Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗

Distributed optimal power flow processes for unbalanced radial distribution networks

Node controllers and power distribution networks in accordance with embodiments of the invention enable distributed power control on an unbalanced network. One embodiment includes a node controller including a distributed power control application; a plurality of node operating parameters describing the operating parameter of a node in an unbalanced network; wherein the processor is configured by the distributed power control application to: send node operating parameters to nodes in the set of at least one node; receive operating parameters from the nodes in the set of at least one node; calculate a plurality of updated node operating parameters using an iterative process to determine updated node operating parameters using the node operating parameters that describe the operating parameters of the node, and the operating parameters of the set of at least one node, where each iteration in the iterative process involves evaluation of a subproblem; and adjust node operating parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

A robust approach to chance constrained optimal power flow with renewable generation

Optimal Power Flow (OPF) dispatches controllable generation at minimum cost subject to operational constraints on generation and transmission assets. The uncertainty and variability of intermittent renewable generation is challenging current deterministic OPF approaches. Recent formulations of OPF use chance constraints to limit the risk from renewable generation uncertainty, however, these new approaches typically assume the probability distributions which characterize the uncertainty and variability are known exactly. We formulate a robust chance constrained (RCC) OPF that accounts for uncertainty in the parameters of these probability distributions by allowing them to be within an uncertainty set. The RCC OPF is solved using a cutting-plane algorithm that scales to large power systems. We demonstrate the RRC OPF on a modified model of the Bonneville Power Administration network, which includes 2209 buses and 176 controllable generators. In conclusion, deterministic, chance constrained (CC), and RCC OPF formulations are compared using several metrics including cost of generation, area control error, ramping of controllable generators, and occurrence of transmission line overloads as well as the respective computational performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Outlets: Wireless Meter and Control Systems for Plug and Process Loads

Smart outlets control the flow of power to devices plugged into them and measure their energy use. The energy use data can be accessed via an online dashboard or smartphone application, allowing the user to turn power to plug-in devices on or off based on a schedule established in the dashboard or application. This four-page resource is a fact sheet meant to educate commercial building owners on smart outlets: what they are, why we use them, and how to use them in a way that will achieve energy savings while maintaining occupant comfort. The resource also describe how to procure a smart outlet system and how to fully capture their benefits over time. This resource was developed to support the Better Buildings Alliance Plug and Process Loads Technology Research Team.

30 DIRECT ENERGY CONVERSION↗

OpenDSS-wrapper (Distribution System Co-simulator with Distributed Energy Resource Controls)

Electric grid transformation with the proliferation of distributed energy resources (DER), such as solar photovoltaic (PV), wind, advanced energy storage technologies, and electric vehicles, and the growing use of communication technologies in both transmission and distribution systems are increasing the need to capture the interactions among these systems. Advanced modeling, control, and simulation tools that can perform co-simulation of electric power systems with other domains become indispensable to accurately model these interactions. To address this need, we have developed a codebase that integrates an electric power distribution system simulator, DER models, and DER controls. The codebase is based on OpenDSS, a distribution system simulator, and an existing open source co-simulation framework called HELICS. The contribution and uniqueness of the proposed codebase is that it tailors the generic HELICS framework specifically for distribution grid-related applications. The codebase includes an OpenDSS wrapper that controls the simulation, implements advanced DER controls, and extracts power flows, voltages, and other power system element information from the the distribution network modeled in OpenDSS. Sample HELICS federates, including a federate for OpenDSS, are provided that can communicate messages through the HELICS interface. Sample federates can be modified and additional HELICS federates can be added by the user depending on their use case requirements. SEE ALSO: https://github.com/NREL/dss-cosim

Blonsky, Michael↗

Load Modeling with Smart Meter Data for Advanced Volt-VAR Optimization Applications

This paper demonstrates the creation of time-varying, end-use electric load models with electric meter data for use by advanced, model-based volt-VAR optimization (VVO) control schemes. VVO has been shown to reduce energy consumption and peak demand in the electric distribution system. Modern VVO systems use power flow models to make control decisions. In order to make optimal decisions, these models must contain accurate load models. To improve these load models, this work uses active power, reactive power, and voltage magnitude measurements from advanced metering infrastructure (AMI) in a simulated distribution feeder to create electric load models for each customer meter. Three different modeling approaches are discussed, and their effectiveness is measured by comparing the optimality of VVO solutions with a base case. The results show that the models derived from AMI data can accurately represent some end-use load behavior like total energy costs, but lose accuracy when considering more dynamic system behavior like voltage violations over small time intervals. This work helps to advance state-of-the-art, model-based VVO by providing a data-driven modeling technique which acknowledges that optimal distribution system control requires a treatment of the system which is dependent on time, voltage, and system conditions.

Thayer, Brandon L.↗

Convex Relaxation of Grid-Connected Energy Storage System Models With Complementarity Constraints in DC OPF

Including complementarity constraints in energy storage system (ESS) models in optimization problems ensure an optimal solution will not produce a physically unrealizable control strategy where there is simultaneous charging and discharging. However, the current approaches to impose complementarity constraints require the use of non-convex optimization methods. Here, we propose a convex relaxation for a common ESS model that has terms for both charging and discharging based on a penalty reformulation for use in a model predictive control (MPC) based optimal power flow (DC OPF) problem. In this approach, the complementarity constraints are omitted and a penalty term is added to the optimization objective function. For the DC OPF problem, we provide analysis for the conditions under which the convex relaxation of the complementarity constraint ensures that a solution with simultaneous ESS charging and discharging operation is suboptimal. Simulation results demonstrating ESS behavior with and without the penalty reformulation are provided for an MPC-based DC OPF problem on multiple IEEE test systems.

25 ENERGY STORAGE↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

Pulsed power to control growth of silicon nanoparticles in low temperature flowing plasmas

Low-temperature plasmas have seen increasing use for synthesizing high-quality, mono-disperse nanoparticles (NPs). Recent work has highlighted that an important process in NP growth in plasmas is particle trapping—small, negatively charged nanoparticles become trapped by the positive electrostatic potential in the plasma, even if only momentarily charged. In this article, results are discussed from a computational investigation into how pulsing the power applied to an inductively coupled plasma (ICP) reactor may be used for controlling the size of NPs synthesized in the plasma. The model system is an ICP at 1 Torr to grow silicon NPs from an Ar/SiH 4 gas mixture. This system was simulated using a two-dimensional plasma hydrodynamics model coupled to a three-dimensional kinetic NP growth and trajectory tracking model. The effects of pulse frequency and pulse duty cycle are discussed. We identified separate regimes of pulsing where particles become trapped for one pulsed cycle, a few cycles, and many cycles—each having noticeable effects on particle size distributions. For the same average power, pulsing can produce a stronger trapping potential for particles when compared to continuous wave power, potentially increasing particle mono-dispersity. Pulsing may also offer a larger degree of control over particle size for the same average power. Experimental confirmation of predicted trends is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dissipativity-based design of local and wide-area DER controls for large-scale power systems with high penetration of renewables

In this paper, an integrated and modular control design is developed for distributed energy resources (DERs) to stabilize power systems and minimize effects of load variations and intermittent generation. Traditionally, the droop control of each generator (or virtual power plant) works as a local feedback loop to track frequency during load disturbance, whereas automatic generation control (AGC) calculates control signals and sends them to each generator with the goal of matching the total generation and load in the overall system. The droop control and the AGC work separately, therefore the two controls often conflict each other. The proposed design enables us to modularly synthesize an integrated control for each of the DERs by using both local and wide-area measurements so that the controls work together in enhancing stability and performance of the power system. The design methodology admits the full nonlinear power flow equations, and it results in a data-driven control that in real-time takes into account the nonlinear power flow interactions (in terms of current angle measurements) and adaptively adjusts parameters of the controls that operate the DERs. The design framework uses the concept of passivity-short systems to analyze individual DERs and quantify their dynamic responses in such a way that the resulting system-wide implementation becomes plug-and-play. Simulations are done to demonstrate the effectiveness of the proposed methodology and design.

Harvey, Roland↗

Development of a Particle Flow Control Mechanism

The next generation of Concentrated Solar Power (CSP) systems are utilizing solid particles as the heat transfer medium. The state-of-the-art particle flow control mechanism currently utilized is the slide-gate mechanism which functions by linearly actuating a gate across a tear-drop shaped opening. The sensitivity, which is a measure of the change in mass flow rate per unit movement of the slide-gate, is 0.354 g/s-mm[1]. The slide-gate’s main shortcomings include particle lodging and particle leakage between the plates, and difficulty actuating under the pressure from the particles. The goal of a new device is to minimize or eliminate these flaws. The new proposed device functions similar to a chuck mechanism in a drill where a rotation of an outer ring produces a change in outlet area through moving “jaws” diagonally. This mechanism aims to solve the issues of the slide-gate by having the jaws on the outside of the particle flow volume to reduce the probability of particle lodging, and the jaw tips are designed to overlap as they actuate to reduce particle leakage. Additionally, the vertical orientation of the device as well as the inclined movement of the jaws allows for easier actuation of the device under pressure. Experiments involving 3D printed prototypes have been carried out, producing a max mass flowrate of about 50 g/s and a sensitivity curve with the equation 𝑦 (𝑔/𝑠) = 0.0851𝑥^2(𝑔/𝑠−𝑚𝑚2) +3.6993𝑥(𝑔/𝑠−𝑚𝑚). These experiments validated the device’s capability to address the shortcomings of the slide-gate. Currently, an aluminum model of the device is being tested at room temperature, and a stainless-steel model is being developed to be tested at 700oC, which is the expected operating temperature of the CSP system. Furthermore, simulations are on-going to predict the mass flowrate of different device configurations at room and high temperatures.

14 SOLAR ENERGY↗

Visualizing Coolant Flow in Sodium Reactor Subassemblies

Uniformity of temperature controls peak power output. Interchannel cross-flow is the principal cross-assembly energy transport mechanism. The areas of fastest flow all occur at the exterior of the assembly. Further, the fast moving region winds around the assembly in a continuous swath. This Nek5000 simulation uses an unstructured mesh with over one billion grid points, resulting in five billion degrees of freedom per time slice. High speed patches of turbulence due to vertex shedding downstream of the wires persist for about a quarter of the wire-wrap periodic length. Credits: Science: Paul Fisher and Aleks Obabko, Argonne National Laboratory. Visualization: Hank Childs and Janet Jacobsen, Lawrence Berkeley National Laboratory. This research used resources of the Argonne Leadership Computing Facility at Argonne National Laboratory, which is supported by the Office of Science of the U.S. Dept. of Energy under contract DE-AC02-06CH11357. This research was sponsored by the Department of Energy's Office of Nuclear Energy's NEAMS program.

42 ENGINEERING↗

Optimal Water-Power Flow Problem: Formulation and Distributed Optimal Solution

This paper formalizes an optimal water-power flow (OWPF) problem to optimize the use of controllable assets across power and water systems while accounting for the couplings between the two infrastructures. Tanks and pumps are optimally managed to satisfy water demand while improving power grid operations; {for the power network, an AC optimal power flow formulation is augmented to accommodate the controllability of water pumps.} Unfortunately, the physics governing the operation of the two infrastructures and coupling constraints lead to a nonconvex (and, in fact, NP-hard) problem; however, after reformulating OWPF as a nonconvex, quadratically-constrained quadratic problem, a feasible point pursuit-successive convex approximation approach is used to identify feasible and optimal solutions. In addition, a distributed solver based on the alternating direction method of multipliers enables water and power operators to pursue individual objectives while respecting the couplings between the two networks. The merits of the proposed approach are demonstrated for the case of a distribution feeder coupled with a municipal water distribution network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VSC-HVDC Interties for Urban Power Grid Enhancement

Urban power grids are facing many operational and expansion challenges to meet further demand growth and increased reliability requirements. Advanced transmission technologies have been considered by the electric utilities to effectively increase the utilization of existing infrastructure and operational flexibility. The focus of this paper is on VSC-HVDC technologies for urban power grid enhancement and modernization. First, a potential technical scheme is proposed for converting an existing AC circuit to DC operation, which could boost the power transfer capability of the critical transmission corridor and increase network operational flexibility. Second, this paper proposes three operation modes for the VSC-HVDC interties in urban power grids corresponding to normal, emergency and island operating conditions, respectively. An integrated, adaptive emergency control strategy (AEC) is proposed that can enable adaptive power flow responses of the VSC-HVDC intertie under varying system operating conditions and critical contingencies. The flexibility and effectiveness of the proposed operational principles of urban VSC-HVDC intertie and the corresponding control strategies are verified in PSCAD/EMTDC using a realistic urban power grid in China.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗