Studies of Two-Phase Gas-Liquid Flow in Microgravity

Two-phase gas-liquid flows are expected to occur in many future space operations. Due to a lack of buoyancy in the microgravity environment, two-phase flows are known to behave differently than those in earth gravity. Despite these concerns, little research has been conducted on microgravity two-phase flow and the current understanding is poor. This dissertation describes an experimental and modeling study of the characteristics of two-phase flows in microgravity. An experiment was operated onboard NASA aircraft capable of producing short periods of microgravity. In addition to high speed photographs of the flows, electronic measurements of void fraction, liquid film thickness, bubble and wave velocity, pressure drop and wall shear stress were made for a wide range of liquid and gas flow rates. The effects of liquid viscosity, surface tension and tube diameter on the behavior of these flows were also assessed. From the data collected, maps showing the occurrence of various flow patterns as a function of gas and liquid flow rates were constructed. Earth gravity two-phase flow models were compared to the results of the microgravity experiments and in some cases modified. Models were developed to predict the transitions on the flow pattern maps. Three flow patterns, bubble, slug and annular flow, were observed in microgravity. These patterns were found to occur in distinct regions of the gas-liquid flow rate parameter space. The effect of liquid viscosity, surface tension and tube diameter on the location of the boundaries of these regions was small. Void fraction and Weber number transition criteria both produced reasonable transition models. Void fraction and bubble velocity for bubble and slug flows were found to be well described by the Drift-Flux model used to describe such flows in earth gravity. Pressure drop modeling by the homogeneous flow model was inconclusive for bubble and slug flows. Annular flows were found to be complex systems of ring-like waves and a substrate film. Pressure drop was best fitted with the Lockhart- Martinelli model. Force balances suggest that droplet entrainment may be a large component of the total pressure drop.

Bousman, William Scott↗

Pressure Gradient and Gas Hold-Up in Two-Phase Flows through Porous Media in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this presentation, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and gas hold-up and compare with semi-empirical model pressure drop predictions.

Brian Motil↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar dust simulant and at high rates of particle loading. The pressure drop across the filter media was measured as a function of accumulated particle mass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media.

Sub-ambient↗

Two-Phase Flow in Packed Beds, Filters and Orifices: Summary of Findings of the Packed Bed Reactor Experiment Onboard of the International Space Station

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.

ISS↗

Optimization of a GO2/GH2 Swirl Coaxial Injector Element

An injector optimization methodology, method i, is used to investigate optimal design points for a gaseous oxygen/gaseous hydrogen (GO2/GH2) swirl coaxial injector element. The element is optimized in terms of design variables such as fuel pressure drop, DELTA P(sub f), oxidizer pressure drop, DELTA P(sub 0) combustor length, L(sub comb), and full cone swirl angle, theta, for a given mixture ratio and chamber pressure. Dependent variables such as energy release efficiency, ERE, wall heat flux, Q(sub w) injector heat flux, Q(sub inj), relative combustor weight, W(sub rel), and relative injector cost, C(sub rel), are calculated and then correlated with the design variables. An empirical design methodology is used to generate these responses for 180 combinations of input variables. Method i is then used to generate response surfaces for each dependent variable. Desirability functions based on dependent variable constraints are created and used to facilitate development of composite response surfaces representing some, or all, of the five dependent variables in terms of the input variables. Two examples illustrating the utility and flexibility of method i are discussed in detail. First, joint response surfaces are constructed by sequentially adding dependent variables. Optimum designs are identified after addition of each variable and the effect each variable has on the design is shown. This stepwise demonstration also highlights the importance of including variables such as weight and cost early in the design process. Secondly, using the composite response surface that includes all five dependent variables, unequal weights are assigned to emphasize certain variables relative to others. Here, method i is used to enable objective trade studies on design issues such as component life and thrust to weight ratio.

Tucker, P. Kevin↗

Optimization of a GO2/GH2 Impinging Injector Element

An injector optimization methodology, method i, is used to investigate optimal design points for a gaseous oxygen/gaseous hydrogen (GO2/GH2) impinging injector element. The unlike impinging element, a fuel-oxidizer- fuel (F-O-F) triplet, is optimized in terms of design variables such as fuel pressure drop, (Delta)P(sub f), oxidizer pressure drop, (Delta)P(sub o), combustor length, L(sub comb), and impingement half-angle, alpha, for a given mixture ratio and chamber pressure. Dependent variables such as energy release efficiency, ERE, wall heat flux, Q(sub w), injector heat flux, Q(sub inj), relative combustor weight, W(sub rel), and relative injector cost, C(sub rel), are calculated and then correlated with the design variables. An empirical design methodology is used to generate these responses for 163 combinations of input variables. Method i is then used to generate response surfaces for each dependent variable. Desirability functions based on dependent variable constraints are created and used to facilitate development of composite response surfaces representing some, or all, of the five dependent variables in terms of the input variables. Three examples illustrating the utility and flexibility of method i are discussed in detail. First, joint response surfaces are constructed by sequentially adding dependent variables. Optimum designs are identified after addition of each variable and the effect each variable has on the design is shown. This stepwise demonstration also highlights the importance of including variables such as weight and cost early in the design process. Secondly, using the composite response surface which includes all five dependent variables, unequal weights are assigned to emphasize certain variables relative to others. Here, method i is used to enable objective trade studies on design issues such as component life and thrust to weight ratio. Finally, specific variable weights are further increased to illustrate the high marginal cost of realizing the last increment of injector performance and thruster weight.

Tucker, P. Kevin↗

Simulated Altitude Investigation of Stewart-Warner Model 906-B Combustion Heater

An investigation has been conducted to determine thermal and pressure-drop performance and the operational characteristics of a Stewart-Warner model 906-B combustion heater. The performance tests covered a range of ventilating-air flows from 500 to 3185 pounds per hour, combustion-air pressure drops from 5 to 35 inches of water, and pressure altitudes from sea level to 41,000 feet. The operational characteristics investigated were the combustion-air flows for sustained combustion and for consistent ignition covering fuel-air ratios ranging from 0.033 to 0.10 and pressure altitudes from sea level to 45,000 feet. Rated heat output of 50,000 Btu per hour was obtained at pressure altitudes up to 27,000 feet for ventilating-air flows greater than 800 pounds per hour; rated output was not obtained at ventilating-air flow below 800 pounds per hour at any altitude. The maximum heater efficiency was found to be 60.7 percent at a fuel-air ratio of 0.050, a sea-level pressure altitude, a ventilating-air temperature of 0 F, combustion-air temperature of 14 F, a ventilating-air flow of 690 pounds per hour, and a combustion-air flow of 72.7 pounds per hour. The minimum combustion-air flow for sustained combustion at a pressure altitude of 25,000 feet was about 9 pounds per hour for fuel-air ratios between 0.037 and 0.099 and at a pressure altitude of 45,000 feet increased to 18 pounds per hour at a fuel-air ratio of 0.099 and 55 pounds per hour at a fuel-air ratio of 0.036. Combustion could be sustained at combustion-air flows above values of practical interest. The maximum flow was limited, however, by excessively high exhaust-gas temperature or high pressure drop. Both maximum and minimum combustion-air flows for consistent ignition decrease with increasing pressure altitude and the two curves intersect at a pressure altitude of approximately 25,000 feet and a combustion-air flow of approximately 28 pounds per hour.

Ebersbach, Frederick R.↗

Improved Method For Experiments In Vertical-Flow Boiling

Improved method of experimentation in boiling and adiabatic vertical flows provides for simultaneous determination of two-phase frictional pressure drop and vapor-volume fraction. Gravitational pressure drop determined from precise measurements of temperatures and differential pressures in conjunction with quick closure of valves.

Klausner, J. F.↗

The effect of catalyst length and downstream reactor distance on catalytic combustor performance

A study was made to determine the effects on catalytic combustor performance which resulted from independently varying the length of a catalytic reactor and the length available for gas-phase reactions downstream of the catalyst. Monolithic combustion catalysts from three manufacturers were tested in a combustion test rig with no. 2 diesel fuel. Catalytic reactor lengths of 2.5 and 5.4 cm, and downstream gas-phase reaction distances of 7.3, 12.4, 17.5, and 22.5 cm were evaluated. Measurements of carbon monoxide, unburned hydrocarbons, nitrogen oxides, and pressure drop were made. The catalytic-reactor pressure drop was less than 1 percent of the upstream total pressure for all test configurations and test conditions. Nitrogen oxides and unburned hydrocarbons emissions were less than 0.25 g NO2/kg fuel and 0.6 g HC/kg fuel, respectively. The minimum operating temperature (defined as the adiabatic combustion temperature required to obtain carbon monoxide emissions below a reference level of 13.6 g CO/kg fuel) ranged from 1230 K to 1500 K for the various conditions and configurations tested. The minimum operating temperature decreased with increasing total (catalytic-reactor-plus-downstream-gas-phase-reactor-zone) residence time but was independent of the relative times spent in each region when the catalytic-reactor residence time was greater than or equal to 1.4 ms.

Anderson, D.↗

Theoretical and experimental analysis of the slotted-wall flow field in a transonic wind tunnel

The flow in the vicinity of a longitudinally slotted wind-tunnel wall is theoretically analyzed, and equations describing the pressure drop across the wall are derived. The ideal form of the slotted-wall boundary condition is shown to effectively model the wall pressure drop upstream of the point of maximum model thickness providing that a zero-shift correction to the reference pressure is included in the analysis. The wall-pressure drop equations can be linearized by subtracting the tunnel-empty boundary condition. Good correlation is obtained between experimental and theoretical values for variations in Mach number and angle of attack.

Everhart, Joel L.↗

Flow tests of a single fuel element coolant channel for a compact fast reactor for space power

Water flow tests were conducted on a single-fuel-element cooling channel for a nuclear concept to be used for space power. The tests established a method for measuring coolant flow rate which is applicable to water flow testing of a complete mockup of the reference reactor. The inlet plenum-to-outlet plenum pressure drop, which approximates the overall core pressure drop, was measured and correlated with flow rate. This information can be used for reactor coolant flow and heat transfer calculations. An analytical study of the flow characteristics was also conducted.

Springborn, R. H.↗

A closed-cycle refrigerator for cooling maser amplifiers below 4 Kelvin

A helium refrigerator utilizing the Gifford-McMahon/Joule-Thomson (GM/JT) cycle was designed and tested to demonstrate the feasibility of using small closed-cycle refrigerators as an alternative to batch-filled cryostats for operating temperatures below 4 K. The systems could be used to cool low-noise microwave maser amplifiers located in large parabolic antennas. These antennas tilt vertically, making conventional liquid-filled dewars difficult to use. The system could also be used for a non-tilting beam waveguide antenna to reduce the helium consumption of a liquid helium cryostat. The prototype system is adjustable to provide 700 mW of cooling at 2.5 K to 3 W at 4.3 K. Performance of the unit is not significantly affected by physical orientation. The volume occupied by the refrigerator is less than 0.1 cu m. Two JT expansion stages are used to maximize cooling capacity per unit mass flow. The heat exchangers were designed to produce minimum pressure drop in the return gas stream. Pressure drop for the entire JT return circuit is less than 5 kpa at a mass flow of 0.06 g/sec when operating at 2.5 K.

Britcliffe, M.↗

Two-phase flow and heat transfer under low gravity

Spacelab experiment to investigate two-phase flow patterns under gravity uses a water-air mixture experiment. Air and water are circulated through the system. The quality or the mixture or air-water is controlled. Photographs of the test section are made and at the same time pressure drop across the test section is measured. The data establishes a flow regime map under reduced gravity conditions with corresponding pressure drop correlations. The test section is also equipped with an electrical resistance heater in order to allow a flow boiling experiment to be carried out using Freon II. High-speed photographs of the test section are used to determine flow patterns. The temperature gradient and pressure drop along the duct can be measured. Thus, quality change can be measured, and heat transfer calculated.

Walter Frost↗

Experimental and Computational Analysis of Unidirectional Flow Through Stirling Engine Heater Head

A high efficiency Stirling Radioisotope Generator (SRG) is being developed for possible use in long-duration space science missions. NASA s advanced technology goals for next generation Stirling convertors include increasing the Carnot efficiency and percent of Carnot efficiency. To help achieve these goals, a multi-dimensional Computational Fluid Dynamics (CFD) code is being developed to numerically model unsteady fluid flow and heat transfer phenomena of the oscillating working gas inside Stirling convertors. In the absence of transient pressure drop data for the zero mean oscillating multi-dimensional flows present in the Technology Demonstration Convertors on test at NASA Glenn Research Center, unidirectional flow pressure drop test data is used to compare against 2D and 3D computational solutions. This study focuses on tracking pressure drop and mass flow rate data for unidirectional flow though a Stirling heater head using a commercial CFD code (CFD-ACE). The commercial CFD code uses a porous-media model which is dependent on permeability and the inertial coefficient present in the linear and nonlinear terms of the Darcy-Forchheimer equation. Permeability and inertial coefficient were calculated from unidirectional flow test data. CFD simulations of the unidirectional flow test were validated using the porous-media model input parameters which increased simulation accuracy by 14 percent on average.

Wilson, Scott D.↗

Heat Pipe Vapor Dynamics

The dynamic behavior of the vapor flow in heat pipes is investigated at startup and during operational transients. The vapor is modeled as two-dimensional, compressible viscous flow in an enclosure with inflow and outflow boundary conditions. For steady-state and operating transients, the SIMPLER method is used. In this method a control volume approach is employed on a staggered grid which makes the scheme very stable. It is shown that for relatively low input heat fluxes the compressibility of the vapor flow is low and the SIMPLER scheme is suitable for the study of transient vapor dynamics. When the input heat flux is high or the process under a startup operation starts at very low pressures and temperatures, the vapor is highly compressible and a shock wave is created in the evaporator. It is shown that for a wide range of input heat fluxes, the standard methods, including the SIMPLER scheme, are not suitable. A nonlinear filtering technique, along with the centered difference scheme, are then used for shock capturing as well as for the solution of the cell Reynolds-number problem. For high heat flux, the startup transient phase involves multiple shock reflections in the evaporator region. Each shock reflection causes a significant increase in the local pressure and a large pressure drop along the heat pipe. Furthermore, shock reflections cause flow reversal in the evaporation region and flow circulations in the adiabatic region. The maximum and maximum-averaged pressure drops in different sections of the heat pipe oscillate periodically with time because of multiple shock reflections. The pressure drop converges to a constant value at steady state. However, it is significantly higher than its steady-state value at the initiation of the startup transient. The time for the vapor core to reach steady-state condition depends on the input heat flux, the heat pipe geometry, the working fluid, and the condenser conditions. However, the vapor transient time, for an Na-filled heat pipe is on the order of seconds. Depending on the time constant for the overall system, the vapor transient time may be very short. Therefore, the vapor core may be assumed to be quasi-steady in the transient analysis of a heat pipe operation.

Issacci, Farrokh↗

Some injector element detail effects on screech in hydrogen-oxygen rockets

An experimental investigation was conducted to learn more about how the specific details of a concentric tube injection element affect the screech characteristics of a hydrogen-oxygen rocket engine. The four variables investigated were (1) impingement angle, (2) oxidizer tube blunt base thickness, (3) oxidizer tube recess and extension, and (4) oxidizer tube-annulus concentricity. Tests were made using a 27.34-cm (10.77-in.) diameter heat sink combustor at nominally 300-psia chamber pressure. All of the test variables were investigated using a 157 element circular pattern injector. Additional oxidizer tube recess tests were made with a 421 element hexagonal pattern injector. Tests were conducted over the oxidant-fuel ratio range of 4 to 6. Stability evaluation for each configuration was made using the hydrogen temperature rating technique. Several element configurations were also cold flow tested using nitrogen and water as simulants. The element detail changes resulted in changes in hydrogen injector pressure drop even though the physical injection area was constant for all similar tests in both hot firing and cold flow tests. These changes in injector pressure drop produced changes in combustion stability. The data were correlated with a modified version of a previously reported injection area ratio correlation. By interpreting changes in injector pressure drop as changes in injector hydrogen flow resistance, the data were compared with a hydrogen flow response stability model and were found to be in agreement.

Hannum, N. P.↗

Internal flow measurements of the SSME fuel preburner injector element using real time neutron radiography

Due to observations of unsteady flow in the Space Shuttle Main Engine fuel preburner injector element, several flow studies have been performed. Real time neutron radiography tests were recently completed. This technique provided real time images of MiL-c-7024 and Freon-22 flow through an aluminum liquid oxygen post model at three back pressures (0, 150, and 545 psig) and pressure drops up to 1000 psid. Separated flow appeared only while operating at back pressures of 0 and 150 psig. The behavior of separated flow was similar to that observed for water in a 3x acrylic model of the LOX post. On the average, separated flow appeared to reattach near the exit of the post when the ratio of pressure drop to supply pressure was about 0.75.

Lindsay, John T.↗

Measurement of Two-Phase Flow Characteristics Under Microgravity Conditions

This paper describes the technical approach and initial results of a test program for studying two-phase annular flow under the simulated microgravity conditions of KC-135 aircraft flights. A helical coil flow channel orientation was utilized in order to circumvent the restrictions normally associated with drop tower or aircraft flight tests with respect to two-phase flow, namely spatial restrictions preventing channel lengths of sufficient size to accurately measure pressure drops. Additionally, the helical coil geometry is of interest in itself, considering that operating in a microgravity environment vastly simplifies the two-phase flows occurring in coiled flow channels under 1-g conditions for virtually any orientation. Pressure drop measurements were made across four stainless steel coil test sections, having a range of inside tube diameters (0.95 to 1.9 cm), coil diameters (25 - 50 cm), and length-to-diameter ratios (380 - 720). High-speed video photographic flow observations were made in the transparent straight sections immediately preceding and following the coil test sections. A transparent coil of tygon tubing of 1.9 cm inside diameter was also used to obtain flow visualization information within the coil itself. Initial test data has been obtained from one set of KC-135 flight tests, along with benchmark ground tests. Preliminary results appear to indicate that accurate pressure drop data is obtainable using a helical coil geometry that may be related to straight channel flow behavior. Also, video photographic results appear to indicate that the observed slug-annular flow regime transitions agree quite reasonably with the Dukler microgravity map.

Keshock, E. G.↗