Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio↗

Preliminary Study of Iodine Gas Removal in Sodium Pools

Potential iodine gas release from failed fuel pins is a critical factor in the source term analysis of oxide fuel-loaded sodium fast reactors (SFRs). The accumulated iodine-containing gas mixtures inside pin plenums are expected to be ejected during pin failures and rise through sodium pool, with potential release of gaseous iodine to the cover gas region. Due to its potential radiological impacts, a proper assessment of iodine behavior is necessary for an accurate source term assessment. Throughout the bubble rise trajectory in the sodium pool, iodine gas is continuously removed or transformed at the bubble interface by diffusion, as the combining reaction between the iodine and sodium to form sodium iodide (NaI) is a chemically preferred process. As the final amount of iodine released from the facility is strongly influenced by the removal phenomenon inside the sodium pool, experiments were previously performed by PNC (Power Reactor and Nuclear Fuel Development Corporation) to provide insight into this phenomenon. To assess the accuracy of present methods for predicting iodine gas removal within sodium pools, several candidate approaches, available in source term analysis codes, have been summarized and evaluated in this study. Spherical cap bubbles and spherical bubbles are considered in accordance with the methods adopted in each approach, and different forms of correlations for major parameters have been implemented in accordance with the original adoptions. Based on the summarized results, important aspects to be considered have been derived.

Decontamination↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface soil impacts were calculated with the computer program Mixing-Cell Model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS).

99 GENERAL AND MISCELLANEOUS↗

The Future of X-ray Irradiation: Addressing Supply Chain Risks and Opportunities (UUR Edition)

This study supports the Office of Radiological Security’s (ORS) mission of eliminating cesium irradiators by analyzing the supply chain for self-shielded X-ray irradiators (SSXIs), identifying potential risks, and proposing mitigation measures. The research focuses on the primary components of SSXIs, including X-ray tubes, controllers, generators, and coolers or chillers, and evaluates their vulnerabilities using a comprehensive risk matrix framework. The methodology includes subject matter expert (SME) interviews with relevant manufacturers and major stakeholders, a deep literature review, and a meta-analysis of maintenance reports provided by SSXI end users. Results show that while the SSXI market is small, it’s growing, and the highly global nature of the supply chain may create vulnerabilities for critical SSXI components (X-ray tubes are the most vulnerable, followed by generators and controllers). This research communicates necessary information to address concerns of current and future end users, especially those interested in transitioning away from radioactive sources, and informs future policy aimed at supporting the irradiation industry.

07 ISOTOPE AND RADIATION SOURCES↗

Activation of Thermal Insulation and Contamination Prevention

The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of insulating materials in the Molten Chloride Reactor Experiment and to foster safer work environments through informed decision-making and strategic planning. It was written to resolve a gating comment from the core heating system preliminary design review. The largest dose expected from the considered insulation materials is about 0.1 mrem per year from Pyrogel. Although Cerablanket stood out among the insulation materials for encouraging ALARA practices, it has a higher thermal conductivity. At low power levels, focusing on reducing the generation of dust from ERD activities may be more effective for reducing the potential spread of contamination than changing the insulating material type. However, regardless of the material chosen, PPE and safety conscious procedural practices can help reduce the production and spread of activated dust––thus minimizing the radiological hazard to workers.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Domain Shift Analysis in Chest Radiographs Classification in a Veterans Healthcare Administration Population

This study aims to assess the impact of domain shift on chest X-ray classification accuracy and to analyze the influence of ground truth label quality and demographic factors such as age group, sex, and study year. We used a DenseNet121 model pre-trained MIMIC-CXR dataset for deep learning-based multi-label classification using ground truth labels from radiology reports extracted using the CheXpert and CheXbert Labeler. We compared the performance of the 14 chest X-ray labels on the MIMIC-CXR and Veterans Healthcare Administration chest X-ray dataset (VA-CXR). The validation of ground truth and the assessment of multi-label classification performance across various NLP extraction tools revealed that the VA-CXR dataset exhibited lower disagreement rates than the MIMIC-CXR datasets. Additionally, there were notable differences in AUC scores between models utilizing CheXpert and CheXbert. When evaluating multi-label classification performance across different datasets, minimal domain shift was observed in the unseen VA dataset, except for the label “Enlarged Cardiomediastinum.” The subgroup with the most significant variations in multi-label classification performance was study year. These findings underscore the importance of considering domain shift in chest X-ray classification tasks, paying particular attention to the temporality of the exam. Our study reveals the significant impact of domain shift and demographic factors on chest X-ray classification, emphasizing the need for improved transfer learning and robust model development. Addressing these challenges is crucial for advancing medical imaging research and improving patient care.

chest X-ray image classification↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.

36 MATERIALS SCIENCE↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI↗

Investigation of the iodate sorption mechanism by CoAl LDH through experiments and ab initio molecular dynamics simulations

Radioiodine released during the nuclear-fuel cycle constitutes a persistent radiological hazard. In this study, the IO 3 – uptake mechanism of CoAl LDH was resolved by combining pH-controlled sorption experiments, synchrotron XAFS, and DFT-based AIMD simulations. At pH close to 6, approximately 90% of IO 3 – was removed, and the equilibrium distribution coefficient reached about 1.7 × 10 4 mL g –1 . EXAFS analysis indicated an average iodine–oxygen bond length of 1.81 Å and a coordination number near 3, with the fit R-factor equal to 0.002. The simulations faithfully reproduced the experimental spectrum and revealed transient proton hopping events that generated metastable I–O–H species inside the interlayer, thereby confirming nitrate-to-iodate exchange as the controlling capture pathway. Atomic density profiles and radial distribution functions further showed that IO 3 – adopt an end-on orientation perpendicular to the hydroxide sheets, while water molecules mediate proton migration without disturbing the host lattice. In conclusion, the integrated experimental–computational evidence demonstrates that CoAl LDH can rapidly and selectively sequester IO 3 – under near-neutral conditions, offering atomic scale guidance for the rational engineering of layered sorbents for advanced radioactive-waste treatment.

Kang, Jaehyuk [Jeju National Univ. (Korea, Republi↗

Strategy to safely enable X-ray computed tomography examination of highly radioactive tristructural isotropic nuclear fuel

Nondestructive post-irradiation examination of nuclear fuels and materials is useful in collecting data to inform commercial licensing of new nuclear concepts. This work details the planning, shielding design, and workflow of an X-ray computed tomography examination of an irradiated AGR-5/6/7 fuel compact with a dose rate of 1318 R/hr on contact from both β and ɤ-ray radiation with 120 R/hr of the dose rate coming exclusively from ɤ-rays. Post-irradiation examination of highly radioactive samples can help reduce the timeframe from conceptualization of novel nuclear concepts to their commercial implementation as not only is less time spent waiting for experiments to decay away to acceptable levels for examinations, but data from these experiments can more quickly inform model efforts and subsequent experiments. While this work represents the hottest radiological sample that has been openly transported and examined at Idaho National Laboratory’s Irradiated Materials Characterization Laboratory to date, it is anticipated that this work and its lessons learned will facilitate future examinations of similar or even more radioactive specimens.

42 - ENGINEERING↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Simultaneous Separation of Protactinium-230 and Uranium-230 Isotopes from a Proton-Irradiated Thorium Matrix

The use of radioisotopes in cancer therapy is becoming increasingly important. As a potential candidate for targeted alpha therapy, 230 U (t 1/2 = 20.8 d), the decay daughter of 230 Pa (t 1/2 = 17.4 d) is currently being investigated for cancer treatment. For radioisotopes to be used in biomedicine, they must be radiochemically pure and free from carrier interference. This can be challenging given their short half-life. Thus, in this study, radiological separation methods for harvesting isotopes for use in biomedicine must be simple, fast, and capable of obtaining the required purity levels. Herein, we demonstrate a new rapid method for the separation of 230 U and 230 Pa from a proton-irradiated 232 Th metal target and from coproduced fission products with high recovery and purity. A dual-column approach was used, in which the first column was an anion exchange (AX) column and the second column was a DGA column. The MP-1 AX resin was used for the primary separation of the three major components (U, Pa, and Th, as well as fission products), and the DGA column was used for further purification of the separated 230 U. The method is simple and allows for straightforward separation of U, Pa, Th, and fission products; also, the entire process from target dissolution to shipment of 230 U could be completed in 3 days with an overall 230 U recovery yield of 96 ± 3%. Additionally, separated 230 Pa fractions can be used to harvest ingrown 230 U after initial separation.

DGA resin↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stabilization of Preternatural Barium Oxidation States as an Unexpected Byproduct of β-Decay: Discovery of a New Halide Semiconductor Alloy

137 Cs has a wide range of roles in the nuclear industry. The solid material, safely encapsulated in CsCl as 137 CsCl, is stored as fission product waste from nuclear power production and legacy waste from nuclear weapons production; it has also served as a radiation source in food and sewage irradiators as well as medical devices. However, because of the solubility of the chloride salt and the relatively high specific activity of 137 Cs, damaged or broken capsules can lead to severe radiological accidents. Safe capsule design and material recycling are complicated by the unclear structural evolution during β-decay, which remains ambiguous due to the differing oxidation states of Cs (1+) and Ba (2+). Here, in this study, we use first-principles calculations to investigate the evolving structure–property relationships of Cs 1–x Ba x Cl during β-decay. Despite the well-established 2+ formal oxidation state of alkali-earth metals, we find that Ba 1+ can be stabilized in the form of a mixed-valence alloy at low concentrations. Specifically, we identify three regimes for the β-decay of 137 Cs into CsCl: Ba-doped CsCl (Ba ≤ 14%), wherein Ba has the expected 2+ oxidation state; Cs–Ba–Cl alloys, where Ba has a mix of the usual Ba 2+ and highly unusual Ba 1+ oxidation state in the form of a quasi-disordered mixed-valence alloy (Ba = 25%); and phase separation into a CsCl + BaCl 2 + Ba (m) mechanical mixture, where Ba reverts to its expected 2+ oxidation state (Ba > 25%). Surprisingly, the Cs 0.75 Ba 0.25 Cl mixed-valence alloy is a narrow indirect band gap semiconductor (1.05 eV) despite the insulating nature of both CsCl and BaCl 2 . It also exhibits strongly excitonic polarized optical properties, has glass-like ultralow thermal conductivity (directional average of 0.21 W/mK at 300 K), and shows greater resistance to deformation under both tensile and volumetric strengths compared with the original CsCl structure (e.g., shear and Young’s modulus of 9.04 and 31.62 GPa, respectively). These findings imply that transmutation of 137 Cs leads to highly unusual chemical bonding that stabilizes Ba 1+ in local regions of the quasi-disordered Cs 0.25 Ba 0.75 Cl, resulting in anomalous physical properties. Moreover, this discovery provides valuable insight for safe nuclear waste capsule design, which can aid in preventing environmental or human exposure to radioactive materials.

Fuhr, Addis S. [Oak Ridge National Laboratory (ORN↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Encapsulation and Homogeneity Assessment of Sol–Gel Based Nuclear Explosive Debris Simulants

Nuclear explosive debris simulants are an important material in training and validating aspects of post-detonation nuclear forensic processes. Realistic simulants should replicate several aspects of nuclear explosive debris such as the size, shape, color, density, and chemical and radiological properties. Silica particles produced via sol-gel synthesis have recently been found to successfully reproduce many of these parameters including the controllable incorporation of radionuclide content. However, to be useful as a benchmarking material for validation and verification of laboratory methodologies, radionuclide content from batch-to-batch must be reproducible. Here, in this work, we explore the variance in radionuclide distribution incorporated into sol-gel benchmarking materials with respect to sample subdivision. Results will help inform the sample sizes required to minimize variance between samples.

36 - MATERIALS SCIENCE↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗