Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Wind-Wildlife Impacts Literature Database (WILD)(Fact Sheet)

The Wind-Wildlife Impacts Literature Database (WILD), developed and maintained by the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL), is comprised of over 1,000 citations pertaining to the effects of land-based wind, offshore wind, marine and hydrokinetic, power lines, and communication and television towers on wildlife.

17 WIND ENERGY↗

QUANTIFICATION OF FUNCTIONAL IMPACT CLASSIFICATION ON THE CURRENT US NUCLEAR FLEET

Many plants experience multiple failure events each year, and while none of these events result in core damage further consideration for nuclear power plant (NPP) type and its role in an event needs to be considered. Specifically herein initiating events (IE) are considered these are unplanned events that occur while a nuclear plant is in critical operation, and requires that the plant be shut down to achieve a stable state. Breaking IE failure events into groups results in the classification of functional impact (FI) groups. A FI group is a risk-significant event category that could impact the ability of a NPP to remove decay heat from the reactor. For an event to be considered a FI, it must be associated with a manual or automatic reactor trip, irrespective of the order of events. In addition, the plant must be at or above the point of adding heat and the event must happen before or shortly after a reactor trip. One or more FIs may be identified in any individual reactor trip sequence. An example of a FIs is the loss of offsite power (LOOP) from a bird interaction with the power lines. This results in a failure to transfer power to an emergency source, such as a generator, producing a turbine and reactor trip and then a closure of main steam isolation valves (MSIVS). The FI applicable to this reactor trip sequence would be loss of offsite power and closure of at least one MSIV in each main steam line. The results presented are focused on the analysis and evaluation of FI event categories that can be found in IE studies [1], [2] and the Initialing Events Spreadsheet [3] and is a historical review of Licensee.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Geothermal Geodatabase for Wagon Wheel Hot Springs, Mineral County, Colorado

This geodatabase was built to cover several geothermal targets developed by Flint Geothermal in 2012 during a search for high-temperature systems that could be exploited for electric power development. Several of the thermal springs at Wagon Wheel Gap have geochemistry and geothermometry values indicative of high-temperature systems. Datasets include: 1. Results of reconnaissance shallow (2 meter) temperature surveys 2. Air photo lineaments 3. Groundwater geochemistry 4. Power lines 5. Georeferenced geologic map of Routt County 6. Various 1:24,000 scale topographic maps

15 GEOTHERMAL ENERGY↗

Is the Global MHD Modeling of the Magnetosphere Adequate for GIC Prediction: the May 27–28, 2017 Storm

Practical steps taken by the international community to reduce the damage to technological systems from space weather include the development of numerical models capable of real-time predictions of electromagnetic disturbances at the Earth’s surface. Here we examine the feasibility of a version of the Space Weather Modeling Framework (SWMF) global MHD simulation code similar to that used by the NOAA Space Weather Prediction Center to predict the level of geomagnetic field variability, and consequently geomagnetically induced currents (GICs). We consider the contribution of geomagnetic disturbances to the bursts of GIC in the electric power line of the Kola Peninsula during the May 27–28, 2017 storm and compare the observations with results of the global MHD model. During the maximal disturbance magnetic field variations at East Scandinavian stations become more irregular, as intense Pi3 pulsations are superposed on the magnetic bay. These pulsations are not quasi-sinusoidal waves like typical Pc5 pulsations, but they are rather a quasi-periodic sequence of magnetic impulses with time scales ~5–15 min. During this period with elevated Pi3 activity very high values of GIC were recorded (variations >100 A) in the electric power transmission line. The SWMF modeling reasonably well reproduces the global magnetospheric parameters, such as SYM-H index or cross-polar potential. However, the magnetic field variability dB/dt in the East Scandinavia predicted by the modeling has turned out to be more than order of magnitude less than that observed. Thus, the version of SWMF with the grid used by NOAA SWPC still cannot adequately predict for the May 27–28 event the fine structure of the storm/substorm—Pi3 geomagnetic disturbances, and consequently the magnitude of the GIC that they drive.

geomagnetically induced currents↗

Industrial PLC Network Modeling and Parameter Identification Using Sensitivity Analysis and Mean Field Variational Inference

A multiple input multiple output (MIMO) power line communication (PLC) model for industrial facilities was developed that uses the physics of a bottom-up model but can be calibrated like top-down models. The PLC model considers 4-conductor cables (three-phase conductors and a ground conductor) and has several load types, including motor loads. The model is calibrated to data using mean field variational inference with a sensitivity analysis to reduce the parameter space. The results show that the inference method can accurately identify many of the model parameters, and the model is accurate even when the network is modified.

47 OTHER INSTRUMENTATION↗

Particle-In-Cell/Monte Carlo Simulation of Ion Back BomBardment in a High Average Current RF Photo-Gun

In this paper, we report on study of ion back bombardment in a high average current radio-frequency (RF) photo-gun using a particle-in-cell/Monte Carlo simulation method. Using this method, we systematically studied effects of gas pressure, RF frequency, RF initial phase, electric field profile, magnetic field, laser repetition rate, different ion species on ion particle line density distribution, kinetic energy spectrum, and ion power line density distribution back bombardment onto the photocathode. Those simulation results suggested that effects of ion back bombardment could increase linearly with the background gas pressure and laser repetition rate. The RF frequency has significantly affected the ion motion inside the gun so that the ion power deposition on the photocathode in an RF gun can be several orders of magnitude lower than that in a DC gun. The ion back bombardment can be minimized by appropriately choosing the electric field profile and the initial phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Fast-Rise Transients in a Large-Power Transformer Winding

A high-altitude electromagnetic pulse (HEMP) may pose a significant threat to the electrical power grid. In this context, the present study considers here the potential impact of the HEMP early-time component (E1) on the winding of a typical transmission power line transformer. A time-domain, fully electromagnetic, three-dimensional, finite-element model was used to simulate the propagation of an E1-induced voltage surge into the transformer winding. The analysis is focused on the first few turns of the winding, the ones that are impacted by the largest electric field resulting from the applied pulse. The model follows the transient dynamics, while the pulse is traveling along the conductor, and the electric field is established across the insulation gaps through capacitive coupling. The simulations also considered the effect of an electrically floating, “shield” winding conductor. This is used as a countermeasure to improve the voltage uniformity across the winding during fast-rise transients. In this case, the propagation of the E1-induced pulse is compared with that from a slower rising, lightning standard waveform. The simulation results show that the presence of the shield conductor can effectively reduce the peak electric field between winding turns, in the presence of either E1 or lightning waveforms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispatchable Renewable Energy Model for Microgrid Power System

Over the years, many research projects have been performed and focused on finding out the effective ways to balance the power demands and supply on the utility grid. The causes of the imbalance could be the increasing demands from the end users, the loss of power generation (generators down), faults on the transmission lines, power tripped due to overload, and weather conditions, etc. An efficient Load Frequency Control (LFC) can assure the desired electricity quality provided to the residential, commercial and industrial end users. A simulation model is built in this project to investigate the contribution of the modeling of dispatchable energy such as solar energy, wind power, hydro power and energy storage to the balance of the microgrid power system. An analysis of simplified feedback control system with proportional, integral, and derivative (PID) controller was performed. The purpose of this research is to investigate a simulation model that achieves certain degree of the resilient control for the microgrid.

14 SOLAR ENERGY↗

Enabling DER Participation in Frequency Regulation Markets

Distributed energy resources (DERs) are playing an increasing role in ancillary services for the bulk grid, particularly in frequency regulation. In this article, we propose a framework for collections of DERs, combined to form microgrids and controlled by aggregators, to participate in frequency regulation markets. Our approach covers both the identification of bids for the market clearing stage and the mechanisms for the real-time allocation of the regulation signal. The proposed framework is hierarchical, consisting of a top layer and a bottom layer. The top layer consists of the aggregators communicating in a distributed fashion to optimally disaggregate the regulation signal requested by the system operator. The bottom layer consists of the DERs inside each microgrid whose power levels are adjusted so that the tie line power matches the output of the corresponding aggregator in the top layer. The coordination at the top layer requires the knowledge of cost functions, ramp rates, and capacity bounds of the aggregators. We develop meaningful abstractions for these quantities respecting the power flow constraints and taking into account the load uncertainties and propose a provably correct distributed algorithm for optimal disaggregation of regulation signals among the microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Political efficacy and familiarity as predictors of attitudes towards electric transmission lines in the United States

Public opposition to the construction (i.e., siting) of new high voltage overhead transmission lines is not a new or isolated phenomenon. Past research has posited a variety of reasons, applied general theories, and has provided empirical evidence to explain public opposition. The existing literature, while clarifying many elements of the issue, does not yet fully explain the complexities underlying this public opposition phenomenon. As a result, the current study demonstrated how two overlooked factors, people’s sense of political efficacy and their familiarity (i.e., prior exposure) with transmission lines, explained attitudes of support and opposition to siting new power lines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Line-Editor Computer Program

ZED editing program for DEC VAX computer simple, powerful line editor for text, program source code, and nonbinary data. Excels in processing of text by use of procedure files. Also features versatile search qualifiers, global changes, conditionals, online help, hexadecimal mode, space compression, looping, logical combinations of search strings, journaling, visible control characters, and automatic detabbing. Users of Cambridge implementation devised such ZED procedures as chess games, calculators, and programs for evaluating pi. Written entirely in C.

Scott, Peter J.↗

Revolutionary Aeropropulsion Concept for Sustainable Aviation: Turboelectric Distributed Propulsion

In response to growing aviation demands and concerns about the environment and energy usage, a team at NASA proposed and examined a revolutionary aeropropulsion concept, a turboelectric distributed propulsion system, which employs multiple electric motor-driven propulsors that are distributed on a large transport vehicle. The power to drive these electric propulsors is generated by separately located gas-turbine-driven electric generators on the airframe. This arrangement enables the use of many small-distributed propulsors, allowing a very high effective bypass ratio, while retaining the superior efficiency of large core engines, which are physically separated but connected to the propulsors through electric power lines. Because of the physical separation of propulsors from power generating devices, a new class of vehicles with unprecedented performance employing such revolutionary propulsion system is possible in vehicle design. One such vehicle currently being investigated by NASA is called the "N3-X" that uses a hybrid-wing-body for an airframe and superconducting generators, motors, and transmission lines for its propulsion system. On the N3-X these new degrees of design freedom are used (1) to place two large turboshaft engines driving generators in freestream conditions to minimize total pressure losses and (2) to embed a broad continuous array of 14 motor-driven fans on the upper surface of the aircraft near the trailing edge of the hybrid-wing-body airframe to maximize propulsive efficiency by ingesting thick airframe boundary layer flow. Through a system analysis in engine cycle and weight estimation, it was determined that the N3-X would be able to achieve a reduction of 70% or 72% (depending on the cooling system) in energy usage relative to the reference aircraft, a Boeing 777-200LR. Since the high-power electric system is used in its propulsion system, a study of the electric power distribution system was performed to identify critical dynamic and safety issues. This paper presents some of the features and issues associated with the turboelectric distributed propulsion system and summarizes the recent study results, including the high electric power distribution, in the analysis of the N3-X vehicle.

Kim, Hyun Dae↗

Supply voltage decoupling circuits for voltage droop mitigation

Circuits and methods are provided for utilizing decoupling capacitors to mitigate voltage droop on power supply lines of a power distribution network. A power supply line is capacitively decoupled using a first decoupling capacitor connected to the power supply line and charged to a first voltage level of the power supply line. A second decoupling capacitor is pre-charged to a second voltage level greater than the first voltage level and held in standby. A control circuit determines or predicts an occurrence of a droop event in which the first voltage decreases to a level which is at or below a droop threshold voltage level, and selectively connects the pre-charged second decoupling capacitor to the power supply line to source additional boosting current through discharging of the second decoupling capacitor and thereby capacitively decouple the power supply line using the higher second voltage and additional boosting current.

Zhang, Xin↗

OLED Luminaire with Panel Integrated Drivers and Advanced Controls

For this DOE award, Acuity Brands Lighting developed a novel OLED luminaire system featuring panel-integrated drivers at each individual OLED panel. The luminaire has a base station that receives user commands and performs AC/DC conversion. A power line communication (PLC) protocol is used to provide both power and digital control to each panel. A 66-panel CanvisTM luminaire using state-of-art OLED panels based on this system was successfully constructed. This is a first demonstration of such a luminaire architecture. It is also the first known implementation of this number of independently addressable nodes with a PLC protocol. This luminaire system architecture has added benefits in the flexibility of using multiple panel vendors for a given product, forward compatibility with future panels, and reduced luminaire wiring complexity and assembly time.

47 OTHER INSTRUMENTATION↗

Power Flow Controller for Renewables: Transformer-less Unified Power Flow Controller for Wind and Solar Power Transmission

GENI Project: MSU is developing a power flow controller to improve the routing of electricity from renewable sources through existing power lines. The fast, innovative, and lightweight circuitry that MSU is incorporating into its controller will eliminate the need for a separate heavy and expensive transformer, as well as the construction of new transmission lines. MSU’s controller is better suited to control power flows from distributed and intermittent wind and solar power systems than traditional transformer-based controllers are, so it will help to integrate more renewable energy into the grid. MSU‘s power flow controller can be installed anywhere in the existing grid to optimize energy transmission and help reduce transmission congestion.

ARPA-E↗

Technical and Economic Assessment of Solar Photovoltaic for Groundwater Extraction on the Hanford Site

The overall goal of environmental remediation is to protect human health and the environment. Implementing renewable energy sources such as solar photovoltaic (PV) in groundwater extraction and pump-and-treat (P&T) systems may help minimize the environmental footprint of remediation efforts. The first step in considering solar PV for powering Hanford groundwater extraction is assessing the technical and economic feasibility and identifying potential target locations where implementation would be most successful. Accordingly, a techno-economic assessment of solar PV for Hanford groundwater extraction was completed in FY15. Multiple solar PV alternatives ranging in size from 1.2 to 22.4 kWp DC were evaluated and compared against traditional grid-powered systems. Results indicate that the degree to which solar PV alternatives are feasible is primarily a function of the distance of avoided power cable costs and the inclusion of an energy storage component. Standalone solar PV systems provide an energy source at the well and avoid the costs and logistics associated with running long lengths of expensive power cable to the well-head. When solar PV systems include a battery storage component, groundwater can be pumped continuously day and night in a year-round schedule. However, due to the high cost premium of the energy storage component, a fully solar-powered solution could not provide an economic direct replacement for line-powered pumping systems. As a result, the most ideal target locations for successful implementation of solar PV on the Hanford Site are remote or distant extraction wells where the primary remedial objective is contaminant mass removal (as opposed to hydraulic containment) and three-season (March through October) intermittent pumping is acceptable (e.g. remediation of hexavalent chromium in 200-UP-1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multijunction InGaAs thermophotovoltaic power converter

The experimental performance of a multijunction monolithic In(0.53)Ga(0. 47)As power converter under blackbody irradiation is reported. Eight InGaAs PN junctions grown epitaxially on a semi-insulating wafer were monolithically integrated in series to boost the approximately 0.4 V photovoltage per typical InGaAs junction to over 3 volts for the 1 sq cm chip. This chip was originally designed and characterized for free-space 1.3 micron laser power beaming. This is the first report of such a multijunction TPV. This is not a traditional tandem cell in which the junctions are stacked vertically. The junctions are each about 1mm long by 1 cm wide and are laterally connected across the 1 sq cm device area. This multijunction design has the potential for lower I(sup 2)R power loss since the smaller PN junction area limits the current to one-eighth that of the equivalent surface area. In essence, the current is traded for voltage to avoid the I(sup 2)R loss, analogous to the way power utilities avoid I(sup 2)P loss in high-tension power lines, by transforming the high current, low voltage generated at a power plant into a high voltage at a low current before transmitting the power over great distances.

Wojtczuk, Steven↗

Multijunction InGaAs thermophotovoltaic power converter

The experimental performance of a multijunction monolithic lattice-matched 0.74 eV InGaAs thermophotovoltaic (TPV) power converter under 980 C blackbody irradiation is reported. Eight InGaAs PN junctions grown epitaxially on a semi-insulating wafer were monolithically integrated in series to boost the approximately 0.4 V photovoltage per typical InGaAs junction to over 3 volts for the 1 cm(exp 2) chip. This chip was originally designed and characterized for free-space 1.3 micron laser power beaming. The power efficiency of this TPV device is 16% for that part of the blackbody spectrum above the material bandgap. The device is shown to deliver about 1 watt of output power when driven with enough light. This is the first report of such a multijunction TPV device. This is not a traditional tandem cell in which the junctions are stacked vertically. Eight 1 mm long by 1 cm wide junctions are laterally connected across the device area. This multijunction design has the potential for lower I(exp 2)R power loss since the smaller PN junction area limits the current to one eighth that of the equivalent surface area. In essence, the current is traded for voltage to avoid the I(exp 2)R loss, analogous to the way power utilities avoid I(exp 2)R loss in high-tension power lines, by transforming the high current, low voltage generated at a power plant into a high voltage at a low current before transmitting the power over great distances.

Wojtczuk, Steven↗