At least 163 records · Page 9

Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models

A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.

Mir Project↗

Quality correction factors of composite IMRT beam deliveries: Theoretical considerations

Purpose: In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k{sub Q} factors. Methods: The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k{sub Q} factor identical to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k{sub Q} factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. Results: The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V{sub cyl} which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V{sub cyl}: (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V{sub cyl}, no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. Conclusions: The use of the symmetry of the problem in the present paper leads to a valuable theorem showing that k{sub Q} factors of composite IMRT beam deliveries are close to unity under specific conditions. The theoretical limit k{sub Q{sub p{sub c{sub s{sub r,Q{sub m{sub s{sub r}{sup f{sub p}{sub c}{sub s}{sub r},f{sub m}{sub s}{sub r}}}}}}}}}=1 is determined based on the property of PCSR deliveries to provide a uniform dose in the target volume. The present approach explains recent experimental observations and proposes ideal conditions for IMRT reference dosimetry. The result of this study could potentially serve as a theoretical basis for reference dosimetry of composite IMRT beam deliveries or for routine IMRT quality assurance.

60 APPLIED LIFE SCIENCES↗

Design and characterization of a novel toroidal split-ring resonator

The design and characterization of a novel toroidal split-ring resonator (SRR) are described in detail. In conventional cylindrical SRRs, there is a large magnetic flux within the bore of the resonator. However, there also exists a non-negligible magnetic flux in the free space surrounding the resonator. The energy losses associated with this radiated power diminish the resonator’s quality factor. In the toroidal SRR, on the other hand, the magnetic field lines are strongly confined within the bore of the resonator resulting in high intrinsic quality factors and stable resonance frequencies without requiring additional electromagnetic shielding. This paper describes the design and construction of a toroidal SRR as well as an experimental investigation of its cw response in the frequency-domain and its time-domain response to a rf pulse. Additionally, the dependence of the toroidal SRR’s resonant frequency and quality factor on the strength of inductive coupling to external circuits is investigated both theoretically and experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Slow light enhanced bio sensing properties of silicon sensors

In this paper, we investigated slow light to increase sensitivity and quality factor of our recently designed bio-sensors. A finite difference time domain and Plane Wave Expansion methods are employed to figure out sensors’ performances. We proposed slow light based photonic crystal structures with elliptical cells and we obtained higher sensitivity and quality factor as previously reported. For the first proposed sensor, the results showed that quality factor increased from 570 to 723 and a detection limit below 10{sup −3}. For the second sensor, the sensitivity increased from 550 to 650 nm/RIU and the detection limit is around 10{sup −3}. These two proposed structures would offer great potential for novel compact biosensors in medical application.

36 MATERIALS SCIENCE↗

Protection layers on a superconducting microwave resonator toward a hybrid quantum system

We propose a protection scheme of a superconducting microwave resonator to realize a hybrid quantum system, where cold neutral atoms are coupled with a single microwave photon through magnetic dipole interaction at an interface inductor. The evanescent field atom trap, such as a waveguide/nanofiber atom trap, brings both surface-scattered photons and absorption-induced broadband blackbody radiation which result in quasiparticles and a low quality factor at the resonator. A proposed multiband protection layer consists of pairs of two dielectric layers and a thin nanogrid conductive dielectric layer above the interface inductor. We show numerical simulations of quality factors and reflection/absorption spectra, indicating that the proposed multilayer structure can protect a lumped-element microwave resonator from optical photons and blackbody radiation while maintaining a reasonably high quality factor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Giant resonances near the split band edges of two-dimensional photonic crystals

We conduct a numerical study on the giant optical resonances near the split photonic band edges of two-dimensional square lattices. Their quality factors are 1 order of magnitude higher than those near the regular band edges. Such enhancement results from the efficient interference of multiple Bloch waves, which minimizes light leakage from the periodic pattern of finite size. The variation of the quality factor with the pattern size is nonmonotonic for the split band edge resonance, leading to an optimal size for the maximal quality factor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress towards Nb3Sn CEBAF Injector Cryomodule

Operations at 4 K instead of 2 K have the potential to reduce the operational cost of an SRF linac by a factor of 3, if the cavity quality factor can be maintained. Cavities coated with Nb3Sn have been shown to achieve the accelerating gradients above 10 MV/m with a quality factor around 1010 at 4 K. Because such performance is already pertinent for CEBAF injector cryomodule, we are working to extend these results to CEBAF accelerator cavities envisioning coating of two CEBAF 5-cell cavities with Nb3Sn. They will be installed in an injector cryomodule and tested with beam. The progress on this path is reported in this contribution.

Eremeev, Grigory↗

Dynamic control of the asymmetric Fano resonance in side-coupled Fabry–Pérot and photonic crystal nanobeam cavities

Fano resonance is a prevailing interference phenomenon that stems from the intersection between discrete and continuum states in many fields. We theoretically and experimentally characterize the asymmetric Fano lineshape in side-coupled waveguide Fabry–Pérot and photonic crystal nanobeam cavities. The measured quality-factor of the Fano resonance before tuning is 28 100. A nanoelectromechanical systems bidirectional actuator is integrated seamlessly to control the shape of the Fano resonance through in-plane translations in two directions without sacrificing the quality-factor. The peak intensity level of the Fano resonance can be increased by 8.5 dB from 60 nW to 409 nW while the corresponding dip intensity is increased by 12.8 dB from 1 nW to 18 nW. The maximum recorded quality-factor throughout the tuning procedure is up to 32 500. Potential applications of the proposed structure include enhancing the sensitivity of sensing, reconfigurable nanophotonics devices, and on-chip intensity modulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of crystal structure on microwave dielectric properties of Li{sub 2}SrTa{sub 2(1−x)}Nb{sub 2x}O{sub 7} compounds

Highlights: • Synthesis of orthorhombic Li{sub 2}SrTa{sub 2(1−x)}Nb{sub 2x}O{sub 7} compounds • The mechanism for enhancement of quality factor by bond strength. • Deviation of τ{sub ƒ} with octahedral distortion of the compound. - Abstract: The Li{sub 2}SrTa{sub 2(1−x)}Nb{sub 2x}O{sub 7} (x = 0–1.0) with layered-perovskite type structure were synthesized by conventional solid state reaction method. The X-ray diffraction reveals that all these compounds possess orthorhombic crystal structure with Cmcm space group. B-site bond strength and B-site octahedral distortion of these compounds were calculated using bond lengths obtained from Rietveld refinement. The dielectric constant (ϵ{sub r}) decreased from 24.2 to 15.2 with increase in the Nb concentration, which was due to decrease in dielectric polarizability of compound. The non-monotonic variation in quality factor (Q × ƒ) was observed with Nb concentration. This variation of quality factor was correlated with the B-site bond strength. The B-site octahedral distortion was found to increase with Nb content, which was the major factor for increase in temperature coefficient of resonant frequency (τ{sub f}) of these compounds.

36 MATERIALS SCIENCE↗

Molybdenum-rhenium alloy based high-Q superconducting microwave resonators

Superconducting microwave resonators (SMRs) with high quality factors have become an important technology in a wide range of applications. Molybdenum-Rhenium (MoRe) is a disordered superconducting alloy with a noble surface chemistry and a relatively high transition temperature. These properties make it attractive for SMR applications, but characterization of MoRe SMR has not yet been reported. Here, we present the fabrication and characterization of SMR fabricated with a MoRe 60–40 alloy. At low drive powers, we observe internal quality-factors as high as 700 000. Temperature and power dependence of the internal quality-factors suggest the presence of the two level systems from the dielectric substrate dominating the internal loss at low temperatures. We further test the compatibility of these resonators with high temperature processes, such as for carbon nanotube chemical vapor deposition growth, and their performance in the magnetic field, an important characterization for hybrid systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Fabrication of Quantum Information Processing Devices (Final Report)

The goal of this work is to develop a wideband Josephson Parametric Amplifier (JPA) by the combination of a coplanar impedance transformer and a lumped Josephson Parametric Amplifier. Josephson Parametric Amplifiers take advantage of the nonlinear inductance of Josephson junctions and the nearly lossless superconductor circuits to achieve wave mixing and amplification with only quantum-limited added noise, which makes it a key component in quantum measurements, such as single-shot qubit measurement. However, the current JPAs generally have a relatively high quality factor and small bandwidth (around 50MHz to 100MHz), which limits their ability in measuring signals from a broad spectrum. Therefore, the work planned to use a coplanar impedance transformer to enhance the coupling between JPA and the signals, resulting in a small quality factor and large bandwidth. By decreasing the quality factor of JPA to around 3, one can achieve around 20dB gain within a bandwidth of several hundred MHz. Moreover, the wideband feature allows this device to explore the frequency dependence of the coupling between the JPA and the signals. Because the impedance transformer is based on a coplanar transmission line and requires no modifications of the lumped JPA, it is relatively straightforward to embed it in the current fabrication, package, and testing process for lumped JPA. The impedance transformer can be fabricated by liftoff or etching process with the lumped JPA together, which adds no fabrication complexity. The only difference is the size, which is around 3~5 times larger than lumped JPA. This may make the number of available chips on a single wafer lower. As for the public benefits, the development of this wideband JPA will make it possible to use just a single JPA device for multi-frequency signals, for example, the readout signals of a superconducting qubit chip with multiplexed readout bus. This would greatly decrease the demand for JPAs in quantum measurements.

42 ENGINEERING↗

Revealing the loss mechanisms of a 3D superconducting microwave cavity for use in a dark matter search

Superconducting microwave cavities have found applications in many areas including quantum computing, particle accelerators, and dark matter searches. Their extremely high quality factors translate to very narrow bandwidth, which makes them key components of sensitive detectors. In this study, we aim to understand the loss mechanisms of an aluminium cavity, with a fundamental mode frequency of about 2.5123 GHz, and how they change as the cavity material transitions from the superconducting to normal state. We found that at temperatures not much lower than the transition temperature $T_c$, losses are dominated by quasiparticle excitations and are well described by the Bardeen–Cooper–Schrieffer theory. The exponential decrease of the quasiparticle density below $T_c$ results in a 1000-fold increase of the quality factor, as well as a shift of the resonance frequency due to the change of the kinetic inductance of the superconductor. At very low temperatures, losses due to two-level systems begin to dominate giving a peak in the quality factor of about 2.76 x 10 7 at 130 mK. Understanding the loss mechanisms is invaluable, as the working temperature of the cavity may vary during operation regardless of its application.

Physics - Physics of elementary particles and fiel↗

Design of axion and axion dark matter searches based on ultra high Q SRF cavities

The Superconducting Quantum Materials and Systems center is developing searches for dark photons, axions and ALPs with the goal of improving upon the current state-of-the-art sensitivity. These efforts leverage on Fermi National Accelerator expertise on ultra-high quality factor superconducting radio frequency cavities combined with the center research on quantum technology. Here we focus on multiple axion searches that utilize ~1E10 quality factor superconducting radio frequency cavities and their resonant modes to enhance the production and/or detection of axions in the cavity volume. In addition, we present preliminary results of single-mode and multi-mode nonlinearity measurements that were carried out as part of an experimental feasibility study to gain insight on the behavior of the ultra-high quality factor resonators and the experimental RF system in the regime relevant for axion searches.

43 PARTICLE ACCELERATORS↗

Performance enhancement of medium temperature baked niobium SRF cavity by surface contamination removal

Medium temperature baking (300- 350 °C) enhances the quality factor of niobium superconducting radio frequency cavities. However, surface contamination introduced during vacuum furnace baking limits the quench field and may also degrade the quality factor of the cavity. To investigate this effect, a 1.3 GHz single-cell Nb cavity underwent mid-T baking, followed by a chemical treatment to remove the surface contaminants. Post-treatment measurements revealed a significant improvement in both the quality factor and the quench field.

Chouhan, Vijay [Fermilab] (ORCID:0000000282004931)↗

Zirconia nucleating agent on microstructural and electrical properties of a CaMgSi{sub 2}O{sub 6} diopside glass–ceramic for microwave dielectrics

Addition of different amount of zirconia (ZrO{sub 2}) nucleating agent into MgO–CaO–SiO{sub 2} system to enhance the quality factor (Q × f) of CaMgSi{sub 2}O{sub 6} diopside glass–ceramic for low sintering temperature process (from 850 to 950 °C) was carried out in this work. The microstructures, microwave dielectric properties and nucleating/growth mechanism of m-ZrO{sub 2} added CaMgSi{sub 2}O{sub 6} system were analyzed using transmission electron microscopy (TEM) and electrical property measurements. Experimental results demonstrate that a solid solution of an amorphous phase MgO–CaO–SiO{sub 2} and ZrO{sub 2} forms after melted at 1500 °C. The t-ZrO{sub 2} appears in the amorphous matrix first and then crystalline CaMgSi{sub 2}O{sub 6} particle grows up at around the boundary of t-ZrO{sub 2} after thermal treatment at 850 °C due to heterogeneous nucleating. Formation of t-ZrO{sub 2} is attributed to diffusion of Ca{sup 2+} to stabilize the m-ZrO{sub 2}. The quality factor of CaMgSi{sub 2}O{sub 6} was significantly enhanced by adding 3 wt.% m-ZrO{sub 2}, indicating that the ZrO{sub 2} nucleating agent could enhance crystallization and therefore increase the quality factor.

36 MATERIALS SCIENCE↗

Photonic crystal cavity modes in the visible range characterized by scattering spectroscopy

We fabricate L3 cavities in a silicon nitride photonic crystal, with cavity modes in the visible range. We demonstrate a noninvasive method to characterize the cavities: the sample is illuminated on its edge and the upward-scattering spectrum is measured. We determine the modes' wavelengths, polarizations, and quality factors. We find modes between 700 and 830 nm with quality factors up to 280, polarized along or perpendicular to the cavity. The tuning of the cavity characteristics by means of its geometric parameters (holes sizes and shift) is discussed. The results are analyzed and compared with numerical simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning the Coherent Propagation of Organic Exciton‐Polaritons through Dark State Delocalization

Abstract While there have been numerous reports of long‐range polariton transport at room‐temperature in organic cavities, the spatiotemporal evolution of the propagation is scarcely reported, particularly in the initial coherent sub‐ps regime, where photon and exciton wavefunctions are inextricably mixed. Hence the detailed process of coherent organic exciton‐polariton transport and, in particular, the role of dark states has remained poorly understood. Here, femtosecond transient absorption microscopy is used to directly image coherent polariton motion in microcavities of varying quality factor. The transport is found to be well‐described by a model of band‐like propagation of an initially Gaussian distribution of exciton‐polaritons in real space. The velocity of the polaritons reaches values of ≈ 0.65 × 10 6 m s −1 , substantially lower than expected from the polariton dispersion. Further, it is found that the velocity is proportional to the quality factor of the microcavity. This unexpected link between the quality‐factor and polariton velocity is suggested to be a result of varying admixing between delocalized dark and polariton states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vibrational spectra of nanowires measured using laser doppler vibrometry and STM studies of epitaxial graphene : an LDRD fellowship report.

A few of the many applications for nanowires are high-aspect ratio conductive atomic force microscope (AFM) cantilever tips, force and mass sensors, and high-frequency resonators. Reliable estimates for the elastic modulus of nanowires and the quality factor of their oscillations are of interest to help enable these applications. Furthermore, a real-time, non-destructive technique to measure the vibrational spectra of nanowires will help enable sensor applications based on nanowires and the use of nanowires as AFM cantilevers (rather than as tips for AFM cantilevers). Laser Doppler vibrometry is used to measure the vibration spectra of individual cantilevered nanowires, specifically multiwalled carbon nanotubes (MWNTs) and silver gallium nanoneedles. Since the entire vibration spectrum is measured with high frequency resolution (100 Hz for a 10 MHz frequency scan), the resonant frequencies and quality factors of the nanowires are accurately determined. Using Euler-Bernoulli beam theory, the elastic modulus and spring constant can be calculated from the resonance frequencies of the oscillation spectrum and the dimensions of the nanowires, which are obtained from parallel SEM studies. Because the diameters of the nanowires studied are smaller than the wavelength of the vibrometer's laser, Mie scattering is used to estimate the lower diameter limit for nanowires whose vibration can be measured in this way. The techniques developed in this thesis can be used to measure the vibrational spectra of any suspended nanowire with high frequency resolution Two different nanowires were measured - MWNTs and Ag{sub 2}Ga nanoneedles. Measurements of the thermal vibration spectra of MWNTs under ambient conditions showed that the elastic modulus, E, of plasma-enhanced chemical vapor deposition (PECVD) MWNTs is 37 {+-} 26 GPa, well within the range of E previously reported for CVD-grown MWNTs. Since the Ag{sub 2}Ga nanoneedles have a greater optical scattering efficiency than MWNTs, their vibration spectra was more extensively studied. The thermal vibration spectra of Ag{sub 2}Ga nanoneedles was measured under both ambient and low-vacuum conditions. The operational deflection shapes of the vibrating Ag{sub 2}Ga nanoneedles was also measured, allowing confirmation of the eigenmodes of vibration. The modulus of the crystalline nanoneedles was 84.3 {+-} 1.0 GPa. Gas damping is the dominate mechanism of energy loss for nanowires oscillating under ambient conditions. The measured quality factors, Q, of oscillation are in line with theoretical predictions of air damping in the free molecular gas damping regime. In the free molecular regime, Q{sub gas} is linearly proportional to the density and diameter of the nanowire and inversely proportional to the air pressure. Since the density of the Ag{sub 2}Ga nanoneedles is three times that of the MWNTs, the Ag{sub 2}Ga nanoneedles have greater Q at atmospheric pressures. Our initial measurements of Q for Ag{sub 2}Ga nanoneedles in low-vacuum (10 Torr) suggest that the intrinsic Q of these nanoneedles may be on the order of 1000. The epitaxial carbon that grows after heating (000{bar 1}) silicon carbide (SiC) to high temperatures (1450-1600) in vacuum was also studied. At these high temperatures, the surface Si atoms sublime and the remaining C atoms reconstruct to form graphene. X-ray photoelectron spectroscopy (XPS) and scanning tunneling microscopy (STM) were used to characterize the quality of the few-layer graphene (FLG) surface. The XPS studies were useful in confirming the graphitic composition and measuring the thickness of the FLG samples. STM studies revealed a wide variety of nanometer-scale features that include sharp carbon-rich ridges, moire superlattices, one-dimensional line defects, and grain boundaries. By imaging these features with atomic scale resolution, considerable insight into the growth mechanisms of FLG on the carbon-face of SiC is obtained.