Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An Experimental Investigation of Fuel Staging In A Model Gas Turbine Combustor

Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged-stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τT Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a given τ Transient , the decay timescale decreased with increasing staging equivalence ratio. For 1, 16, and 58 ms transients, τ does not depend on τ Transient , though it does strongly depend on direction, where instability onset cases have longer and more variable τ than instability decay cases. The same dependence of τ on direction is seen for the 4,000 and 10,000 ms transients. However, unlike the short duration transients, τ does depend on τ Transient as would be expected. Phase space reconstruction shows the instability is a harmonic limit cycle with a single frequency. The instantaneous phase images shows the center region of the combustor goes out-of-phase first followed by the rest of the combustor. Finally, asymmetric fuel staging tests are conducted. It is found that non-axisymmetric staging can be as effective as axisymmetric staging, although small hardware variations between nozzles can affect the the minimum staging equivalence ratio that consistently suppresses the instability. These changes in the bifurcation equivalence ratio can make staging configurations appear less effective; however, both axisymmetric and non-axisymmetric staging configurations exhibit similar staged-stable p' RMS , damping rates, and instability transition times for equivalence ratios greater than the bifurcation equivalence ratio. Instantaneous phase images show similar instantaneous phase relationship structures in the staged nozzle (center or outer), suggesting that the instability suppression mechanism is similar in each case. This result is surprising given that the time-averaged flame shapes are very different between axisymmetric and non-axisymmetric staging configurations. The similar effectiveness of axisymmetric and non-axisymmetric staging in this geometry is attributed to the fact that the instability mode is a nominally axisymmetric plane wave. It is hypothesized that non-axisymmetric staging configurations will likely be more effective than axisymmetric staging configurations when the instability mode shape is asymmetric (such as a circumferential wave).

Culler, Wyatt↗

A multi-phase level set framework for source reconstruction in bioluminescence tomography

We propose a novel multi-phase level set algorithm for solving the inverse problem of bioluminescence tomography. The distribution of unknown interior source is considered as piecewise constant and represented by using multiple level set functions. The localization of interior bioluminescence source is implemented by tracing the evolution of level set function. An alternate search scheme is incorporated to ensure the global optimal of reconstruction. Both numerical and physical experiments are performed to evaluate the developed level set reconstruction method. Reconstruction results show that the proposed method can stably resolve the interior source of bioluminescence tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Target-specific optimization of four-dimensional cone beam computed tomography

Purpose: Under-sampling artifacts are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) and may compromise evaluation of target motion. Several studies have addressed scan parameter selection for minimizing under-sampling artifacts; however, the role of the target characteristics in scan parameter selection has not been investigated. In this work, the authors evaluated 4D-CBCT performance by assessing the accuracy of target motion measurements for various target sizes and motions. The results may serve as patient-specific guidelines for scan parameters selection in 4D-CBCT. Methods: The authors acquired 4D-CBCT scans of a moving phantom consisting of six water-filled sphere targets of sizes 10-37 mm, using various scan times ranging from 30 s to 3 min., setting the motion to 3-s and 6-s periods. The authors used automatic image registration to extract the target motion trajectories and evaluated these measurements for various target sizes and motions over various combinations of scan parameters including scan time, detector configuration, number of respiration phases, and reconstruction filters. Results: The most important object parameter to 4D-CBCT performance was the period of motion. Measurements for the 6-s motion were always systematically less accurate than measurements for the 3-s motion for 34 of 36 objects of various sizes and periods of motion. The 6-s motion required a greater scan time than the 3-s motion for equivalent measurement accuracy. The second most influential parameter was the target size. For the 3-s period of motion, objects larger than 13 mm were tracked with sub-millimeter accuracy with a 1-min scan time. For the 6-s period of motion, objects larger than 22-mm were tracked with sub-millimeter accuracy with a 1.5-min scan time. For all sizes and motions, temporal blurring was observed when the number of phases was fewer than 8. Offset detector configuration provided the same performance as centered detector except for small targets (20 mm.) at short scan times ({<=}1 min). Finally, reconstruction filtering and number of respiratory phases did not affect performance. Conclusions: Scan time should be set according to target size and motion. The authors have provided figures that provide the minimum scan time needed to achieve the particular motion measurement accuracy for a particular size and motion period.

60 APPLIED LIFE SCIENCES↗

Reconstruction of Six-Dimensional Phase Space

A phase space is a mathematical representation of all possible physical states of a system. Particle beams at Fermilab exist within a six-dimensional (6D) phase space defined by three positional components, (x, y, z) and three momentum components, (px, py, pz). To reconstruct this space implies taking measurement data from detectors and mapping out particle behavior using computational methods. The beam detectors, however, are only able to detect spatial distribution among the events of the beam, therefore being limited to positional data. Also, due to the vast number of events in a particle beam, it is extremely difficult to analyze and differentiate every single one’s behavior. However, with Machine Learning (ML), which can distinguish between patterns and map out particle behavior more efficiently. We first used the particle beam software, G4beamline, to simulate a 10,000-event muon beam, adjusting parameters such as initial momentum magnitude (p¬0) and virtual detector position. Using ten virtual detectors, we analyzed p0 values such that minimum 9,990 events were analyzed by every detector. We then input the data from these beam simulations to a C++ program, that randomly selects 100 events, and creates a 2D histogram based on spatial distribution, detector position, and event intensity. This process is repeated 100 times to create 100 histograms per p0 value. These images were then input to a modified ResNet18 Convolutional Neural Network (CNN) for training, and to predict p0 from some unseen set of histograms. The model was accurate when trained on momentum increments of 5 MeV/c and provided with denser training samples around highly variable test values. These results displayed machine learning being able to accurately predict p0 from being trained on different particle behaviors.

Shirlee, Jermain [Fermilab]↗

Particle flow reconstruction for the CMS Phase-II Level-1 Trigger

The upgrade of the CMS detector for the high-luminosity LHC will include trackfinding for the first time in the Level-1 trigger, enabling Particle Flow reconstruction of every event in addition to comprehensive pileup mitigation. The Correlator trigger will reconstruct isolated leptons and photons, hadronic jets, and energy sums, assisted in many cases by machine learning to benefit from the complete particle-level event record. Here, we present the logic of these algorithms, possible implementations using large FPGAs and their demonstration in prototype hardware, in addition to the expected physics performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic-scale cryogenic electron microscopy imaging of self-assembled peptoid nanostructures

Amphiphilic polypeptoids with defined sequences, versatile in forming various nanostructures, are ideal for mimicking biomacromolecular structures. The predictive design of nanostructures depends on our understanding of the relationship between molecular structure and the locations of atoms in the nanostructure. Factors of importance include chain conformation, crystal motifs, and the arrangement of the molecules within the nanostructure. Here, this review introduces the cryogenic transmission electron microscopy (cryo-TEM) method, sorting and averaging unit cells in nanosheets for resolution enhancement and identifying structural heterogeneity. The resulting atomic-scale images reveal the presence of two types of crystal motifs. The impact of processing conditions, capping group chemistry, and side chain chemistry on structural heterogeneity and crystal motifs can be quantified. The 3D reconstruction of nanosheets, wherein atomic-scale corrugations were revealed, is introduced in this review. New developments in cryo-TEM, such as phase retrieval reconstruction, hold great promise for atomic-scale imaging of soft nanostructures.

36 MATERIALS SCIENCE↗

Peculiarities of adaptive phase correction of optical wave distortions under conditions of ‘strong’ intensity fluctuations

The reason for the loss of efficiency of adaptive phase correction in the propagation of optical waves in a turbulent atmosphere under conditions of ‘strong’ intensity fluctuations is experimentally explained for the first time. Based on the data from experiments conducted on both horizontal and vertical atmospheric paths, we have found that intensity fluctuations begin to significantly affect phase measurements when the coherence radius of the optical wave becomes less than the radius of the first Fresnel zone. Under these conditions, the main meter of adaptive optics systems, i. e. the Hartmann sensor, no longer provides correct measurements of the phase distribution in the presence of deep amplitude modulation. Based on the study of the behaviour of the mode components of the phase fluctuations reconstructed from the results of measurements in various operating regimes, we have found that, first of all, the amplitudes of the lowest modes of phase fluctuation expansion (tilts, defocusing, and astigmatism) are distorted, which, as the analysis shows, is very different from the regime of weak fluctuations. (atmospheric optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Downscaling-Based Segmentation for Unresolved Images of Highly Heterogeneous Granular Porous Samples

Numerical simulations of pore-scale flow and transport in natural sediments require the knowledge of pore-space topology. Limited resolution of X-ray tomography is often insufficient to fully characterize pore-space structure within fine-grained regions. Single and multilevel threshold-based segmentation approaches are customarily employed to identify solid, pore and porous-solid regions by means of grey intensity thresholds. While the choice of cutoff thresholds is often arbitrary, it dramatically affects the effective properties and the dynamical response of the reconstructed porous structure. As such, we propose an algorithm of downscaling, i.e., the process of increasing image resolution, followed by segmentation, i.e., the identification of different phases, to reconstruct the unresolved pore-space from XCT images of natural geological porous media. The method, applicable to moderately unresolved, chemically homogeneous granular media, is based on a map between local pixel porosity and pore size that does not rely on the definition of arbitrary thresholds and it allows to generate a high-resolution binary image of the porous medium from poorly resolved grey-scale images. First, we validate the method on synthetic unresolved images and compare their known pore-space distribution with the extracted one. Then, we consider a synthetic porous medium and compare the pore size distribution, conductivity, and tortuosity between the original and the reconstructed structures. Finally, we apply the method to extract the pore-space distribution from unresolved XCT images of two natural sediment columns and use it (i) to parametrize a capillary-bundle model and (ii) to estimate the hydraulic conductivity by matching breakthrough behavior of passive solute transport.

58 GEOSCIENCES↗

Dynamic diffraction artefacts in Bragg coherent diffractive imaging

This article reports a theoretical study on the reconstruction artefacts in Bragg coherent diffractive imaging caused by dynamical diffraction effects. It is shown that, unlike the absorption and refraction effects that can be corrected after reconstruction, dynamical diffraction effects have profound impacts on both the amplitude and the phase of the reconstructed complex object, causing strong artefacts. At the dynamical diffraction limit, the reconstructed shape is no longer correct, as a result of the strong extinction effect. Simulations for hemispherical particles of different sizes show the type, magnitude and extent of the dynamical diffraction artefacts, as well as the conditions under which they are negligible.

36 MATERIALS SCIENCE↗

Direct single-shot phase retrieval from the diffraction pattern of separated objects

The non-crystallographic phase problem arises in numerous scientific and technological fields. An important application is coherent diffractive imaging. Recent advances in X-ray free-electron lasers allow capturing of the diffraction pattern from a single nanoparticle before it disintegrates, in so-called ‘diffraction before destruction’ experiments. Presently, the phase is reconstructed by iterative algorithms, imposing a non-convex computational challenge, or by Fourier holography, requiring a well-characterized reference field. Here we present a convex scheme for single-shot phase retrieval for two (or more) sufficiently separated objects, demonstrated in two dimensions. In our approach, the objects serve as unknown references to one another, reducing the phase problem to a solvable set of linear equations. We establish our method numerically and experimentally in the optical domain and demonstrate a proof-of-principle single-shot coherent diffractive imaging using X-ray free-electron lasers pulses. Lastly, our scheme alleviates several limitations of current methods, offering a new pathway towards direct reconstruction of complex objects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Simple, Low Cost Longitudinal Phase Space Diagnostic

For proper operation of the LCLS [1] x-ray free-electron laser (FEL), and other similar machines, measurement and control of the electron bunch longitudinal phase space is critical. The LCLS accelerator includes two bunch compressor chicanes to magnify the peak current. These magnetic chicanes can generate significant coherent synchrotron radiation (CSR), which can distort the phase space distribution. We propose a diagnostic scheme by exciting a weak skew quadrupole at an energy-chirped, high dispersion point in the first LCLS bunch compressor (BC1) to reconstruct longitudinal phase space on an OTR screen after BC1, allowing a time-resolved characterization of CSR effects.

43 PARTICLE ACCELERATORS↗

Nondegenerate phase-conjugate wave via stored atomic coherence based on electromagnetically induced transparency in solids

A nondegenerate phase-conjugate wave was generated via stored atomic coherence in a Pr{sup 3+}:Y{sub 2}SiO{sub 5} crystal based on the electromagnetically induced transparency effect, and its capability for wave-front reconstruction of phase distortion was demonstrated experimentally. The phase-matching condition during the storage-retrieval process of the phase-conjugate wave was characterized both experimentally and theoretically in detail. Theoretical simulations fit the experimental data very well. Such a scheme of storage and retrieval of the phase-conjugate wave may have potential applications in optical signal processing and information security.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cosmic-ray anisotropies in right ascension measured by the Pierre Auger Observatory

We present measurements of the large-scale cosmic-ray anisotropies in right ascension, using data collected by the surface detector array of the Pierre Auger Observatory over more than 14 years. We determine the equatorial dipole component, $\vec{d}_\perp$, through a Fourier analysis in right ascension that includes weights for each event so as to account for the main detector-induced systematic effects. For the energies at which the trigger efficiency of the array is small, the ``East-West'' method is employed. Besides using the data from the array with detectors separated by 1500 m, we also include data from the smaller but denser sub-array of detectors with 750 m separation, which allows us to extend the analysis down to $\sim 0.03$ EeV. The most significant equatorial dipole amplitude obtained is that in the cumulative bin above 8~EeV, $d_\perp=6.0^{+1.0}_{-0.9}$%, which is inconsistent with isotropy at the 6$\sigma$ level. In the bins below 8 EeV, we obtain 99% CL upper-bounds on $d_\perp$ at the level of 1 to 3 percent. At energies below 1 EeV, even though the amplitudes are not significant, the phases determined in most of the bins are not far from the right ascension of the Galactic center, at $\alpha_{\rm GC}=-94^\circ$, suggesting a predominantly Galactic origin for anisotropies at these energies. The reconstructed dipole phases in the energy bins above 4 EeV point instead to right ascensions that are almost opposite to the Galactic center one, indicative of an extragalactic cosmic ray origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomically resolved structural determination of graphene and its point defects via extrapolation assisted phase retrieval

Previously reported crystalline structures obtained by an iterative phase retrieval reconstruction of their diffraction patterns seem to be free from displaying any irregularities or defects in the lattice, which appears to be unrealistic. We demonstrate here that the structure of a nanocrystal including its atomic defects can unambiguously be recovered from its diffraction pattern alone by applying a direct phase retrieval procedure not relying on prior information of the object shape. Individual point defects in the atomic lattice are clearly apparent. Conventional phase retrieval routines assume isotropic scattering. We show that when dealing with electrons, the quantitatively correct transmission function of the sample cannot be retrieved due to anisotropic, strong forward scattering specific to electrons. We summarize the conditions for this phase retrieval method and show that the diffraction pattern can be extrapolated beyond the original record to even reveal formerly not visible Bragg peaks. Such extrapolated wave field pattern leads to enhanced spatial resolution in the reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microstructure and fission products in the UCO kernel of an AGR-1 TRISO fuel particle after post irradiation safety testing

Tristructural isotropic (TRISO) coated particle fuel as a key fuel concept for the High Temperature Gas-cooled Reactors (HTGRs) and a candidate accident tolerant fuel (ATF) has been currently investigated under the US-DOE Advanced Gas Reactor (AGR) fuel development and qualification program. Over the past decades, extensive studies have been conducted to evaluate the fission product release, diffusion on Ag, Pd and Cd in the SiC layer and the TRISO coating system, and post-safety-test performance. However, to date, there are limited reported results on the fuel kernels’ response to irradiation with or without post irradiation high temperature annealing. To incrementally fulfill this knowledge gap extensive studies using transmission electron microscopes (TEM) and atom probe tomography (APT) were conducted on a TRISO fuel particle kernel with a 19.74% 235U enrichment, irradiated to 18.63% FIMA and subsequently subjected to post-safety testing at 1600ºC for 300 hours.. Microstructure characterizations, elemental analysis, and phase identification were conducted using conventional TEM and scanning TEM (STEM) imaging, energy-dispersive X-ray spectroscopy (EDS), selected-area electron diffraction (SAED) and atom probe tomography (APT). The following findings were made: (1) significant reconstructions and phase evolutions occurred in the irradiated and post-safety annealed fuel kernel, and its microstructure consists of two primary phases, namely a “high-Z (atomic mass)” UC phase and a “low-Z” UO phase, (2) no fission gas bubbles are identified within the fuel kernel, that can be attributed to the high temperature post safety annealing, (3) fission products Zr, Nb, Mo, Ru, Tc and Rh were found to preferentially segregate into UC phase or to form metallic precipitates, while the lanthanide fission products tend to stay in the solution of UO phase, (4) Pd was detected in the rod-shaped precipitates, (5) APT data reveals segregation of Te, Pd, and Ag at the UO and UC phase boundary, and (6) Pd is detected in both the UO and UC phases but with an enrichment in the former one.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental demonstration of novel beam characterization using a polarizable X-band transverse deflection structure

The PolariX TDS (Polarizable X-Band Transverse Deflection Structure) is an innovative TDS-design operating in the X-band frequency-range. The design gives full control of the streaking plane, which can be tuned in order to characterize the projections of the beam distribution onto arbitrary transverse axes. This novel feature opens up new opportunities for detailed characterization of the electron beam. In this paper we present first measurements of the Polarix TDS at the FLASHForward beamline at DESY, including three-dimensional reconstruction of the charge-density distribution of the bunch and slice emittance measurements in both transverse directions. The experimental results open the path toward novel and more extensive beam characterization in the direction of multi-dimensional-beam-phase-space reconstruction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-DE-207A-06: ECG-Gated CT Reconstruction for a C-Arm Inverse Geometry X-Ray System

Purpose: To obtain ECG-gated CT images from truncated projection data acquired with a C-arm based inverse geometry fluoroscopy system, for the purpose of cardiac chamber mapping in interventional procedures. Methods: Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system with a scanned multisource x-ray tube and a photon-counting detector mounted to a C-arm. In the proposed method, SBDX short-scan rotational acquisition is performed followed by inverse geometry CT (IGCT) reconstruction and segmentation of contrast-enhanced objects. The prior image constrained compressed sensing (PICCS) framework was adapted for IGCT reconstruction to mitigate artifacts arising from data truncation and angular undersampling due to cardiac gating. The performance of the reconstruction algorithm was evaluated in numerical simulations of truncated and non-truncated thorax phantoms containing a dynamic ellipsoid to represent a moving cardiac chamber. The eccentricity of the ellipsoid was varied at frequencies from 1–1.5 Hz. Projection data were retrospectively sorted into 13 cardiac phases. Each phase was reconstructed using IGCT-PICCS, with a nongated gridded FBP (gFBP) prior image. Surface accuracy was determined using Dice similarity coefficient and a histogram of the point distances between the segmented surface and ground truth surface. Results: The gated IGCT-PICCS algorithm improved surface accuracy and reduced streaking and truncation artifacts when compared to nongated gFBP. For the non-truncated thorax with 1.25 Hz motion, 99% of segmented surface points were within 0.3 mm of the 15 mm diameter ground truth ellipse, versus 1.0 mm for gFBP. For the truncated thorax phantom with a 40 mm diameter ellipse, IGCT-PICCS surface accuracy measured 0.3 mm versus 7.8 mm for gFBP. Dice similarity coefficient was 0.99–1.00 (IGCT-PICCS) versus 0.63–0.75 (gFBP) for intensity-based segmentation thresholds ranging from 25–75% maximum contrast. Conclusions: The PICCS algorithm was successfully applied to reconstruct truncated IGCT projection data with angular undersampling resulting from simulated cardiac gating. Research supported by the National Heart, Lung, and Blood Institute of the NIH under award number R01HL084022. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.

60 APPLIED LIFE SCIENCES↗