Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIANT HEATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Nuclear light bulb

The nuclear light bulb engine is a closed cycle concept. The nuclear light bulb concept provides containment by keeping the nuclear fuel fluid mechanically suspended in a cylindrical geometry. Thermal heat passes through an internally cooled, fused-silica, transparent wall and heats hydrogen propellant. The seeded hydrogen propellant absorbs radiant energy and is expanded through a nozzle. Internal moderation was used in the configuration which resulted in a reduced critical density requirement. This result was supported by criticality experiments. A reference engine was designed that had seven cells and was sized to fit in what was then predicted to be the shuttle bay mass and volume limitations. There were studies done of nozzle throat cooling schemes to remove the radiant heat. Elements of the nuclear light bulb program included closed loop critical assembly tests done at Los Alamos with UF6 confined by argon buffer gas. It was shown that the fuel region could be seeded with constituents that would block UV radiation from the uranium plasma. A combination of calculations and experiments showed that internal moderation produced a critical mass reduction. Other aspects of the research are presented.

Latham, Tom↗

Rocket Engine Clustering and Vehicle Integration as Influenced by Base Thermal Environments

Clustered rocket engines create severe thermal environments in the base of rocket vehicle stages. Boosters burning hydrocarbon fuels experience severe radiant heating early in flight; as the plumes interact at higher altitudes, convective heating becomes significant. For hydrogen-fueled upper stages radiation is not important, but convective heating is severe during the entire stage operation. Predicted and measured heating rates are discussed. The base region thermal environments of stages with clustered engines present a variety of engine/vehicle interaction problems. Components and structures in the base region, including the rocket engines, cannot survive radiant and convective heating from engine exhausts without such remedies as protective insulation, shielding, air-scooping, and proper disposal of the fuel-rich turbine exhaust gases. Different thermal protection concepts evolve for booster and upper stages due to the differences in ground test and flight environments. Solutions to the engine/vehicle interaction and design integration problems are described.

Hopson, George D.↗

Analysis of the thermal environment and thermal response associated with thermal-acoustic testing

A method is developed for predicting the radiant heat flux distribution produced by a bank of quartz radiant heaters which accounts for the specular and diffuse effects of a flat reflector or the diffuse effects of individual parabolic reflectors. This analysis is experimentally verified for a single unreflected lamp and a single lamp with a flat reflector. Observations on the further development of this analysis and experimental validation are discussed.

Turner, T. L.↗

Radiation heat transfer calculations for space structures

A method is presented for the computation of radiant heat flux between arbitrary surfaces which permits a user defined level of accuracy. The method can be applied to directionally dependent surface properties, specular radiation, or solar illumination, and ensures conservation of energy. The method is compared with others to demonstrate its value.

Emery, A. F.↗

Experimental Observations of Aerodynamic and Heating Test on Insulating Heat Shields

Several different types of insulating heat shields have been subjected to aerodynamic tests and radiant-heating tests in order to obtain a better insight into the problems involved when the primary structure of m aerodynamically heated vehicle is substantially cooler than the exposed external surface. One of the main problems was considered to be a proper allowance for thermal expansion caused by these large temperature differences, so that undue distortion or thermal stresses would not occur in either the outer shield or the underlying structure. corrugated outer skin with suitably designed expansion joints was a feature of all the specimens tested.

Anderson, Melvin S.↗

Improved thermophotovoltaic power system

Improvements in thermophotovoltaic (TPV) system design to ease the geometry and performance requirements are discussed. A TPV system usually consists of a receiver cavity lined with reflective materials and Si solar cells. A suspended central absorber/radiator converter absorbs solar energy and heats to an equilibrium temperature of 2000-23,000 K. Radiant heat at that temperature is well matched to Si solar cell low energy excitation. An elliptical geometry cavity is described which bypasses normal cell mounting problems by having the cells fixed to a plate positioned between the loci of the cavity. Incoming concentrated solar flux is absorbed by the absorber/radiator, which emits the radiation for reflection from the cavity walls to eventually pass through the solar cell wall. Dielectric stack coatings can be used on the walls. A theoretical model was developed for the performance and verified with a laboratory apparatus. Efficiencies of nearly 30% were found practical with existing materials and technologies.

Horne, W. E.↗

Emittance and absorptance of NASA ceramic thermal barrier coating system

Spectral emittance measurements were made on a two-layer ceramic thermal barrier coating system consisting of a metal substrate, a NiCrAly bond coating and a yttria-stabilized zirconia ceramic coating. Spectral emittance data were obtained for the coating system at temperatures of 300 to 1590 K, ceramic thickness of zero to 0.076 centimeter, and wavelengths of 0.4 to 14.6 micrometers. The data were transformed into total hemispherical emittance values and correlated with respect to ceramic coating thickness and temperature using multiple regression curve fitting techniques. The results show that the ceramic thermal barrier coating system is highly reflective and significantly reduces radiation heat loads on cooled gas turbine engine components. Calculation of the radiant heat transfer within the nonisothermal, translucent ceramic coating material shows that the gas-side ceramic coating surface temperature can be used in heat transfer analysis of radiation heat loads on the coating system.

Liebert, C. H.↗

Effect of Index of Refraction on Radiation Characteristics in a Heated Absorbing, Emitting, and Scattering Layer

The index of refraction can considerably influence the temperature distribution and radiative heat flow in semitransparent materials such as some ceramics. For external radiant heating, the refractive index influences the amount of energy transmitted into the interior of the material. Emission within a material depends on the square of its refractive index, and hence this emission can be many times that for a biackbody radiating into a vacuum. Since radiation exiting through an interface into a vacuum cannot exceed that of a blackbody, there is extensive reflection at the internal surface of an interface, mostly by total internal reflection. This redistributes energy within the layer and tends to make its temperature distribution more uniform. The purpose of the present analysis is to show that, for radiative equilibrium in a gray layer with diffuse interfaces, the temperature distribution and radiative heat flux for any index of refraction can be obtained very simply from the results for an index of refraction of unity. For the situation studied here, the layer is subjected to external radiative heating incident on each of its surfaces. The material emits, absorbs, and isotropically scatters radiation. For simplicity the index of refraction is unity in the medium surrounding the layer. The surfaces of the layer are assumed diffuse. This is probably a reasonable approximation for a ceramic layer that has not been polished. When transmitted radiation or radiation emitted from the interior reaches the inner surface of an interface, the radiation is diffused and some of it thereby placed into angular directions for which there is total internal reflection. This provides a trapping effect for retaining energy within the layer and tends to equalize its temperature distribution. An analysis of temperature distributions in absorbing-emitting layers, including index of refraction effects, was developed by Gardon (1958) to predict cooling and heat treating of glass plates. The interfaces were optically smooth; the resulting specular reflections were computed from the Fresnel reflection laws. This provides a somewhat different behavior than for diffuse interfaces. A similar application was for heating that occurs in a window of a re-entry vehicle (Fowle et al., 1969). A number of recent papers (Rokhsaz and Dougherty, 1989; Ping and Lallemand, 1989; Crosbie and Shieh, 1990) further examined the effects of Fresnel boundary reflections and nonunity refractive index. Other examples of analyses of both steady and transient heat transfer to single or multiple plane layers (Amlin and Korpela, 1979; Tarshis et al., 1969) have used diffuse assumptions at the interfaces as in the present study

Siegel, R.↗

The Laser Enhanced Arc-Jet Facility (LEAF-Lite): Simulating Convective and Radiative Heating with Arc-Jets and Multiple 50-KW CW Lasers

LEAF-Lite (Laser Enhanced Arc-Jet Facility) is a radiative laser heating facility that has been added to the 60 MW Interaction Heating Facility (IHF) convective plasma arc-jet located at NASA Ames Research Center. Together, these two systems can simulate both convective and radiative heating at heat fluxes reaching 551 W/cm2 by simultaneously combining a highest measured heat flux of 160 W/cm2 convective and 391 W/cm2 radiative heating on a 152-mm x 152-mm wedge model configuration. Adding radiant heating to an existing convective facility better simulates Earth atmospheric entry from hyperbolic lunarreturn speeds. The radiative heat is provided by multiple 50-kW CW IR lasers, which is nearly uniform across the illuminated surface with a total variation less than 6%, while the convective heat is provided by a high enthalpy plasma arc-jet. In a later phase, the facility will expand to test panel test articles of 432-mm x 432-mm and provide 100 W/cm2 of radiative heating in a plasma convective flow environment. The paper describes this new combined heating capability, its current testing conditions, and the unique application of the laser system with respect to the Orion test flight lunar orbits.

Cushman, Geoff↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Heat flux sensors for burner liners and turbine blades and vanes

The technology of heat flux measurement is addressed. The development of total heat flux sensors for burner liners and also the demonstration of total and radiant heat flux sensors in a combustor test is covered. A thorough review of potential approaches is conducted including both transient and steady state measurements. Measurement of total heat flux was emphasized, consequently configurations are sought which produce minimum disturbance to the heat flux which would be present without the sensor in place. Approaches to the turbine blade and vane heat flux sensor program are discussed.

Alwang, W. G.↗

Heat Lamps Solder Solar Array Quickly

Interconnection tabs in a nine-solar-cell array have been soldered simultaneously with radiant heat. Cells and tabs are held in position for soldering by sandwiching them between compliant silicone-rubber vacuum platen and transparent polyimide sealing membrane. Heat lamps warm cells, producing smooth, flat solder joints of high quality.

Coyle, P. J.↗

Transpiring Cooling of a Scram-Jet Engine Combustion Chamber

The peak cold-wall heating rate generated in a combustion chamber of a scram-jet engine can exceed 2000 Btu/sq ft sec (approx. 2344 W/sq cm). Therefore, a very effective heat dissipation mechanism is required to sustain such a high heating load. This research focused on the transpiration cooling mechanism that appears to be a promising approach to remove a large amount of heat from the engine wall. The transpiration cooling mechanism has two aspects. First, initial computations suggest that there is a reduction, as much as 75%, in the heat flux incident on the combustion chamber wall due to the transpirant modifying the combustor boundary layer. Secondly, the heat reaching the combustor wall is removed from the structure in a very effective manner by the transpirant. It is the second of these two mechanisms that is investigated experimentally in the subject paper. A transpiration cooling experiment using a radiant heating method, that provided a heat flux as high as 200 Btu/sq ft sec ( approx. 234 W/sq cm) on the surface of a specimen, was performed. The experiment utilized an arc-lamp facility (60-kW radiant power output) to provide a uniform heat flux to a test specimen. For safety reasons, helium gas was used as the transpirant in the experiments. The specimens were 1.9-cm diameter sintered, powdered-stainless-steel tubes of various porosities and a 2.54cm square tube with perforated multi-layered walls. A 15-cm portion of each specimen was heated. The cooling effectivenes and efficiencies by transpiration for each specimen were obtained using the experimental results. During the testing, various test specimens displayed a choking phenomenon in which the transpirant flow was limited as the heat flux was increased. The paper includes a preliminary analysis of the transpiration cooling mechanism and a scaling conversion study that translates the results from helium tests into the case when a hydrogen medium is used.

Choi, Sang H.↗

Nuclear light bulb propellant heating simulation using a tungsten/argon aerosol and radiation from a dc arc surrounded by a segmented mirror cavity

Experiments were conducted to simulate radiant heating of the propellant stream of a nuclear light bulb engine to obtain high bulk exit temperatures in the flowing simulated propellant stream by absorption of large fractions of the incident thermal radiation. A high-power, vortex-stabilized dc arc within an uncooled fused silica tube was used as the radiant energy source. It was surrounded by a mirror system to increase the radiation incident on the simulated propellant. The 12.7-cm-long by 2.3-cm-wide, diverging-duct test section had a transparent front wall and a reflecting rear wall. The central stream of seeded gas, a tungsten-particle/argon aerosol, had unseeded argon buffer layers on both sides to prevent coating of the duct walls. Arc operating times were approximately 0.5 sec with power levels up to 780 kW. Bulk exit temperatures were measured using a calorimeter downstream of the duct. The maximum simulated propellant bulk exit temperature obtained was 4515 K, compared with 3860 K in previous tests, 3300 to 3700 K expected in in-reactor tests in the Nuclear Furnace, and 6660 K in the reference nuclear light bulb engine. The maximum temperature in these tests was limited primarily by the amount of radiation incident on the test section (determined by the arc operating characteristics and the effectiveness of the mirror cavity).

Klein, J. F.↗

Highly silanized cellulose biocomposites for sustainable insulation materials

Microfibrillated lignocellulose networks, derived from agricultural byproducts, represent an environmentally friendly biogenic material production due to their abundant availability to circular bioeconomy and inherent carbon sink in life cycle analysis. Yet, its vulnerability to moisture and flammability, coupled with challenges in creating highly reinforced insulation materials, poses challenges for the carbon-zero green building sector. Here we address these challenges with a new concept of in-situ grafting polymerization of nanoporous silica in pre-formed lignocellulosic fiber networks. The seamlessly integrating nanoporous silica with cellulose through hydrogen bonding networks enabled us to prepare highly reinforced biogenic composites for green building insulations. A high reinforcement biocomposite with hierarchal arrangements of nanoporous silica within the cellulose network exhibits remarkable attributes. It boasts a thermal conductivity of 24.2 mW·m –1 ·K –1 , a flexural modulus of 942 MPa, and soundproofing with a 20.8 % noise reduction, as well as the fire resistance characterized by an extended time to ignition and a reduced peak heat release rate of 144 kW·m –2 at 35 kW·m –2 of incident radiant heat flux. Furthermore, it demonstrates a reduced water absorption capacity, dropping from 5.12 g·g –1 to 0.75 g·g –1 . Altogether, this study opens the new pathways towards sustainable carbon-zero building materials in the context of circular bioeconomy.

36 MATERIALS SCIENCE↗

Reusable surface insulation thermal protection systems test evaluation status

Changes in coating morphology of mullite, silica, and ceramic mullite fiber at two heating rates are described followed by a discussion of the changes in surface chemistry that occur during convective heating tests. Subsequently, the surface chemistry changes observed are compared to similar data obtained from radiantly heated coatings and the significance of the difference between the results is discussed. Finally, the changes in chemistry of the coatings in cross section before and after convectively heated cyclic testing are discussed and the significance of surface chemistry changes are described. Results indicate that the thermal conductivity of mullite surface insulation is higher than that of silica insulation, based on thermal response data. Acoustic excitation of cracked silica tiles does not lead to catastrophic failure such as spallation or tile loss. Cracks in mullite material after thermal exposure lead to fracturing of the coating and surface insulation material after acoustic excitation.

Strouhal, G.↗