Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design of a Thermal and Micrometeorite Protection System for an Unmanned Lunar Cargo Lander

The first vehicles to land on the lunar surface during the establishment phase of a lunar base will be unmanned lunar cargo landers. These landers will need to be protected against the hostile lunar environment for six to twelve months until the next manned mission arrives. The lunar environment is characterized by large temperature changes and periodic micrometeorite impacts. An automatically deployable and reconfigurable thermal and micrometeorite protection system was designed for an unmanned lunar cargo lander. The protection system is a lightweight multilayered material consisting of alternating layers of thermal and micrometeorite protection material. The protection system is packaged and stored above the lander common module. After landing, the system is deployed to cover the lander using a system of inflatable struts that are inflated using residual fuel (liquid oxygen) from the fuel tanks. Once the lander is unloaded and the protection system is no longer needed, the protection system is reconfigured as a regolith support blanket for the purpose of burying and protecting the common module, or as a lunar surface garage that can be used to sort and store lunar surface vehicles and equipment. A model showing deployment and reconfiguration of the protection system was also constructed.

Hernandez, Carlos A.↗

NASA Planetary Protection Program Overview and Update

NASA has an integrated planetary protection strategy that leverages COSPAR Policy guide-lines, workshops, scientific consensus, partnerships and international working groups to develop policy and implementation guidelines. The Oÿce of Safety and Mission Assurance, which in-cludes NASA’s Oÿce of Planetary Protection, depends on these activities to support NASA’s missions in the assurance of crew safety and mission success while protecting the public and planetary environment from harmful contamination. This report will detail the overall planetary protection policy development perspective to sup-port NASA’s upcoming mission opportunities for exploration to include crewed Mars and sam-ple return missions. NASA continues to evolve its strategies, policies, and standards. NASA’s support in the COSPAR workshop series on Refining Planetary Protection Requirements for Crewed Missions to Mars have resulted in a NASA interim directive and paved the way for the development of NASA planetary protection roadmaps. These Agency level roadmaps address technology development and testing required to fill knowledge gaps for developing responsive policy guidelines and quantitative technical standards. In addition to workshops and tech-nology management strategies, NASA is also leveraging the National Academies of Science, Engineering, and Medicine’s Committee of Planetary Protection to serve as a source of advice on planetary protection measures. Finally, the report will include how the Oÿce of Safety and Mission Assurance is incorporating planetary protection into existing and new multi-agency partnerships.

Frank Groen↗

POSSIBILITIES FOR ASSESSMENT AND OPTIMIZATION OF NPP PHYSICAL PROTECTION SYSTEMS IN UKRAINE ON THE BASIS OF NUCLEAR SAFETY ANALYSIS

The design requirements for physical protection systems currently adopted at Ukrainian NPPs were established in the middle of the nineties on the basis of deterministic analyses and expert evaluations of the vulnerabilities of reactor facilities. At the present time the in-depth assessment of the nuclear safety of Ukrainian NPPs with VVER-1000/B320 reactors has been completed using Probabilistic Safety Assessment (PSA). PSA has established and provided a qualitative assessment of the significance of the equipment for maintaining the integrity of a reactor core and preventing an abnormal radioactive release. The availability of qualitative assessments of the importance of equipment for nuclear safety allows one to assess the existing physical protection system using (1) comparative analysis: to determine whether all equipment and zones that may be affected, as established by the nuclear safety assessment, are actually included into the vital zones protected by the existing physical protection system; (2) specific analysis of dominant contributors: since nuclear safety analyses provide qualitative assessment of the equipment’s importance for safety, it is easy to select a limited group of essential equipment that makes the major contribution to safety, and (3) specific equipment analysis included in dominant emergency sets: part of the components might not be included in the essential equipment group, but it might be included in the dominant emergency sets. If some equipment is found not to be covered by the physical protection system, it is possible, using qualitative assessment of the importance of this equipment for safety, to assess the required degree of enhancement of physical protection. Such analysis will permit an assessment of the sufficiency of the existing physical protection system, to define the "tight" system areas and, therefore, to develop a justified optimization of a PPS with the objective of implementing priority upgrades to enhance safety, and using limited resources in the most effective way. The application of risk-informed approaches to assessment, and subsequent optimization of the physical protection system will permit establishing basis for the implementation of the so-called graded-protection concept.

Shcherbinin, Konstantin↗

Protective barriers and related methods

Protective barriers for protecting assets (e.g., electrical power transformers and other substation components). The protective barrier may include a lower portion and an upper portion. The lower portion may include first and second laterally spaced A-frame structures having a first protective member assembly extending between aligned legs of the respective A-frame structures on one side thereof. The first protective member assembly may include a first plurality of substantially horizontally extending protective members oriented at an angle relative to a horizontal plane. The first and second A-frame structures may have a second protective member assembly extending between aligned legs of the respective A-frame structures on an opposing side thereof. The upper portion may comprise a third protective member assembly. Methods of making a protective barrier are also disclosed.

42 ENGINEERING↗

Synopsis of the Oak Ridge Radiation Protection Research Needs Workshop

Radiation protection is foundational to harnessing the societal benefits of radiation in nuclear energy, security, and medicine applications. Significant challenges in radiation protection remain unaddressed for the nuclear fuel cycle, nuclear medicine, emergency response, national defense, and space exploration, as the United States is lacking a coherent research strategy prioritizing radiation protection mission needs and gaps in scientific knowledge to meet these needs. Research and development in the field of radiation protection calls for cooperation among governmental agencies, emergency responders, research organizations, and the academic community. Amidst atrophying national expertise in radiation protection, the Radiation Protection Research Needs Workshop was spearheaded by the Oak Ridge Associated Universities, Oak Ridge National Laboratory, and the Health Physics Society. This workshop facilitated critical dialogue among radiation stakeholders in the governmental and scientific communities, including national laboratories, academic institutions, and industry partners. The workshop featured presentations representing 12 federal agencies and breakout sessions involving the identification of scientific drivers by subject matter experts in each of the following areas: new fuel cycles/reactors, dosimetry, medical physics, instrumentation and operations, decontamination and decommissioning, space radiation, national defense, emergency response, environmental modeling, and low-dose effects. The goal of this workshop was to seek stakeholder input toward the development of a national strategic research agenda in the field of radiation protection. Consequently, the Health Physics Society has established a Special Task Force on Health Physics Research Needs, tasked with the prioritization of scientific drivers in radiation protection for the development of a national strategic research agenda.

61 RADIATION PROTECTION AND DOSIMETRY↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the Adaptive Protection of Microgrids: A Review on How to Mitigate Cyber Attacks and Communication Failures

One main challenge in the practical implementation of a microgrid is the design of an adequate protection scheme in both grid connected and islanded modes. Conventional overcurrent protection schemes face selectivity and sensitivity issues during grid and microgrid faults since the fault current level is different in both cases for the same relay. Various approaches have been implemented in the past to deal with this problem, yet the most promising ones are the implementation of adaptive protection techniques abiding by the IEC 61850 communication standard. This paper presents a critical review of existing adaptive protection schemes, the technical challenges for the use of classical protection techniques and the need for an adaptive, smart protection system. However, the risk of communication link failures and cyber security threats still remain a challenge in implementing a reliable adaptive protection scheme. A contingency is needed where a communication issue prevents the relay from adjusting to a lower current level during islanded mode. An adaptive protection scheme is proposed that utilizes energy storage (ES) and hybrid ES (HESS) already available in the network as a mechanism to source the higher fault current. Four common grid ES and HESS are reviewed for their suitability in feeding the fault while some solutions are proposed.

25 ENERGY STORAGE↗

Real-Time Hardware-in-The-Loop Implementation of Protection and Self-Healing of Microgrids

The design of a reliable protection scheme for microgrids often requires communication between protective devices and microgrid controllers. The authors have developed such a communication assisted scalable protection scheme with a self healing feature to protect a microgrid with 100% Inverter Based Resources (IBRs). The communication assisted scheme must be validated in real time with cyber physical co-simulation for successful demonstration. In this regard, the paper presents a co-simulation platform between a simulated power system model using RTDS and physical protective devices. The primary protection of the scheme is programmed in SEL 421-7 relay and backup protection is programmed in MATLAB on a generic computer acting as a microgrid controller. The IEC 61850 models are used to communicate between SEL-421-7 relay and RTDS, whereas TCP/IP communication connects the microgrid controller to RTDS. The paper’s focus is to demonstrate the co- simulation platform with communication links established using both protocols and validate the proposed scheme in real-time on the IEEE 123 node distribution feeder. The paper explains the configuration of the IEC 61850 and TCP/IP communications as the interface requires proper hardware and software setup. Furthermore, the real time performance indicates the Hardware In the Loop (HIL) framework as a competent testing environment for the developed protection scheme for microgrids.

42 ENGINEERING↗

SU-E-I-76: Matching Primary and Scattered X-Ray Spectra for Use in Calculating the Diagnostic Radiation Index of Protection

Purpose: Lightweight lead-free or lead-composite protective garments exploit k-edge interactions to attenuate scattered X-rays. Manufacturers specify the protective value of garments in terms of lead equivalence at a single kVp. This is inadequate, as the protection provided by such garments varies with radiation quality in different use conditions. We present a method for matching scattered X-ray spectra to primary X-ray spectra. The resulting primary spectra can be used to measure penetration through protective garments, and such measurements can be weighted and summed to determine a Diagnostic Radiation Index for Protection (DRIP). Methods: Scattered X-ray spectra from fluoroscopic procedures were modeled using Monte Carlo techniques in MCNP-X 2.7. Data on imaging geometry, operator position, patient size, and primary beam spectra were gathered from clinical fluoroscopy procedures. These data were used to generate scattered X-ray spectra resulting from procedural conditions. Technical factors, including kV and added filtration, that yielded primary X-ray spectra that optimally matched the generated scattered X-ray spectra were identified through numerical optimization using a sequential quadratic programming (SQP) algorithm. Results: The primary spectra generated with shape functions matched the relative flux in each bin of the scattered spectra within 5%, and half and quarter-value layers matched within 0.1%. The DRIP for protective garments can be determined by measuring the penetration through protective garments using the matched primary spectra, then calculating a weighted average according to the expected clinical use of the garment. The matched primary spectra are specified in terms of first and second half-value layers in aluminum and acrylic. Conclusion: Lead equivalence is inadequate for completely specifying the protective value of garments. Measuring penetration through a garment using full scatter conditions is very difficult. The primary spectra determined in this work allow for practical primary penetration measurements to be made with equipment readily available to clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

NASA’s Revised Planetary Protection Policy and Implementation

NASA has updated its planetary protection policy and implementation approach in response to advances in scientific understanding of solar system targets, upcoming mission opportunities for exploration and sample return, and the private sector’s emerging capability to plan missions to Earth’s Moon and Mars. In September 2021, the NASA Procedural Requirements NPR 8715.24, entitled “Planetary Protection Provisions for Robotic Extraterrestrial Missions” was released which repositions planetary protection in existing NASA mission and program management structures, introduces risk-informed decision making, expands on key roles and responsibilities for both programmatic and the Office of Safety and Mission Assurance, updates the categorization process and streamlines the planetary protection documentation approval and schedule. NASA is working on a more detailed technical standard to accompany NPR 8715.24 which will include the detailed technical requirements to address organic contamination, inadvertent impact avoidance, biological control and management, end of mission disposal and restricted Earth-Return sample safety and assurance. This report to the COSPAR community will describe the current NASA planetary protection policy and its alignment with the revised COSPAR planetary protection policy. NASA’s plans for updating the supporting “Handbook for Implementing Planetary Protection Technical Requirements” and future policies for addressing planetary protection of crewed missions will also be presented.

Planetary Protection↗

NASA's Planetary Protection Program to Assure Mission Safety and Success

NASA's planetary protection program seeks to understand and control harmful contamination of solar systems targets of exploration by terrestrial contamination and prevent harmful biological contamination of the Earth-Moon system by extraterrestrial life, should it exist. To accomplish these objective's NASA has developed a balanced safety and mission assurance strategy that leverages COSPAR Policy guidelines, workshops, scientific consensus, partnerships and international working groups to develop policy and implementation guidelines. Upcoming crewed missions to the Moon and Mars, as well as robotic missions to small solar system bodies, Europa, Titan and Mars are some of the driving activities of astrobiological interest that continue to emphasize the importance of planetary protection throughout the project life cycle.Development of a responsive and updated agency planetary protection policy has been a focus area in supporting upcoming mission opportunities for exploration to include Mars sample return and crewed mission concepts. An extensive update of this policy is underway which encompasses crewed and robotic procedural polices, a general technical requirements standard, and an implementation handbook. During this timeframe NASA has been working with the international community to develop scientific consensus, and to identify and fill in knowledge gaps for developing balanced policy guidelines, incorporation of risk informed decision making and quantitative technical standards. NASA has developed a planetary protection roadmap as a technology management strategy to track and monitor the development of each knowledge gaps. The Committee of Space Research (COSPAR) Policy on Planetary Protection and the National Academies of Science, Engineering, and Medicine's Committee of Planetary Protection are used to inform updates to the planetary protection polices and guidelines. This integrated strategy for planetary protection seeks to provide a transparent, structured approach for enabling missions, providing guidance for NASA and NASA partnered missions, and being responsive to the increased interest and activities in space exploration whilst maintaining an understanding and control of harmful contamination.

Planetary Protection↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Network coding for improving throughput in WDM optical networks with dedicated protection

Network coding (NC) has been recently emerging as an excellent technique for leveraging network efficiency. In optical networks, NC and protection appear to be a good match and indeed, NC could be effectively exploited for greater protection efficiency thanks to the opportunity of combining signals rather than duplication in the traditional approach. Motivated by this observation, we investigate the application of a simple and practical NC technique based on XOR operation to improve the network throughput in survivable optical networks. To this end, we propose the NC-based protection whose speed recovery is on a par with the conventional 1+1 dedicated protection while the capacity usage could be more efficient, paving the way for improving throughput in constrained capacity conditions. A novel mixed integer linear programming model is developed for survivable optical networks design employing the proposed NC-based protection. The model attempts to optimally determine the demands to serve, the routing for served demands and NC assignment among demands aiming at maximizing the network throughput in the constraint of bandwidth limitation. Extensive numerical evaluations on realistic topologies are provided to highlight the advantages of our NC-based protection proposal compared with the conventional dedicated protection in improving the network throughput. Encouraging results are observed when the new protection proposal based on NC could accommodate up to 30% more traffic than the conventional case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Telmisartan protects against diabetic vascular complications in a mouse model of obesity and type 2 diabetes, partially through peroxisome proliferator activated receptor-{gamma}-dependent activity

Highlights: {yields} Telmisartan, an angiotensin receptor blocker, acts as a partial PPAR{gamma} agonist. {yields} The protective effects of telmisartan against diabetic vascular injury were associated with attenuation of vascular NF{kappa}B activation and TNF {alpha}. {yields} PPAR{gamma} activity of telmisartan was involved in the normalization of vascular PPAR{gamma} downregulation in diabetic mice. {yields} We provided the first evidence indicating that PPAR{gamma} activity of telmisartan contributed to the protective effects of telmisartan against diabetic vascular complication. -- Abstract: Experimental and clinical data support the notion that peroxisome proliferator-activated receptor {gamma} (PPAR{gamma}) activation is associated with anti-atherosclerosis as well as anti-diabetic effect. Telmisartan, an angiotensin receptor blocker (ARB), acts as a partial PPAR{gamma} agonist. We hypothesized that telmisartan protects against diabetic vascular complications, through PPAR{gamma} activation. We compared the effects of telmisartan, telmisartan combined with GW9662 (a PPAR{gamma} antagonist), and losartan with no PPAR{gamma} activity on vascular injury in obese type 2 diabetic db/db mice. Compared to losartan, telmisartan significantly ameliorated vascular endothelial dysfunction, downregulation of phospho-eNOS, and coronary arterial remodeling in db/db mice. More vascular protective effects of telmisartan than losartan were associated with greater anti-inflammatory effects of telmisartan, as shown by attenuation of vascular nuclear factor kappa B (NF{kappa}B) activation and tumor necrosis factor {alpha}. Coadministration of GW9662 with telmisartan abolished the above mentioned greater protective effects of telmisartan against vascular injury than losartan in db/db mice. Thus, PPAR{gamma} activity appears to be involved in the vascular protective effects of telmisartan in db/db mice. Moreover, telmisartan, but not losartan, prevented the downregulation of vascular PPAR{gamma} in db/db mice and this effect of telmisartan was cancelled by the coadministration of GW9662. Our data provided the first evidence indicating that PPAR{gamma} activity of telmisartan contributed to the protective effects of telmisartan against diabetic vascular complication. PPAR{gamma} activity of telmisartan was involved in the normalization of vascular PPAR{gamma} downregulation in diabetic mice. Thus, telmisartan seems to exert vascular protective effects in hypertensive patients with diabetes.

60 APPLIED LIFE SCIENCES↗

Stem cell factor (SCF) protects osteoblasts from oxidative stress through activating c-Kit-Akt signaling

Highlights: • SCF receptor c-Kit is functionally expressed in primary and transformed osteoblasts. • SCF protects primary and transformed osteoblasts from H{sub 2}O{sub 2}. • SCF activation of c-Kit in osteoblasts, required for its cyto-protective effects. • c-Kit mediates SCF-induced Akt activation in cultured osteoblasts. • Akt activation is required for SCF-regulated cyto-protective effects in osteoblasts. - Abstract: Osteoblasts regulate bone formation and remodeling, and are main target cells of oxidative stress in the progression of osteonecrosis. The stem cell factor (SCF)-c-Kit pathway plays important roles in the proliferation, differentiation and survival in a range of cell types, but little is known about its functions in osteoblasts. In this study, we found that c-Kit is functionally expressed in both osteoblastic-like MC3T3-E1 cells and primary murine osteoblasts. Its ligand SCF exerted significant cyto-protective effects against hydrogen peroxide (H{sub 2}O{sub 2}). SCF activated its receptor c-Kit in osteoblasts, which was required for its cyto-protective effects against H{sub 2}O{sub 2}. Pharmacological inhibition (by Imatinib and Dasatinib) or shRNA-mediated knockdown of c-Kit thus inhibited SCF-mediated osteoblast protection. Further investigations showed that protection by SCF against H{sub 2}O{sub 2} was mediated via activation of c-Kit-dependent Akt pathway. Inhibition of Akt activation, through pharmacological or genetic means, suppressed SCF-mediated anti-H{sub 2}O{sub 2} activity in osteoblasts. In summary, we have identified a new SCF-c-Kit-Akt physiologic pathway that protects osteoblasts from H{sub 2}O{sub 2}-induced damages, and might minimize the risk of osteonecrosis caused by oxidative stress.

60 APPLIED LIFE SCIENCES↗