Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision health”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Development of a Microlith® Catalytic Oxidizer for Exploration Trace Contaminant Control

The state-of-the-art in long mission duration spacecraft trace contaminant control processes rely on high-temperature catalytic oxidation for light contaminant removal. Target compounds for oxidation include metabolic methane, carbon monoxide, and low molecular weight volatile organics such as formaldehyde and methanol. Precision Combustion, Inc. and NASA Marshall Space Flight Center have been developing and testing prototype high temperature catalytic oxidizers based on PCI’s patented Microlith® technology to meet the requirements of future spaceflight exploration missions. To this end, our latest generation Microlith oxidizer, featuring an integrated heat recuperator, was subjected to endurance testing to simulate catalyst ageing over a Mars transit mission duration. Periodic reactor health testing indicates our approach results in a robust contaminant control solution for exploration missions beyond low earth orbit. Based on the demonstrated performance of this unit, a next-generation prototype was designed to meet exploration contaminant load control demands while upgrading the prototype form and fit to match flight-compatible interfaces. Prototype design considerations intended to reduce power consumption, impacting process thermal and hydraulic performance, are discussed herein.

Trace Contaminant Control↗

EcAMSat and BioSentinel: Autonomous Bio Nanosatellites Addressing Strategic Knowledge Gaps for Manned Spaceflight Beyond LEO

Manned missions beyond low Earth orbit (LEO) require that several strategic knowledge gaps about the effects of space travel on the human body be addressed. NASA Ames Research Center has been the leader in developing autonomous bio nanosatellites, including past successful missions for GeneSat, PharmaSat, and O/OREOS, that tackled some of these issues. These nanosatellites provide in situ measurements, which deliver insight into the dynamic changes in cell behavior in microgravity. In this talk, two upcoming bio nanosatellites developed at Ames, the E. coli Antimicrobial Satellite (EcAMSat) and BioSentinel, will be discussed. Both satellites contain microfluidic systems that precisely deliver nutrients to the microorganisms stored within wells of fluidic cards. Each well, in turn, has its own 3-color LED and detector system which is used to monitor changes in metabolic activity with alamarBlue, a redox indicator, and the optical density of the cells. EcAMSat investigates the effects of microgravity on bacterial resistance to antimicrobial drugs, vital knowledge for understanding how to maintain the health of astronauts in long-term and beyond LEO spaceflight. The behavior of wild type and mutant uropathic E. coli will be compared in microgravity and with ground data to help understand the molecular mechanisms behind antibiotic resistance and how these phenotypes might change in space. BioSentinel seeks to directly measure the effects of space radiation on budding yeast S. cerevisiae, particularly double strand breaks (DSB). While hitching a ride on the SLS EM-1 mission (Orion's first unmanned mission to the moon) in 2018, BioSentinel will be kicked off and enter into a heliocentric orbit, becoming the first study of the effects of radiation on living organisms outside LEO since the Apollo program. The yeast are stored in eighteen independent 16-well microfluidic cards, which will be individually activated over the 12 month mission duration. In addition to the wild type and radiation-sensitive mutant strains, a BioSentinel strain of yeast has been developed, which requires a DSB to reactivate growth, thereby allowing for a direct measurement of DSBs caused by radiation. These two missions demonstrate the utility of using autonomous nanosatellites to address strategic knowledge gaps in the push to once again extend manned spaceflight beyond LEO.

Padgen, Michael R.↗

EcAMSat and BioSentinel: Autonomous Bio Nanosatellites Addressing Strategic Knowledge Gaps for Manned Spaceflight Beyond LEO

Manned missions beyond low Earth orbit (LEO) require that several strategic knowledge gaps about the effects of space travel on the human body be addressed. NASA Ames Research Center has been the leader in developing autonomous bio nanosatellites, including past successful missions for GeneSat, PharmaSat, and OOREOS, that tackled some of these issues. These nanosatellites provide in situ measurements, which deliver insight into the dynamic changes in cell behavior in microgravity. In this talk, two upcoming bio nanosatellites developed at Ames, the E. coli Antimicrobial Satellite (EcAMSat) and BioSentinel, will be discussed. Both satellites contain microfluidic systems that precisely deliver nutrients to the microorganisms stored within wells of fluidic cards. Each well, in turn, has its own 3-color LED and detector system which is used to monitor changes in metabolic activity with alamarBlue, a redox indicator, and the optical density of the cells. EcAMSat investigates the effects of microgravity on bacterial resistance to antimicrobial drugs, vital knowledge for understanding how to maintain the health of astronauts in long-term and beyond LEO spaceflight. The behavior of wild type and mutant uropathic E. coli will be compared in microgravity and with ground data to help understand the molecular mechanisms behind antibiotic resistance and how these phenotypes might change in space. BioSentinel seeks to directly measure the effects of space radiation on budding yeast S. cerevisiae, particularly double strand breaks (DSB). While hitching a ride on the SLS EM-1 mission (Orions first unmanned mission to the moon) in 2018, BioSentinel will be kicked off and enter into a heliocentric orbit, becoming the first study of the effects of radiation on living organisms outside LEO since the Apollo program. The yeast are stored in eighteen independent 16-well microfluidic cards, which will be individually activated over the 12 month mission duration. In addition to the wild type and radiation-sensitive mutant strains, a BioSentinel strain of yeast has been developed, which requires a DSB to reactivate growth, thereby allowing for a direct measurement of DSBs caused by radiation. These two missions demonstrate the utility of using autonomous nanosatellites to address strategic knowledge gaps in the push to once again extend manned spaceflight beyond LEO.

Padgen, Mike↗

Identification of mobile genetic elements with geNomad

Identifying and characterizing mobile genetic elements in sequencing data is essential for understanding their diversity, ecology, biotechnological applications and impact on public health. Here we introduce geNomad, a classification and annotation framework that combines information from gene content and a deep neural network to identify sequences of plasmids and viruses. geNomad uses a dataset of more than 200,000 marker protein profiles to provide functional gene annotation and taxonomic assignment of viral genomes. Using a conditional random field model, geNomad also detects proviruses integrated into host genomes with high precision. In benchmarks, geNomad achieved high classification performance for diverse plasmids and viruses (Matthews correlation coefficient of 77.8% and 95.3%, respectively), substantially outperforming other tools. Leveraging geNomad’s speed and scalability, we processed over 2.7 trillion base pairs of sequencing data, leading to the discovery of millions of viruses and plasmids that are available through the IMG/VR and IMG/PR databases. geNomad is available at https://portal.nersc.gov/genomad.

59 BASIC BIOLOGICAL SCIENCES↗

Near-Single-Cell Proteomics Profiling of the Proximal Tubular and Glomerulus of the Normal Human Kidney

Molecular assessments at the single-cell level can accelerate biological research by providing detailed assessments of cellular organization and tissue heterogeneity in both disease and health. The human kidney has complex multi-cellular states with varying functionality, much of which can now be completely harnessed with recent technological advances in tissue proteomics at a near single-cell level. We discuss the foundational steps in the first application of this mass spectrometry (MS) based proteomics method for analysis of sub-sections of the normal human kidney, as part of the Kidney Precision Medicine Project (KPMP). Using approximately 30-40 laser captured micro-dissected kidney cells, we identified more than 2500 human proteins, with specificity to the proximal tubular (PT; n=25 proteins) and glomerular (Glom; n=67 proteins) regions of the kidney and their unique metabolic functions. This pilot study provides the roadmap for application of our near-single-cell proteomics workflow for the analysis of other renal micro-compartments, on a larger scale, to unravel perturbations of renal sub-cellular function in the normal kidney as well as different etiologies of acute and chronic kidney disease.

60 APPLIED LIFE SCIENCES↗

Engineering design constraints of the lunar surface environment

Living and working on the lunar surface will be difficult. Design of habitats, machines, tools, and operational scenarios in order to allow maximum flexibility in human activity will require paying attention to certain constraints imposed by conditions at the surface and the characteristics of lunar material. Primary design drivers for habitat, crew health and safety, and crew equipment are: ionizing radiation, the meteoroid flux, and the thermal environment. Secondary constraints for engineering derive from: the physical and chemical properties of lunar surface materials, rock distributions and regolith thicknesses, topography, electromagnetic properties, and seismicity. Protection from ionizing radiation is essential for crew health and safety. The total dose acquired by a crew member will be the sum of the dose acquired during EVA time (when shielding will be least) plus the dose acquired during time spent in the habitat (when shielding will be maximum). Minimizing the dose acquired in the habitat extends the time allowable for EVA's before a dose limit is reached. Habitat shielding is enabling, and higher precision in predicting secondary fluxes produced in shielding material would be desirable. Means for minimizing dose during a solar flare event while on extended EVA will be essential. Early warning of the onset of flare activity (at least a half-hour is feasible) will dictate the time available to take mitigating steps. Warning capability affects design of rovers (or rover tools) and site layout. Uncertainty in solar flare timing is a design constraint that points to the need for quickly accessible or constructible safe havens.

Morrison, D. A.↗

Mid-IR UAV-based sensing platform with deep learning to Identify and Quantify Gaseous Emission in Gas Flares

This report details the development and evaluation of a Mid-Infrared (Mid-IR) Unmanned Aerial Vehicle (UAV)-based sensing platform integrated with deep learning algorithms for the identification and quantification of gaseous emissions in gas flares. The project, spearheaded by Omega Optics, Inc., aimed to address environmental monitoring challenges by leveraging advanced photonic technologies and autonomous UAV operations. The research focused on designing, optimizing, and fabricating photonic crystal waveguides and grating couplers to enhance the sensitivity and accuracy of gas detection. A comprehensive drone-based system was developed, featuring a miniaturized sensor, GPS module, and microcontroller communication network for real-time gas concentration monitoring. The system's adaptive sampling algorithm, implemented using the Robot Operating System (ROS), enables autonomous detection and localization of gas emission sources. Preliminary results demonstrate the platform's capability to detect and monitor gas emissions with high precision, cost-effectiveness, and scalability. Future work will expand upon this foundation by introducing 3D wind model-based learning for dynamic environmental conditions and further enhancing the user interface and data processing algorithms to support broader environmental monitoring applications. Overall, this project represents a significant step forward in UAV-based environmental sensing technologies, offering robust solutions for detecting and mitigating the impacts of gaseous emissions on public health and safety.

47 OTHER INSTRUMENTATION↗

Global Positioning System Energetic Particle Data: The Next Space Weather Data Revolution

The Global Positioning System (GPS) has revolutionized the process of getting from point A to point Band so much more. A large fraction of the worlds population relies on GPS (and its counterparts from other nations) for precision timing, location, and navigation. Most GPS users are unaware that the spacecraft providing the signals they rely on are operating in a very harsh space environment the radiation belts where energetic particles trapped in Earths magnetic field dash about at nearly the speed of light. These subatomic particles relentlessly pummel GPS satellites. So by design, every GPS satellite and its sensors are radiation hardened. Each spacecraft carries particle detectors that provide health and status data to system operators. Although these data reveal much about the state of the space radiation environment, heretofore they have been available only to system operators and supporting scientists. Research scientists have long sought a policy shift to allow more general access. With the release of the National Space Weather Strategy and Action Plan organized by the White House Office of Science Technology Policy (OSTP) a sample of these data have been made available to space weather researchers. Los Alamos National Laboratory (LANL) and the National Center for Environmental Information released a months worth of GPS energetic particle data from an interval of heightened space weather activity in early 2014 with the hope of stimulating integration of these data sets into the research arena. Even before the public data release GPS support scientists from LANL showed the extraordinary promise of these data.

Knipp, Delores J.↗

Optimal Stopping Ages for Colorectal Cancer Screening

Importance Prior studies have shown that the benefits, harms, and costs of colorectal cancer (CRC) screening at older ages are associated with a patient’s sex, health, and screening history. However, these studies were hypothetical exercises and not directly informed by data on CRC risk. Objective To identify the optimal stopping ages for CRC screening by sex, comorbidity, and screening history from a cost-effectiveness perspective. Design, Setting, and Participants This economic evaluation first validated the MISCAN-Colon (Microsimulation Screening Analysis–Colon) model against community-based CRC incidence and mortality rates for 2 subcohorts of the PRECISE (Optimizing Colorectal Cancer Screening Precision and Outcomes in Community-Based Populations) cohort. Subsequently, different CRC screening scenarios were simulated in older individuals. Cohorts of US adults aged 76 to 90 years varied by sex and comorbidity status (none, low, moderate, or severe). Statistical and sensitivity analyses were performed from March 2023 to May 2024. Exposures CRC screening histories including fecal immunochemical test (FIT) or colonoscopy, such as a negative colonoscopy result from 10, 15, 20, 25, or 30 years before the index age; 1 to 5 negative FIT results within 5 years of the index age, with different patterns of recency; or a combination of negative colonoscopy and negative FIT results. Main Outcomes and Measures The main outcomes included estimated lifetime clinical outcomes, incremental costs, and quality-adjusted life-years gained (QALYG) associated with 1 additional FIT or colonoscopy. Optimal stopping age for screening, defined as the oldest age for which the incremental cost-effectiveness ratio was still below the willingness-to-pay threshold of $\$$100 000 per QALYG, was evaluated. Results The first of the 2 PRECISE subcohorts used in validating the simulation model included 25 974 adults (15 060 females [58.0%]; 54.7% aged 76 to 80 years) with a negative colonoscopy result 10 years before the index date. The second subcohort consisted of 118 269 adults (67 058 females [56.7%]; 90.5% aged 76 to 80 years) with a negative FIT result 1 year before the index date. Older age, male sex, higher comorbidity levels, and recent CRC screenings were associated with reduced incremental benefit and cost-effectiveness of additional screening. For the reference cohort of 76-year-old females without comorbidities and a negative colonoscopy result 10 years before the index age, 1 additional colonoscopy cost $\$$38 226 per QALYG. For cohorts with otherwise equivalent characteristics, associated costs increased to $\$$1 689 945 per QALYG for females at age 90 years without comorbidities and a negative colonoscopy results 10 years before the index age, $\$$51 604 per QALYG for males at age 76 years without comorbidities and a negative colonoscopy result 10 years before the index age, and $\$$108 480 per QALYG for females at age 76 years with severe comorbidities and a negative colonoscopy result 10 years before the index age and decreased to $\$$16 870 per QALYG for females without comorbidities and a negative colonoscopy result 30 years before the index age. The optimal stopping ages across different cohorts ranged from younger than 76 to 86 years for colonoscopy and younger than 76 to 88 years for FIT. Conclusions and Relevance In this economic evaluation, age, sex, screening history, comorbidity, and future screening modality were associated with the clinical outcomes, cost-effectiveness, and optimal stopping age for CRC screening. These results can inform guideline development and patient-directed informed decision-making.

Harlass, Matthias [Erasmus Erasmus University Medi↗

NASA Tech Briefs, January 2011

The topics include: 1) Distributed Aerodynamic Sensing and Processing Toolbox; 2) Collaborative Supervised Learning for Sensor Networks; 3) Hazard Detection Software for Lunar Landing; 4) Onboard Nonlinear Engine Sensor and Component Fault Diagnosis and Isolation Scheme; 5) Network-Capable Application Process and Wireless Intelligent Sensors for ISHM; 6) Interface Supports Multiple Broadcast Transceivers for Flight Applications; 7) FPGA Sequencer for Radar Altimeter Applications; 8) Miniature Sapphire Acoustic Resonator - MSAR; 9) Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents; 10) SAD5 Stereo Correlation Line-Striping in an FPGA; 11) Hybrid Composite Cryogenic Tank Structure; 12) Nanoscale Deformable Optics; 13) Reliability-Based Design Optimization of a Composite Airframe Component; 14) Zinc Oxide Nanowire Interphase for Enhanced Lightweight Polymer Fiber Composites; 15) Plasma Igniter for Reliable Ignition of Combustion in Rocket Engines; 16) Wire Test Grip Fixture; 17) A Sub-Hertz, Low-Frequency Vibration Isolation Platform; 18) Carbon Nanofibers Synthesized on Selective Substrates for Nonvolatile Memory and 3D Electronics; 19) Nanoparticle/Polymer Nanocomposite Bond Coat or Coating; 20) High-Resolution Wind Measurements for Offshore Wind Energy Development; 21) Spring Tire; 22) Marsviewer 2008; 23) Mission Services Evolution Center Message Bus; 24) Major Constituents Analysis for the Vehicle Cabin Atmosphere Monitor; 25) Astronaut Health Participant Summary Application; 26) Adaption of the AMDIS Method to Flight Status on the VCAM Instrument; 27) Natural Language Interface for Safety Certification of Safety-Critical Software; 28) Cryogenic Caging for Science Instrumentation; 29) Wide-Range Neutron Detector for Space Nuclear Applications; 30) In Situ Guided Wave Structural Health Monitoring System; 31) Multiplexed Energy Coupler for Rotating Equipment; 32) Attitude Estimation in Fractionated Spacecraft Cluster Systems; 33) Full Piezoelectric Multilayer-Stacked Hybrid Actuation/Transduction Systems; 34) Active Flow Effectors for Noise and Separation Control; 35) Method and System for Temporal Filtering in Video Compression Systems; 36) Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples; 37) Multiple-Zone Diffractive Optic Element for Laser Ranging Applications; 38) Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver; 39) Two-Photon-Absorption Scheme for Optical Beam Tracking; 40) High-Sensitivity, Broad-Range Vacuum Gauge Using Nanotubes for Micromachined Cavities; 41) Wide-Field Optic for Autonomous Acquisition of Laser Link; 42) Extracting Zero-Gravity Surface Figure of a Mirror; 43) Modeling Electromagnetic Scattering From Complex Inhomogeneous Objects; 44) Visual Object Recognition and Tracking of Tools; 45) Method for Implementing Optical Phase Adjustment; 46) Visual SLAM Using Variance Grid Maps; 47) Rapid Calculation of Spacecraft Trajectories Using Efficient Taylor Series Integration; 48) Efficient Kriging Algorithms; 49) Predicting Spacecraft Trajectories by the WeavEncke Method; 50) An Augmentation of G-Guidance Algorithms; 51) Comparison of Aircraft Icing Growth Assessment Software; 52) Silicon-Germanium Voltage-Controlled Oscillator at 105 GHz; 53) Estimation of Coriolis Force and Torque Acting on Ares-1; 54) Null Lens Assembly for X-Ray Mirror Segments; and 55) High-Precision Pulse Generator.

Source record↗

High-quality Acinetobacter genomes recovered from combat wounds via metagenomic sequencing resemble cultured isolate genomes

The ability to accurately characterize wound pathogens is critical to informing clinical decisions for wound infections with complex treatment requirements. Acinetobacter baumannii is an impactful nosocomial pathogen in combat wounds and civilian hospital-acquired infections. An informed understanding of the phylogenetics and epidemiology of A. baumannii infections in military and civilian environments could guide approaches that improve antibiotic treatment regimens for both military and civilian patients. Whole-genome data for bacterial strains can be difficult to obtain due to challenges in culturing isolates from preserved military specimens. Metagenomic sequencing and assembly create opportunities for genomic analysis of pathogens directly from clinical specimens. The ability to perform comparative analyses between metagenome-derived genomes and culture-derived genomes would support a range of comparative bacterial genomic studies. Wound tissue biopsy and effluent samples from combat injuries were subjected to metagenomic sequencing and assembly. In total, 42 microbial metagenome-assembled genomes (MAGs) were obtained directly from metagenomic sequence data, 36 of which were designated “high” quality. Thirty of these genomes corresponded to Acinetobacter, with 29 mapping specifically to A. baumannii. Other observed genera included Bordetella, Citrobacter, Escherichia, and Pseudomonas. Single-copy and multi-copy orthologs were identified across Acinetobacter MAGs and publicly available isolate genomes derived from military and civilian sources. Both MAG and military isolate genomes were annotated with antimicrobial resistance data, and MAG genomes were statistically comparable to genomes obtained from isolates. Our results highlight the potential of de novo metagenome assembly for enabling high-resolution characterization directly from clinical specimens, thereby improving diagnostic precision, guiding antimicrobial stewardship, and enhancing understanding of pathogen evolution across diverse healthcare and battlefield environments.

Acinetobacter baumannii↗

Optimal Calibration of the Spitzer Space Telescope

A document discusses the focal-plane calibration of the Spitzer Space Telescope by use of the instrument pointing frame (IPF) Kalman filter, which was described in Kalman Filter for Calibrating a Telescope Focal Plane (NPO-40798), NASA Tech Briefs, Vol. 30, No. 9 (September 2006), page 62. To recapitulate: In the IPF Kalman filter, optimal estimates of both engineering and scientific focal-plane parameters are obtained simultaneously, using data taken in each focalplane survey activity. The IPF Kalman filter offers greater efficiency and economy, relative to prior calibration practice in which scientific and engineering parameters were estimated by separate teams of scientists and engineers and iterated upon each other. In the Spitzer Space Telescope application, the IPF Kalman filter was used to calibrate 56 frames for precise telescope pointing, estimate >1,500 parameters associated with focal-plane mapping, and process calibration runs involving as many as 1,338 scientific image centroids. The final typical survey calibration accuracy was found to be 0.09 arc second. The use of the IPF Kalman filter enabled a team of only four analysts to complete the calibration processing in three months. An unanticipated benefit afforded by the IPF Kalman filter was the ability to monitor health and diagnose performance of the entire end-to-end telescope-pointing system.

Bayard, David↗

The Integrated Safety-Critical Advanced Avionics Communication and Control (ISAACC) System Concept: Infrastructure for ISHM

Integrated System Health Management (ISHM) architectures for spacecraft will include hard real-time, critical subsystems and soft real-time monitoring subsystems. Interaction between these subsystems will be necessary and an architecture supporting multiple criticality levels will be required. Demonstration hardware for the Integrated Safety-Critical Advanced Avionics Communication & Control (ISAACC) system has been developed at NASA Marshall Space Flight Center. It is a modular system using a commercially available time-triggered protocol, ?Tp/C, that supports hard real-time distributed control systems independent of the data transmission medium. The protocol is implemented in hardware and provides guaranteed low-latency messaging with inherent fault-tolerance and fault-containment. Interoperability between modules and systems of modules using the TTP/C is guaranteed through definition of messages and the precise message schedule implemented by the master-less Time Division Multiple Access (TDMA) communications protocol. "Plug-and-play" capability for sensors and actuators provides automatically configurable modules supporting sensor recalibration and control algorithm re-tuning without software modification. Modular components of controlled physical system(s) critical to control algorithm tuning, such as pumps or valve components in an engine, can be replaced or upgraded as "plug and play" components without modification to the ISAACC module hardware or software. ISAACC modules can communicate with other vehicle subsystems through time-triggered protocols or other communications protocols implemented over Ethernet, MIL-STD- 1553 and RS-485/422. Other communication bus physical layers and protocols can be included as required. In this way, the ISAACC modules can be part of a system-of-systems in a vehicle with multi-tier subsystems of varying criticality. The goal of the ISAACC architecture development is control and monitoring of safety critical systems of a manned spacecraft. These systems include spacecraft navigation and attitude control, propulsion, automated docking, vehicle health management and life support. ISAACC can integrate local critical subsystem health management with subsystems performing long term health monitoring. The ISAACC system and its relationship to ISHM will be presented.

Gwaltney, David A.↗

Progress of a Cross-correlation Based Optical Strain Measurement Technique for Detecting Radial Growth on a Rotating Disk

The Aeronautical Sciences Project under NASAs Fundamental Aeronautics Program is extremely interested in the development of fault detection technologies, such as optical surface measurements in the internal parts of a flow path, for in situ health monitoring of gas turbine engines. In situ health monitoring has the potential to detect flaws, i.e. cracks in key components, such as engine turbine disks, before the flaws lead to catastrophic failure. In the present study, a cross-correlation imaging technique is investigated in a proof-of-concept study as a possible optical technique to measure the radial growth and strain field on an already cracked sub-scale turbine engine disk under loaded conditions in the NASA Glenn Research Centers High Precision Rotordynamics Laboratory. The optical strain measurement technique under investigation offers potential fault detection using an applied background consisting of a high-contrast random speckle pattern and imaging the background under unloaded and loaded conditions with a CCD camera. Spinning the cracked disk at high speeds induces an external load, resulting in a radial growth of the disk of approximately 50.8-m in the flawed region and hence, a localized strain field. When imaging the cracked disk under static conditions, the disk will appear shifted. The resulting background displacements between the two images will then be measured using the two-dimensional cross-correlation algorithms implemented in standard Particle Image Velocimetry (PIV) software to track the disk growth, which facilitates calculation of the localized strain field. In order to develop and validate this optical strain measurement technique an initial proof-of-concept experiment is carried out in a controlled environment. Using PIV optimization principles and guidelines, three potential backgrounds, for future use on the rotating disk, are developed and investigated in the controlled experiment. A range of known shifts are induced on the backgrounds; reference and data images are acquired before and after the induced shift, respectively, and the images are processed using the cross- correlation algorithms in order to determine the background displacements. The effectiveness of each background at resolving the known shift is evaluated and discussed in order to choose to the most suitable background to be implemented onto a rotating disk in the Rotordynamics Lab. Although testing on the rotating disk has not yet been performed, the driving principles behind the development of the present optical technique are based upon critical aspects of the future experiment, such as the amount of expected radial growth, disk analysis, and experimental design and are therefore addressed in the paper.

Clem, Michelle M.↗

Crack-Detection Experiments on Simulated Turbine Engine Disks in NASA Glenn Research Center's Rotordynamics Laboratory

The development of new health-monitoring techniques requires the use of theoretical and experimental tools to allow new concepts to be demonstrated and validated prior to use on more complicated and expensive engine hardware. In order to meet this need, significant upgrades were made to NASA Glenn Research Center s Rotordynamics Laboratory and a series of tests were conducted on simulated turbine engine disks as a means of demonstrating potential crack-detection techniques. The Rotordynamics Laboratory consists of a high-precision spin rig that can rotate subscale engine disks at speeds up to 12,000 rpm. The crack-detection experiment involved introducing a notch on a subscale engine disk and measuring its vibration response using externally mounted blade-tip-clearance sensors as the disk was operated at speeds up to 12 000 rpm. Testing was accomplished on both a clean baseline disk and a disk with an artificial crack: a 50.8-mm- (2-in.-) long introduced notch. The disk s vibration responses were compared and evaluated against theoretical models to investigate how successful the technique was in detecting cracks. This paper presents the capabilities of the Rotordynamics Laboratory, the baseline theory and experimental setup for the crack-detection experiments, and the associated results from the latest test campaign.

Woike, Mark R.↗

Investigation of a Cross-Correlation Based Optical Strain Measurement Technique for Detecting radial Growth on a Rotating Disk

The Aeronautical Sciences Project under NASA`s Fundamental Aeronautics Program is extremely interested in the development of novel measurement technologies, such as optical surface measurements in the internal parts of a flow path, for in situ health monitoring of gas turbine engines. In situ health monitoring has the potential to detect flaws, i.e. cracks in key components, such as engine turbine disks, before the flaws lead to catastrophic failure. In the present study, a cross-correlation imaging technique is investigated in a proof-of-concept study as a possible optical technique to measure the radial growth and strain field on an already cracked sub-scale turbine engine disk under loaded conditions in the NASA Glenn Research Center`s High Precision Rotordynamics Laboratory. The optical strain measurement technique under investigation offers potential fault detection using an applied high-contrast random speckle pattern and imaging the pattern under unloaded and loaded conditions with a CCD camera. Spinning the cracked disk at high speeds induces an external load, resulting in a radial growth of the disk of approximately 50.0-im in the flawed region and hence, a localized strain field. When imaging the cracked disk under static conditions, the disk will be undistorted; however, during rotation the cracked region will grow radially, thus causing the applied particle pattern to be .shifted`. The resulting particle displacements between the two images will then be measured using the two-dimensional cross-correlation algorithms implemented in standard Particle Image Velocimetry (PIV) software to track the disk growth, which facilitates calculation of the localized strain field. In order to develop and validate this optical strain measurement technique an initial proof-of-concept experiment is carried out in a controlled environment. Using PIV optimization principles and guidelines, three potential speckle patterns, for future use on the rotating disk, are developed and investigated in the controlled experiment. A range of known shifts are induced on the patterns; reference and data images are acquired before and after the induced shift, respectively, and the images are processed using the cross-correlation algorithms in order to determine the particle displacements. The effectiveness of each pattern at resolving the known shift is evaluated and discussed in order to choose the most suitable pattern to be implemented onto a rotating disk in the Rotordynamics Lab. Although testing on the rotating disk has not yet been performed, the driving principles behind the development of the present optical technique are based upon critical aspects of the future experiment, such as the amount of expected radial growth, disk analysis, and experimental design and are therefore addressed in the paper.

Clem, Michelle M.↗

Template Matching Approach to Signal Prediction

A new approach to signal prediction and prognostic assessment of spacecraft health resolves an inherent difficulty in fusing sensor data with simulated data. This technique builds upon previous work that demonstrated the importance of physics-based transient models to accurate prediction of signal dynamics and system performance. While models can greatly improve predictive accuracy, they are difficult to apply in general because of variations in model type, accuracy, or intended purpose. However, virtually any flight project will have at least some modeling capability at its disposal, whether a full-blown simulation, partial physics models, dynamic look-up tables, a brassboard analogue system, or simple hand-driven calculation by a team of experts. Many models can be used to develop a predict, or an estimate of the next day s or next cycle s behavior, which is typically used for planning purposes. The fidelity of a predict varies from one project to another, depending on the complexity of the simulation (i.e. linearized or full differential equations) and the level of detail in anticipated system operation, but typically any predict cannot be adapted to changing conditions or adjusted spacecraft command execution. Applying a predict blindly, without adapting the predict to current conditions, produces mixed results at best, primarily due to mismatches between assumed execution of spacecraft activities and actual times of execution. This results in the predict becoming useless during periods of complicated behavior, exactly when the predict would be most valuable. Each spacecraft operation tends to show up as a transient in the data, and if the transients are misaligned, using the predict can actually harm forecasting performance. To address this problem, the approach here expresses the predict in terms of a baseline function superposed with one or more transient functions. These transients serve as signal templates, which can be relocated in time and space against the signal background. One then has the ability to reconstruct a signal regardless of the precise timing of the transients. During operation, one applies the actual start times of spacecraft activities as they occur, and produces a reconstructed, accurate predict in real-time. This general approach is valid under two important conditions. First, the transients themselves must be time-invariant. Second, the transients must be reasonably consistent with respect to different operating points. Both of these assumptions are generally valid, but in the case of a complicated system with numerous types of overlapping transients, this approach may not be effective. Fortunately, there tend to be few transients in spacecraft telemetry of sensor quantities or low-level health and status information because these signals rarely reflect multiple different types of operation. Furthermore, if the predict is at least reasonably close to actual operation, the shift either in time, or in the operating point when the transient occurs - is likely to be small. The proposed approach considers three ways to recognize a transient. The first and most reliable is to use a different signal that identifies operating mode - often the transient will be correlated to a change in operating mode, and this change can usually be detected positively from discrete signals in spacecraft telemetry. If there is no useful mode signal, the second option is to identify the transient template by hand, and detect the onset of the transient using a curve-fitting approach. Finally, if one elects not to choose by hand, there is an option for automatic selection. This technique has been applied to sensor data from several JPL missions and industrial applications, demonstrating an improvement in accurate prediction of future behavior and early detection of system problems. This technique is applicable to practically any time-varying, quantitative sensor measurement.

Mackey, Ryan↗

Demonstration of a Porous Tube Hydroponic System to Control Plant Moisture and Growth

Accurate remote detection of plant health indicators such as moisture, plant pigment concentrations, photosynthetic flux, and other biochemicals in canopies is a major goal in plant research. Influencing factors include complex interactions between wavelength dependent absorbing and scattering features from backgrounds as well as canopy biochemical and biophysical constituents. Accurately controlling these factors in outdoor field studies is difficult. Early testing of a porous tube plant culture system has indicated that plant biomass production, biomass partitioning, and leaf moisture of plants can be controlled by precisely managing the root water potential. Managing nutrient solution chemistry can also control plant pigments, biochemical concentrations, plant biomass production, and photosynthetic rates. A test bed was developed which utilized the porous tube technology with the intent of evaluating remote sensing systems, spectral analyses procedures, gas-exchange, and fluorescence measurements for their ability to detect small differences in plant water status. Spectral analysis was able to detect small differences in the mean leaf water content between the treatments. However these small differences were not detectable in the gas-exchange or fluorescence measurements.

Dreschel, T. W.↗