Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analytic Solutions Of Equations For Q-Switched Lasers

Approximate closed-form, analytic equations for characteristics of Q-switched, continuous-wave-pumped laser express relationships among characteristics of output, pumping rate above threshold pumping rate, and rate of repetition of switch. Equations describe performance in terms of peak output power, energy in each pulse, average output power, and duration of each pulse as functions of pulse-repetition rate, actual pump power, threshold pump power, volume occupied by laser electromagnetic mode, and reflectivity of output coupler. Useful for analyzing performances of diode-pumped solid-state lasers.

Wilson, Keith E.↗

Torque Reversal and Spin-Down of the Accretion-Powered Pulsar 4U 1626-67

Over 5 yr of hard X-ray (20-60 keV) monitoring of the 7.66 s accretion-powered pulsar 4U 1626-67 with the Compton Gamma Ray Observatory/BATSE large-area detectors has revealed that the neutron star is now steadily spinning down, in marked contrast to the steady spin-up and spin-down torques differ by only 15% with the neutron star spin changing on a timescale |v/v| approximately equals 5000 yr in both states. The current spin-down rate is itself decreasing on a timescale |v/v| approximately equals 26 yr. The long-term timing history shows small-amplitude variations on a 4000 day timescale, which are probably due to variations in the mass transfer rate. The pulsed 20-60 keV emission from 4U 1626-67 is well-fitted by a power-law spectrum with photon index gamma = 4.9 and a typical pulsed intensity of 1.5 x 10(exp -10) ergs cm (exp -2)s(exp -1). The low count rates with BATSE prohibited us from constraining the reported 42 minute binary orbit, but we can rule out long-period orbits in the range 2 days < or = P(orb) < or = 900 days. We compare the long-term torque behavior of 4U 1626-67 to other disk-fed accreting pulsars and discuss the implications of our results for the various theories of magnetic accretion torques. The abrupt change in the sign of the torque is difficult to reconcile with the extremely smooth spin-down now observed. The strength of the torque noise in 4U 1626-67, approximately 10(exp -22) Hz(exp 2)s(exp -2) Hz(exp -1), is the smallest ever measured for an accreting X-ray pulsar, and it is comparable to the timing noise seen in young radio pulsars. We close by pointing out that the core temperature and external torque (the two parameters potentially relevant to internal sources of timing noise) of an accreting neutron star are also comparable to those of young radio pulsars.

Chakrabarty, Deepto L.↗

Response of NiMH Cells to Burp Charging

Performance cycling and calorimetric analysis of nickel metal hydride (NNH) calls have revealed that reverse pulse ("burp") charging improves performance over other charging techniques. Burp charging periodically applies a short-duration, high-rate discharge pulse followed by short rest during an otherwise galvanostatic charge as shown in Fig. 1. Results show improved charge input and output, lower heat generation during charge, lower charge overvoltage, and no loss of cycle life [I]. The burp charge method has been improved over the years purely by trial and error. Several hypotheses have been put forward (see articles cited in (1) to explain why burp charging improves performance For example, it has been suggested that the discharge pulses dislodge gas bubbles that would otherwise mask the active elect-ode surfaces. However, no evidence was found in the literature to support this or other hypotheses. Overall, a better understanding of the phenomenon is needed to help guide further improvements in the burp-charging method, and this is the objective of our investigation.

Darcy, Eric C.↗

Design and Performance of a Miniature Lidar Wind Profiler (MLWP)

The directional velocity of the wind is one of the most critical components for understanding meteorological and other dynamic atmospheric processes. Altitude-resolved wind velocity measurements, also known as wind profiles or soundings, are especially necessary for providing data for meteorological forecasting and overall global circulation models (GCM's). Wind profiler data are also critical in identifying possible dangerous weather conditions for aviation. Furthermore, a system has yet to be developed for wind profiling from the surface of Mars which could also meet the stringent requirements on size, weight, and power of such a mission. Obviously, a novel wind profiling approach based on small and efficient technology is required to meet these needs. A lidar system based on small and highly efficient semiconductor lasers is now feasible due to recent developments in the laser and detector technologies. The recent development of high detection efficiency (50%), silicon-based photon-counting detectors when combined with high laser pulse repetition rates and long receiver integration times has allowed these transmitter energies to be reduced to the order of microjoules per pulse. Aerosol lidar systems using this technique have been demonstrated for both Q-switched, diode-pumped solid-state laser transmitters (lambda = 523 nm) and semiconductor diode lasers (lambda = 830 nm); however, a wind profiling lidar based on this technique has yet to be developed. We will present an investigation of a semiconductor-laser-based lidar system which uses the "edge-filter" direct detection technique to infer Doppler frequency shifts of signals backscattered from aerosols in the planetary boundary layer (PBL). Our investigation will incorporate a novel semiconductor laser design which mitigates the deleterious effects of frequency chirp in pulsed diode lasers, a problem which has limited their use in such systems in the past. Our miniature lidar could be used on a future Mars lander and perhaps find its own niche in terrestrial applications due to its potential low cost an small size.

Cornwell, Donald M., Jr.↗

The Advanced Topographic Laser Altimeter System (ATLAS) for NASA's Ice Cloud and Land Elevation Satellite-2 (ICESat-2): Design, Development, and On-Orbit Performance

Conceived in response to the 2007 Earth Science Decadal Survey, ATLAS/ICESat-2 was launched on September 15, 2018 to a polar orbit and has been operating continuously since. The ATLAS instrument is a continuously-operating direct-detection pulsed laser altimeter utilizing a solid-state 532-nm laser source operating at a 10-kHz pulse repetition rate along with a diffractive optic to illuminate six 15-meter spots on the Earth's surface with each laser pulse. An 80-cm receiver telescope fiber-coupled to segmented photomultipliers provides single-photon detection capability. This presentationr will present an overview of the ATLAS instrument design, some challenges encountered during development, and initial results from orbit.

Lidar↗

Ultrastable reference pulser for high-resolution spectrometers

Solid-state double-pulse generator for a high resolution semiconductor detector meets specific requirements for resolution /0.05 percent/, amplitude range /0.1-13 MeV/, and repetition rate /0.1-1000 pulses per second/. A tag pulse is generated in coincidence with each reference pulse.

Brenner, R.↗

Real-Time Optical Receiver Decoder Architecture Changes for High-Speed Modes

The National Aeronautics and Space Administration (NASA) at Glenn Research Center (GRC) has developed an optical communications transmitter and receiver using Commercial-off-the-shelf (COTS) components. The goal of this project is to become fully compliant with Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard. The receive modem’s decoder has been modified using shift registers to enable the decoding of higher data rate pulse-position modulation (PPM) 4 and PPM-8 signals. PPM-4 and PPM-8 is then verified by comparing the codeword error rate (CWER) of a hardware implementation to a software simulation. The changes show the capability to decode PPM-4 and PPM-8 for a single decoder. This memorandum details the changes made, the performance achieved with the changes, and necessary future work.

PPM↗

Discovery of Soft X-ray Pulsations from PSR J1231-1411 using NICER

We report the discovery of soft X-ray pulsations from the nearby millisecond pulsar PSR J1231−1411 using the Neutron Star Interior Composition Explorer (NICER). The pulsed emission is characterized by a broad and asymmetric main pulse and a much fainter secondary interpulse, with a total pulsed count rate of 0.055 c s−1 in the 0.35–1.5 keV band. We analyzed Fermi Large Area Telescope (LAT) data to update the pulse timing model covering 10 yr of data and used that model to coherently combine NICER data over a year of observations. Spectral modeling suggests that the flux is dominated by thermal emission from a hot spot (or spots) on the neutron star surface. The phase relationship between the X-ray pulse and the radio and γ rays provides insight into the geometry of the system.

gamma rays↗

Measurements of the effect of horizontal variability of atmospheric backscatter on dial measurements

The horizontal variability of atmospheric backscatter may have a substantial effect on how Differential Absorption Lidar (DIAL) data must be taken and analyzed. To minimize errors, lidar pulse pairs are taken with time separations which are short compared to the time scales associated with variations in atmospheric backscatter. To assess the atmospheric variability for time scales which are long compared to the lidar pulse repetition rate, the variance of the lidar return signal in a given channel can be computed. The variances of the on-line, off-line, and ration of the on-line to off-line signals at given altitudes obtained with the dual solid-state Alexandrite laser system were calculated. These evaluations were made for both down-looking aircraft and up-looking ground-based lidar data. Data were taken with 200 microsecond separation between on-line and off-line laser pulses, 30 m altitude resolution, 5 Hz repetition rate, and the signal were normalized for outgoing laser energy.

Schwemmer, G. K.↗

Circuit Stops Prelasing In A Q-Switched Laser

Protective shutdown circuit stops prelasing in Q-switched laser operating at pulse-repetition rate of about 10 Hz. During normal operation, Q-switch prevents emission of light from laser cavity during application of Q-switch-trigger pulse. When circuit detects prelasing, it triggers relay turning off laser power supply. Circuit integrated into almost any Q-switched-laser system, provided one gains access to laser light, Q-switch-trigger pulse, and safety-interlock line of laser power supply.

Lockard, George E.↗

A wide angle search technique for a 10.6 micron ladar

A ladar (laser radar) sensor designed around a pulsed passively Q-switched CO2 laser, capable of a efficient and rapid scans with a narrow beam over a wide field of view, is considered for surveillance and tracking applications in space. The output is a train of narrow pulses with a controllable pulse repetition rate. A resonant vibrating mirror in back of a classical Gregorian telescope, and a plane pointing mirror in front for beam steering, are used in scanning. Scan pulse sequences are described and illustrated. The 10.6 micron ladar set is under consideration as baseline sensor for various space rendezvous and docking applications.

Levinson, S.↗

Microaltimeter

A microaltimeter measures altitude or range highly accurately from an orbiting vehicle. The microaltimeter has a low power solid state laser that is pulsed at a rate above 1 kilohertz. The pulses are delivered to a small telescope which sends them to a planetary surface and receives return reflections. A high efficiency photon detector measures received photons and supplies received photon signals to a process or which makes a time-based bin-wise comparison to find the time of flight and hence the range.

Degnan, John J↗

Bench checkout equipment for spaceborne laser altimeter systems

This paper addresses the requirements for testing and characterizing spaceborne laser altimeter systems. The Bench Checkout Equipment (BCE) system, test requirements, and flow-down traceability from the instrument system's functional requirements will also be presented. Mars Observer Laser Altimeter (MOLA) and the MOLA BCE are presented as representative of a 'typical' laser altimeter and its corresponding test system. The testing requirements of other or future laser altimeter systems may vary slightly due to the specific spacecraft interface and project requirements. MOLA, the first solid-state interplanetary laser altimeter, was designed to be operational in Mars orbit for two Earth years. MOLA transmits a 7.5 ns pulse at a wavelength of 1.064 microns with a 0.25 mr beam divergence and a pulse repetition rate of 10 Hz. The output energy is specified at 45 mj at the beginning of mapping orbit and 30 mj at the end of one Martian year. MOLA will measure the laser pulse transit time from the spacecraft to the Mars surface and return to a resolution of 1.5 meters.

Smith, James C.↗

Requirements and Technology Advances for Global Wind Measurement with a Coherent Lidar: A Shrinking Gap

Early concepts to globally measure vertical profiles of vector horizontal wind from space planned on an orbit height of 525 km, a single pulsed coherent Doppler lidar system to cover the full troposphere, and a continuously rotating telescope/scanner that mandated a vertical line of sight wind profile from each laser shot. Under these conditions system studies found that laser pulse energies of approximately 20 J at 10 Hz pulse repetition rate with a rotating telescope diameter of approximately 1.5 m was required. Further requirements to use solid state laser technology and an eyesafe wavelength led to the relatively new 2-micron solid state laser. With demonstrated pulse energies near 20 mJ at 5 Hz, and no demonstration of a rotating telescope maintaining diffraction limited performance in space, the technology gap between requirements and demonstration was formidable. Fortunately the involved scientists and engineers set out to reduce the gap, and through a combination of clever ideas and technology advances over the last 15 years, they have succeeded. This paper will detail the gap reducing factors and will present the current status.

Kavaya, Michael J.↗

Every Good Virtue You Ever Wanted in a Q-switched Solid-state Laser and More: Monolithic, Diode-pumped, Self-q-switched, Highly Reproducible, Diffraction-limited Nd:yag Laser

The applications of Q-switched lasers are well known, for example, laser radar, laser remote sensing, satellite orbit determination, Moon orbit and 'moon quake' determination, satellite laser communication, and many nonlinear optics applications. Most of the applications require additional properties of the Q-switched lasers, such as single-axial and/or single-transverse mode, high repetition rate, stable pulse shape and pulse width, or ultra compact and rugged oscillators. Furthermore, space based and airborne lasers for lidar and laser communication applications require efficient, compact, lightweight, long-lived, and stable-pulsed laser sources. Diode-pumped solid-state lasers (DPSSL) have recently shown the potential for satisfying all of these requirements. We will report on the operating characteristics of a diode-pumped, monolithic, self-Q-switched Cr,Nd:YAG laser where the chromium ions act as a saturable absorber for the laser emission at 1064 nm. The pulse duration is 3.5 ns and the output is highly polarized with an extinction ratio of 700:1. It is further shown that the output is single-longitudinal-mode with transform-limited spectral line width without pulse-to-pulse mode competition. Consequently, the pulse-to-pulse intensity fluctuation is less than the instrument resolution of 0.25 percent. This self-stabilization mechanism is because the lasing mode bleaches the distributed absorber and establishes a gain-loss grating similar to that used in the distributed feedback semiconductor lasers. A repetition rate above 5 KHz has also been demonstrated. For higher power, this laser can be used for injection seeding an amplifier (or amplifier chain) or injection locking of a power oscillator pumped by diode lasers. We will discuss some research directions on the master oscillator for higher output energy per pulse as well as how to scale the output power of the diode-pumped amplifier(s) to multi-kilowatt average power.

Chen, Y. C.↗

Rotational relaxation measurements in ozone - Temperature and collision partner effects

Time-resolved infrared double resonance experiments have been conducted on ozone mixtures in order to determine rotational relaxation rates. A pulsed CO2 laser pumps a nu(3)-ground state transition, while a diode laser is tuned to a hot band transition so that the relaxation process in nu(3) = 1 may be observed. Nitrogen, oxygen, rare gas, and self-relaxation rates have been measured, and the temperature dependence of these rates has been investigated over the 200-300 K range.

Flannery, C. C.↗