Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An accuracy assessment of different rigid body image registration methods and robotic couch positional corrections using a novel phantom

Purpose: Image guided radiotherapy (IGRT) using cone beam computed tomography (CBCT) images greatly reduces interfractional patient positional uncertainties. An understanding of uncertainties in the IGRT process itself is essential to ensure appropriate use of this technology. The purpose of this study was to develop a phantom capable of assessing the accuracy of IGRT hardware and software including a 6 degrees of freedom patient positioning system and to investigate the accuracy of the Elekta XVI system in combination with the HexaPOD robotic treatment couch top. Methods: The constructed phantom enabled verification of the three automatic rigid body registrations (gray value, bone, seed) available in the Elekta XVI software and includes an adjustable mount that introduces known rotational offsets to the phantom from its reference position. Repeated positioning of the phantom was undertaken to assess phantom rotational accuracy. Using this phantom the accuracy of the XVI registration algorithms was assessed considering CBCT hardware factors and image resolution together with the residual error in the overall image guidance process when positional corrections were performed through the HexaPOD couch system. Results: The phantom positioning was found to be within 0.04 ({sigma}= 0.12) Degree-Sign , 0.02 ({sigma}= 0.13) Degree-Sign , and -0.03 ({sigma}= 0.06) Degree-Sign in X, Y, and Z directions, respectively, enabling assessment of IGRT with a 6 degrees of freedom patient positioning system. The gray value registration algorithm showed the least error in calculated offsets with maximum mean difference of -0.2({sigma}= 0.4) mm in translational and -0.1({sigma}= 0.1) Degree-Sign in rotational directions for all image resolutions. Bone and seed registration were found to be sensitive to CBCT image resolution. Seed registration was found to be most sensitive demonstrating a maximum mean error of -0.3({sigma}= 0.9) mm and -1.4({sigma}= 1.7) Degree-Sign in translational and rotational directions over low resolution images, and this is reduced to -0.1({sigma}= 0.2) mm and -0.1({sigma}= 0.79) Degree-Sign using high resolution images. Conclusions: The phantom, capable of rotating independently about three orthogonal axes was successfully used to assess the accuracy of an IGRT system considering 6 degrees of freedom. The overall residual error in the image guidance process of XVI in combination with the HexaPOD couch was demonstrated to be less than 0.3 mm and 0.3 Degree-Sign in translational and rotational directions when using the gray value registration with high resolution CBCT images. However, the residual error, especially in rotational directions, may increase when the seed registration is used with low resolution images.

60 APPLIED LIFE SCIENCES↗

SU-E-T-132: Dosimetric Impact of Positioning Errors in Hypo-Fractionated Cranial Radiation Therapy Using Frameless Stereotactic BrainLAB System

Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin, Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion: The initial BrainLAB IR system based on rigidity of the mask-frame setup is not sufficient for accurate stereotactic positioning; however, with X-ray imageguidance sub-millimeter accuracy is achieved with negligible deviations in dose coverage. The angular corrections (mean angle summation=1.84°) are important and cause considerable deviations in dose coverage.

60 APPLIED LIFE SCIENCES↗

SU-C-19A-04: Evaluation of Patient Positioning Reproducibility with Three Supine Breast Boards

Purpose: To evaluate positioning reproducibility using three commercially available breast board immobilization systems for whole breast radiation therapy. Methods: Weekly pre-treatment cone beam CT images from 18 free-breathing breast radiotherapy patients, each immobilized with one of three breast boards, were retrospectively registered to the planning CT. Relative shifts between breast tissue and sternum/chest wall (CW), and breast tissue and spine compared to planning CT were obtained for each board. Positioning reproducibility, inter-patient variation and intra-patient variation were evaluated by group mean (M), standard deviation of group mean (Σ) and standard deviation of random shift (σ). Margins to account for setup uncertainties were calculated based on shift uncertainties in x, y, and z directions. Results: For breast positioning relative to sternum/CW, the average shift from planned positioning was 4.5mm (95% CI: 3.5 – 5.3), 3.3mm (CI: 2.9 - 3.8) and 2.6mm (CI: 1.8 - 3.5) for Breast Boards I, II, and III, respectively. The respective numbers for breast positioning relative to spine were 7.2 mm (CI: 4.1 – 10.3), 6.4 mm (CI: 4.3 – 8.3) and 4.3 mm (CI: 2.5 – 6.2). Localizing to the sternum/CW as a surrogate for the breast tissue, margins for setup uncertainties were 5.7mm, 5.5mm, and 6.0mm for Breast Board I, 5.0mm, 4.0mm and 4.3mm for Breast Board II, and 3.8mm, 3.5mm and 4.8mm for Breast Board III, in the lateral, anterior/posterior, and superior/inferior directions, respectively. Conclusion: Better patient positioning reproducibility was observed with Boards II and III compared to Board I. Inter- and intra-patient set-up uncertainties were also improved with Boards II and III, which requires smaller PTV margins. Independent of breast board, breast cancer patient positioning to the sternum/CW is a better surrogate than the spine. Our findings have potential dosimetric consequences from set-up uncertainties when employing IMRT or proton treatments, and further analyses are on-going.

60 APPLIED LIFE SCIENCES↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

Positivity Limiters for Filtered Spectral Approximations of Linear Kinetic Transport Equations

We analyze the properties and compare the performance of several positivity limiters for spectral approximations with respect to the angular variable of linear transport equations. It is well-known that spectral methods suffer from the occurrence of (unphysical) negative spatial particle concentrations due to the fact that the underlying polynomial approximations are not always positive at the kinetic level. Positivity limiters address this defect by enforcing positivity of the polynomial approximation on a finite set of preselected points. With a proper PDE solver, they ensure positivity of the particle concentration at each step in a time integration scheme. We review several known positivity limiters proposed in other contexts and also introduce a modification for one of them. We give error estimates for the consistency of the positive approximations produced by these limiters and compare the theoretical estimates to numerical results. We then solve two benchmark problems with these limiters, make qualitative and quantitative observations about the solutions, and then compare the efficiency of the different limiters.

97 MATHEMATICS AND COMPUTING↗

Number and Location of Positive Nodes, Postoperative Radiotherapy, and Survival After Esophagectomy With Three-Field Lymph Node Dissection for Thoracic Esophageal Squamous Cell Carcinoma

Purpose: To analyze influences of the number and location of positive lymph nodes and postoperative radiotherapy on survival for patients with thoracic esophageal squamous cell carcinoma (TE-SCC) treated with radical esophagectomy with three-field lymphadenectomy. Methods and Materials: A total of 945 patients underwent radical esophagectomy plus three-field lymph node dissection for node-positive TE-SCC at Fujian Provincial Tumor Hospital between January 1993 and March 2007. Five hundred ninety patients received surgery only (S group), and 355 patients received surgery, followed 3 to 4 weeks later by postoperative radiotherapy (S+R group) to a median total dose of 50 Gy in 25 fractions. We assessed potential associations among patient-, tumor-, and treatment-related factors and overall survival. Results: Five-year overall survival rates were 32.8% for the entire group, 29.6% for the S group, and 38.0% for the S+R group (p = 0.001 for S vs. S+R). Treatment with postoperative radiotherapy was particularly beneficial for patients with {>=}3 positive nodes and for those with metastasis in the upper (supraclavicular and upper mediastinal) region or both the upper and lower (mediastinal and abdominal) regions (p < 0.05). Postoperative radiotherapy was also associated with lower recurrence rates in the supraclavicular and upper and middle mediastinal regions (p < 0.05). Sex, primary tumor length, number of positive nodes, pathological T category, and postoperative radiotherapy were all independent predictors of survival. Conclusions: Postoperative radiotherapy was associated with better survival for patients with node-positive TE-SCC, particularly those with three or more positive nodes and positive nodes in the supraclavicular and superior mediastinal regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Reproducibility in Pancreatic Position Based on Four-Dimensional Computed Tomography

Purpose: To assess the interfractional positional variation of the pancreas using four-dimensional computed tomography (4D-CT) and to determine the suitable phase of respiration for dose delivery methods to account for pancreatic tumor motion. Methods and Materials: Fifteen patients with pancreatic cancer were enrolled in this study. For each patient, 4D-CT scans were performed at CT simulation and three times during the course of treatment. Regions of interest were set to the intrapancreatic bile ducts as a surrogate for pancreatic position. The centroids of the regions of interest were calculated at end-inhalation and end-exhalation of the respiration phase. The ranges of respiratory motion and interfractional positional variation were evaluated in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions. Results: The medians of respiratory motion were 1.1 mm (range, 0.0-9.8 mm), 1.5 mm (range, 0.0-7.0 mm), and 5.0 mm (range, 0.0-12.5 mm) in the LR, AP, and SI directions, respectively. The means {+-} SDs of the interfractional positional variation at end-inhalation were 0.9 {+-} 5.1 mm (range, -9.2 to 15.6 mm), -1.9 {+-} 3.9 mm (range, -12.8 to 6.4 mm), and -1.3 {+-} 6.9 mm (range, -15.0 to 13.7 mm) and those at end-exhalation were 0.0 {+-} 3.1 mm (range, -7.0 to 5.3 mm), -1.2 {+-} 3.9 mm (range, -11.2 to 6.7 mm), and 0.1 {+-} 3.2 mm (range, -9.9 to 5.1 mm) in the LR, AP, and SI directions, respectively. The SDs of the interfractional positional variation in the LR and SI directions were significantly larger at end-inhalation than at end-exhalation (LR, p < 0.001; SI, p < 0.001). Conclusions: The ranges of respiratory motion during the course of treatment and the interfractional positional variation were not negligible. The interfractional positional reproducibility was higher at end-exhalation than at end-inhalation under free breathing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Factors for Regional Nodal Relapse in Breast Cancer Patients With One to Three Positive Axillary Nodes

Purpose: In many centers, supraclavicular fossa radiotherapy (SCF RT) is not routinely offered to breast cancer patients with one to three positive lymph nodes. We aimed to identify a subgroup of these patients who are at high risk of supra or infraclavicular fossa relapse (SCFR) such that they can be offered SCFRT at the time of diagnosis to improve long term locoregional control. Methods and Materials: We performed a retrospective analysis of the pathological features of 1,065 cases of invasive breast cancer with one to three positive axillary lymph nodes. Patients underwent radical breast conserving surgery or mastectomy. A total of 45% of patients received adjuvant chest wall/breast RT. No patients received adjuvant SCFRT. The primary outcome was SCFR. Secondary outcomes were chest wall/breast recurrence, distant metastasis, all death, and breast-cancer specific death. Kaplan-Meier estimates were used to calculate actuarial event rates and survival functions compared using log-rank tests. Multivariate analyses (MVA) of factors associated with outcome were conducted using Cox proportional hazards models. Results: Median follow-up was 9.7 years. SCFR rate was 9.2%. Median time from primary diagnosis to SCFR was 3.4 years (range, 0.7-14.4 years). SCFR was associated with significantly lower 10-year survival (18% vs. 65%; p < 0.001). Higher grade and number of positive lymph nodes were the most significant predictors of SCFR on MVA (p < 0.001). 10 year SCFR rates were less than 1% in all patients with Grade 1 cancers compared with 30% in those having Grade 3 cancers with three positive lymph nodes. Additional factors associated with SCFR on univariate analysis but not on MVA included larger nodal deposits (p = 0.002) and proportion of positive nodes (p = 0.003). Conclusions: Breast cancer patients with one to three positive lymph nodes have a heterogenous risk of SCFR. Patients with two to three positive axillary nodes and/or high-grade disease may warrant consideration of SCFRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Importance of Local Control in Early-Stage Prostate Cancer: Outcomes of Patients With Positive Post-Radiation Therapy Biopsy Results Treated in RTOG 9408

Purpose: The purpose of this study was to assess the association between positive post-radiation therapy (RT) biopsy results and subsequent clinical outcomes in males with localized prostate cancer. Methods and Materials: Radiation Therapy Oncology Group study 94-08 analyzed 1979 males with prostate cancer, stage T1b-T2b and prostate-specific antigen concentrations of ≤20 ng/dL, to investigate whether 4 months of total androgen suppression (TAS) added to RT improved survival compared to RT alone. Patients randomized to receive TAS received flutamide with luteinizing hormone releasing hormone (LHRH) agonist. According to protocol, patients without evidence of clinical recurrence or initiation of additional endocrine therapy underwent repeat prostate biopsy 2 years after RT completion. Statistical analysis was performed to evaluate the impact of positive post-RT biopsy results on clinical outcomes. Results: A total of 831 patients underwent post-RT biopsy, 398 were treated with RT alone and 433 with RT plus TAS. Patients with positive post-RT biopsy results had higher rates of biochemical failure (hazard ratio [HR] = 1.7; 95% confidence interval [CI] = 1.3-2.1) and distant metastasis (HR = 2.4; 95% CI = 1.3-4.4) and inferior disease-specific survival (HR = 3.8; 95% CI = 1.9-7.5). Positive biopsy results remained predictive of such outcomes after correction for potential confounders such as Gleason score, tumor stage, and TAS administration. Prior TAS therapy did not prevent elevated risk of adverse outcome in the setting of post-RT positive biopsy results. Patients with Gleason score ≥7 with a positive biopsy result additionally had inferior overall survival compared to those with a negative biopsy result (HR = 1.56; 95% CI = 1.04-2.35). Conclusions: Positive post-RT biopsy is associated with increased rates of distant metastases and inferior disease-specific survival in patients treated with definitive RT and was associated with inferior overall survival in patients with high-grade tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of sub-pixel position resolution with time-correlated transient signals in 3D pixelated CdZnTe detectors with varying pixel sizes

Here, we evaluated the sub-pixel position resolution achievable in large-volume CdZnTe pixelated detectors with conventional pixel patterns and for several different pixel sizes: 2.8 mm, 1.72 mm, 1.4 mm and 0.8 mm. Achieving position resolution below the physical dimensions of pixels (sub-pixel resolution) is a practical path for making high-granularity position-sensitive detectors, <100 μμm, using a limited number of pixels dictated by the mechanical constraints and multi-channel readout electronics. High position sensitivity is important for improving the imaging capability of CZT gamma cameras. It also allows for making more accurate corrections of response non-uniformities caused by crystal defects, thus enabling use of standard-grade (unselected) and less expensive CZT crystals for producing large-volume position-sensitive CZT detectors feasible for many practical applications. We analyzed the digitized charge signals from a representative 9 pixels and the cathode, generated using a pulsed-laser light beam focused down to 10 m (650 nm) to scan over a selected 3×3 pixel area. We applied our digital pulse processing technique to the time-correlated signals captured from adjacent pixels to achieve and evaluate the capability for sub-pixel position resolution. As an example, we also demonstrated an application of 3D corrections to improve the energy resolution and positional information of the events for the tested detectors.

36 MATERIALS SCIENCE↗

Tau PET positivity in individuals with and without cognitive impairment varies with age, amyloid-β status, APOE genotype and sex

Abstract Tau positron emission tomography (PET) imaging allows in vivo detection of tau proteinopathy in Alzheimer’s disease, which is associated with neurodegeneration and cognitive decline. Understanding how demographic, clinical and genetic factors relate to tau PET positivity will facilitate its use for clinical practice and research. Here we conducted an analysis of 42 cohorts worldwide (N = 12,048), including 7,394 cognitively unimpaired (CU) participants, 2,177 participants with mild cognitive impairment (MCI) and 2,477 participants with dementia. We found that from age 60 years to 80 years, tau PET positivity in a temporal composite region increased from 1.1% to 4.4% among CU amyloid-β (Aβ)-negative participants and from 17.4% to 22.2% among CU Aβ-positive participants. Across the same age span, tau PET positivity decreased from 68.0% to 52.9% in participants with MCI and from 91.5% to 74.6% in participants with dementia. Age, Aβ status,APOEε4 carriership and female sex were all associated with a higher prevalence of tau PET positivity across groups.APOEε4 carriership in CU individuals lowered the age at onset of both Aβ positivity and tau positivity by decades. Finally, we replicated these associations in an independent autopsy dataset (N = 5,072 from 3 cohorts).

Neurosciences & Neurology↗

Elemental Zn and its Binding Protein Zinc-α2-Glycoprotein are Elevated in HPV-Positive Oropharyngeal Squamous Cell Carcinoma

Human papillomavirus (HPV)-positive head and neck squamous cell carcinoma (HNSCC) is biologically distinct from HPV-negative HNSCC. Outside of HPV-status, few tumor-intrinsic variables have been identified that correlate to improved survival. As part of exploratory analysis into the trace elemental composition of oropharyngeal squamous cell carcinoma (OPSCC), we performed elemental quanitification by X-ray fluorescence microscopy (XFM) on a small cohort (n = 32) of patients with HPV-positive and -negative OPSCC and identified in HPV-positive cases increased zinc (Zn) concentrations in tumor tissue relative to normal tissue. Subsequent immunohistochemistry of six Zn-binding proteins-zinc-alpha 2-glycoprotein (AZGP1), Lipocalin-1, Albumin, S100A7, S100A8 and S100A9-revealed that only AZGP1 expression significantly correlated to HPV-status (p < 0.001) and was also increased in tumor relative to normal tissue from HPV-positive OPSCC tumor samples. AZGP1 protein expression in our cohort significantly correlated to a prolonged recurrence-free survival (p = 0.029), similar to HNSCC cases from the TCGA (n = 499), where highest AZGP1 mRNA levels correlated to improved overall survival (p = 0.023). By showing for the first time that HPV-positive OPSCC patients have increased intratumoral Zn levels and AZGP1 expression, we identify possible positive prognostic biomarkers in HNSCC as well as possible mechanisms of increased sensitivity to chemoradiation in HPV-positive OPSCC.

60 APPLIED LIFE SCIENCES↗

Positivity of linear maps under tensor powers

We investigate linear maps between matrix algebras that remain positive under tensor powers, i.e., under tensoring with n copies of themselves. Completely positive and completely co-positive maps are trivial examples of this kind. We show that for every n ∈ ℕ, there exist non-trivial maps with this property and that for two-dimensional Hilbert spaces there is no non-trivial map for which this holds for all n. For higher dimensions, we reduce the existence question of such non-trivial “tensor-stable positive maps” to a one-parameter family of maps and show that an affirmative answer would imply the existence of non-positive partial transpose bound entanglement. As an application, we show that any tensor-stable positive map that is not completely positive yields an upper bound on the quantum channel capacity, which for the transposition map gives the well-known cb-norm bound. We, furthermore, show that the latter is an upper bound even for the local operations and classical communications-assisted quantum capacity, and that moreover it is a strong converse rate for this task.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of enzyme active site positioning and tests of catalytic mechanisms through X-ray–derived conformational ensembles

How enzymes achieve their enormous rate enhancements remains a central question in biology, and our understanding to date has impacted drug development, influenced enzyme design, and deepened our appreciation of evolutionary processes. While enzymes position catalytic and reactant groups in active sites, physics requires that atoms undergo constant motion. Numerous proposals have invoked positioning or motions as central for enzyme function, but a scarcity of experimental data has limited our understanding of positioning and motion, their relative importance, and their changes through the enzyme’s reaction cycle. To examine positioning and motions and test catalytic proposals, we collected “room temperature” X-ray crystallography data for Pseudomonas putida ketosteroid isomerase (KSI), and we obtained conformational ensembles for this and a homologous KSI from multiple PDB crystal structures. Here, ensemble analyses indicated limited change through KSI’s reaction cycle. Active site positioning was on the 1- to 1.5-Å scale, and was not exceptional compared to noncatalytic groups. The KSI ensembles provided evidence against catalytic proposals invoking oxyanion hole geometric discrimination between the ground state and transition state or highly precise general base positioning. Instead, increasing or decreasing positioning of KSI’s general base reduced catalysis, suggesting optimized Ångstrom-scale conformational heterogeneity that allows KSI to efficiently catalyze multiple reaction steps. Ensemble analyses of surrounding groups for WT and mutant KSIs provided insights into the forces and interactions that allow and limit active-site motions. Most generally, this ensemble perspective extends traditional structure–function relationships, providing the basis for a new era of “ensemble–function” interrogation of enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Suitability of markerless EPID tracking for tumor position verification in gated radiotherapy

Purpose: To maximize the benefits of respiratory gated radiotherapy (RGRT) of lung tumors real-time verification of the tumor position is required. This work investigates the feasibility of markerless tracking of lung tumors during beam-on time in electronic portal imaging device (EPID) images of the MV therapeutic beam. Methods: EPID movies were acquired at ∼2 fps for seven lung cancer patients with tumor peak-to-peak motion ranges between 7.8 and 17.9 mm (mean: 13.7 mm) undergoing stereotactic body radiotherapy. The external breathing motion of the abdomen was synchronously measured. Both datasets were retrospectively analyzed inPortalTrack, an in-house developed tracking software. The authors define a three-step procedure to run the simulations: (1) gating window definition, (2) gated-beam delivery simulation, and (3) tumor tracking. First, an amplitude threshold level was set on the external signal, defining the onset of beam-on/-off signals. This information was then mapped onto a sequence of EPID images to generate stamps of beam-on/-hold periods throughout the EPID movies in PortalTrack, by obscuring the frames corresponding to beam-off times. Last, tumor motion in the superior-inferior direction was determined on portal images by the tracking algorithm during beam-on time. The residual motion inside the gating window as well as target coverage (TC) and the marginal target displacement (MTD) were used as measures to quantify tumor position variability. Results: Tumor position monitoring and estimation from beam's-eye-view images during RGRT was possible in 67% of the analyzed beams. For a reference gating window of 5 mm, deviations ranging from 2% to 86% (35% on average) were recorded between the reference and measured residual motion. TC (range: 62%–93%; mean: 77%) losses were correlated with false positives incidence rates resulting mostly from intra-/inter-beam baseline drifts, as well as sudden cycle-to-cycle fluctuations in exhale positions. Both phenomena can lead to considerable deviations (with MTD values up to a maximum of 7.8 mm) from the intended tumor position, and in turn may result in a marginal miss. The difference between tumor traces determined within the gating window against ground truth trajectory maps was 1.1 ± 0.7 mm on average (range: 0.4–2.3 mm). Conclusions: In this retrospective analysis of motion data, it is demonstrated that the system is capable of determining tumor positions in the plane perpendicular to the beam direction without the aid of fiducial markers, and may hence be suitable as an online verification tool in RGRT. It may be possible to use the tracking information to enable on-the-fly corrections to intra-/inter-beam variations by adapting the gating window by means of a robotic couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.

60 APPLIED LIFE SCIENCES↗

SU-E-T-307: Dosimetric Comparison of Prone Versus Supine Positioning for Adjuvant Breast Radiation Therapy

Purpose: The prone treatment position has been used to reduce ipsilateral lung and heart dose in left breast radiation. We conducted a retrospective study to evaluate the difference in the dosimetry between prone and supine treatment positions. Methods: Eight left breast cancer patients were simulated in both the supine and prone positions as a pretreatment evaluation for the optimal treatment position. Treatment plans were created for all patients in both the supine and prone positions using a field in field three dimensional planning technique. Prescribed dose was 45 Gy delivered by two tangential photon fields. Irradiated volume (IV) was evaluated by V50, V100, and dose to lung and heart by V5, V10, V20, and the mean dose were evaluated. Results: All dosimetry metrics for both the supine and prone plans met our internal normal structure guidelines which are based on Quantec data. The average IVs (50% and 100%) were 2223cc and 1361cc prone, 2315cc and 1315cc supine. The average ipsilateral lung Mean dose (0.83Gy prone vs 5.8Gy supine), V5 (1.6% prone vs 20.9% supine), V10 (0.78% prone vs 15% supine) and V20 (0.36% prone vs 11% supine) were significantly lower in prone position. Heart Mean dose (1.4Gy prone vs 2.9Gy supine), V10 (1.4% prone vs 5.0% supine) and V20 (0.4% prone vs 3.5% supine) were found improved for all patients except one where the mean dose was the same and all other values were improved. Conclusion: The prone position offer preferable dosimetry for all patients planned in our study. These patients were chosen based on the physician’s belief that they would benefit from prone treatment either because they had large pendulous breasts or due to the amount of heart seen in the field on CT simulation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-347: Effect of MLC Leaf Position Inaccuracy On Dose Distribution for Spinal SBRT with Different Energies and Dose Rates

Purpose: To evaluate dosimetric impact of spinal SBRT when MLC leaf positions deviate from planning positions for different energies and doserates. Methods and Materials: 18 localized spinal metastases patients were selected for SBRT using IMRT planning with 9 posterior beams delivered at gantry angles ranging between 100°–260°. A modern linear accelerator(Varian Turebeam STX with HDMLC 2.5 mm thick leaf at isocenter) IMRT plans were generated using both 6X and 6X-FFF(Flattening filter free) beams with a nominal prescription dose of 6 Gy/fraction to PTV. Doserates ranging from 200–600 MU/min for 6X and 400–1400 MU/min for 6X-FFF, with 200 increments were examined. A fixed amount(0.3, 0.5, 1, and 2 mm) of MLC-leaf position deviation was simulated to each plan under following conditions: 1)only along X1 collimator; 2)with increments at both X1 and X2 collimator directions;3)with reductions at both X1 and X2 collimator directions. Dose was recalculated for each modified plans. Both original and modified plans were delivered using Turebeam STX machine and measured using both portal dosimetry and a 3D dosimeter(Delta4 of ScandiDos). Each field’s Result were compared using following three parameters: the 95% iso-dose level Conformal Index(95%CI), the spinal cord maximum dose(SCDmax), and the planned target volume(PTV) mean dose. Results: Dosimetric impacts on the 95%CI, SCDmax and the PTV mean dose are: 1)negligible if MLC-leaf position deviation only along a single collimator direction ≥1.0 mm,2)substantial if MLC-leaf position increment along both collimator directions ≥0.3 mm(95% CI decreases while SCDmax and PTV mean-dose increase), 3)substantial if MLC-leaf position reduction along both collimator directions ≥0.3 mm(95% CI first increases and then decreases while SCDmax and PTV mean-dose decrease). Different energies and doserates demonstrated comparable dosimetric impacts. Conclusion: Substantial dose deviations could happen for spinal SBRT using IMRT plan with HD-MLC if leaf position deviation ≥0.3 mm. The effects of different energy and doserate are negligible.

60 APPLIED LIFE SCIENCES↗