Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Installation caused flow distortion and its effect on noise from a fan designed for turbofan engines

A ground test stand was used to obtain acoustic data on a full scale prototype fan designed for quiet subsonic aircraft engines. The fan was installed in three different ways in the test stand. In two of the installations the fan was driven by a shaft in the inlet; in the third installation the fan was driven from the rear. These three installations, and the structures associated with them, resulted in various amounts of inlet flow distortion to the fan. The rear drive installation had less inlet flow distortion than the two front drive installations. Some measurements of inlet flow distortion were made and used in a blade passage noise generation theory to predict the effects of distortion on noise. Good agreement was obtained when the predicted and measured power level differences between the front drive and rear drive installations were compared.

Povinelli, F. P.↗

Design, processing, and testing of lsi arrays for space station

The design of a MOS 256-bit Random Access Memory (RAM) is discussed. Technological achievements comprise computer simulations that accurately predict performance; aluminum-gate COS/MOS devices including a 256-bit RAM with current sensing; and a silicon-gate process that is being used in the construction of a 256-bit RAM with voltage sensing. The Si-gate process increases speed by reducing the overlap capacitance between gate and source-drain, thus reducing the crossover capacitance and allowing shorter interconnections. The design of a Si-gate RAM, which is pin-for-pin compatible with an RCA bulk silicon COS/MOS memory (type TA 5974), is discussed in full. The Integrated Circuit Tester (ICT) is limited to dc evaluation, but the diagnostics and data collecting are under computer control. The Silicon-on-Sapphire Memory Evaluator (SOS-ME, previously called SOS Memory Exerciser) measures power supply drain and performs a minimum number of tests to establish operation of the memory devices. The Macrodata MD-100 is a microprogrammable tester which has capabilities of extensive testing at speeds up to 5 MHz. Beam-lead technology was successfully integrated with SOS technology to make a simple device with beam leads. This device and the scribing are discussed.

Lile, W. R.↗

Investigation of techniques for correcting ERTS data for solar and atmospheric effects

The author has identified the following significant results. The design and fabrication of five radiant power measuring instruments (RPMI) for ERTS ground truth have been completed. These instruments will be deployed in concert with ERTS overflights to obtain radiometric measurements needed to determine solar and atmospheric parameters that effect ERTS radiance measurements. With these parameters, the accuracy and capability of various procedures for transforming ERTS data into absolute target reflectance signatures will be evaluated. The RPMI is a rugged, hand-carried instrument accurately calibrated to measure both downwelling and reflected radiance within each ERTS multispectral scanner band. A foldover handle permits a quick change from wide angle global or sky irradiance measurements to narrow angle radiance measurements from sky and ground targets. These measurements yield ground truth site reflectance and permit calculation of additional parameters such as beam transmittance between spacecraft and ground, and path radiance (path reflectance).

Rogers, R. H.↗

Energy exchanges of swimming man

Three male swimmers underwent 10-min resting and 20-min swimming (breaststroke) exposures in a swimming flume. Water temperatures in separate exposures were 18, 26, and 33 C. At each water temperature the subjects rested and swam at water velocities of 0.50, 0.75, and 0.95 m/sec, which were designed to produce around 40, 70, and 100% of maximal aerobic power. Measurements were made of esophageal temperature, four skin temperatures, water temperature, heat flow from five local skin surfaces (Hatfield-Turner disks), and oxygen uptake. Calculations were made of mean area-weighted skin temperature and heat flow, metabolic rate, and heat storage. Internal body temperature changes after 20 min of swimming were related to water temperature, swimming intensity, and body composition.

Nadel, E. R.↗

A new broadband square law detector

A broadband constant law detector was developed for precision power measurements, radio metric measurements, and other applications. It has a wide dynamic range and an accurate square law response. Other desirable characteristics, which are all included in a single compact unit, are: (1) high-level dc output with immunity to ground loop problems; (2) fast response times; (3) ability to insert known time constants; and (4) good thermal stability. The detector and its performance are described in detail. The detector can be operated in a programmable system with a ten-fold increase in accuracy. The use and performance of the detector in a noise-adding radiometer system is also discussed.

Reid, M. S.↗

Classifying and monitoring water quality by use of satellite imagery

A technique is developed to eliminate the atmosphere and surface noise effects on Landsat signals of water bodies by manipulating the total signal from Landsat in such a way that only the volume reflectance is left as a residual. With the Landsat signal from a lake and the known volume reflectance for its clear water it is possible to eliminate the surface and atmospheric effects and have residual signals that are indicative only of the type and concentration of the material in other lakes. Laboratory values are more precise than field values because in the field one must contend with indirect skylight and wave action which can be removed in the laboratory. The volume reflectance of distilled water or a very clear lake approaching distilled water was determined in the laboratory by the use of the Bendix radiant power measuring instrument. The Bendix multispectral data analysis system provided a color categorized image of several hundred lakes in a Wisconsin area. These lakes were categorized for tannin and nontannin waters and for the degrees of algae, silt, weeds, and bottom effects present.

Scherz, J. P.↗

Electric vehicle power train instrumentation: Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high harmonic components contained in the current waveforms require frequency response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement requires not only adequate frequency response but must also address phase errors caused by the finite bandwidths and component characteristics involved. The implications of these problems are assessed.

Triner, J. E.↗

A 30-cm mercury ion thruster performance with a 1 kW capacitor-diode voltage multiplier beam supply

A 1 kW solar array and capacitor-diode voltage multiplier converter (S/A-CDVM) was successfully integrated with a 30 cm diameter mercury ion thruster system to provide ion beam power. Measurements were made to compare steady state and transient response performance of a conventional bridge converter with the S/A-CDVM converter used for the ion beam supply. The ability to recover from screen to accelerator arcs and promptly re-establish stable thruster performance was demonstrated. Solar array transient response to thruster arcing was measured.

Terdan, F. F.↗

DOE/NASA Mod-0A wind turbine performance

Design and operation of a large wind turbine at Clayton, New Mexico is reported. This is the first of three identical 200 kW wind turbines to be operated on electric utility networks. A comparison between its predicted and measured power versus wind speed performance is presented.

Richards, T. R.↗

Electric vehicle power train instrumentation - Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high-harmonic components contained in the current waveforms require frequency-response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement not only requires adequate frequency response but also must address phase errors caused by the finite bandwidths and component characteristics involved. This paper discusses the implications of these problems and reports on the degree to which they have been solved at Lewis Research Center.

Triner, J. E.↗

30-cm mercury ion thruster performance with a 1 kW capacitor-diode voltage multiplier beam supply

A 1 kW Solar Array and Capacitor-Diode Voltage Multiplier Converter (S/A-CDVM) has been successfully integrated with a 30 cm-diameter mercury ion thruster system to provide ion beam power. Measurements were made to compare steady state and transient response performance of a conventional bridge converter with the S/A-CDVM converter used for the ion beam supply. The ability to recover from screen to accelerator arcs and promptly re-establish stable thruster performance was demonstrated. Solar array transient response to thruster arcing was also measured.

Terdan, F. F.↗

Solar-heated bank-Marks Mississippi

Report describes air solar-energy collectors which supply 60 percent of space heating load for full-service bank. Contemporary structure supports 468 square feet of flat-plate arrays, and features onsite temperature and power measurement readouts. Air-flow collectors minimize problems experienced with conventional liquid solar equipment and eliminate need for heat exchanger for space heating.

Source record↗