Search NASA⌕ Search

SEARCH · Search NASA

Results for “RAMAN SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Remote measurement of ocean temperature from depolarization in Raman scattering

Ocean temperatures may be mapped in three dimensions from an aircraft down to depths of 2 to 4 attenuation lengths by monitoring Raman radiation backscattered from a laser beam. This paper describes laboratory experiments on the temperature dependence of Raman spectra of saline solutions and calculations of the expected performance of a field system. The Raman technique is of greatest potential utility in coastal and estuarine waters where gradients are relatively high. It is estimated that seawater temperature may be measured to a statistical precision of 0.5 C at depths to four attenuation lengths in two meter water, using one Joule of transmitted laser energy.

Chang, C. H.↗

Thermal processing of omicron-terphenyl - A Raman study

Raman spectra from omicron-terphenyl sealed in glass capillary tubes were acquired over temperatures ranging from 233 to 343 K. Over this temperature range, omicron-terphenyl can exist in the solid-crystalline, molten, supercooled-liquid, and amorphous-glassy states. Representative structure-sensitive spectra are presented along with a qualitative description. The lattice spectral feature occurring at a Raman shift of 123/cm displays abrupt changes in profile and intensity as melting and glass transition occur. The intensity ratio of the C-C stretching 996/cm line and C-H stretching line at 1008/cm displays a change related to the transformation of the ordered-crystalline phase to the disordered-liquid or glassy state. At a Raman shift of 1162/cm the solid-crystalline state shows a splitting due to the effect of the crystal field. The possibility of using these structure-sensitive Raman characteristics for in situ diagnostics during materials processing is discussed.

Biswas, A.↗

Remote Pulsed-Laser Raman Spectroscopy System for Mineral Analysis

We have measured Raman spectra of carbonate, silicate, and hydrous silicate and sulfate minerals, our new remote-pulsed Raman system, indicating that it can be used to analyze the minerals on planetary surfaces to a distance of 10 to 66 meters. Additional information is contained in the original extended abstract.

Sharma, S. K.↗

High-Pressure Gaseous Burner (HPGB) Facility Completed for Quantitative Laser Diagnostics Calibration

A gas-fueled high-pressure combustion facility with optical access, which was developed over the last 2 years, has just been completed. The High Pressure Gaseous Burner (HPGB) rig at the NASA Glenn Research Center can operate at sustained pressures up to 60 atm with a variety of gaseous fuels and liquid jet fuel. The facility is unique as it is the only continuous-flow, hydrogen-capable, 60-atm rig in the world with optical access. It will provide researchers with new insights into flame conditions that simulate the environment inside the ultra-high-pressure-ratio combustion chambers of tomorrow's advanced aircraft engines. The facility provides optical access to the flame zone, enabling the calibration of nonintrusive optical diagnostics to measure chemical species and temperature. The data from the HPGB rig enables the validation of numerical codes that simulate gas turbine combustors, such as the National Combustor Code (NCC). The validation of such numerical codes is often best achieved with nonintrusive optical diagnostic techniques that meet these goals: information-rich (multispecies) and quantitative while providing good spatial and time resolution. Achieving these goals is a challenge for most nonintrusive optical diagnostic techniques. Raman scattering is a technique that meets these challenges. Raman scattering occurs when intense laser light interacts with molecules to radiate light at a shifted wavelength (known as the Raman shift). This shift in wavelength is unique to each chemical species and provides a "fingerprint" of the different species present. The facility will first be used to gather a comprehensive data base of laser Raman spectra at high pressures. These calibration data will then be used to quantify future laser Raman measurements of chemical species concentration and temperature in this facility and other facilities that use Raman scattering.

Nguyen, Quang-Viet↗

Low-Resolution Raman-Spectroscopy Combustion Thermometry

A method of optical thermometry, now undergoing development, involves low-resolution measurement of the spectrum of spontaneous Raman scattering (SRS) from N2 and O2 molecules. The method is especially suitable for measuring temperatures in high pressure combustion environments that contain N2, O2, or N2/O2 mixtures (including air). Methods based on SRS (in which scattered light is shifted in wavelength by amounts that depend on vibrational and rotational energy levels of laser-illuminated molecules) have been popular means of probing flames because they are almost the only methods that provide spatially and temporally resolved concentrations and temperatures of multiple molecular species in turbulent combustion. The present SRS-based method differs from prior SRS-based methods that have various drawbacks, a description of which would exceed the scope of this article. Two main differences between this and prior SRS-based methods are that it involves analysis in the frequency (equivalently, wavelength) domain, in contradistinction to analysis in the intensity domain in prior methods; and it involves low-resolution measurement of what amounts to predominantly the rotational Raman spectra of N2 and O2, in contradistinction to higher-resolution measurement of the vibrational Raman spectrum of N2 only in prior methods.

Nguyen, Quang-Viet↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

NASA's Turbulent Heat Flux (THX) task under the Transformational Tools & Technologies project is focused on acquiring benchmark temperature and velocity data in turbulent shear layers for validation of computational fluid dynamics (CFD) codes. Standard CFD turbulence models lack the ability to accurately calculate a number of fundamental flow phenomena, including the turbulent transport of heat. In nearly all production class Reynolds-averaged Navier-Stokes (RANS) CFD codes, a gradient-diffusion approximation is used whereby a constant turbulent Prantdl number, Prt, is used to relate an eddy viscosity calculated for the momentum terms, to the turbulent heat flux terms. The default in most CFD codes is Prt = 0.9, however this is not representative of all flows. As discussed in Yoder et al. (2015) and Reynolds (1974), Prt = 0.7 is felt to be more appropriate for jets. Recent work, as discussed in Yoder (2016a), has explored more complex formulations including variable turbulent Prantdl number models. PARTICLE IMAGE VELOCIMETRY; TEMPERATURE MEASURING INSTRUMENTS; FILM COOLING; HIGH TEMPERATURE GASES; COMPUTATIONAL FLUID DYNAMICS; PREDICTION ANALYSIS TECHNIQUES; TURBULENCE MODELS; RAMAN SPECTRA; VELOCITY; MACH NUMBER; GAS TURBINE ENGINES; NOZZLE FLOW; THERMOCOUPLES; LASER INDUCED FLUORESCENCE; COOLING FLOWS (ASTROPHYSICS); RAMAN SPECTROSCOPY; HEAT FLUX

Wernet, Mark P.↗

Nanoscale Editing of Multi and Single Layer Tungsten Disulfide via Gas‐Assisted Focused Electron Beam Induced Etching for Device Prototyping

Focused electron beam induced etching (FEBIE) with XeF 2 (xenon difluoride) precursor is conducted on multi-layer exfoliated WS 2 (tungsten disulfide) and monolayer WS 2 grown by chemical vapor deposition (CVD). The films are characterized by atomic force microscopy (AFM) and Raman and photoluminescence (PL) spectroscopy post-etching. The etch rates/efficiencies are reported as a function of electron beam energy, current, dwell time, and XeF 2 pressure. Bulk film Raman spectra are unchanged post-FEBIE, indicating minimal subsurface damage. Monolayer WS 2 shows a decrease in Raman and PL intensity post-FEBIE, with a dose-to-clear of ≈2 nC µm −2 . The study reveals regimes affected by the various mass transport contributions such as refresh time and the ratio of electrons/XeF 2 . Spontaneous etching was discovered during FEBIE of large patterned areas due to the long frame/refresh times. Density functional theory and ab initio molecular dynamics simulations compares desorption of SF x and WF x molecules from pristine WS 2 basal planes and pore edges, revealing the spontaneous etching is consistent with etching of partially etched monolayers during each frame. Single-line etching width of 21 nm, and patterning flakes into 100 nm wide channels are demonstrated. In conclusion, this work demonstrates the possibility of editing WS 2 flakes into electronic devices of arbitrary dimensions for semiconductor applications.

2D materials↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring the Caustic Dissolution of Aluminum Alloy in a Radiochemical Hot Cell Using Raman Spectroscopy

Chemical processing of highly radioactive materials commonly takes place in heavily shielded hot cells. The remote, real-time monitoring of chemical processing streams via optical spectroscopic techniques in hot cells may be particularly useful. Here in this paper, we describe the implementation of Raman spectroscopy and chemometric analysis to monitor the dissolution of aluminum-clad targets containing irradiated aluminum–neptunium oxide cermet pellets in caustic solutions in a hot cell environment. Partial least squares regression analysis was used to generate calibration models to quantify the concentration of dissolved aluminum, nitrate, and hydroxide in solutions within the radiochemical hot cell. This work explored a systematic approach to optimize a matrix of calibration standards using a D-optimal experimental design. The Design of Experiments-based regression model, in comparison to more traditional analytical approaches, was found to be the more practical method for building calibration models, with fewer samples, to obtain informative analytical data from Raman spectra.

36 MATERIALS SCIENCE↗

Infrared absorption and emission characteristics of interstellar PAHs

The mid-infrared interstellar emission spectrum with features at 3.28, 6.2, 7.7, 8.7 and 11.3 microns is discussed in terms of the Polycyclic Aromatic Hydrocarbon (PAH) hypothesis, which is based on the suggestive, but inconclusive comparison between the interstellar emission spectrum with the infrared absorption and Raman spectra of a few PAHs. The fundamental vibrations of PAHs and PAH-like species which determine the IR and Raman properties are discussed. Interstellar IR band emission is due to relaxation from highly vibrationally excited PAHs excited by ultraviolet photons. The excitation/emission process is described and the IR fluorescence from one PAH, chrysene, is traced. Generally, there is sufficient energy to populate several vibrational levels in each mode. Molecular vibrational potentials are anharmonic and emission from these higher levels will fall at lower frequencies and produce weak features to the red of the stronger fundamentals. This process is also described and can account for some spectroscopic details of the interstellar emission spectra previously unexplained. Analysis of the interstellar spectrum shows that PAHs contain between 20 and 30 carbon atoms are responsible for the emission.

Barker, J. R.↗

Infrared absorption and emission characteristics of interstellar PAHs

The mid-infrared interstellar emission spectrum with features at 3.28, 6.2, 7.7, 8.7 and 11.3 microns is discussed in terms of the Polycyclic Aromatic Hydrocarbon (PAH) hypothesis, which is based on the suggestive, but inconclusive comparison between the interstellar emission spectrum with the infrared absorption and Raman spectra of a few PAHs. The fundamental vibrations of PAHs and PAH-like species which determine the IR and Raman properties are discussed. Interstellar IR band emission is due to relaxation from highly vibrationally excited PAHs excited by ultraviolet photons. The excitation/emission process is described and the IR fluorescence from one PAH, chrysene, is traced. Generally, there is sufficient energy to populate several vibrational levels in each mode. Molecular vibrational potentials are anharmonic and emission from these higher levels will fall at lower frequencies and produce weak features to the red of the stronger fundamentals. This process is also described and can account for some spectroscopic details of the interstellar emission spectra previously unexplained. Analysis of the interstellar spectrum shows that PAHs contain between 20 and 30 carbon atoms and are responsible for the emission.

Allamandola, L. J.↗

Amplitude-mode spectroscopy of chemically injected and photogenerated charge carriers in semiconducting single-walled carbon nanotubes

In one-dimensional semiconductors such as conjugated polymers and semiconducting single-walled carbon nanotubes (s-SWCNTs), injected charge carriers (electrons or holes) can have profound impacts on both electronic conductivity and optical spectra, even at low carrier densities. Understanding charge-related spectral features is a key fundamental challenge with important technological implications. Here, we employ a systematic suite of experimental and theoretical tools to understand the mid-infrared charge signatures of heavily p-type doped polymer-wrapped s-SWCNTs. Across a broad range of nanotube diameters, we find that hole charge carriers induce strong Fano anti-resonances in mid-infrared transmission spectra that correspond to defect-related (D-band) and in-plane tangential (G-band) Raman-active vibrational modes, along with anti-resonances arising from infrared (IR)-active polymer and SWCNT modes. We employ 13C isotope-labeled s-SWCNTs and a removable wrapping polymer to clarify the relative intensities, energies, and sources of all observed anti-resonances. Simulations performed with the "amplitude mode model" are used to quantitatively reproduce Raman spectra and also help to explain the outsized intensity of the D-band anti-resonance, relative to the G-band, observed for both moderately and degenerately doped s-SWCNTs. Here, the results provide a framework for future studies of ground- and excited-state charge carriers in s-SWCNTs and a variety of low-dimensional materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of graphene oxide-like materials prepared from different deashed-devolatilized coal chars and comparison with graphite-based graphene oxide, with or without the ultrasonication treatment

Deashed-devolatilized coal chars were prepared from anthracite, bituminous, subbituminous, and lignite coals, then oxidized to prepare graphene oxide (GO)-like materials that were extensively characterized and compared with a pristine graphite-based GO sample (CGO). Coal-based GO-like materials and CGO were then subjected to ultrasonication treatment for delamination, which also impacted their physicochemical properties. The surface oxygen contents of CGO and coal-based samples were ~32 % and ~26–35 %, respectively, that were reduced to ~27 % and ~21–24 %, respectively, after ultrasonication. The Fourier transform infrared and X-ray photoelectron spectroscopy spectra of all samples showed different profiles before and after the ultrasonication, suggesting a change in chemical functionalities. The Raman spectra of CGO and coal-based samples exhibited similar D and G bands with D/G intensity ratios (I D /I G ) of 0.93 and 0.88–0.92, respectively. The I D /I G ratio of CGO and most of the coal-based samples increased after the ultrasonication due to creation of more defects. The main X-ray diffraction (XRD) peak for CGO and coal-based samples were observed at ~11° and ~22–24°, respectively. Ultrasonication of the samples resulted in a reduction of crystallite size and number of layers for all CGO and coal-based samples, confirming both splitting and delamination of carbon layers. Additionally, different coal-based samples exhibited almost overlapping XRD profiles after the ultrasonication.

36 MATERIALS SCIENCE↗

Raman spectroscopy of gases with a Fourier transform spectrometer - The spectrum of D2

Fourier transform spectrometry (FTS) is presently used to record the spontaneous incoherent laser Raman spectra of gases. The high resolution, sensitivity, calibration accuracy and spectral coverage achieved demonstrate the viability of FTS for Raman spectroscopy. Attention is given to the coefficients obtained by fitting measurements obtained from the spectrum of D2, containing both v = 0-0 and 1-0 transitions, to the Dunham (1932) expansion of the vibration-rotation energy levels.

Jennings, D. E.↗

Computationally Guided Investigation of the Optical Spectra of Pure β-UO 3

Single-phase β-UO 3 is synthesized by flash heating UO 2 (NO 3 )·6H 2 O in air to 450 °C and annealing for 60 h under the same conditions. For the first time, we report the Raman spectra of pure β-UO 3 . To facilitate the assignment of Raman and infrared vibrational modes, we use density functional theory with density functional perturbation theory. By employing a novel analysis scheme that includes the mode frequencies as well as a quantitative analysis of the mode eigenvectors, we assign the observed spectral features to individual chemical modes. In particular, the density functional theory optimized structure, observed Raman spectrum, and eigenvector analysis suggest the presence of four crystallographically distinct uranyl ions, one more than has previously been suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Confocal Raman Microscopy as an In Situ Probe of Volume Change in Hydration-Sensitive Polymer Membranes

An approach is described for measuring hydration-induced volume change within ion conductive polymer membranes and thin films by adapting the technique of confocal Raman microscopy. With careful consideration of factors that affect excitation and scattering within the confocal probe volume region, material swelling and deswelling were estimated from the intensities of polymer matrix spectral features. A high numerical aperture oil-immersion objective was used to achieve tight focusing within samples and the efficient collection of Raman scattered light. The approach is demonstrated for a fluorinated cation-exchange ionomer (Nafion) and the hydrocarbon anion-exchange ionomer Sustainion. Samples were monitored while under a nitrogen atmosphere that was cycled between dry and humid (∼50% relative humidity, RH) states. The volume changes estimated from the Raman spectra were in close agreement with those derived from conventional measurements. The reported work advances understanding needed to adapt confocal Raman microscopy for quantitative in situ and operando studies of ionomers within electrochemical devices, such as polymer electrolyte membrane fuel cells and electrolyzers, and lays a foundation for broader applications in the study of hydration-induced polymer swelling and the associated molecular level water and polymer framework structural changes.

Absorption↗

Raman Spectral Observation of a "New Phase" Observed in Nickel Electrodes Cycled to Failure

A "new phase" is reported in nickel electrodes from Ni/H boilerplate cells which were cycled to failure in electrolyte of variable kOH concentration. Raman spectra clearly show the presence of this phase, and these spectra have been used to quantify the amounts present in these electrodes (in the volume sampled by the laser beam) Raman spectroscopy has been found to be capable of differentiating the various phases which can be present in nickel .This differentiation is possible because of the structural variation observed for these phases. Ten of twelve electrodes examined contain at least some of this new phase. The presence of this "new phase" correlates with cell failure, and it is proposed that the presence of this phase may play a role in early electrode failure.

Loyselle, P. L.↗