Search NASA⌕ Search

SEARCH · Search NASA

Results for “Patient Support System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-T-434: Fixed Margin Or Online Adaptation for Intermediate-Risk Prostate Stereotactic Body Radiation Therapy? A Dosimetric Study

Purpose: To investigate the choice of fixed margin or online adaptation when treating intermediate-risk prostate cancer including seminal vesicles (SV) using stereotactic body radiation therapy (SBRT). Methods: 9 prostate SBRT patients were retrospectively studied. All patients were implanted with fiducial markers in the prostate for daily localization and verification. Each patient had 5 pairs of pre-treatment and post-treatment cone-beam CT (CBCT) per protocol. SVs were contoured on planning CT and all CBCTs by one attending physician. Simultaneous integral boost (SIB) IMRT plans were developed to deliver 25Gy/5fx to the SV while delivering 37Gy/5fx to the prostate. A 3mm isotropic margin was added to the prostate while a 5 mm isotropic margin was used for the SV. The planning CT was registered to daily pre-treatment and post-treatment CBCT based on fiducial markers in the prostate to mimic online prostate localization; and the SV on daily CBCT was transferred to the CT structure set after the prostates were aligned. Daily pre-treatment and post-treatment SV dose coverage and the organ-at-risk (OAR) sparing were evaluated for the SIB regimen. At least 95% of the SV need to receive the prescription dose (5Gy per fraction). Results: For the total of 90 daily SVs analyzed (ten CBCTs for each of nine patients), only 45 daily SVs (50%) were able to meet the coverage that 95% of the SV received 25Gy. The OAR sparing performance was acceptable for most of the dosimetric constraints in low-risk prostate SBRT protocol with only two exceptions in bladder V100 (cc). Conclusion: A fixed 5mm margin for SV is not sufficient to provide consistent daily dose coverage due to SV’s substantial inter- and intra-fractional motion relative to the prostate. This finding calls for innovative strategies in margin design as well as online treatment adaptation. This work is partially supported a master research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-E-03: Developing Solutions to Critical Radiation Oncology Challenges in Tanzania

Purpose: Develop solutions to critical medical physics challenges in Tanzania. Methods: In September of 2013 we began working with Jumaa Bin Dachi, a Therapy Physicist at the Ocean Road Cancer Institute in Dar es Salaam, Tanzania. We developed a bi-lateral learning partnership over the course of eight qualitative Skype meetings with Jumaa. From these meetings we have ascertained that there is a gap between the installation of new equipment and treating patients. This gap has often been overlooked by international partners attempting to improve radiation therapy access. Relationships with academic institutions abroad can fill these gaps, and lead to sustained care of patients needing radiation. Results: Our efforts are best given in a supporting role to help develop solutions and new technology that can reduce the burden on the Medical Physicist. Solutions may include: training material, support for radiation therapy classes, development of appropriate local protocols, and peer-review on documents being produced. New technology needs to focus around simple and easy field shaping, improved patient imaging systems, and systems for patient set-up. We believe our work can help alleviate some of the burdens faced by this institute. Conclusion: While we are just in the beginning stage of this partnership, we believe there is great potential for success between both parties. We hope that the Ocean Road Cancer Institute will benefit from potential funding and resources by partnering with a High Income Country to develop affordable solutions to clinical problems in Tanzania.

60 APPLIED LIFE SCIENCES↗

User and Task Analysis of the Flight Surgeon Console at the Mission Control Center of the NASA Johnson Space Center

Astronauts in a space station are to some extent like patients in an intensive care unit (ICU). Medical support of a mission crew will require acquisition, transmission, distribution, integration, and archiving of significant amounts of data. These data are acquired by disparate systems and will require timely, reliable, and secure distribution to different communities for the execution of various tasks of space missions. The goal of the Comprehensive Medical Information System (CMIS) Project at Johnson Space Center Flight Medical Clinic is to integrate data from all Medical Operations sources, including the reference information sources and the electronic medical records of astronauts. A first step toward the full CMIS implementation is to integrate and organize the reference information sources and the electronic medical record with the Flight Surgeons console. In order to investigate this integration, we need to understand the usability problems of the Flight Surgeon's console in particular and medical information systems in general. One way to achieve this understanding is through the use of user and task analyses whose general purpose is to ensure that only the necessary and sufficient task features that match users capacities will be included in system implementations. The goal of this summer project was to conduct user and task analyses employing cognitive engineering techniques to analyze the task of the Flight Surgeons and Biomedical Engineers (BMEs) while they worked on Console. The techniques employed were user interviews, observations and a questionnaire to collect data for which a hierarchical task analysis and an information resource assessment were performed. They are described in more detail below. Finally, based on our analyses, we make recommendations for improvements to the support structure.

Johnson, Kathy A.↗

SU-C-BRD-06: Results From a 5 Patient in Vivo Rectal Wall Dosimetry Study Using Plastic Scintillation Detectors

Purpose: To evaluate the performance characteristics of plastic scintillation detectors (PSDs) in an in vivo environment for external beam radiation, and to establish the usefulness and ease of implementation of a PSD based in vivo dosimetry system for routine clinical use. Methods: A five patient IRB approved in vivo dosimetry study was performed. Five patients with prostate cancer were enrolled and PSDs were used to monitor rectal wall dose and verify the delivered dose for approximately two fractions each week over the course of their treatment (approximately fourteen fractions), resulting in a total of 142 in vivo measurements. A set of two PSDs was fabricated for each patient. At each monitored fraction the PSDs were attached to the anterior surface of an endorectal balloon used to immobilize the patient's prostate during treatment. A CT scan was acquired with a CTon- rails linear accelerator to localize the detectors and to calculate the dose expected to be delivered to the detectors. Each PSD acquired data in 10 second intervals for the duration of the treatment. The deviation between expected and measured cumulative dose was calculated for each detector for each fraction, and averaged over each patient and the patient population as a whole. Results: The average difference between expected dose and measured dose ranged from -3.3% to 3.3% for individual patients, with standard deviations between 5.6% and 7.1% for four of the patients. The average difference for the entire population was -0.4% with a standard deviation of 2.8%. The detectors were well tolerated by the patients and the system did not interrupt the clinical workflow. Conclusion: PSDs perform well as in vivo dosimeters, exhibiting good accuracy and precision. This, combined with the practicability of using such a system, positions the PSD as a strong candidate for clinical in vivo dosimetry in the future. This work supported in part by the National Cancer Institute through an R01 grant (CA120198-01A2) and by the American Legion Auxiliary through the American Auxiliary Fellowship in Cancer Research.

60 APPLIED LIFE SCIENCES↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗

Automated Segmentation and Quantification of Drusen in Fundus and Optical Coherence Tomography Images for Detection of ARMD

Age-related macular degeneration (ARMD) is one of the most common retinal syndromes that occurs in elderly people. Different eye testing techniques such as fundus photography and optical coherence tomography (OCT) are used to clinically examine the ARMD-affected patients. Many researchers have worked on detecting ARMD from fundus images, few of them also worked on detecting ARMD from OCT images. However, there are only few systems that establish the correspondence between fundus and OCT images to give an accurate prediction of ARMD pathology. In this paper, we present fully automated decision support system that can automatically detect ARMD by establishing correspondence between OCT and fundus imagery. The proposed system also distinguishes between early, suspect and confirmed ARMD by correlating OCT B-scans with respective region of the fundus image. In first phase, proposed system uses different B-scan based features along with support vector machine (SVM) to detect the presence of drusens and classify it as ARMD or normal case. In case input OCT scan is classified as ARMD, region of interest from corresponding fundus image is considered for further evaluation. The analysis of fundus image is performed using contrast enhancement and adaptive thresholding to detect possible drusens from fundus image and proposed system finally classified it as early stage ARMD or advance stage ARMD. The proposed system is tested on local data set of 100 patients with100 fundus images and 6800 OCT B-scans. Proposed system detects ARMD with the accuracy, sensitivity, and specificity ratings of 98.0, 100, and 97.14%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Establishing Evidence-Based Indications for Proton Therapy: An Overview of Current Clinical Trials

Purpose: To review and assess ongoing proton beam therapy (PBT) clinical trials and to identify major gaps. Methods and Materials: Active PBT clinical trials were identified from (clinicaltrials.gov) and the World Health Organization International Clinical Trials Platform Registry. Data on clinical trial disease site, age group, projected patient enrollment, expected start and end dates, study type, and funding source were extracted. Results: A total of 122 active PBT clinical trials were identified, with target enrollment of >42,000 patients worldwide. Ninety-six trials (79%), with a median planned sample size of 68, were classified as interventional studies. Observational studies accounted for 21% of trials but 71% (n=29,852) of planned patient enrollment. The most common PBT clinical trials focus on gastrointestinal tract tumors (21%, n=26), tumors of the central nervous system (15%, n=18), and prostate cancer (12%, n=15). Five active studies (lung, esophagus, head and neck, prostate, breast) will randomize patients between protons and photons, and 3 will randomize patients between protons and carbon ion therapy. Conclusions: The PBT clinical trial portfolio is expanding rapidly. Although the majority of ongoing studies are interventional, the majority of patients will be accrued to observational studies. Future efforts should focus on strategies to encourage optimal patient enrollment and retention, with an emphasis on randomized, controlled trials, which will require support from third-party payers. Results of ongoing PBT studies should be evaluated in terms of comparative effectiveness, as well as incremental effectiveness and value offered by PBT in comparison with conventional radiation modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

60 APPLIED LIFE SCIENCES↗

3D treatment planning on helical tomotherapy delivery system

The helical tomotherapy is a technologically advanced radiation dose delivery system designed to perform intensity-modulated radiation therapy (IMRT). It is mechanistically unique, based on a small 6-MV linear accelerator mounted on a ring gantry that rotates around the patient while the patient moves through a bore, ultimately yielding a helical path of radiation dose delivery. The helical pattern of dose delivery differentiated tomotherapy from other contemporary radiation therapy systems at the time of its inception. The accompanying 3-dimensional (3D) treatment planning system has been developed to solely support this specific type of dose delivery system. The treatment planning system has 2 modules identified as TomoHelical and TomoDirect to perform IMRT and conformal radiation therapy, respectively. The focus of this work within the scope of this special issue on 3D treatment planning systems is to assess the use of planning tools to generate treatment plans for helical tomotherapy. Clinical examples are used throughout to demonstrate the quality and differences of various clinical scenarios planned with tomotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simplified Readability Metric Drives Improvement of Radiology Reports: an Experiment on Ultrasound Reports at a Pediatric Hospital

Highly complex medical documents, including ultrasound reports, are greatly mismatched with patient literacy levels. While improving radiology reports for readability is a longstanding concern, few articles objectively measure the effectiveness of physician training for readability improvement. We hypothesized that writing styles may be evaluated using an objective two-dimensional measure and writing training could improve the writing styles of radiologists. To test it, a simplified “grade vs. length” readability metric is developed based on results from factor analysis of ten readability metrics applied to more than 500,000 radiology reports. To test the short-term effectiveness of a writing workshop, we measured the writing style improvement before and after the training. Statistically significant writing style improvement occurred as a result of the training. Although the degree of improvement varied for different measures, it is evident that targeted training could provide potential benefits to improve readability due to our statistically significant results. The simplified grade vs. length metric enables future clinical decision support systems to quantitatively guide physicians to improve writing styles through writing workshops.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Regeneration of Tissues and Organs Using Autologous Cells

The Joint Commission for Health Care Organizations recently declared the shortage of transplantable organs and tissues a public health crisis. As such, there is about one death every 30 seconds due to organ failure. Complications and rejection are still significant albeit underappreciated problems. It is often overlooked that organ transplantation results in the patient being placed on an immune suppression regimen that will ultimate shorten their life span. Patients facing reconstruction often find that surgery is difficult or impossible due to the shortage of healthy autologous tissue. In many cases, autografting is a compromise between the condition and the cure that can result in substantial diminution of quality of life. The national cost of caring for persons who might benefit from engineered tissues or organs has reached $600 billion annually. Autologous tissue technologies have been developed as an alternative to transplantation or reconstructive surgery. Autologous tissues derived from the patient's own cells are capable of correcting numerous pathologies and injuries. The use of autologous cells eliminates the risks of rejection and immunological reactions, drastically reduces the time that patients must wait for lifesaving surgery, and negates the need for autologous tissue harvest, thereby eliminating the associated morbidities. In fact, the use of autologous tissues to create functional organs is one of the most important and groundbreaking steps ever taken in medicine. Although the basic premise of creating tissues in the laboratory has progressed dramatically, only a limited number of tissue developments have reached the patients to date. This is due, in part, to the several major technological challenges that require solutions. To that end, we have been in pursuit of more efficient ways to expand cells in vitro, methods to improve vascular support so that relevant volumes of engineered tissues can be grown, and constructs that can mimic the native tissue environment to ensure tissue integration, maturation, and survival. Other long-term benefits of this research are likely to be cell-based drug delivery mechanisms, intelligent biomaterials, bio-nano technologies, as well as controlled delivery using advances in materials science. The major challenges to the goal of producing tissues and organs for transplantation and reconstruction are three-fold and will form the basis for the goals of this research. These include (1) Identifying sources of autologous cells and developing methods to expand them in large number in vitro, (2) Providing vascular support for growing constructs, and (3) Developing biomaterials and bioreactor systems that mimic the native tissue environment.

36 MATERIALS SCIENCE↗

Gait Characterization and Analysis of Hereditary Amyloidosis Associated with Transthyretin Patients: A Case Series

Hereditary amyloidosis associated with transthyretin (ATTRv), is a rare autosomal dominant disease characterized by length-dependent symmetric polyneuropathy that has gait impairment as one of its consequences. The gait pattern of V30M ATTRv amyloidosis patients has been described as similar to that of diabetic neuropathy, associated with steppage, but has never been quantitatively characterized. In this study we aim to characterize the gait pattern of patients with V30M ATTRv amyloidosis, thus providing information for a better understanding and potential for supporting diagnosis and disease progression evaluation. We present a case series in which we conducted two gait analyses, 18 months apart, of five V30M ATTRv amyloidosis patients using a 12-camera, marker based, optical system as well as six force platforms. Linear kinematics, ground reaction forces, and angular kinematics results are analyzed for all patients. All patients, except one, showed a delayed toe-off in the second assessment, as well as excessive pelvic rotation, hip extension and external transverse rotation and knee flexion (in stance and swing phases), along with reduced vertical and mediolateral ground reaction forces. The described gait anomalies are not clinically quantified; thus, gait analysis may contribute to the assessment of possible disease progression along with the clinical evaluation.

Vilas-Boas, Maria do Carmo (ORCID:000000025012789X↗

SU-E-J-66: Significant Anatomical and Dosimetric Changes Observed with the Pharyngeal Constrictor During Head and Neck Radiotherapy Elicited From Daily Deformable Image Registration and Dose Accumulation

Purpose: To evaluate the anatomical changes and associated dosimetric consequences to the pharyngeal constrictor (PC) that occurs during head and neck radiotherapy (H&N RT). Methods: A cohort of 13 oro-pharyngeal cancer patients, who had daily CBCT’s for localization, was retrospectively studied. On every 5th CBCT, PC was manually delineated by a radiation oncologist. The anterior-posterior PC thickness was measured at the C3 level. Delivered dose to PC was estimated by calculating daily doses on CBCT’s, and accumulating to corresponding planning CT images. For accumulation, a parameter-optimized B- spline-based deformable image registration algorithm (Elastix) was used, in conjunction with an energy-mass mapping dose transfer algorithm. Mean and maximum dose (Dmean, Dmax) to PC was determined and compared with corresponding planned quantities. Results: The mean (±standard deviation) volume increase (ΔV) and thickness increase (Δt) over the course of 35 total fractions were 54±33% (11.9±7.6 cc), and 63±39% (2.9±1.9 mm), respectively. The resultant cumulative mean dose increase from planned dose to PC (ΔDmean) was 1.4±1.3% (0.9±0.8 Gy), while the maximum dose increase (ΔDmax) was 0.0±1.6% (0.0±1.1 Gy). Patients with adaptive replanning (n=6) showed a smaller mean dose increase than those without (n=7); 0.5±0.2% (0.3±0.1 Gy) vs. 2.2±1.4% (1.4±0.9 Gy). There was a statistically significant (p<0.0001) strong correlation between ΔDmean and Δt (Pearson coefficient r=0.78), and a moderate-to-strong correlation (r=0.52) between ΔDmean and ΔV. Correlation between ΔDmean and weight loss ΔW (r=0.1), as well as ΔV and ΔW (r=0.2) were negligible. Conclusion: Patients were found to undergo considerable anatomical changes to pharyngeal constrictor during H&N RT, resulting in non-negligible dose deviations from intended dose. Results are indicative that pharyngeal constrictor thickness, measured at C3 level, is a good predictor for the dose change to the organ. Daily deformable registration and dose accumulation provide a reliable means to assess important anatomical and dosimetric changes to pharyngeal constrictor occurring during treatment. This work was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Distal Embolic Protection for Renal Arterial Interventions

Distal or embolic protection has intuitive appeal for its potential to prevent embolization of materials generated during interventional procedures. Distal protection devices (DPDs) have been most widely used in the coronary and carotid vascular beds, where they have demonstrated the ability to trap embolic materials and, in some cases, to reduce complications. Given the frequency of chronic kidney disease in patients with renal artery stenosis undergoing stent placement, it is reasonable to propose that these devices may play an important role in limiting distal embolization in the renal vasculature. Careful review of the literature reveals that atheroembolization does occur during renal arterial interventions, although it often goes undetected. Early experience with DPDs in the renal arteries in patients with suitable anatomy suggests retrieval of embolic materials in approximately 71% of cases and renal functional improvement/stabilization in 98% of cases. The combination of platelet inhibition and a DPD may provide even greater benefit. Given the critical importance of renal functional preservation, it follows that everything that can be done to prevent atheroembolism should be undertaken including the use of DPDs when anatomically feasible. The data available at this time support a beneficial role for these devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-257: A PCA Model to Predict Adaptive Changes for Head&neck Patients Based On Extraction of Geometric Features From Daily CBCT Datasets

Purpose: Using daily cone beam CTs (CBCTs) to develop principal component analysis (PCA) models of anatomical changes in head and neck (H&N) patients and to assess the possibility of using these prospectively in adaptive radiation therapy (ART). Methods: Planning CT (pCT) images of 4 H&N patients were deformed to model several different systematic changes in patient anatomy during the course of the radiation therapy (RT). A Pinnacle plugin was used to linearly interpolate the systematic change in patient for the 35 fraction RT course and to generate a set of 35 synthetic CBCTs. Each synthetic CBCT represents the systematic change in patient anatomy for each fraction. Deformation vector fields (DVFs) were acquired between the pCT and synthetic CBCTs with random fraction-to-fraction changes were superimposed on the DVFs. A patient-specific PCA model was built using these DVFs containing systematic plus random changes. It was hypothesized that resulting eigenDVFs (EDVFs) with largest eigenvalues represent the major anatomical deformations during the course of treatment. Results: For all 4 patients, the PCA model provided different results depending on the type and size of systematic change in patient’s body. PCA was more successful in capturing the systematic changes early in the treatment course when these were of a larger scale with respect to the random fraction-to-fraction changes in patient’s anatomy. For smaller scale systematic changes, random changes in patient could completely “hide” the systematic change. Conclusion: The leading EDVF from the patientspecific PCA models could tentatively be identified as a major systematic change during treatment if the systematic change is large enough with respect to random fraction-to-fraction changes. Otherwise, leading EDVF could not represent systematic changes reliably. This work is expected to facilitate development of population-based PCA models that can be used to prospectively identify significant anatomical changes early in treatment. This work is supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-E-J-224: Multimodality Segmentation of Head and Neck Tumors

Purpose: Develop an algorithm that is able to automatically segment tumor volume in Head and Neck cancer by integrating information from CT, PET and MR imaging simultaneously. Methods: Twenty three patients that were recruited under an adaptive radiotherapy protocol had MR, CT and PET/CT scans within 2 months prior to start of radiotherapy. The patients had unresectable disease and were treated either with chemoradiotherapy or radiation therapy alone. Using the Velocity software, the PET/CT and MR (T1 weighted+contrast) scans were registered to the planning CT using deformable and rigid registration respectively. The PET and MR images were then resampled according to the registration to match the planning CT. The resampled images, together with the planning CT, were fed into a multi-channel segmentation algorithm, which is based on Gaussian mixture models and solved with the expectation-maximization algorithm and Markov random fields. A rectangular region of interest (ROI) was manually placed to identify the tumor area and facilitate the segmentation process. The auto-segmented tumor contours were compared with the gross tumor volume (GTV) manually defined by the physician. The volume difference and Dice similarity coefficient (DSC) between the manual and autosegmented GTV contours were calculated as the quantitative evaluation metrics. Results: The multimodality segmentation algorithm was applied to all 23 patients. The volumes of the auto-segmented GTV ranged from 18.4cc to 32.8cc. The average (range) volume difference between the manual and auto-segmented GTV was −42% (−32.8%–63.8%). The average DSC value was 0.62, ranging from 0.39 to 0.78. Conclusion: An algorithm for the automated definition of tumor volume using multiple imaging modalities simultaneously was successfully developed and implemented for Head and Neck cancer. This development along with more accurate registration algorithms can aid physicians in the efforts to interpret the multitude of imaging information available in radiotherapy today. This project was supported by a grant by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-632: A Dosimetric Comparison of the 3D-CRT Planning of Chest Wall in Post-Mastectomy Breast Cancer Patients, with and Without Breast Board Setup

Purpose: Breast boards are used in breast radiation which increases normal lung and heart doses, when supraclavicular field is included. Therefore, in this study through dose volume histogram (DVHs), lung and heart doses comparison was done between two different setups i.e. with and without breast board, for the treatment of left chest wall and supraclavicular fossa in postmastectomy left breast cancer. Methods: In this study, CT-Simulation scans of ten breast cancer patients were done with and without breast board, at Shifa International Hospitals Islamabad, to investigate the differences between the two different setups of the irradiation of left chest wall in terms of lung and heart doses. For immobilization, support under the neck, shoulders and arms was used. Precise PLAN 2.15 treatment planning system (TPS) was used for 3D-CRT planning. The total prescribed dose for both the plans was 5000 cGy/25 fractions. The chest wall was treated with a pair of tangential photon fields and the upper supraclavicular nodal regions were treated with an anterior photon field. A mono-isocentric technique was used to match the tangential fields with the anterior field at the isocentre. The dose volume histogram was used to compare the doses of heart and ipsilateral lung. Results: Both the plans of each patient were generated and compared. DVH results showed that for the same PTV dose coverage, plans without breast board resulted in a reduction of lung and heart doses compared with the plans with breast board. There was significant reductions in V20, V<25 and mean doses for lung and V<9 and mean doses for heart. Conclusion: In comparison of both the plans, setup without breast board significantly reduced the dose-volume of the ipsilateral lung and heart in left chest wall patients. Waived registration request has been submitted.

60 APPLIED LIFE SCIENCES↗