Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Detection prospects for the second-order weak decays of 124 Xe in multi-tonne xenon time projection chambers

We investigate the detection prospects for two-neutrino and neutrinoless second-order weak decays of 124 Xe – double-electron capture (0/2νECEC), electron capture with positron emission (0/2νECβ + ) and double-positron emission (0/2νβ + β + ) – in multi-tonne xenon time projection chambers. We simulate the decays in a liquid xenon medium and develop a reconstruction algorithm which uses the multi-particle coincidence in these decays to separate signal from background. This is used to compute the expected detection efficiencies as a function of position resolution and energy threshold for planned experiments. In addition, we consider an exhaustive list of possible background sources and find that they are either negligible in rate or can be greatly reduced using our topological reconstruction criteria. In particular, we draw two conclusions: First, with a theoretical half-life of $T^{2νECβ^+}_{1/2}$= (1.7 ± 0.6) ∙10 23 year, the 2νECβ + decay of 124 Xe will likely be detected in upcoming Dark Matter experiments (e.g. XENONnT or LZ), and their major background will be γ-rays from detector construction materials. Second, searches for the 0νECβ + decay mode will likely be background-free, and new parameter space may be within reach. To this end we investigate two different scenarios of existing experimental constraints on the effective neutrino mass. The necessary 500 kg-year exposure of 124 Xe could be achieved by the baseline design of the DARWIN observatory, or by extracting and using the 124 Xe from the tailings of the nEXO experiment. We demonstrate how a combination of 124 Xe results with those from 0νβ - β - searches in 136 Xe could help to identify the neutrinoless decay mechanism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searches for Sub-GeV Dark Matter with NOvA and LDMX and Performance Studies of the Cosmic-Ray Veto for Mu2e

The constituents of dark matter are still unknown, and the viable possibilities span a very large mass range. Specific scenarios for the origin of dark matter sharpen the focus to within about an MeV to 100 TeV. Most of the stable constituents of known matter have masses in the lower range, and a thermal origin for dark matter works in a simple and predictive manner in this mass range as well. Non-gravitational couplings of dark matter to Standard Model particles would make it possible to produce dark matter at accelerators. Through 120 GeV proton-nucleus collisions, NOvA is effectively a beam dump experiment for producing and detecting dark matter. This thesis presents a search for dark matter – electron scattering in the NOvA near detector from sub-GeV dark matter produced at the target. A future search for sub-GeV dark matter with the Light Dark Matter eXperiment (LDMX) is discussed, along with a study of LDMX's expected sensitivity to visibly decaying dark photons. Additionally, performance studies of the Mu2e cosmic ray veto (CRV) are presented. A calibration procedure for the CRV counters is discussed, along with tests of the efficiency, position resolution, and light yield decline of the CRV counters.

Horoho, Tyler Gregory [Virginia U.] (ORCID:0000000↗

Development of Large-Area Photo-Detectors (Final Scientific/Technical Report)

This proposal requested ADR funds for two years to make measurements and detector proto-types in the context of planning a program in conjunction with Argonne National Laboratory to develop very large-area planar photodetectors. The proposed detectors have integrated transmission-line readout and sampling electronics able to achieve timing and position resolutions in the range of 1-50 psec and 1-10 mm, respectively. The capability for very precise time measurements is inherent in the design, and provides a third coordinate, orthogonal to the two in the plane, for the point of origin of photons or charged particles, allowing tomographic reconstruction in 3-dimensions inside a volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiconductor detectors with proximity signal readout

Semiconductor-based radiation detectors are routinely used for the detection, imaging, and spectroscopy of x-rays, gamma rays, and charged particles for applications in the areas of nuclear and medical physics, astrophysics, environmental remediation, nuclear nonproliferation, and homeland security. Detectors used for imaging and particle tracking are more complex in that they typically must also measure the location of the radiation interaction in addition to the deposited energy. In such detectors, the position measurement is often achieved by dividing or segmenting the electrodes into many strips or pixels and then reading out the signals from all of the electrode segments. Fine electrode segmentation is problematic for many of the standard semiconductor detector technologies. Clearly there is a need for a semiconductor-based radiation detector technology that can achieve fine position resolution while maintaining the excellent energy resolution intrinsic to semiconductor detectors, can be fabricated through simple processes, does not require complex electrical interconnections to the detector, and can reduce the number of required channels of readout electronics. Proximity electrode signal readout (PESR), in which the electrodes are not in physical contact with the detector surface, satisfies this need.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Working Group Report: Sensors

Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges.

HEP↗

Application of pixel-cell detector technology for Advanced Neutron Beam Monitors

Application of Pixel-Cell Detector Technology for Advanced Neutron Beam Monitors Specifications of currently available neutron beam detectors limit their usefulness at intense neutron beams of large-scale national user facilities used for the advanced study of materials. A large number of neutron-scattering experiments require beam monitors to operate in an intense neutron beam flux of >10E+7 neutrons per second per square centimeter. For instance, a 4 cm x 4 cm intense beam flux of 6.25 x 10E+7 n/s/cm2 at the Spallation Neutron Source will put a flux of 1.00 x 10E+9 n/s at the beam monitor. Currently available beam monitors with a typical efficiency of 1 x 10E-4 will need to be replaced in less than two years of operation due to wire and gas degradation issues. There is also a need at some instruments for beam position information that are beyond the capabilities of currently available He-3 and BF3 neutron beam monitors. ORDELA, Inc.’s research under USDOE SBIR Grant (DE-FG02-07ER84844) studied the feasibility of using pixel-cell technology for developing a new generation of stable, long-life neutron beam monitors. The research effort has led to the development and commercialization of advanced neutron beam detectors that will directly benefit the Spallation Neutron Source and other intense neutron sources such as the High Flux Isotope Reactor. A prototypical Pixel-Cell Neutron Beam Monitor was designed and constructed during this research effort. This prototype beam monitor was exposed to an intense neutron beam at the HFIR SNS HB-2 test beam site. Initial measurements on efficiency, uniformity across the detector, and position resolution yielded excellent results. The development and test results have provided the required data to initiate the fabrication and commercialization of this next generation of neutron-detector systems. ORDELA, Inc. has (1) identified low-cost design and fabrication strategies, (2) developed and built pixel-cell detectors and instrumented a 64-pixel-cell detector to specifications for the Cold-Neutron Chopper Spectrometer and POWGEN instruments, (3) investigated the general characteristics of this technology, (4) studied pixel-cell configurations and arrived at an optimized modular design, and (5) evaluated fabrication costs of mass production for these configurations. The resulting technology will enable a complete line of pixel-cell-based neutron detectors to be commercially under available. ORDELA, Inc has a good track history of application of innovative technology into the marketplace. Our commercialization record reflects this. For additional information, please contact Daniel Kopp at ORDELA, Inc. at +1 (865) 483-8675 or check our website at www.ordela.com.

36 MATERIALS SCIENCE↗

Sensor Compendium: A Snowmass Whitepaper

Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Great Pyramid: Stand-Alone Monte Carlo Simulations for Detector Optimization

Cosmic-ray muon imaging has been used to non-destructively examine the Pyramids of Khufu and Khafre on the Giza Plateau; the EGP project will continue this line of research by undertaking a full tomographic scan of the former and, in doing so, will increase the sensitivity of the technique by upwards of two orders of magnitude. This paper details the development of stand-alone Monte Carlo simulations intended to aid in optimizing the EGP detector system. While the rectangular scintillator model considered here does provide sucient position resolution in a few specic test cases, it is not the optimal telescope design. An attempted detector modication to permit tagging of muons by their incident momenta is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Electron Diffusion and Constraining the Neutral Current $\pi^0$ Background for Single-Photon Events in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are a rising technology in the field of experimental neutrino physics. LArTPCs use ionization electrons and scintillation light to reconstruct neutrino interactions with exceptional calorimetric and position resolution capabilities. Here, I present two analyses conducted in the MicroBooNE LArTPC at Fermilab: a measurement of the longitudinal electron diffusion coefficient, $D_L$, in the MicroBooNE detector and a constraint of the systematic uncertainty on MicroBooNE's single-photon analysis due to the dominant neutral current (NC) \piz{} background. Longitudinal electron diffusion modifies the spatial and timing resolution of the detector, and measuring it will help correct for these effects. Furthermore, current measurements of $D_L$ in liquid argon are sparse and in tension with one another, making the MicroBooNE measurement especially valuable. We report a measurement of $3.74^{+0.28}_{-0.29}$ cm$^2$/s. MicroBooNE is searchin g for si ngle-photon events as a potential explanation for the MiniBooNE low-energy excess (LEE) of electron neutrino-like events, which has been interpreted as evidence for low-mass sterile neutrinos. However, this search is overwhelmed by a large NC \piz{} background. By performing a sideband selection of NC \piz{} events, we apply a data-driven rate constraint to the single-photon analysis to reduce the systematic uncertainties. At present, this constraint improves the single-photon analysis' median sensitivity to the LEE-like signal from 0.9$\sigma$ to $1.5\sigma$. This sensitivity is expected to improve significantly as more data become available. Both of these measurements will not only benefit MicroBooNE, but also inform future LArTPC experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Great Pyramid: Detector Technical Design Report with Stand-Alone Monte Carlo Simulations

Cosmic-ray muon imaging has been used to non-destructively examine the Pyramids of Khufu and Khafre on the Giza Plateau; the EGP project will continue this line of research by undertaking a full tomographic scan of the former and by doing so will increase the sensitivity of the technique by upwards of two orders of magnitude. For this purpose, a muon telescope using triangular (vernier) detector cells far outperforms one with rectangular cells, providing an angular and positional RMS improvement by a factor of 4 for the same cost per unit area. A refinement algorithm was developed to handle tracks that produce secondaries. The triangular detector yields a positional resolution for a back-projection to the center of the pyramid of less than 20 cm, ensuring that a feature large enough to be of significance will still be seen by the telescope. This method is shown to be able to accurately and precisely reconstruct tracks of muons that pass through the King s Chamber, Queen s Chamber, and Grand Gallery.

43 PARTICLE ACCELERATORS↗

Status of the Jefferson Lab Eta Factory (JEF) experiment

The Jefferson Lab Eta Factory (JEF) experiment is an experiment running in Hall D at Jefferson Lab that focuses on studying the decays of the ¿ meson. These decays provide a rich laboratory for searching for new charge conjugation violating / parity conserving (CVPC) processes, looking for hints of Beyond Standard Model physics, and probing higher order terms in Chiral Perturbation Theory. The flagship channel is the rare decay ¿ ¿ p0¿¿, the measurement of which required an upgrade to the existing equipment in Hall D. The experiment uses the GlueX detector, a fixed-target large acceptance spectrometer based on a solenoid magnet containing drift chambers for tracking charged particles and a lead-scintillator barrel calorimeter in the central region and an array of 4 × 4 × 45 cm3 lead glass blocks in the forward region for detecting neutral particles. During the last two years the inner 80×80 cm2 region of the forward calorimeter has been replaced by an array of 2 × 2 × 20 cm3 lead tungstate crystals, which provide factors of two improvement in energy and position resolution. The first round of data taking with this configuration took place this year. A first look at the data will be presented.

Taylor, Simon [Thomas Jefferson National Accelerat↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

μRWELL detector developments at Jefferson Lab for high luminosity experiments

One of the future plans at Jefferson Lab is running electron scattering experiments with large acceptance detectors at luminosities > 10^37 cm^−2 s^−1. These experiments allow the measurements of the Double Deeply Virtual Compton Scattering (DDVCS) reaction, an important physics process in the formalism of Generalized Parton Distributions, which has never been measured because of its small cross-section. The luminosity upgrade of CLAS12 or the SOLID detector makes Jefferson Lab a unique place to measure DDVCS. One of the important components of these high luminosity detectors is a tracking system that can withstand high rates of ≈ 1MHz/cm2. The recently developed Micro-Resistive Well (𝜇RWELL) detector technology is a promising option for such a tracking detector by combining good position resolutions, low material budget with simple mechanical construction, and low production costs. In this proceeding, we will discuss recent developments and studies with 𝜇RWELL detectors at Jefferson Lab for future upgrades of the CLAS12 detector to study the DDVCS reaction.

Hauenstein, Florian↗

Heavy Flavor Physics at the sPHENIX Experiment

The sPHENIX experiment is a state-of-the-art jet and heavy flavor physics detector, which successfully recorded its first Au + Au collision data at 200 GeV at the Relativistic Heavy Ion Collider (RHIC). sPHENIX will provide heavy flavor physics measurements at RHIC, covering an unexplored kinematic region and unprecedented precision, to probe the parton energy loss mechanism, parton transport coefficients in quark–gluon plasma, and the hadronization process under various medium conditions. At the center of sPHENIX, the monolithic active pixel sensor (MAPS)-based VerTeX detector (MVTX) is a high-precision silicon pixel detector. The MVTX provides excellent position resolution and the capability of operating in continuous streaming readout mode, allowing precise vertex determination and recording a large data sample, both of which are particularly crucial for heavy flavor physics measurements. In this work, we will show the general performance of heavy-flavor hadron reconstruction. In addition, we will discuss the commissioning experience with sPHENIX. Finally, we will provide the projection of b-hadron and jet observables and discuss the estimated constraints on theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of the response of ATLAS electromagnetic liquid argon calorimeters to muons

The response of the ATLAS electromagnetic calorimeter to muons has been studied in this paper. Results on signal over noise ratio, assessment of the detector response uniformity, and position resolution are presented. The possibility to study fine details of the structure of the detector through its response to muons is illustrated on a specific example. Finally, the performance obtained on muons in test-beam is used to estimate the detector uniformity and time alignment precision that will be reachable after the commissioning of the ATLAS detector with cosmic rays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Silicon photomultiplier choice for the scintillating fibre tracker in second generation proton computed tomography scanner

Scintillating fibers are capable of charged particle tracking with high position resolution, as demonstrated by the central fiber tracker of the D0 experiment. The charged particles will deposit less energy in the polystyrene scintillating fibers as opposed to a typical silicon tracker of the same thickness, while SiPM's are highly efficient at detecting photons created by the passage of the charged particle through the fibers. The current prototype of the Proton Computed Tomography (pCT) tracker uses groups of three 0.5 mm green polystyrene based scintillating fibers connected to a single SiPM, while first generation prototype tracker used Silicon strip detectors. The results of R&D for the Scintillating Fiber Tracker (SFT) as part of the pCT detector are outlined, and the premise for the selection of SiPM is discussed.

43 PARTICLE ACCELERATORS↗