Results of a 1970 Geminid dust particle rocket experiment and analysis of OGO III dust particle velocity measurements
Geminid meteoroid dust particles detection, determining velocity and orbital elements from OGO 3 flux measurements
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Geminid meteoroid dust particles detection, determining velocity and orbital elements from OGO 3 flux measurements
Two designs of plastic scintillation counters with an area of 2 sq m scanned in each case by a single photomultiplier of the FEU-49 type are described. The radial dependence of their light collection at the place of the path of the detected particle does not exceed 10% while the half width of the differential distribution of the pulse amplitudes from nonfiltered cosmic radiation at sea level is 90 to 95%, and 65%, the plastic thickness being 5 cm and 10 cm, respectively. The temperature coefficient of the counter is 0.32% per 1 C.
Between December 1964 and December 1967, the Mariner 4 dust particle experiment obtained data concerning the distribution of minute zodiacal dust cloud particles over a heliocentric range of 1-1.56 AU. The first measurement was over the complete heliocentric range, while the two additional measurements were made between 1.1 and 1.25 AU in 1966, and between 1.2 and 1.5 AU in 1967. The initial results of these measurements presented the mean cumulative flux for the respective data periods. The results of a detailed study and comparison of the three measurements are presented, with particular emphasis on the variation of the flux as a function of heliocentric range. A small, but statistically significant, increase in the flux is observed between 1.15 and 1.4 AU. The initial reports showed a lower cumulative flux for the latter two measurements. However, a detailed analysis containing corrections for spacecraft attitude indicate that all three measurements yield similar results, and that the particles detected were in low inclination orbits.
The design of large area transition radiation detectors for highly relativistic particles can be greatly simplified if plastic foam radiators are employed. Using electron beams with energies 1-9 GeV at the Cornell synchrotron, we have studied the properties of a large variety of transition radiators consisting of commercially available foam materials. In most cases, a measurable transition radiation signal has been observed, but only a few materials have been found to be suitable for practical purposes. The observed radiation yield is in these cases very similar to that of equivalent multifoil radiators. A detailed discussion is given of the particle detection efficiency that can be obtained with high yield foam radiators.
An improved high-voltage stepping supply, for space instrumentation is described where low power consumption and fast settling time between steps are required. The high-voltage stepping supply, utilizing an average power of 750 milliwatts, delivers a pair of mirror images with 64 level logarithmic outputs. It covers a four decade range of + or - 2500 to + or - 0.29 volts having an output stability of + or - 0.5 percent or + or - 20 millivolts for all line load and temperature variations. The supply provides a typical step setting time of 1 millisecond with 100 microseconds for the lower two decades. The versatile design features of the high-voltage stepping supply provides a quick response staircase generator as described or a fixed voltage with the option to change levels as required over large dynamic ranges without circuit modifications. The concept can be implemented up to + or - 5000 volts. With these design features, the high-voltage stepping supply should find numerous applications where charged particle detection, electro-optical systems, and high voltage scientific instruments are used.
Using the ISEE-3 radio astronomy experiment data 37 interplanetary (IP) type II bursts have been identified in the period September 1978 to December 1981. These events and the associated phenomena are listed. The events are preceded by intense, soft X ray events with long decay times (LDEs) and type II and/or type IV bursts at meter wavelengths. The meter wavelength type II bursts are usually intense and exhibit herringbone structure. The extension of the herringbone structure into the kilometer wavelength range results in the occurrence of a shock accelerated (SA) event. The majority of the interplanetary type II bursts are associated with energetic particle events. These results support other studies which indicate that energetic solar particles detected at 1 A.U. are generated by shock acceleration. From a preliminary analysis of the available data there appears to be a high correlation with white light coronal transients.
Using the ISEE-3 radio astronomy experiment data 37 interplanetary (IP) type II bursts have been identified in the period September 1978 to December 1981. These events and the associated phenomena are listed. The events are preceded by intense, soft X ray events with long decay times (LDEs) and type II and/or type IV bursts at meter wavelengths. The meter wavelength type II bursts are usually intense and exhibit herringbone structure. The extension of the herringbone structure into the kilometer wavelength range results in the occurrence of a shock accelerated (SA) event. The majority of the interplanetary type II bursts are associated with energetic particle events. These results support other studies awhich indicate that energetic solar particles detected at 1 A.U. are generated by shock acceleration. From a preliminary analysis of the available data there appears to be a high correlation with white light coronal transients.
The high altitude plasma instrument, i.e., five electrostatic analyzers, on board the DE 1 satellite obtained data on electron conical distributions during two nightside auroral zone passes and one polar cap pass. The southern orbit apogee was 675 km, the northern, 24,000 km. Electrons confined to the outside of the loss cone were the highest energy particles detected. The upward integrated flux was greater than the downward flux, indicating the presence of a heating process perpendicular to the geomagnetic field.
The ASTROMAG facility is the heart of a large charged particle detection and resolution system. ASTROMAG utilizes a superconducting magnet consisting of a large superconducting magnet coil with a stored magnetic energy of approximately 15 MJ. The active coil will have a mass of 1200 kg. This magnet will be cooled by a cryostat using a liquid helium Dewar for storage. The cryostat will have a series of gas-cooled shields with an external guard vacuum shield and an internal Dewar. The magnet and cryostat will be designed for shuttle or Delta launch and will be designed to withstand the internal pressure of expanded helium under full quench conditions when venting is prevented. The external guard vacuum shell is required to maintain a vacuum for Earth based testing and for cold launch of the cryostat and magnet. The magnet is designed to operate at 4.4 K with a peak field of 7.0 tesla. The superconducting material within the magnet is niobium titanium in a conductive matrix.
The primary scientific objectives of ASTROMAG are to: examine cosmological models by searching for antimatter and dark matter candidates; study the origin and evolution of matter in the galaxy by direct sampling of galactic matter; and study the origin and acceleration of the relativistic particle plasma in the galaxy and its effects on the dynamics and evolution of the galaxy. These general scientific objectives will be met by ASTROMAG with particle detection instruments designed to make the following observations: search, for anti-nuclei of helium and heavier element; measure the spectra of anti-protons and positrons; measure the isotopic composition of cosmic ray nuclei at energies of several GeV/amu; and measure the energy spectra of cosmic ray nuclei to very high energies.
The highest-quality impact mass spectrometer data from the Vega-1 and Giotto spacecraft are presently used to study the Mg, Si, and Fe composition of dust grains in Comet Halley. The results thus obtained are in general agreement with previously reported data, but differ with respect to ion ratio dispersions. A lack of sharp clustering in the data indicates that none of the detected particles can be characterized as single mineral grains; an abundant glass content in the solids may be indicated. The best match of the distribution of Fe/(Fe+Mg) is with interplanetary particles containing high temperature, Mg-rich silicates dominated by anhydrous minerals, so that Comet Halley may be a mixture of ice and high-temperature anhydrous minerals.
In this paper, mission orbit considerations are addressed for using the Space Shuttle as a telescope platform for observing man-made orbital debris. Computer modeling of various electrooptical systems predicts that such a space-borne system will be able to detect particles as small as 1-mm diameter. The research is meant to support the development of debris- collision warning sensors through the acquisition of spatial distribution and spectral characteristics for debris and testing of detector combinations on a shuttle-borne telescopic experiment. The technique can also be applied to low-earth-orbit-debris environment monitoring systems. It is shown how the choice of mission orbit, season of launch, and time of day of launch may be employed to provide extended periods of favorable observing conditions.
Conventional X-ray microcalorimeters have so far used ionimplanted resistors for thermometers. Recently, however, several new methods for sensing small temperature changes have been suggested that are nondissipative. Such devices may have intrinsically better energy resolution by eliminating the Johnson noise present in resistive devices. The use of kinetic inductance thermometers for X-ray microcalorimeters is being investigated. This technique exploits the strong temperature dependence of magnetic penetration depth of thin superconducting films. The prototype system, designed for operation at 1.5 K, uses films of aluminum and tin. Once the expected temperature sensitivity and alpha particle detection have been demonstrated, aluminum will be replaced with titanium or another material with a suitable critical temperature and the device will be operated at 0.3 K. At this temperature, the energy resolution from thermal noise should be sufficiently good to allow X-ray detection.
The Return Data Delay technique which requires knowledge of spacecraft range is commonly used for correlating a spacecraft clock against a ground time standard when millisecond accuracy is required. An analysis is presented that allows using the user spacecraft clock calibration system (USCCS) to correlate a spacecraft clock to better than one microsecond accuracy. The basic USCCS algorithm has been simplified and it is shown to result in about one microsecond accuracy without requiring orbital information. By considering the relative motion of the user satellite, the TDRS and the earth station about the center of the earth, a correction of almost two orders of magnitude can be made. Such accuracy is required for scientific investigations that require correlating coincident radiation or particle detection with a remote laboratory.
Specific measurement of cirrus crystals by aircraft and temperature modified CN are used to specify measurements necessary to provide a basis for a conceptual model of cirrus particle formation. Key to this is the ability to measure the complete spectrum of particles at cirrus levels. The most difficult regions for such measurement is from a few to 100 microns, and uses a replicator. The details of the system to automate replicator data analysis are given, together with an example case study of the system provided from a cirrus cloud in FIRE 2, with particles detectable by replicator and FSSP, but not 2DC.
This section describes our research activities during year three of this effort. In the second year, preliminary archive data sets were submitted to the SUCCESS archive. After additional analyses, final versions were prepared and submitted. These are included on the SUCCESS CD-ROM data editions that were recently released by NASA Ames. Over the range of temperature and supersaturation conditions of our measurements (15 to -40 C, and from ice saturation to approximately 15% water supersaturation), IN concentrations ranged from less than 0.1 to approximately 500 per liter, being generally greater at colder temperatures and higher supersaturations. To estimate the potential of aircraft exhaust as a source of IN, we examined data from six days of the field project when the DC-8 was following closely behind other humidity conditions of our measurements. In April 1997, a microphysical workshop was convened at NCAR to select cases for in depth analyses and to address questions about the consistency of cloud ice crystal measurements (size distributions and mass concentrations) and aerosol size distributions. We attended this meeting and contributed to the discussions. A particular concern was identified in the CN measurements. On the DC-8, CN measurements were obtained by four different investigator groups, using commercially available instrumentation. The DC-8 SUCCESS CN data showed long periods where the measurements were in substantial agreement, but there were also periods with large discrepancies. Several possible factors were identified that could help explain these discrepancies, including minimum detectable particle size, response at reduced pressures, and location of sample inlet on the aircraft.
A study was made on two commercially available terbium-doped silicate glasses. There is an increased interest in silicate glasses doped with rare-earth ions for use in high-energy particle detection and radiographic applications. These glasses are of interest due to the fact that they can be formed into small fiber sensors; a property that can be used to increase the spatial resolution of a detection system. Following absorption of radiation, the terbium ions become excited and then emit photons via 4f-4f electronic transitions as they relax back to the ground state. The lifetime of these transitions is on the order of milliseconds. A longer decay component lasting on the order of minutes has also been observed. While radiative transitions in the 4f shell of rare-earth ions are generally well understood by the Judd-Olfelt theory, the presence of a longer luminescence decay component is not. Experimental evidence that the long decay component is due, in part, to the thermal release of trapped charge carriers will be presented. In addition, a theoretical model describing the time evolution of the radiation-induced luminescence will be presented.
A study was made on two commercially available terbium-doped silicate glasses. There is an increased interest in silicate glasses doped with rare-earth ions for use in high-energy particle detection and radiographic applications. These glasses are of interest due to the fact that they can be formed into small fiber sensors; a property that can be used to increase the spatial resolution of a detection system. Following absorption of radiation, the terbium ions become excited and then emit photons via 4f-4f electronic transitions as they relax back to the ground state. The lifetime of these transitions is on the order of milliseconds. A longer decay component lasting on the order of minutes has also been observed. While radiative transitions in the 4f shell of rare-earth ions are generally well understood by the Judd-Olfelt theory, the pr'esence of a longer luminescence decay component is not. Experimental evidence that the long decay component is due, in part, to the thermal release of trapped charge carriers will be presented. In addition, a theoretical model describing the time evolution of the radiation-induced luminescence will be presented.