Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Proton Straggling in Thick Silicon Detectors

Straggling functions for protons in thick silicon radiation detectors are computed by Monte Carlo simulation. Mean energy loss is constrained by the silicon stopping power, providing higher straggling at low energy and probabilities for stopping within the detector volume. By matching the first four moments of simulated energy-loss distributions, straggling functions are approximated by a log-normal distribution that is accurate for Vavilov k is greater than or equal to 0:3. They are verified by comparison to experimental proton data from a charged particle telescope.

Selesnick, R. S.↗

Planetary-scan system

Mariner IV scanning system and radiation detector for locating and tracking Mars

MARINER IV SPACE PROBE↗

Photon bunching and the photon-noise-limited performance of infrared detectors

The photon-noise-limited performance of a radiation detector exposed to a thermal background of temperature T is analyzed by calculating the resulting specific detectivity. Both ideal photon detectors of arbitrary quantum efficiency eta and ideal thermal detectors of arbitrary emissivity eta are considered; and the effects of both shot noise and excess noise are taken into account. The relative contributions of these two sources depend on the quantum efficiency or emissivity of the system. For frequencies nu such that hnu/kT is much less than eta, excess noise can make an appreciable contribution to the total system noise. For the case of the detection of the narrow-band radiation, the specific detectivity is independent of eta in the limit hnu/kT is much less than eta.

Boyd, R. W.↗

Plural-wavelength flame detector that discriminates between direct and reflected radiation

A flame detector employs a plurality of wavelength selective radiation detectors and a digital signal processor programmed to analyze each of the detector signals, and determine whether radiation is received directly from a small flame source that warrants generation of an alarm. The processor's algorithm employs a normalized cross-correlation analysis of the detector signals to discriminate between radiation received directly from a flame and radiation received from a reflection of a flame to insure that reflections will not trigger an alarm. In addition, the algorithm employs a Fast Fourier Transform (FFT) frequency spectrum analysis of one of the detector signals to discriminate between flames of different sizes. In a specific application, the detector incorporates two infrared (IR) detectors and one ultraviolet (UV) detector for discriminating between a directly sensed small hydrogen flame, and reflections from a large hydrogen flame. The signals generated by each of the detectors are sampled and digitized for analysis by the digital signal processor, preferably 250 times a second. A sliding time window of approximately 30 seconds of detector data is created using FIFO memories.

Hall, Gregory H.↗

Radiation monitoring container device (16-IML-1)

In this experiment, layers of radiation detectors and biological specimens, bacterial spores (Bacillus subtillis), shrimp eggs (Altemia salina), and maize seeds (Zea mays) are sandwiched together in the Radiation Monitoring Container. The detectors, sheets of plastic materials, record the nuclear track of cosmic radiation. The dosimeter package contains conventional detectors made of materials such as lithium fluoride or magnesium-silica-terbium. The thermoluminescent materials (TLD) will, when moderately heated, emit luminescent photons linearly depending upon the dose of radiation received. The experiment, enclosed in a box-like container, is mounted on the aft end cone of the Spacelab, the area where the shielding is somewhat less than other locations.

Nagaoka, S.↗

Optically induced quantum transitions in direct probed mesoscopic NbSe 2 for prototypical bolometers

Superconducting transition-edge sensors (TES) have emerged as fascinating devices to detect broadband electromagnetic radiation with low thermal noise. The advent of metallic transition metal dichalcogenides, such as NbSe 2 , has also created an impetus to understand their low-temperature properties, including superconductivity. Interestingly, NbSe 2 -based sensor within the TES framework remains unexplored. In this work, direct-probed superconducting NbSe 2 absorbers led to a proof-of-concept demonstration for the transduction of incoming light to heat, where a thermodynamic superconducting phase transition in NbSe 2 was evident to switch it to the normal-state, when biased below its superconducting transition temperature. A wavelength-dependent response of its optical absorption properties was observed, based on the incident optical excitation source used. Furthermore, extensive optical characterization studies were conducted using Raman spectroscopy, where the in-plane and out-of-plane thermal conductivity was empirically determined. Our results open new possibilities for the use of NbSe 2 in superconducting radiation detectors, including in a TES framework

47 OTHER INSTRUMENTATION↗

Radiation damage of germanium detectors

Energetic particles can produce interstitial-vacancy pairs in a crystal by knocking the atoms from their normal positions. Detectors are unique among semiconductor devices in depending on very low concentrations of electrically active impurities, and also on efficient transport of holes and electrons over relatively large distances. Because the dense regions of damage produced by energetic particles may result in donors and/or acceptors, and also provide trapping sites for holes and electrons, detectors are very sensitive to radiation damage. In addition to these effects occurring within the detector, radiation may also change the characteristics of the exposed surfaces causing unpredictable effects on the detector leakage current. Radiation-induced surface degradation has rarely, if ever, been observed for germanium detectors. The possibility of minimizing hole trapping in charge collection by the use of a high-purity germanium coaxial detector configured with the p (+) contact on the coaxial periphery is discussed.

Pehl, R. H.↗

Proton Radiation Effects on HgCdTe Avalanche Photodiode Detectors

Space radiation damage and proton induced transient effects were evaluated on 4.4 μm cutoff HgCdTe avalanche photodiode (APD) arrays developed by Leonardo DRS. Device performances as a function of total dose up to 100 krad (Si) were measured with ~60 MeV protons on 3 types of APD samples: 4x4 pixel APD fanout arrays with and without connection to a read-out integrated circuit (ROIC), and a 2x8 pixel photon counting APD focal plane array (FPA). A gamma-ray test was also conducted to study ionization effects. Both APD arrays exhibited a small decrease in the quantum efficiency and a linear increase in the dark current with the proton fluence. The 2x8 pixel photon counting FPA also exhibited an increase in the dark count rate with proton dose. After the proton irradiation and an overnight room temperature warm-up, the APD dark currents at 80 K increased significantly in both types of APD arrays. All radiation damage to these HgCdTe APD arrays annealed out after baking them at >85 °C for several hours. Transient protons through the devices were found to cause large pulses at the detector output but recover within 1 μs.

Xiaoli Sun↗

Effect of space exposure of pyroelectric infrared detectors

Pyroelectric detectors are one of many different types of infrared radiation detectors. The pyroelectric detectors are of interest for long term space use because they do not require cooling during operation. Also, they can detect at very long wavelengths and they have a relatively flat spectral response. A disadvantage is that the radiation must be chopped in order to be detected by a pyroelectric detector. The objective was to determine the effects of launch and space exposure on the performance of commercially available pyroelectric detectors. The approach was to measure certain detector parameters before and after flight and try to determine the amount and cause of the degradation. The experiment was passive: no data was taken during flight. It is concluded that lithium-tantalate and strontium-barium-niobate are suitable materials for pyroelectric detectors for long term space applications.

Robertson, James B.↗

Surface Trap Dynamics and Gamma‐Ray Detection Enhancement in Passivated FAPbBr 3 Perovskite Crystals

Perovskite‐based direct radiation detectors offer a compelling platform for room‐temperature gamma spectroscopy due to their high sensitivity, tunable optoelectronic properties, and compatibility with solution processing. While prior studies on formamidinium lead tribromide (FAPbBr 3 ) have shown that surface passivation mitigates deep trap state impact on the charge collection efficiency (CCE), the influence of surface‐based shallow traps on time‐resolved detector response remains largely unexplored. In this article, a digital signal processing (DSP) method is applied to analyze waveform rising edge dynamics in FAPbBr 3 single‐crystal detectors, identifying prompt and delayed charge collection components. Using the second derivative of the collected charge signal, the onset of shallow trap reemission is isolated, occurring 1.1 µs after carrier generation. Surface passivation suppressed deep trap states, shifting carrier occupancy toward shallower traps and extending the temporal window of delayed charge collection. This delayed contribution correlates with measurable changes in the temporal and amplitude distributions of detector events. By leveraging time‐domain filtering informed by these dynamics, a selective enhancement in signal quality and gamma peak‐to‐Compton ratio (PCR) is achieved, while preserving over 90% of photoelectric events. An improvement in the PCR to 1.80, from the original 1.09, is enabled by focusing on high collection efficiency events corresponding to reemitted carriers in the 1.1 to 3 µs range after the generation event. These results demonstrate a pathway for leveraging shallow trap dynamics to enhance spectral fidelity in time‐resolved perovskite detectors.

36 MATERIALS SCIENCE↗

Collimator of multiple plates with axially aligned identical random arrays of apertures

A collimator is disclosed for examining the spatial location of distant sources of radiation and for imaging by projection, small, near sources of radiation. The collimator consists of a plurality of plates, all of which are pierced with an identical random array of apertures. The plates are mounted perpendicular to a common axis, with like apertures on consecutive plates axially aligned so as to form radiation channels parallel to the common axis. For near sources, the collimator is interposed between the source and a radiation detector and is translated perpendicular to the common axis so as to project radiation traveling parallel to the common axis incident to the detector. For far sources the collimator is scanned by rotating it in elevation and azimuth with a detector to determine the angular distribution of the radiation from the source.

Hoover, R. B.↗

Probing the optical properties and toxicological profile of zinc tungstate nanorods

Zinc tungstate is a semiconductor known for its favorable photocatalytic, photoluminescence, and scintillation properties, coupled with its relatively low cost, reduced toxicity, and high stability in biological and catalytic environments. In particular, zinc tungstate evinces scintillation properties, namely the ability to emit visible light upon absorption of energetic radiation such as x rays, which has led to applications not only as radiation detectors but also for biomedical applications involving the delivery of optical light to deep tissue, such as photodynamic therapy and optogenetics. Here, we report on the synthesis of zinc tungstate nanorods generated via an optimized but facile method, which allows for synthetic control over the aspect ratio of the as-synthesized anisotropic motifs via rational variation of the solution pH. Additionally, we investigate the effect of aspect ratio on their resulting photoluminescent and radioluminescent properties. We further demonstrate the potential of these zinc tungstate nanorods for biomedical applications, such as photodynamic therapy for cancer treatment, by analyzing their toxicological profile within cell lines and neurons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Effect of space exposure on pyroelectric infrared detectors

Pyroelectric detectors are one of the many different types of infrared radiation detectors. Pyroelectric detectors are of interest for long-term space use because they do not require cooling during operation. Also, they can detect at very long wavelengths and they have a relatively flat spectral response. A disadvantage is that the radiation must be chopped in order to be detected by a pyroelectric detector. The objective of the experiment was to determine the effects of launch and space exposure on the performance of commercially available pyroelectric detectors. The approach was to measure performance parameters of the detectors before and after flight on the Long-Duration Exposure Facility (LDEF) and determine the loss of detector performance. The experiment was passive; no data was taken during flight.

Robertson, James B.↗