Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle beam measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Erosion of an electron-beam front in a long beam-plasma system

The front of an electron beam injected into a uniform, magnetized plasma is observed to erode rapidly because of scattering of the beam electrons via collective beam-plasma interactions. The propagation of the beam front is measured with temporal and axial resolution via beam excitation light. A broadened light front can result that propagates much slower than the injected beam particle speed.

Chan, L. Y.↗

Drop size distribution and air velocity measurements in air assist swirl atomizer sprays

Detailed measurements of mean drop size (SMD) and size distribution parameters have been made using a Fraunhofer diffraction particle sizing instrument in a series of sprays generated by an air assist swirl atomizer. Thirty-six different combinations of fuel and air mass flow rates were examined with liquid flow rates up to 14 lbm/hr and atomizing air flow rates up to 10 lbm/hr. Linear relationships were found between SMD and liquid to air mass flow rate ratios. SMD increased with distance downstream along the center line and also with radial distance from the axis. Increase in obscuration with distance downstream was due to an increase in number density of particles as the result of deceleration of drops and an increase in the exposed path length of the laser beam. Velocity components of the atomizing air flow field measured by a laser anemometer show swirling jet air flow fields with solid body rotation in the core and free vortex flow in the outer regions.

Mao, C.-P.↗

A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

NASA Center HQS↗

Measurements of Electrical and Electron Emission Properties of Highly Insulating Materials

Highly insulating materials often acquire significant charges when subjected to fluxes of electrons, ions, or photons. This charge can significantly modify the materials properties of the materials and have profound effects on the functionality of the materials in a variety of applications. These include charging of spacecraft materials due to interactions with the severe space environment, enhanced contamination due to charging in Lunar of Martian environments, high power arching of cables and sources, modification of tethers and ion thrusters for propulsion, and scanning electron microscopy, to name but a few examples. This paper describes new techniques and measurements of the electron emission properties and resistivity of highly insulating materials. Electron yields are a measure of the number of electrons emitted from a material per incident particle (electron, ion or photon). Electron yields depend on incident species, energy and angle, and on the material. They determine the net charge acquired by a material subject to a give incident flu. New pulsed-beam techniques will be described that allow accurate measurement of the yields for uncharged insulators and measurements of how the yields are modified as charge builds up in the insulator. A key parameter in modeling charge dissipation is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across an insulator, as well as the time scale for charge transport and dissipation. Comparison of new long term constant-voltage methods and charge storage methods for measuring resistivity of highly insulating materials will be compared to more commonly used, but less accurate methods.

Dennison, J. R.↗

A sun-aligned arc observed by DMSP and AE-C

On May 12, 1977, 8 minutes after a DMSP satellite photographed a sun-aligned auroral arc in the southern polar cap, AE-C crossed over the same arc. Precipitating electrons were observed with a peak energy flux of 0.94 erg per sq cm s but with no clear monoenergetic beam, and coincident ion precipitation was measured at energies of a few keV. A very sharp ion convection reversal was found coincident with the particle precipitation and embedded in a region of constant antisunward flow. Magnetic field data indicate that the arc occurred during the recovery phase of a weak magnetic storm, with the IMF in a toward sector and the Z component nearly zero. The data are consistent with a source of particles at altitudes of the order of 5-8 R(E) on field lines containing the plasma sheet boundary layer. The electron spectra do not indicate the existence of an electrostatic potential along the magnetic field lines projecting from the arc. The electrodynamic properties associated with the arc appear to be consistent with a simple model in which field-aligned currents are required along any boundary where the horizontal ionospheric current diverges.

Hoffman, R. A.↗

Nonintrusive optical single-particle counter for measuring the size and velocity of droplets in a spray

A technique for measuring nonintrusively, and in real time, the size and velocity of droplets in a spray is presented. A small beam identifies the center of a larger beam, thus defining a region of almost uniform intensity, and only droplets crossing through such a center are measured. The size is obtained from the absolute scattered light and the velocity from the modulated signal produced by the interferometric pattern. A self-calibrating algorithm is also discussed. Results are presented for a spray of predictable chracteristics.

Hess, C. F.↗

Energetic ion and electron beams at the plasma-sheet boundary in the distant tail

Several energetic particle bursts observed by ISEE 3 in the distant tail are analyzed. The energetic particle data are supplemented by the electron plasma and magnetic field measurements. These bursts are characterized by large velocity-dispersion effects, with energetic electrons observed first, followed by ions with continuously lower velocities. Both ions and electrons stream in the tailward direction. Protons and alpha particles of the same energy per nucleon are observed at the same time. The dispersion effects are observed in reverse order when the spacecraft leaves from the boundary layer into the lobe. No obvious signature indicating the passage of a plasmoid has been observed in the particle or magnetic field data during or immediately following these bursts. It is concluded that these beams at the plasma-sheet boundary originate at a steady source, presumably close to a neutral line, and not at a time varying source. The velocity filter effect in a dawn-dusk electric field arranges particles with progressively lower velocity further inside the wedge-shaped region of reconnected field lines. The plasma electron distribution exhibits a tailward directed heat flux within this layer.

Scholer, M.↗

Distributed Disdrometer and Rain Gauge Measurement Infrastructure Developed for GPM Ground Validation

Global Precipitation Mission (GPM)retrieval algorithm validation requires datasets characterizing the 4-D structure, variability, and correlation properties of hydrometeor particle size distributions (PSD) and accumulations over satellite fields of view (FOV;<10 km). Collection of this data provides a means to assess retrieval errors related to beam filling and algorithm PSD assumptions. Hence, GPM Ground Validation is developing a deployable network of precipitation gauges and disdrometers to provide fine-scale measurements of PSD and precipitation accumulation variability. These observations will be combined with dual-frequency, polarimetric, and profiling radar data in a bootstrapping fashion to extend validated PSD measurements to a large coverage domain. Accordingly, a total of 24 Parsivel disdrometers(PD), 5 3rd-generation 2D Video Disdrometers (2DVD), 70 tipping bucket rain gauges (TBRG),9 weighing gauges, 7 Hot-Plate precipitation sensors (HP), and 3 Micro Rain Radars (MRR) have been procured. In liquid precipitation the suite of TBRG, PD and 2DVD instruments will quantify a broad spectrum of rain rate and PSD variability at sub-kilometer scales. In the envisioned network configuration 5 2DVDs will act as reference points for 16 collocated PD and TBRG measurements. We find that PD measurements provide similar measures of the rain PSD as observed with collocated 2DVDs (e.g., D0, Nw) for rain rates less than 15 mm/hr. For heavier rain rates we will rely on 2DVDs for PSD information. For snowfall we will combine point-redundant observations of SWER distributed over three or more locations within a FOV. Each location will contain at least one fenced weighing gauge, one HP, two PDs, and a 2DVD. MRRs will also be located at each site to extend the measurement to the column. By collecting SWER measurements using different instrument types that employ different measurement techniques our objective is to separate measurement uncertainty from natural variability in SWER and PSD. As demonstrated using C3VP polarimetric radar, gauge, and 2DVD/PD datasets these measurements can be combined to bootstrap an area wide SWER estimate via constrained modification of density-diameter and radar reflectivity-snowfall relationships. These data will be combined with snowpack, airborne microphysics, radar, radiometer, and tropospheric sounding data to refine GPM snowfall retrievals. The gauge and disdrometer instruments are being developed to operate autonomously when necessary using solar power and wireless communications. These systems will be deployed in numerous field campaigns through 2016. Planned deployment of these systems include field campaigns in Finland (2010), Oklahoma (2011), Canada (2012) and North Carolina (2013). GPM will also deploy 20 pairs of TBRGs within a 25 km2 region along the Virginia coast under NASA NPOL radar coverage in order to quantify errors in point-area rainfall measurements.

Petersen, Walter A.↗

Measurements of Lunar Dust Charging Properties by Electron Impact

Dust grains in the lunar environment are believed to be electrostatically charged predominantly by photoelectric emissions resulting from solar UV radiation on the dayside, and on the nightside by interaction with electrons in the solar wind plasma. In the high vacuum environment on the lunar surface with virtually no atmosphere, the positive and negative charge states of micron/submicron dust grains lead to some unusual physical and dynamical dust phenomena. Knowledge of the electrostatic charging properties of dust grains in the lunar environment is required for addressing their hazardous effect on the humans and mechanical systems. It is well recognized that the charging properties of individual small micron size dust grains are substantially different from the measurements on bulk materials. In this paper we present the results of measurements on charging of individual Apollo 11 and Apollo 17 dust grains by exposing them to mono-energetic electron beams in the 10-100 eV energy range. The charging/discharging rates of positively and negatively charged particles of approx. 0.1 to 5 micron radii are discussed in terms of the sticking efficiencies and secondary electron yields. The secondary electron emission process is found to be a complex and effective charging/discharging mechanism for incident electron energies as low as 10-25 eV, with a strong dependence on particle size. Implications of the laboratory measurements on the nature of dust grain charging in the lunar environment are discussed.

Abbas, Mian M.↗

Beam profiles measured with thermoluminescent dosimeters

Beam profilometer, using thermoluminescent dosimeters, gives a quantitative and qualitative representation of the focus of an external protron beam of a synchrotron. The total number of particles in the beam, particle distribution, and the shape of the beam are determined.

Lucks, H.↗

In Vitro Studies on Space Radiation-Induced Delayed Genetic Responses: Shielding Effects

Understanding the radiation risks involved in spaceflight is of considerable importance, especially with the long-term occupation of ISS and the planned crewed exploration missions. Several independent causes may contribute to the overall risk to astronauts exposed to the complex space environment, such as exposure to GCR as well as SPES. Protons and high-Z energetic particles comprise the GCR spectrum and may exert considerable biological effects even at low fluence. There are also considerable uncertainties associated with secondary particle effects (e.g. HZE fragments, neutrons etc.). The interaction of protons and high-LET particles with biological materials at all levels of biological organization needs to be investigated fully in order to establish a scientific basis for risk assessment. The results of these types of investigation will foster the development of appropriately directed countermeasures. In this study, we compared the biological responses to proton irradiation presented to the target cells as a monoenergetic beam of particles of complex composition delivered to cells outside or inside a tissue phantom head placed in the United States EVA space suit helmet. Measurements of chromosome aberrations, apoptosis, and the induction of key proteins were made in bone marrow from CBA/CaJ and C57BL/6 mice at early and late times post exposure to radiation at 0, 0.5, 1 and 2 Gy while inside or outside of the helmet. The data showed that proton irradiation induced transmissible chromosomal/genomic instability in haematopoietic stem cells in both strains of mice under both irradiation conditions and especially at low doses. Although differences were noted between the mouse strains in the degree and kinetics of transforming growth factor-beta 1 and tumor necrosis factor-alpha secretion, there were no significant differences observed in the level of the induced instability under either radiation condition, or for both strains of mice. Consequently, when normalized to physical dose, the monoenergetic proton field present inside the helmet-protected phantom produced equivalent biological responses, when compared to unshielded cells, as measured by the induction of delayed genetic effects in murine haematopoietic stem cells.

Kadhim, Munira A.↗

Determination of particle size using measurement of scatter

Scatter from glass beads placed on a mirror was measured using a quartz lamp and laser. Data were obtained in the plane containing the normal to the surface and the incident beam. For the quartz lamp the best correlation can be obtained for data measured at a zenith of 55 deg and 180 deg from the incident beam. The best correlation when the laser is used is obtained at about the same position. However, the correlation variables are angular spacing of the minimums of the data versus the size. Whereas, with the quartz lamp the correlation variables are the amount of scattered energy versus size.

Scott, R. L., Jr.↗

A New Instrument for the Continuous Measurement of Condensation Nuclei

An instrument is described which provides a continuous measurement of airborne particle concentrations in the size range down to 0.00 1 microns. The concentration range of the instrument is from 10 to 10 (sup 7) particles per cubic centimeter with a response time in the order of 1 to 2 seconds. The Instrument is designed for continuous unattended operation and employs a unique dual beam, single phototube optical system in which the reference beam passes through the same optical elements as the measuring beam.

Skala, George F.↗

Optical properties of cometary dust

The application of measured optical constants to the interaction of electromagnetic radiation with small cometary dust particles is discussed, with emphasis on the interpretation of cometary observations. It is found that in some spectral regions optical constants vary greatly with wavelength. The optical constants may be incorrect. Because of errors in measurement, or the application of the Kramers-Kronig relationship over too small a spectral region, or an improperly prepared sample, the derived optical constants may be in error. It is suggested that a full Kramers-Kronig analysis and application of the more important sum rules should be performed on any set of optical constants whose accuracy is important. Optical constants derived from the measurement of inhomogeneous materials, where the inhomogeneities are of comparable size to that of the beam of radiation used in the experiment, should not be used to predict the optical properties of small particles.

Lien, David J.↗

Optical model methods of predicting nuclide production cross sections from heavy ion fragmentation

Quantum mechanical optical potential methods for calculating inclusive isotope and element production cross sections from the fragmenting of heavy nuclei by intermediate- and high-energy protons and heavy ions are presented based upon a modified abrasion-ablation-FSI (frictional spectator interaction) collision model. The abrasion stage is treated as a quantum mechanical knockout process that leaves the residual prefragment in an excited state. Prefragment excitation energies are estimated using a combined liquid drop and FSI method. In ablation the prefragment deexcites by particle and photon emission to produce the final fragment. Contributions from electromagnetic dissociation to single nucleon removal cross sections are incorporated using a Weiszacker-Williams theory that includes electric dipole and electric quadrupole interactions. Estimates of elemental and isotopic production cross sections are in good agreement with published cross section measurements for a variety of projectile-target-beam energy combinations.

NASA Discipline Radiation Health↗

Ion beam sputtering of liquid metals.

Sputtering yields and energy-transfer efficiency measurements by ion beam sputtering of liquid metals indicate no justification for incorporation into low thrustor

METAL PARTICLE↗

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.↗