the charging method may automatically apply the charging profile that corresponds to that area. Thus, the user does not have to manually change or manipulate the charging settings every time they charge the plug-in electric vehicle in a new location.

33 ADVANCED PROPULSION SYSTEMS↗

Plug load management system with load identification

The present disclosure relates to a plug load management system having automatic and dynamic load detection, meaning it has the ability to identify devices that are plugged into outlets of a building and determine the location of the plug load down to the specific outlet. When a device is moved, the plug load management system can determine this change and update accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selecting a Control Strategy for Plug and Process Loads

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Outlets: Wireless Meter and Control Systems for Plug and Process Loads

Smart outlets control the flow of power to devices plugged into them and measure their energy use. The energy use data can be accessed via an online dashboard or smartphone application, allowing the user to turn power to plug-in devices on or off based on a schedule established in the dashboard or application. This four-page resource is a fact sheet meant to educate commercial building owners on smart outlets: what they are, why we use them, and how to use them in a way that will achieve energy savings while maintaining occupant comfort. The resource also describe how to procure a smart outlet system and how to fully capture their benefits over time. This resource was developed to support the Better Buildings Alliance Plug and Process Loads Technology Research Team.

30 DIRECT ENERGY CONVERSION↗

Categorizing Plug Load Solutions by Ease of Implementation

Plug loads account for a growing share of U.S. commercial building electricity use, projected to rise from 16% today to 21% by 2050. Managing these loads presents a substantial opportunity for reducing energy costs while providing additional operational benefits, such as improved asset management and occupant comfort. Despite their potential, plug loads are numerous, diverse, and highly occupant-dependent, making control challenging. This publication organizes plug load control strategies by level of effort, offering building owners and operators a staged approach to implement interventions ranging from smart outlets and automatic receptacle controls to behavioral strategies. By following these actionable steps, building stakeholders can reduce energy consumption, lower utility bills, and realize broader operational advantages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determining PHEV Performance Potential – User and Environmental Influences on A123 Systems’ Hymotion™ Plug-In Conversion Module for the Toyota Prius

A123Systems’s HymotionTM L5 Plug-in Conversion Module (PCM) is a supplemental battery system that converts the Toyota Prius hybrid electric vehicle (HEV) into a plug-in hybrid electric vehicle (PHEV). The Hymotion system uses a lithium ion battery pack with 4.5 kWh of useable energy capacity and recharges by plugging into a standard 110/120V outlet. The system is designed to more than double the Prius fuel efficiency for 30-50km of charge depleting range. This paper will cover efforts by A123 Systems and the Idaho National Laboratory in studying the on-road performance of this PHEV fleet. The performance potentials of various fleets will be compared in order to determine the major influences on overall performance.

33 ADVANCED PROPULSION SYSTEMS↗

Pressure drop of two-phase dry-plug flow in round mini-channels: Effect of moving contact line

In the present experimental study, the pressure drop of the two-phase dry-plug flow (dry wall condition at the gas portions) in round mini-channels was investigated. The air-water mixtures were flowed through the round mini-channels made of polyurethane and Teflon, respectively, with their inner diameters ranging from 1.62 to 2.16 mm. In the dry-plug flow regime, the pressure drop measured became larger either by increasing the liquid superficial velocity or by decreasing the gas superficial velocity due to the increase of the number of the moving contact lines in the test section. In such a case, the role of the moving contact lines turned out to be significant. Therefore, a pressure drop model of dry-plug flow was proposed through modification of the dynamic contact angle analysis taking account of the energy dissipation by the moving contact lines, which represents the experimental data within the mean deviation of 4%. (author)

42 ENGINEERING↗