Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particulate matter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

NASA Lunar Dust Filtration and Separations Workshop Report

NASA Glenn Research Center hosted a 2.5-day workshop, entitled "NASA Lunar Dust Filtration and Separations Workshop" at the Ohio Aerospace Institute in Cleveland, Ohio, on November 18 to 20, 2008. The purpose of the workshop was to address the issues and challenges of particulate matter removal from the cabin atmospheres in the Altair lunar lander, lunar habitats, and in pressurized rovers. The presence of lunar regolith dust inside the pressurized volumes was a theme of particular interest. The workshop provided an opportunity for NASA, industry experts, and academia to identify and discuss the capabilities of current and developing air and gas particulate matter filtration and separations technologies as they may apply to NASA s needs. A goal of the workshop was to provide recommendations for strategic research areas in cabin atmospheric particulate matter removal and disposal technologies that will advance and/or supplement the baseline approach for these future lunar surface exploration missions.

Agui, Juan H.↗

Seasonal And Regional Differentiation Of Bio-Optical Properties Within The North Polar Atlantic

Using data collected during spring and summer seasons in the north polar Atlantic we examined the variability of the spectral absorption, a(lambda), and backscattering, b(sub b)(lambda), coefficients of surface waters and its relation to phytoplankton pigment concentration and composition. For a given chlorophyll a concentration (TChla), the concentrations of photosynthetic carotenoids (PSC), photoprotective carotenoids (PPC), and total accessory pigments (AP) were consistently lower in spring than in summer. The chlorophyll-specific absorption coefficients of phytoplankton and total particulate matter were also lower in spring, which can be partly attributed to lower proportions of PPC, PSC, and AP in spring. The spring values of the green-to-blue band ratio of the absorption coefficient were higher than the summer ratios. The blue-to-green ratios of backscattering coefficient were also higher in spring. The higher b(sub b) values and lower blue-to-green b(sub b) ratios in summer were likely associated with higher concentrations of detrital particles in summer compared to spring. Because the product of the green-to-blue absorption ratio and the blue-to-green backscattering ratio is a proxy for the blue-to-green ratio of remote-sensing reflectance, we conclude that the performance of ocean color band-ratio algorithms for estimating pigments in the north polar Atlantic is significantly affected by seasonal shifts in the relationships between absorption and TChla as well as between backscattering and TChla. Intriguingly, however, fairly good estimate of the particulate beam attenuation coefficient at 660 nm (potential measure of total particulate matter or particulate organic carbon concentration) can be obtained by applying a single blue-to-green band-ratio algorithm for both spring and summer seasons.

Stramska, Malgorzata↗

Satellite-Derived Distributions, Inventories and Fluxes of Dissolved and Particulate Organic Matter Along the Northeastern U.S. Continental Margin

Estuaries and the coastal ocean experience a high degree of variability in the composition and concentration of particulate and dissolved organic matter (DOM) as a consequence of riverine and estuarine fluxes of terrigenous DOM, sediments, detritus and nutrients into coastal waters and associated phytoplankton blooms. Our approach integrates biogeochemical measurements, optical properties and remote sensing to examine the distributions and inventories of organic carbon in the U.S. Middle Atlantic Bight and Gulf of Maine. Algorithms developed to retrieve colored DOM (CDOM), Dissolved (DOC) and Particulate Organic Carbon (POC) from NASA's MODIS-Aqua and SeaWiFS satellite sensors are applied to quantify the distributions and inventories of DOC and POC. Horizontal fluxes of DOC and POC from the continental margin to the open ocean are estimated from SeaWiFS and MODIS-Aqua distributions of DOC and POC and horizontal divergence fluxes obtained from the Northeastern North Atlantic ROMS model. SeaWiFS and MODIS imagery reveal the importance of estuarine outflow to the export of CDOM and DOC to the coastal ocean and a net community production of DOC on the shelf.

Mannino, A.↗

Investigation of Lubricant Additive Interactions on Gasoline Particulate Filters

To understand how the composition of novel lubricant additives and their ash interact with gasoline particulate filters (GPFs), an accelerated aging protocol was conducted using three lubricant additive formulations and two GPF types. The additive packages (adpaks) consisted of Ca+Mg detergent in a 3:1 or 0:1 ratio and an anti-wear component—either zinc dialkyl dithiophosphate (ZDDP) or a novel phosphonium-phosphinate ionic liquid (IL) substitute. The particulate sampling captured amount/compositions of particulate matter (PM) generated, total particulate number, and size distribution. Five ash loadings were completed. GPF position and adpak composition affected the backpressure, ash composition, ash morphology, and captured mass. The particulate sampling indicated that the ash component consisted primarily of particles less than 50 nm in size and that the Mg-only adpak resulted in more particulate of 50–400 nm in size. Postmortem materials characterization indicated GPFs in the underfloor position had deeper penetration of ash into the walls compared to the close-coupled position. Additionally, the Mg-only adpak had a higher filter collection efficiency (>90%) and the ash particles consisted of a higher concentration of dense ash material. In contrast, four of the 3:1 Ca:Mg lubricant adpaks resulted in a collection efficiency of only 40–50%. Although the collection efficiency was higher with the Mg-only adpak, the ash layer in the GPF was not thicker, nor was the penetration into the wall more significant, and surprisingly the full useful life (FUL) backpressure was lower than with Ca:Mg adpaks. The higher density of the Mg-derived ash was the only detectable difference. A possible explanation of this observation is that Mg ash has a lower melting point and is more susceptible to densification during combustion or GPF regeneration. The substitution of IL in place of the ZDDP did not lead to any notable changes in collection efficiency or location of the ash.

42 ENGINEERING↗

Effluent characterization from a conical pressurized fluid bed

To obtain useable corrosion and erosion results it was necessary to have data with several levels of particulate matter in the hot gases. One level of particulate loading was as low as possible so that ideally no erosion and only corrosion occurred. A conical fluidized bed was used to obtain some degree of filtration through the top of the bed which would not be highly fluidized. This would minimize the filtration required for the hot gases or conversely the amount of particulate matter in the hot gases after a given level of filtration by cyclones and/or filters. The data obtained during testing characterized the effluent from the bed at different test conditions. A range of bed heights, coal flows, air flows, limestone flows, and pressure are represented. These tests were made to determine the best operating conditions prior to using the bed to determine erosion and corrosion rates of typical turbine blade materials.

Priem, R. J.↗

Constructing a spatiotemporally coherent long-term PM2.5 concentration dataset over China during 1980–2019 using a machine learning approach

The lack of long-term observations and satellite retrievals of health-damaging fine particulate matter in China has demanded the estimates of historical PM 2.5 (particulate matter less than 2.5 µm in diameter) concentrations. This study constructs a gridded near-surface PM 2.5 concentration dataset across China covering 1980–2019 using the space-time random forest model with atmospheric visibility observations and other auxiliary data. The modeled daily PM2.5 concentrations are in excellent agreement with ground measurements during 2015–2019, with a coefficient of determination of 0.95 and mean relative error of 12%. Besides the atmospheric visibility which explains 30% of total importance of variables in the model, both emissions and meteorological conditions are also essential factors affecting PM2.5 predictions. From 1980 to 2014, the model-predicted PM2.5 concentrations increased constantly with the maximum growth rate of 5–10 µg/m3/decade over eastern China. Due to the clean air actions, PM 2.5 concentrations have decreased effectively at a rate over 50 µg/m 3 /decade in the North China Plain and 20–50 µg/m 3 /decade over eastern China during 2014–2019. The newly generated dataset of 1-degree gridded PM 2.5 concentrations for the past 40 years across China provides a useful means for investigating interannual and decadal environmental and climate impacts related to aerosols.

54 ENVIRONMENTAL SCIENCES↗

Estimating Vertical Diffusion Coefficients By Lidar

The Atmospheric Turbulence and Diffusion Laboratory at Oak Ridge, Tennessee has been conducting routine probing of the lower troposphere and comparing the results with those obtained with turbidity photometers and a distant suspended particulate station. The change in scale height, K (sub z) divided by v (sub s), with time permits the vertical turbulence coefficient K (sub z) to be estimated if v (sub s) is known or assumed. Extremely high monthly correlations of turbidity versus the log of backscatter at 100 meters have been obtained. In addition, high correlations of suspended particulate matter at Chattanooga and Oak Ridge suggest that the bulk of particulate matter is of natural, rather than industrial, origin.

Culkowski, Walter M.↗

Cooled Spray Technology for Particulate Reduction in a Heavy-Duty Engine

Cooled spray (CS) technology passively reduces particulate matter (PM) emissions from diesel engines compared to non-CS-equipped diesel engines. CS inserts are mounted near the injector nozzle and control mixing so that the fuel and air can premix while limiting combustion near fuel-rich zones, thereby reducing the formation of particulate matter. CS components contain no moving parts and could be installed as a retrofit or built into new engines. However, CS technology is early in its development, and further investigations are needed to understand the overall performance implications and practicality of the technology. In this paper, we investigate several important aspects of CS, providing a clearer picture of some challenges and potential benefits of CS. Two alignment techniques are used to characterize measurement ease and bias, namely, an optical alignment and spray-plug impact alignment. While the optical technique facilitates alignment more easily, a bias was measured between the optical and spray-plug techniques, suggesting the optical technique may have insufficient accuracy without additional corrections. We also evaluate the engine performance of a well-aligned and poorly aligned CS insert, compared to the baseline configuration. The poorly aligned insert shows slower combustion than the baseline and mixed overall performance. However, the well-aligned insert shows faster combustion than the baseline and PM emission reduction at most operating conditions, with some conditions showing PM reduction up to 80%. Furthermore, the results of this paper highlight the alignment challenges of CS technology as well as the potential PM reduction benefit of the technology.

33 ADVANCED PROPULSION SYSTEMS↗

Biochemical Conversion of Herbaceous Biomass to Renewable Diesel: Net Greenhouse Gas and Air Pollutant Trade-offs

This study examines greenhouse gas (GHG) and criteria air pollutant (CAP) emissions trade-offs for renewable diesel across 12 scenarios, involving different biochemical conversion designs, biorefinery scales, and feedstocks. A conventional design uses lignin for on-site heat and power, which exports excess power to the grid. An alternative design exports lignin pellets, offsetting other pellet production methods but requiring grid electricity to meet biorefinery power demands. Net emissions were quantified in Iowa and Georgia, selected considering feedstock availability, coproduct displacement, and regional power grids, assuming grid-exported power avoids coal or low-carbon electricity. Results for the conventional design remained consistent across the electricity displacement scenarios. When comparing lignin utilization strategies, pelletizing lignin reduces sulfur dioxide, carbon monoxide, nitrogen oxides, and volatile organic compounds (net emissions –0.66 mg MJ –1 , 25 mg MJ –1 , 25 mg MJ –1 , 7.8 mg MJ –1 , respectively). However, lignin pelletization increases net particulate matter (fine and coarse) and ammonia (net emissions of 4.7 mg MJ –1 , 13 mg MJ –1 , and 0.26 mg MJ –1 , respectively), alongside indirect GHG emissions due to grid electricity dependence. Additionally, processing 2000 tonnes corn stover daily minimizes emissions for both designs. Only lignin pelletization with renewable electricity and additional particulate matter and ammonia controls reduces all CAP and GHG emissions simultaneously.

09 BIOMASS FUELS↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Historical and Future Changes in Air Pollutants from CMIP6 Models

Poor air quality is currently responsible for large impacts on human health across the world. In addition, the air pollutants ozone (O3) and particulate matter less than 2.5 µm in diameter (PM2.5) are also radiatively active in the atmosphere and can influence Earth's climate. It is important to understand the effect of air quality and climate mitigation measures over the historical period and in different future scenarios to ascertain any impacts from air pollutants on both climate and human health. The Coupled Model Intercomparison Project Phase 6 (CMIP6) presents an opportunity to analyse the change in air pollutants simulated by the current generation of climate and Earth system models that include a representation of chemistry and aerosols (particulate matter). The shared socio-economic pathways (SSPs) used within CMIP6 encompass a wide range of trajectories in precursor emissions and climate change, allowing for an improved analysis of future changes to air pollutants. Firstly, we conduct an evaluation of the available CMIP6 models against surface observations of O3 and PM2.5. CMIP6 models consistently overestimate observed surface O3 concentrations across most regions and in most seasons by up to 16 ppb, with a large diversity in simulated values over Northern Hemisphere continental regions. Conversely, observed surface PM2.5 concentrations are consistently underestimated in CMIP6 models by up to 10 µg m−3, particularly for the Northern Hemisphere winter months, with the largest model diversity near natural emission source regions. The biases in CMIP6 models when compared to observations of O3 and PM2.5 are similar to those found in previous studies. Over the historical period (1850–2014) large increases in both surface O3 and PM2.5 are simulated by the CMIP6 models across all regions, particularly over the mid to late 20th century, when anthropogenic emissions increase markedly. Large regional historical changes are simulated for both pollutants across East and South Asia with an annual mean increase of up to 40 ppb for O3 and 12 µg m−3 for PM2.5. In future scenarios containing strong air quality and climate mitigation measures (ssp126), annual mean concentrations of air pollutants are substantially reduced across all regions by up to 15 ppb for O3 and 12 µg m−3 for PM2.5. However, for scenarios that encompass weak action on mitigating climate and reducing air pollutant emissions (ssp370), annual mean increases in both surface O3 (up 10 ppb) and PM2.5 (up to 8 µg m−3) are simulated across most regions, although, for regions like North America and Europe small reductions in PM2.5 are simulated due to the regional reduction in precursor emissions in this scenario. A comparison of simulated regional changes in both surface O3 and PM2.5 from individual CMIP6 models highlights important regional differences due to the simulated interaction of aerosols, chemistry, climate and natural emission sources within models. The projection of regional air pollutant concentrations from the latest climate and Earth system models used within CMIP6 shows that the particular future trajectory of climate and air quality mitigation measures could have important consequences for regional air quality, human health and near-term climate. Differences between individual models emphasise the importance of understanding how future Earth system feedbacks influence natural emission sources, e.g. response of biogenic emissions under climate change.

Air pollutants↗

Ambient Aerosol Is Physically Larger on Cloudy Days in Bondville, Illinois

Particle chemical composition affects aerosol optical and physical properties in ways important for the fate, transport, and impact of atmospheric particulate matter. For example, hygroscopic constituents take up water to increase the physical size of a particle, which can alter the extinction properties and atmospheric lifetime. At the collocated AERosol RObotic NETwork (AERONET) and Interagency Monitoring of PROtected Visual Environments (IMPROVE) network monitoring stations in rural Bondville, Illinois, we employ a novel cloudiness determination method to compare measured aerosol physicochemical properties on predominantly cloudy and clear sky days from 2010 to 2019. On cloudy days, aerosol optical depth (AOD) is significantly higher than on clear sky days in all seasons. Measured angstrom ngstro''m exponents are significantly smaller on cloudy days, indicating physically larger average particle size for the sampled populations in all seasons except winter. Mass concentrations of fine particulate matter that include estimates of aerosol liquid water (ALW) are higher on cloudy days in all seasons but winter. More ALW on cloudy days is consistent with larger particle sizes inferred from angstrom ngstro''m exponent measurements. Aerosol chemical composition that affects hygroscopicity plays a determining impact on cloudy versus clear sky differences in AOD, angstrom ngstro''m exponents, and ALW. This work highlights the need for simultaneous collocated, high-time-resolution measurements of both aerosol chemical and physical properties, in particular at cloudy times when quantitative understanding of tropospheric composition is most uncertain.

54 ENVIRONMENTAL SCIENCES↗

The Sensitivity of the Equatorial Pacific ODZ to Particulate Organic Matter Remineralization in A Climate Model Under Pre-Industrial Conditions

Marine oxygen plays a fundamental role in regulating the transfer of organic carbon and nutrients to their dissolved inorganic forms, serving as the terminal electron acceptor for heterotrophic respiration. Oxygen can become limiting to these processes in coastal and open-ocean oxygen deficient zones (ODZs). The maintenance of ODZs depends on the balance between physical processes such as ventilation and biogeochemical processes such as remineralization. These two processes act in opposing directions on ODZs, with ventilation responsible for transporting oxygen from the surface, where it is near saturation with the partial pressure of O2 in the atmosphere, to deeper oxygen-depleted layers, and remineralization acting to consume oxygen through biogeochemical processes such as microbial degradation throughout the water column. Remineralization is represented in all CMIP6 models, but the actual parameterizations, as well as their magnitude, are widely varying. In this study, we examine the sensitivity to remineralization of the equatorial Pacific ODZ O2 ol/kg) in a model; the NASA GISS Ocean Biogeochemical Model (NOBM-G) embedded in the NASA-GISS coupled atmosphere-ocean model. We find that increasing the remineralization rate shoals the ODZ onset depth (i.e. the regionally averaged upper bound of the ODZ), and decreases ODZ volume and regional-averaged thickness. Changes in biological consumption and vertical convergence of oxygen are identified as the primary contributors to changes in ODZ onset depth. ODZ thickness is mainly influenced by the shoaling of the bottom boundary of the ODZ, which decreases with maximum remineralization rate due to decreasing oxygen consumption and increasing horizontal oxygen convergence in deep waters. On the other hand, vertically-averaged ODZ area has a more complex, non-monotonic relationship with maximum remineralization rate. While these findings suggest an important role for remineralization in determining the shape of the ODZ in our model, the relative importance of remineralization vs. other physical parameterizations remains to be established. While our results reflect the structure of our ocean biogeochemical model, the relationship of remineralization to ODZ characteristics in other models should be examined to better inform model inter-comparisons.

Oxygen-deficient zone↗

Significant Atmospheric Aerosol Pollution Caused by World Food Cultivation

Particulate matter is a major concern for public health, causing cancer and cardiopulmonary mortality. Therefore, governments in most industrialized countries monitor and set limits for particulate matter. To assist policy makers, it is important to connect the chemical composition and severity of particulate pollution to its sources. Here we show how agricultural practices, livestock production, and the use of nitrogen fertilizers impact near-surface air quality. In many densely populated areas, aerosols formed from gases that are released by fertilizer application and animal husbandry dominate over the combined contributions from all other anthropogenic pollution. Here we test reduction scenarios of combustion-based and agricultural emissions that could lower air pollution. For a future scenario, we find opposite trends, decreasing nitrate aerosol formation near the surface while total tropospheric loads increase. This suggests that food production could be increased to match the growing global population without sacrificing air quality if combustion emission is decreased.

public health↗

A14H-04 Analysis of Simulated and Observed Trends in Global Surface PM2.5 and Aerosol Optical Properties from 1958 to 2018 Using the NASA GEOSCCM

Modeling of long-term trends of aerosols and their properties is important for constraining aerosol-climate forcing, and for characterizing changes in particulate matter pollution speciation and exposure. Here we study global and regional long-term trends in surface fine particulate matter (PM ) and aerosol optical properties for 60 years from 1958 to 2018, using simulations performed with the NASA Goddard Earth Observing System Chemistry Climate Model (GEOSCCM), and evaluate the model hindcast with observations for the last three decades. Comparing the modeled aerosols with a diverse set of observations helps interpret observed and simulated trends, and serves as a benchmark for future GEOSCCM developments and input datasets improvements. We first characterize modeled global and regional temporal changes in surface PM and its components, aerosol optical depth (AOD) and single scattering albedo (SSA) and we interpret their link with emissions drivers. We then compare modeled surface PM with ground-based observations from monitoring networks and with global reconstructed PM datasets from observations-model data fusion. Total AOD is compared with long-term satellite measurements from the Moderate Resolution Imaging Spectroradiometer (MODIS) and measurements from the ground-based Aerosol Robotic Network (AERONET). Additional aerosol optical properties, such as absorption and scattering coefficients, are evaluated with ground-based observations from the Global Atmosphere Watch (GAW) records.

aerosols↗

A Laboratory Comparison of a Nephelometer and the Cavity-Attenuated Phase Shift Instrument (CAPS)

The interaction of incoming solar radiation (light) with particulate matter in the atmosphere impacts Earth’s radiation budget and thus is of great importance to climate and climate change. This particulate matter consists of particles, an aerosol referring to the ensemble of these particles. All particles scatter incoming solar radiation, sending some of it back to space and providing a cooling influence on the climate. Some particles additionally absorb incoming solar radiation, causing the particle, and the surrounding atmosphere, to heat, and thus altering atmospheric stability and evaporating water and other substances in the particles, which in turn affect the scattering and absorption of light by the particle.

54 ENVIRONMENTAL SCIENCES↗

NASA's GEOS Composition Model Assessment of PM2.5 During Wildfires: Inferring the Impact of PM2.5 Exposure on Adverse Respiratory & Cardiovascular Conditions

Particulate matter pollution is a mixture of solid and liquid droplets floating in the air that can lead to reduced air quality and increased adverse health impact. Fine particulate matter (PM2.5) can be emitted into the air from anthropogenic sources such as the burning of fossil fuels, motor vehicles, and powerplant emissions. Exposure to PM2.5 can aggravate pre-existing respiratory and cardiovascular conditions. When PM2.5 is inhaled it can cause damage to the lungs such as reduced lung function and shortness of breath. After being inhaled PM2.5 can enter the bloodstream and cause harm to the heart. One major natural source of PM2.5 exposure is from wildfire smoke. The particulates within the smoke from the wildfires can spread from the initial source region, potentially impacting communities both near and far. During and after wildfire events, PM2.5 levels can exceed the WHO air quality guidelines (10 m.g/m^3 annual mean; 25 m.g/m^3 daily mean), becoming hazardous to an individual's health. Global models can be used to simulate the emission and transport of these particulates and subsequently they can be valuable to air quality forecasting in highly polluted areas. The NASA Goddard Earth Observing System (GEOS) Composition Forecast (GEOS-CF) system has been used to produce near-real time air quality forecasts of atmospheric composition at a high global resolution of 25x25 km2. The GEOS-CF system utilizes the GEOS weather forecast model coupled with GEOS-Chem (version 11) chemistry module to provide analyses and forecasts of various toxic air pollutants, including PM2.5. The GEOS-CF simulated high levels of PM2.5 (40 m.g/m^3 to 250 m.g/m^3 ), exceeding the WHO guidelines, during multiple recent regional and global wildfire seasons, including the 2017 Washington State and Northern and Southern California wildfire seasons. Furthermore, the GEOS-CF simulated PM2.5 applied to a human health assessment model, BenMAP (The Environmental Benefits Mapping and Analysis Program, version 1.3), estimates the impact on adverse respiratory health conditions due to PM2.5 exposure from wildfires. The GEOS-CF predicted PM2.5 during the wildfire season with the corresponding BenMAP results provides an assessment of the human health impact of PM2.5 exposure.

Saunders, Emily↗