Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design and fabrication of prototype 6×6 cm 2 microchannel plate photodetector with bialkali photocathode for fast timing applications

Planar microchannel plate-based photodetector with bialkali photocathode is capable of fast and accurate time and position resolutions. A new 6 cm x 6 cm photodetector production facility was designed and built at Argonne National Laboratory. Small form-factor MCP-based photodetectors completely constructed of glass were designed and prototypes were successfully fabricated. Knudsen effusion cells were incorporated in the photocathode growth chamber to achieve uniform and high quantum efficiency hotocathodes. The thin film uniformity distribution was simulated and measured for an antimony film deposition, showing uniformity of better than 10%. Several prototype devices with bialkali photocathodes have been fabricated with the described system and their characteristics were evaluated in the large signal (multi-PE) limit. A typical prototype device exhibits time-of-flight resolution of ~ 27 psec and differential time resolution of ~ 9 psec, corresponding to spatial resolution of ~ 0.65 mm.

bialkali photocathode↗

Energy reconstruction of an n-type segmented inverted coaxial point-contact HPGe detector

We have characterized, for the first time, an n-type segmented Inverted Coaxial Point-Contact detector. This novel detector technology relys on a large variation in drift time of the majority charge carriers, as well as image and net charges observed on the segments, to achieve a potential γ-ray interaction position resolution of better than 1 mm. However, the intrinsic energy resolution in such a detector is poor (more than 20 keV at 1332 keV) because of charge (electron) trapping effects. We propose an algorithm that enables restoration of the resolution to a value of 3.44 0.03 keV at 1332 keV for events with a single interaction. The algorithm is based on a measurement of the azimuthal angle and the electron drift time of a given event; the energy of the event is corrected as a function of these two values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The impact of incorporating shell-corrections to energy loss in silicon

Modern silicon tracking detectors based on hybrid or fully integrated CMOS technology are continuing to push to thinner sensors. The ionization energy loss fluctuations in very thin silicon sensors significantly deviates from the Landau distribution. Therefore, we have developed a charge deposition setup that implements the Bichsel straggling function, which accounts for shell-effects. This enhanced simulation is important for comparing with testbeam or collision data with thin sensors as demonstrated by reproducing more realistically the degraded position resolution compared with naïve ionization models based on simple Landau-like fluctuation. Our implementation of the Bichsel model agrees well with the multipurpose photo absorption ionization (PAI) model in Geant4 and is significantly faster. The code is made publicly available as part of the Allpix software package in order to facilitate predictions for new detector designs and comparisons with testbeam data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and test of the Mu2e undoped CsI+SiPM crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating neutrino-less conversion of a negative muoninto an electron in the field of an aluminum nucleus. The calorimeter plays an important role in providing a fast trigger filter,excellent particle identification and a seeding for track reconstruction. Its requirements are to provide an energy (timing) resolutionbetter than 10% (0.5 ns) and a position resolution below 1 cm, for 100 MeV electrons. The calorimeter consists of two disks, eachone made of 674 un-doped CsI crystals readout by two large area arrays of 23 UV-extended SiPMs of 66 mm2dimensions.A large scale prototype (Module-0) has been constructed and tested with an electron beam in the energy range between 60 and 120MeV at the BTF of Frascati National Laboratories. Results demonstrated that this calorimeter satisfies the Mu2e requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype for SANDD: A highly-segmented pulse-shape-sensitive plastic scintillator detector incorporating silicon photomultiplier arrays

We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 × 8 array of plastic scintillator segments coupled to two 5 cm × 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of 6 Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm × 5.4 mm, surrounded by larger cross section bars of the same material. The most important metrics with the potential to impact the performance of the central module of SANDD are neutron and gammaray pulse-shape sensitivity using silicon photomultipliers (SiPMs), particle identification via scintillator rod multiplicity, and energy and position resolution. As a first step, we constructed a prototype detector to investigate the performance of a central SANDD-like module using two 64-channel SiPM arrays and rods of undoped pulse-shape-sensitive plastic scintillator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Superconducting nanowires as high-rate photon detectors in strong magnetic fields

Superconducting nanowire single photon detectors are capable of single-photon detection across a large spectral range, with near unity detection efficiency, picosecond timing jitter, and sub-10 µm position resolution at rates as high as 10 9 counts/s. In an effort to bring this technology into nuclear physics experiments, we fabricate Niobium Nitride nanowire detectors using novel material preparation methods and test their performance in strong magnetic fields. Furthermore, we demonstrate that these devices are capable of detection of 400 nm wavelength photons with saturated internal quantum efficiency at liquid helium temperatures and in magnetic fields potentially up to 8 T at high rates and with nearly zero dark counts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab

A new Large-Acceptance Forward Angle Spectrometer (Super BigBite) is under development at JLab/Hall A to optimally exploit the exciting opportunities o?ered by the 12 GeV upgrade of the electron beam. The tracker of this new apparatus is based on the Gas Electron Multiplier (GEM) technology, which has been chosen to optimize cost/performance, position resolution and to meet the high hit rate (>1 MHz/cm2). The first GEM detector modules, designed and built by the INFN Collaboration JLAB12, were tested at the DESY test beam facility in Hamburg, by using an electron beam with energy ranging from 2.0 to 6.0 GeV. In particular, two 40x50 cm2 and one 10x10 cm2 GEM chambers were equipped with a new implementation of the APV25 readout chip. Measurements were performed at di?erent impact points and angles between the electron beam and the plane of the GEM chambers, with one large chamber in a solenoid magnetic field up to 500 Gauss. In this report we present the technical characteristics of the detector and comment on the presently achieved performance.

Mammoliti, F.↗

Medipix2/USB Portable Radiation Camera

Advances in the field of semiconductor technologies in the last years make possible to develop new types of ionizing radiation detectors. The Medipix2 readout ASIC is an example of such a device. It is the hybrid single photon counting imaging chip (sensor and readout chips are fabricated separately). With an appropriate sensor chip on the top, it can count single X-ray photons, without any noise or dark current, at high fluxes (several Gigaphotons per cm{sup 2} per second). It also offers excellent radiation hardness and good position resolution (256x256 pixels, each pixel has a 55x55 {mu}m{sup 2} area). To make the Medipix2 imaging chip more portable for specific applications a microprocessor controlled read-out system based on the USB (Universal Serial Bus) interface has been developed. It integrates all necessary detector support into one compact device (75x46 mm{sup 2}). All power supplies including sensor bias (up to 100 V) are internally derived from the voltage provided by the USB connection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash radiography with 24 GeV/c protons

The accuracy of density measurements and position resolution in flash (40 ns) radiography of thick objects with 24 Gev/c protons is investigated. A global model fit to step wedge data is shown to give a good description spanning the periodic table. The parameters obtained from the step wedge data are used to predict transmission through the French Test Object (FTO), a test object of nested spheres, to a precision better than 1%. Multiple trials have been used to show that the systematic errors are less than 2%. Absolute agreement between the average radiographic measurements of the density and the known density is 1%. Spatial resolution has been measured to be 200 {mu}m at the center of the FTO. These data verify expectations of the benefits provided by high energy hadron radiography for thick objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanomanipulation and nanofabrication with multi-probe STM: From individual atoms to nanowires

The wide variety of nanoscale structures and devices demands novel tools for handling, assembly, and fabrication at nanoscopic positioning precision. The manipulation tools should allow for in situ characterization and testing of fundamental building blocks, such as nanotubes and nanowires, as they are built into functional devices. In this paper, a bottom-up technique for nanomanipulation and nanofabrication is reported by using a 4-probe scanning tunneling microscope (STM) combined with a scanning electron microscope (SEM). The applications of this technique are demonstrated in a variety of nanosystems, from manipulating individual atoms to bending, cutting, breaking carbon nanofibers, and constructing nanodevices for electrical characterizations. The combination of the wide field of view of SEM, the atomic position resolution of STM, and the flexibility of multiple scanning probes is expected to be a valuable tool for rapid prototyping in the nanoscience and nanotechnology.

Qin, Shengyong↗

Practical method using superposition of individual magnetic fields for initial arrangement of undulator magnets

We have developed a practical method for determining an excellent initial arrangement of magnetic arrays for a pure-magnet Halbach-type undulator. In this method, the longitudinal magnetic field distribution of each magnet is measured using a moving Hall probe system along the beam axis with a high positional resolution. The initial arrangement of magnetic arrays is optimized and selected by analyzing the superposition of all distribution data in order to achieve adequate spectral quality for the undulator. We applied this method to two elliptically polarizing undulators (EPUs), called U#16-2 and U#02-2, at the Photon Factory storage ring (PF ring) in the High Energy Accelerator Research Organization (KEK). The measured field distribution of the undulator was demonstrated to be excellent for the initial arrangement of the magnet array, and this method saved a great deal of effort in adjusting the magnetic fields of EPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An instrument for in situ coherent x-ray studies of metal-organic vapor phase epitaxy of III-nitrides

Here, we describe an instrument that exploits the ongoing revolution in synchrotron sources, optics, and detectors to enable in situ studies of metal-organic vapor phase epitaxy (MOVPE) growth of III-nitride materials using coherent x-ray methods. The system includes high-resolution positioning of the sample and detector including full rotations, an x-ray transparent chamber wall for incident and diffracted beam access over a wide angular range, and minimal thermal sample motion, giving the sub-micron positional stability and reproducibility needed for coherent x-ray studies. The instrument enables surface x-ray photon correlation spectroscopy, microbeam diffraction, and coherent diffraction imaging of atomic-scale surface and film structure and dynamics during growth, to provide fundamental understanding of MOVPE processes.

36 MATERIALS SCIENCE↗

Position sensitive alpha detector for an associated particle imaging system

Associated Particle Imaging (API) is a nuclear technique that provides for the nondestructive determination of 3D isotopic distributions. The method is based on the detection of the alpha particles associated with the neutron emitted in the deuterium-tritium (DT) fusion reaction, which provides information regarding the direction and time of the emitted 14 MeV neutron. Inelastic neutron scattering leads to characteristic gamma-ray emission from certain isotopes, for example 12 C, that can be correlated with the neutron interaction location. An API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector is under development for the nondestructive quantification of carbon distribution in soils. This paper describes the design of the alpha detector, detector response simulations, and first experimental results. The alpha detector consists of a Yttrium Aluminum Perovskite (YAP) scintillator mounted on the inside of a neutron generator tube. The scintillation light propagates through a sapphire window to a position-sensitive photomultiplier tube mounted on the outside. The 16x16 output signals are connected through a resistive network for a 4-corner readout. The four readout channels are amplified, filtered, and then digitized for the calculation of the alpha position. First test findings demonstrate that an excellent alpha position resolution, better than the 1 mm FWHM required by the application, can be achieved with this detector design.

47 OTHER INSTRUMENTATION↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Laboratory and testbeam results for thin and epitaxial planar sensors for HL-LHC

The High-Luminosity LHC (HL-LHC) upgrade of the CMS pixel detector will require the development of novel pixel sensors which can withstand the increase in instantaneous luminosity to L = 5 × 10 34 cm –2 s –1 and collect ~ 3000fb –1 of data. The innermost layer of the pixel detector will be exposed to doses of about 10 16 n eq / cm 2 . Hence, new pixel sensors with improved radiation hardness need to be investigated. A variety of silicon materials (Float-zone, Magnetic Czochralski and Epitaxially grown silicon), with thicknesses from 50 μm to 320 μm in p-type and n-type substrates have been fabricated using single-sided processing. The effect of reducing the sensor active thickness to improve radiation hardness by using various techniques (deep diffusion, wafer thinning, or growing epitaxial silicon on a handle wafer) has been studied. Furthermore, the results for electrical characterization, charge collection efficiency, and position resolution of various n-on-p pixel sensors with different substrates and different pixel geometries (different bias dot gaps and pixel implant sizes) will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗