Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

DAmodel: hierarchical Bayesian modelling of DA white dwarfs for spectrophotometric calibration

We use hierarchical Bayesian modelling to calibrate a network of 32 all-sky faint DA white dwarf (DA WD) spectrophotometric standards (⁠16.5 < V , 19.5⁠) alongside three CALSPEC standards, from 912 Å to 32 μm. The framework is the first of its kind to jointly infer photometric zero points and WD parameters (surface gravity log g⁠, effective temperature T eff ⁠, extinction A V ⁠, dust relation parameter R V ) by simultaneously modelling both photometric and spectroscopic data. We model panchromatic Hubble Space Telescope Wide Field Camera 3 (HST/WFC3) UVIS and IR photometry, HST/STIS UV spectroscopy, and ground-based optical spectroscopy to sub-per cent precision. Photometric residuals for the sample are the lowest yet yielding < 0.004 mag RMS on average from the UV to the NIR, achieved by jointly inferring time-dependent changes in system sensitivity and WFC3/IR count-rate nonlinearity. Our GPU-accelerated implementation enables efficient sampling via Hamiltonian Monte Carlo, critical for exploring the high-dimensional posterior space. The hierarchical nature of the model enables population analysis of intrinsic WD and dust parameters. Inferred spectral energy distributions from this model will be essential for calibrating the James Webb Space Telescope as well as next-generation surveys, including Vera Rubin Observatory’s Legacy Survey of Space and Time and the Nancy Grace Roman Space Telescope.

methods: statistical↗

Resolving femtosecond photoinduced energy flow: capture of nonadiabatic reaction pathway topography and wavepacket dynamics from photoexcitation through the conical intersection seam (Final Technical Report)

The dynamics that take place within just tens to hundreds of femtoseconds following the absorption of light by a molecule can play a critical role in how the absorbed energy is directed, allowing it to be used for a specific function or dissipated harmlessly. The form of chemical change that occurs rapidly in these molecules is called a “nonadiabatic electronic transition.” Such transitions are known to mediate energy flow in natural biological systems such as the ultraviolet photoprotection mechanism of DNA and the first step of the human vision response. Understanding how these mechanisms work precisely may help scientists achieve controlled manipulation of solar energy or optical control of a wide range of energy management functions in artificial systems. Experimental methods, however, have not yet allowed a precisely resolved and complete measurement of nonadiabatic electronic transitions. This constitutes a major obstacle to progress in the field. For progress to occur that would inform a wide body of research aiming to efficiently harness the energy of light for practical purposes, it is especially important to benchmark computational models of the molecules undergoing these rapid changes with experimental measurements, in order to learn which models are accurate. With Dept. of Energy funding, we have made strong progress towards establishing a new optical method for experimentally detecting the full nonadiabatic electronic transition. This requires having coordinated pulses of light covering the visible through the mid-infrared range of the electromagnetic spectrum that last only ten femtoseconds. We have developed a new, relatively simple approach for generating such pulses of laser light, and have incorporated them into a time-resolved spectrometer for measuring rapid changes in molecules. These tools can provide the greater precision and new types of data that are needed to benchmark computational models of molecular change and thus to make progress in the field. Our tools were tested on graphene, an excellent solid-state sample for verifying the capabilities and limitations of our instrumentation. The investment made in these tools by the Dept. of Energy Office of Science will allow new fundamental scientific understanding of energy dynamics in molecules in future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Prediction of tissue optical properties using the Monte Carlo modeling of photon transport in turbid media and integrating spheres

Monte Carlo methods are an established technique for simulating light transport in biological tissue. Integrating spheres make experimental measurements of the reflectance and transmittance of a sample straightforward and inexpensive. This work presents an extension to existing Monte Carlo photon transport methods to simulate integrating sphere experiments. Crosstalk between spheres in dual-sphere experiments is accounted for in the method. Analytical models, previous works on Monte Carlo photon transport, and experimental measurements of a synthetic tissue phantom validate this method. We present two approaches for using this method to back-calculate the optical properties of samples. Experimental and simulation uncertainties are propagated through both methods. Both back-calculation methods find the optical properties of a sample accurately and precisely. Our model is implemented in standard Python 3 and CUDA C++ [J. Nickolls, I. Buck, M. Garland, and K. Skadron, ACM Queue 6 , 40 ( 2008 ) ] and is publicly available in Code 1.

Cook, Patrick D. (ORCID:0000000279345428)↗

The Tidal Clock Effects of the Lunisolar Gravitational Field and the Earth’s Tidal Deformation

State-of-the-art atomic and optical clocks have the great potential to precisely test fundamental physical assumptions and enhance our understanding of nature. Their widespread applications require us to rigorously deduce the relativistic frequency shift in the framework of general relativity. One interesting question for clocks is tidal field effect which contains variously periodic variations. By introducing tidally deformed Earth, the general algorithms for clock and frequency comparisons are derived. We investigate the effects of external gravitational bodies and Earth’s tidal deformation on the ground- and space-based clocks. The orbital elements of satellite and locations of laboratory are introduced for corresponding clocks, in which the secular and long-period terms and short-period terms are subsequently presented. These effects called tidal clock effects produce the non-negligible contributions in the modern clock experiments and can be directly evaluated from our parameterized formulas. In addition, we also demonstrate for tidal clock effects the position and distance dependences, as well as periodicity. These tidal effects and dependences can provide valuable information for the clock comparison experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanometer Resolution Structure‐Emission Correlation of Individual Quantum Emitters via Enhanced Cathodoluminescence in Twisted Hexagonal Boron Nitride

Understanding the atomic structure of quantum emitters, often originating from point defects or impuritie, is essential for designing and optimizing materials for quantum technologies such as quantum computing, communication, and sensing. Despite the availability of atomic-resolution scanning transmission electron microscopy and nanoscale cathodoluminescence microscopy, experimentally determining the atomic structure of individual emitters is challenging due to the conflicting needs for thick samples to generate strong cathodoluminescence signals and thin samples for structural analysis. To overcome this challenge, significantly enhanced cathodoluminescence at twisted interfaces is leveraged to achieve sub-nanometer localization precision for the first time in mapping individual quantum emitters in carbon-implanted hexagonal boron nitride. This unprecedent spatial sensitivity, together with correlative electron energy loss spectroscopy quantitative scanning transmission electron microscopy imaging, and first principles density functional theory calculations, enables the identification of the atomic structure of the 440 nm blue emitter in hexagonal boron nitride as a substituted vertical carbon dimer. Building on the atomic structure insights, nanoscale spatially precise creation of blue emitters is demonstrated by electron beam irradiation of carbon-coated hexagonal boron nitride. This advancement in correlating atomic structures with optical properties lays the foundation for a deeper understanding and precise engineering of quantum emitters, significantly advancing the development of cutting-edge quantum information technologies.

2D material↗

Quantum-amplified global-phase spectroscopy on an optical clock transition

Optical lattice clocks are at the forefront of precision metrology, operating near a standard quantum limit set by quantum noise. Harnessing quantum entanglement offers a promising route to surpass this limit; however, there are practical difficulties in terms of scalability and measurement resolution requirements. Here we adapt the holonomic quantum gate concept to develop a new Rabi-type ‘global-phase spectroscopy’ that uses the detuning-sensitive global Aharonov–Anandan phase19. With this approach, we can demonstrate quantum-amplified time-reversal spectroscopy on an optical clock transition that achieves directly measured 2.4(7) dB metrological gain and 4.0(8) dB improvement in laser noise sensitivity beyond the standard quantum limit. To this end, we introduce rotary echo to protect the dynamics from inhomogeneities in light–atom coupling and implement a laser-noise-cancelling differential measurement through symmetric phase encoding in two nuclear spin states. Our technique is not limited by measurement resolution, scales easily because of the global nature of entangling interaction and exhibits high resilience to typical experimental imperfections. As a result, we expect it to be broadly applicable to next-generation atomic clocks and other quantum sensors approaching the fundamental quantum precision limits.

Zaporski, Leon [Massachusetts Institute of Technol↗

Temperature Control of Crystal Optics for Ultrahigh-Resolution Applications

The temperature control of crystal optics is critical for ultrahigh resolution applications such as those used in meV-resolved Inelastic Scattering. Due to the low count rate and long acquisition time of these experiments, for 1-meV energy resolution, the absolute temperature stability of the crystal optics must be maintained below 4 mK to ensure the required stability of lattice constant, thereby ensuring the energy stability of the optics. Furthermore, the temperature control with sub-mK precision enables setting the absolute temperature of individual crystal, making it possible to align the reflection energy of each crystal’s rocking curve in sub-meV resolution thereby maximizing the combined efficiency of the crystal optics. In this contribution, we report the details of an EPICS control system using PT1000 sensors, Keithley 3706A 7.5 digits sensor scanner, and Wiener MPOD LV power supply for the analyzer crystals of the Inelastic X-ray Scattering (IXS) beamline 10-ID at NSLS-II**. We were able to achieve absolute temperature stability below 1 mK and sub-meV energy alignment for several asymmetrically cut analyzer crystals. The EPICS ePID record was used for the control of the power supplies based on the PT1000 sensor input that was read with 7.5 digits accuracy from the Keithley 3706A scanner. The system enhances the performance of the meV-resolved IXS spectrometer with currently a 1.4 meV total energy resolution and unprecedented spectral sharpness for studies of atomic dynamics in a broad range of materials.

Gofron, Kaz↗

Dynamically patterning x-ray beam by a femtosecond optical laser

Modern science and technology have greatly benefitted from our ability to precisely manipulate light waves, in both their spatial and temporal degrees of freedom. In the x-ray region, however, spatial control has been virtually static mainly due to stringent requirements for realizing high-performance optical elements. The lack of dynamic spatial control of x-ray beam has prevented researchers from realizing more sophisticated use of the wave field, which has rapidly advanced in the optical region in the past decades. In this study, we propose a practical scheme to dynamically control local x-ray reflectivity of a perfect silicon crystal by a femtosecond optical laser and demonstrate a programmable spatial x-ray modulator. Our modulator aims for spatial manipulation of the x-ray amplitude and is shown to produce arbitrary grayscale patterns with spatial frequencies up to 25 per millimeter. The proposed modulation scheme opens up a platform to enable advanced x-ray sensing and imaging techniques that can fully harness the wave nature of x-rays.

47 OTHER INSTRUMENTATION↗

Ab initio polaritonic potential-energy surfaces for excited-state nanophotonics and polaritonic chemistry

Advances in nanophotonics, quantum optics, and low-dimensional materials have enabled precise control of light–matter interactions down to the nanoscale. Combining concepts from each of these fields, there is now an opportunity to create and manipulate photonic matter via strong coupling of molecules to the electromagnetic field. Toward this goal, here we demonstrate a first principles framework to calculate polaritonic excited-state potential-energy surfaces, transition dipole moments, and transition densities for strongly coupled light–matter systems. In particular, we demonstrate the applicability of our methodology by calculating the polaritonic excited-state manifold of a formaldehyde molecule strongly coupled to an optical cavity. This proof-of-concept calculation shows how strong coupling can be exploited to alter photochemical reaction pathways by influencing avoided crossings with tuning of the cavity frequency and coupling strength. Therefore, by introducing an ab initio method to calculate excited-state potential-energy surfaces, our work opens a new avenue for the field of polaritonic chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative measurement of pebble fuel anisotropy using generalized ellipsometry

The renewed development of high-temperature gas-cooled reactors has created a need to modernize pebble fuel quality control methods. One important specification in these methods is the coefficient of thermal expansion (CTE) anisotropy, which reflects graphite grain alignment and affects fuel performance. This study investigates the feasibility of using two-modulator generalized ellipsometry microscopy (2-MGEM) as a potential surrogate metric for CTE anisotropy. Graphite matrix compacts with controlled levels of anisotropy were fabricated by varying pre-pressures during forming and were subsequently characterized using both optical dilatometry and 2-MGEM. Measured responses were compared to an isotropic reference pebble produced using an industrial manufacturing process to provide a practical baseline. The resulting measurements revealed a strong quantitative correlation between the CTE anisotropy ratio and the corresponding diattenuation ratio. However, propagated measurement uncertainties in the optical method were found to limit definitive pass/fail discrimination, highlighting the need for improved precision before qualification as a quality control tool. Still, the results establish a quantitative relationship between optical and CTE anisotropy and support further development of 2-MGEM as a potential surrogate method for evaluating graphite matrix anisotropy in pebble fuel manufacturing.

Raftery, Alicia [ORNL] (ORCID:0000000259076427)↗

Multivalent optical cycling centers: towards control of polyatomics with multi-electron degrees of freedom

Optical control of polyatomic molecules promises new opportunities in precision metrology and fundamental chemistry, as well as quantum information and many-body science. Contemporary experimental and theoretical efforts have mostly focused on cycling photons via excitation of a single electron localized to an alkaline earth (group 2)-like metal center. In this paper, we consider pathways towards optical cycling in polyatomic molecules with multi-electron degrees of freedom, which arise from two or more cycling electrons localized to p-block post-transition metal and metalloid (group 13, 14, and 15) centers. Here, we characterize the electronic structure and rovibrational branching of several prototypical candidates using ab initio quantum chemical methods. Despite increased internal complexity and challenging design parameters, we find several molecules possessing quasi-closed photon cycling schemes with highly diagonal, visible and near-infrared transitions. Furthermore, we identify new heuristics for engineering optically controllable and laser-coolable polyatomic molecules with multi-electron cycling centers. Our results help elucidate the interplay between hybridization, repulsion, and ionicity in optically active species and provide new directions for using polyatomic molecules with complex electronic structure as a resource for quantum science and measurement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Extreme-precision Radial-velocity Pipeline: First Radial Velocities from EXPRES

The EXtreme-PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, R = 137,500, optical spectrograph. It was recently commissioned at the 4.3 m Lowell Discovery Telescope near Flagstaff, Arizona. The spectrograph was designed with a target radial-velocity (RV) precision of 30 cm s{sup −1}. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first on-sky, optical, fiber-fed spectrograph to employ many novel techniques—including an “extended flat” fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and RV analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3 m s{sup −1} for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual rms of 0.895 m s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Ultrafast all-optical coherence of molecular electron spins in room-temperature water solution

The tunability and spatial precision of paramagnetic molecules makes them attractive for quantum sensing. However, usual microwave-based detection methods have poor temporal and spatial resolution, and optical methods compatible with room-temperature solutions have remained elusive. In this study, we utilized pump-probe polarization spectroscopy to initialize and track electron spin coherence in a molecule. Designed to efficiently couple spins to light, aqueous potassium hexachloroiridate(IV) enabled detection of few-picosecond free-induction decay at room temperature and micromolar concentrations. Viscosity was found to strongly vary decoherence lifetimes. This approach has improved the experimental time resolution by up to five orders of magnitude, making it possible to observe molecular electron spin coherence in a system that only exhibits coherence below 25 kelvin with traditional techniques.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterizing the Impact of Heliostat Size, Focus Method, and Optical Error on Concentrating Solar Tower Systems

Concentrating Solar Power (CSP) tower systems use heliostat fields to direct solar energy to a central receiver. The efficiency of the heliostat field is crucial for achieving thermal generation targets and is also the largest cost component, making up 30-40% of total project costs. Developers face a tradeoff: reducing heliostat costs may decrease optical performance and increase land use, while improving performance could raise manufacturing costs (through higher precision). The optimal design depends on land, labor, and manufacturing costs. Additionally, inherent performance limitations exist - optical errors result in larger solar images as heliostats move farther from the receiver, increasing spillage and attenuation losses. Ultimately, there exists a point where receiver design power can no longer be achieved at design conditions for a given solar field area. This point depends on key heliostat field design parameters including field layout, heliostats size, focus method, and heliostat optical error. In this work, we explore and characterize the performance trade-offs between heliostat size, focus method, and optical error using Monte Carlo ray-tracing simulations using NREL's high performance computing resources. The goal of this fundamental investigation is to understand practical heliostat design performance impacts that can be used to produce more cost-effective heliostat fields while still achieving plant thermal generation targets.