Ensuring statistical reproducibility of ocean model simulations in the age of hybrid computing

Novel high performance computing systems that feature hybrid architectures require large scale code refactoring to unravel underlying exploitable parallelism. Such redesign can often be accompanied with machine-precision changes as the order of computation cannot always be maintained. For chaotic systems like climate models, these round-off level differences can grow rapidly. Systematic errors may also manifest initially as machine-precision differences. Isolating genuine round off level differences from such errors remains a challenge. Here, we apply two-sample equality of distribution tests to evaluate statistical reproducibility of the ocean model component of US Department of Energy's Energy Exascale Earth System Model (E3SM). A 2-year control simulation ensemble is compared to a modified ensemble as a test case - after a known non-bit-for-bit change in a model component is introduced - to evaluate the null hypothesis that the two ensembles are statistically indistinguishable. To quantify the false negative rates of these tests, we conduct a formal power analysis using a targeted suite of short simulation ensembles. The ensemble suite contains several perturbed ensembles, each with a progressively different climate than the baseline ensemble - obtained by perturbing the magnitude of a single model tuning parameter, the Gent and McWilliams κ, in a controlled manner. The null hypothesis is evaluated for each of perturbed ensembles using these tests. The power analysis informs on the detection limits of the tests for given ensemble size allowing model developers to evaluate the impact of an introduced non-bit-for-bit change to the model.

Mahajan, Salil↗

Co-Simulation Meets AI: MCP-Driven Power System Analysis

GridGPT, a fine-tuned Generative AI model is designed for on-premise use in grid control rooms. This presentation will demonstrate how eGridGPT can seamlessly integrate with control room solutions to offer operators, engineers, and corporate users enhanced guidance and decision support. It is to show how this innovative AI solution can improve state estimation, boost variable energy forecasting, and optimize grid operations. By leveraging eGridGPT's unique features, audience will learn to unlock new levels of automation, predictive analytics, and reliability within their power systems, ultimately leading to reduced downtime and improved operational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scaling deep learning workloads: NVIDIA DGX-1/Pascal and Intel Knights Landing

Deep Learning (DL) algorithms have become ubiquitous in data analytics. As a result, major computing vendors --- including NVIDIA, Intel, AMD, and IBM --- have architectural road-maps influenced by DL workloads. Furthermore, several vendors have recently advertised new computing products as accelerating large DL workloads. Unfortunately, it is difficult for data scientists to quantify the potential of these different products. This paper provides a performance and power analysis of important DL workloads on two major parallel architectures: NVIDIA DGX-1 (eight Pascal P100 GPUs interconnected with NVLink) and Intel Knights Landing (KNL) CPUs interconnected with Intel Omni-Path or Cray Aries. Our evaluation consists of a cross section of convolutional neural net workloads: CifarNet, AlexNet, GoogLeNet, and ResNet50 topologies using the Cifar10 and ImageNet datasets. The workloads are vendor-optimized for each architecture. Our analysis indicates that although GPUs provide the highest overall performance, the gap can close for some convolutional networks; and the KNL can be competitive in performance/watt. We find that NVLink facilitates scaling efficiency on GPUs. However, its importance is heavily dependent on neural network architecture. Furthermore, for weak-scaling --- sometimes encouraged by restricted GPU memory --- NVLink is less important.

Gawande, Nitin A.↗

Western Interconnection Baseline Study

The purpose of the baseline study is to evaluate the degree to which current industry planning processes meet the national 2035 decarbonization goals for the Western Interconnection. This analysis serves as a comparative baseline for the scenario analysis conducted in the NTP Study using a Western Interconnection dataset that is readily available to industry. This baseline analysis differs from the production cost modeling analysis and power flow analysis in the main NTP Study report (forthcoming). In particular, the analysis presented in this report reflects a business-as-usual future with an optimistic build out of specific planned transmission projects and foreseeable generation. In contrast, the NTP Study models a future generation and transmission expansion based on optimization from a capacity expansion model. The analysis presented herein also reflects a 2030 timeframe, whereas the main NTP Study production cost modeling analysis and power flow analysis reflect a 2035 time frame. This baseline analysis utilizes industry’s most reliable data to account for future transmission projects across various stages of development, with a particular focus on those in the permitting stage. Additionally, it incorporates projections for changes in generation capacity (both additions and retirements). This baseline analysis outlines a probable trajectory, given current process and practice, for the future of the bulk power system with a horizon extending to 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Gastrointestinal stromal tumor risk classification: spectral CT quantitative parameters

Purpose: To examine the value of spectral CT quantitative parameters in gastrointestinal stromal tumor (GIST) risk classification. Materials and methods: This retrospective study was approved by the institutional review board. The requirement for informed consent was signed. The authors evaluated 86 patients (30 high risk, 22 medium risk, 28 low risk, and 6 very low risk; mean age: 59 years [range 19–83 years]) with pathologically confirmed GIST who underwent plain and triple-phase contrast-enhanced CT with spectral CT imaging mode from March 2015 through September 2017, with manual follow-up. Quantitative parameters including the CT value of 70 keV monochromatic images, the slope of spectral curves, and the normalized iodine concentration (NIC) and water (iodine) concentrations were measured and calculated, and conducted a power analysis of the above data. Results: (1) The CT values at 70 keV of the high-risk group were higher than the intermediate and low groups in each of the enhanced phases (P ≤ 0.001), no significant differences in the intermediate-risk and low-risk groups were noted (P = 0.874, 0.871, 0.831, respectively). (2) The slope of the spectral curve of the high-risk group was higher than those of the intermediate and low groups in each of the enhanced phases (P ≤ 0.001), and there were no significant differences between the intermediate- and low-risk groups (P = 0.069, 0.466, 0.840, respectively). (3) The NIC of the high-risk group significantly differed from the lower risk groups (P ≤ 0.001). There was also no significant difference observed between the intermediate- and low-risk groups (P = 0.671, 0.457, 0.833, respectively). (4) The power analysis results show that only the low-risk group with delay period is 0.530, the rest groups are all greater than 0.999. Conclusion: Dual-energy spectral CT with quantitative analysis may help to increase the accuracy in differentiating the pathological risk classification of GIST between high risk and non-high risk, preoperatively. There were limitations for distinguishing the intermediate- and low-risk groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The National Transmission Planning Study: Chapter 4: AC Power Flow Analysis for 2035 Scenarios

The National Transmission Planning Study (NTP Study) was led by the U.S. Department of Energy's Grid Deployment Office, in partnership with the National Renewable Energy Laboratory and Pacific Northwest National Laboratory. The study sought to develop new national grid-scale planning tools and methods that can be used by industry, especially when planning for interregional transmission capacity needs; identify potential transmission solutions that will provide broad-scale benefits to electric customers under a wide range of potential futures; inform planning processes for regional and interregional transmission; and identify interregional and national strategies to maintain grid reliability as the grid transitions, including to a reliance on low- and zero-carbon energy resources. The NTP Study is presented as a collection of six chapters.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests of cartridges used in air-purifying respirators (APR) and powered air-purifying respirators (PAPR) commonly used at Hanford Tank Farms. The tests are conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of PAPR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed on each tank headspace source on separate days. These data represent the first PAPR cartridge testing under the recent WRPS program, as testing to date had been focused on APR cartridges. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the PAPR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of power conversion technology options for a self-powered furnace

A self-powered furnace is defined as one that imports no electricity: a power cycle integrated into the furnace generates all the electrical power needed, and the heat rejected by the power cycle contributes to space heating. This paper presents criteria for selection of suitable power generation technology for such a furnace. A weighting system was presented to assign weight to each criterion based on its importance to the success of a self-powered furnace implementation. Power generation candidates were reviewed and scored based on the selection criteria. The top five candidates were analyzed to quantitatively compare the additional heat exchange requirements they impose on a baseline furnace. Air-cooled internal combustion engines and microturbine generators had negligible impact on the heat exchange requirement compared to a baseline furnace. Liquid-cooled internal combustion engines increased the heat exchange requirement by a factor of 1.5. Thermoelectric generators and thermophotovoltaic increased the heat exchange requirement by a factor of roughly 2.5. Organic Rankine cycle increased the heat exchange requirement by a factor of 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.