Search NASA⌕ Search

SEARCH · Search NASA

Results for “REACTOR ACCIDENT SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

FUEL PERFORMANCE SIMULATION OF HIGH BURNUP FUELS IN PLANNED INTEGRAL DESIGN BASIS ACCIDENT EXPERIMENTS

High burnup (HBu) fuel rods from the Byron Nuclear Generating Station (BNGS) were recently received at Idaho National Laboratory (INL) to support a variety of planned Nuclear Energy fuel cycle R&D objectives ranging from fuel performance, fuel recycle, and spent fuel research topics. Among these R&D activities, these fuel rods will be the subjects of multiple in-pile experiment programs at the Transient Reactor Test (TREAT) facility as well as detailed characterization and testing in the hot cells at INL and Oak Ridge National Laboratory (ORNL). TREAT RIA experiments are planned for the Nuclear Energy Agency Framework for Irradiation Experiments (FIDES) Joint Experimental Program called High burnup Experiments in Reactivity Initiated Accident (HERA) program. TREAT and ORNL-furnace LOCA experiments are part of the Department of Energy (DOE) Advanced Fuels Campaign (AFC) program U.S. consensus LOCA test plan, and the in-pile experiments have also been proposed in a FIDES project called Loss of Coolant-High Burnup (LOC-HBu). The results of these test programs will provide crucial data about safety performance enabling extended licensable burnup limits for these fuels. The purpose of this paper is to document fuel performance computational simulations of the BNGS fuel using the Bison code. The detailed assessments include (1) the irradiation history of the fuel to provide prediction of as-run fuel conditions and (2) extending the irradiated fuel conditions into the as-designed experiment conditions for the HERA-HBu RIA experiments and for the LOC-HBu LOCA experiments. The results of these assessments will inform post-irradiation examinations (PIE) of the BNGS parent rods and detailed final design of the planned experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SCALE Shielding Calculations for Advanced Reactor Accident Scenarios

The study results presented in this paper demonstrate the capabilities of the SCALE computer code for non–light water reactor (non-LWR) radiation source term and shielding calculations in support of the U.S. Nuclear Regulatory Commission non-LWR fuel cycle demonstration project. Representative non-LWR types, including the sodium-cooled fast reactor (SFR), the molten salt reactor (MSR), and the heat pipe microreactor (HPMR), were analyzed to evaluate dose rates associated with postulated accident scenarios (SFR and MSR), reactor operation (MSR and HPMR), and fuel self-protecting characteristics (HPMR). New features were implemented in SCALE depletion codes to better simulate MSR operation.

MSR↗

SAS4A/SASSYS-1 Lead Verification Test Suite

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over forty-five years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. Although SAS4A/SASSYS-1 was developed to support the analysis of any liquid-metal-cooled nuclear reactor, it has primarily been utilized to design and analyze Sodium Fast Reactors (SFRs). As a result, most of the verification basis for SAS4A/SASSYS-1 utilizes sodium as a coolant and geometry descriptions that are typical of a SFR facility. In this work, new verification problems are defined to extend the applicability of the SAS4A/SASSYS-1 verification basis into Lead Fast Reactor (LFR) design space. A review of the existing SAS4A/SASSYS-1 SFR verification test suite is performed to determine the number of test cases that are SFR specific. SFR specific test cases are replicated using lead as a coolant and system layouts that are representative of LFRs. This report provides definitions and reference solutions for seven new test cases that scope lead-specific features and capabilities of the software. For a verification test to be considered acceptable, comparisons of analytical solutions to SAS4A/SASSYS-1 predictions must produce negligible or justifiable errors. All LFR specific test cases are found to be acceptable.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safety Testing of AGR-5/6/7 Compacts 2-2-2 and 2-2-4

Compacts 2-2-2 and 2-2-4 from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s final irradiation campaign (AGR-5/6/7) were each separately subjected to a thermal soak at 1600°C for 300 h under flowing helium to simulated conditions experienced during a postulated high-temperature gas-cooled reactor (HTGR) depressurization conduction cooldown event. The safety testing of the fuel compacts’ performance under accident conditions was conducted in the Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF), which utilizes a stand-alone hot cell at the Irradiated Fuels Examination Laboratory (IFEL). The CCCTF heats fuel to temperatures up to 1900°C in a non-oxidizing environment while continuously monitoring the sweep gas for radioactive 85 Kr to detect release levels associated with hermetic failure of the tristructural-isotropic (TRISO) coating surrounding each fuel kernel. In addition, certain metallic radionuclides that escape the fuel compact are collected on deposition cups that are periodically exchanged with a new cup to obtain information on the overall retention behavior of the TRISO coating layers. Because cesium can diffuse through intact pyrocarbon layers, abnormal degradation of the silicon carbide (SiC) layer in the absence of holistic TRISO coating failure is indicated by release of 134 Cs at levels equivalent to an individual particle inventory in the absence of significant 85 Kr release (Hunn et al. 2014). Additional description of the CCCTF system is provided in Appendix A.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SAS4A/SASSYS-1 Version 5.7 and 5.6 Release Notes

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. In this report, the major developments that were implemented in Versions 5.7 and 5.6 are summarized and an overview of all changes made between versions is presented. SAS Version 5.7 and 5.6 introduced a number of modeling improvements that allow users to capture important phenomena, such as pump heating and metallic fuel performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of SAS4A/SASSYS-1 Software Development and Application (FY2024)

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years. It has been identified as a critical element of safety analysis capabilities for the U.S. Department of Energy and is utilized within industry to perform the transient safety analyses required to support the licensing of Liquid Metal-cooled Fast Reactors (LMFRs). This report summarizes the code development and update activities carried out during FY2024. In FY2024, programmatic activities focused on key improvements to software useability, such as enhanced user interfaces for reactivity feedback modeling, improvements in stability/useability of the Code Manual, and improvements to the acceptance testing infrastructure, including automation of acceptance testing and generation of the Acceptance Testing Report. To support end user applications, an open training was held, a semi-public forum was maintained, and a practical benchmarking and validation matrix was developed which allowed limitations of existing testing capabilities to be assessed. The existing fuel models were also enhanced with improved modeling capabilities and testing for the oxide and annular fuel models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MSR Safety Adequacy Demonstration US Contributions Towards a Common Goal

Molten Salt Reactors (MSRs) are currently under development worldwide. The US government has been sponsoring development of MSR safety adequacy evaluation information and tools. The US is a member of the Generation IV International Forum (GIF) MSR provisional System Steering Committee (pSSC). MSR pSSC collaboration is limited to exchange of open-fundamental information. Information employed to assess reactor safety adequacy needs to remain open to external scrutiny. US entities continue to measure fuel salt thermophysical and thermochemical properties, which have now been released into an open database. Non-US entities also continue to measure and openly publish fuel salt thermophysical and thermochemical properties. US entities continue to perform MSR accident progression experiments and simulations, the results of which are being reported in the open, scientific literature. The demonstrations have not yet been at sufficient scale to necessitate international collaboration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MELCOR Model Development of the General Atomics Fast Modular Reactor

General Atomics Electromagnetic Systems (GA-EMS) is currently developing a fast modular reactor (FMR) capable of providing safe, carbon-free electricity by 2035. As part of the development process, researchers at the University of Wisconsin-Madison (UWM) use MELCOR 2.2 to develop a simulation model of the proposed design to perform accident analyses. This paper summarizes the efforts of researchers at UWM in the creation of the FMR model. This model was built based on initial FMR design parameters. The design parameters will change as the design evolves and is refined.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation and Analysis on Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS) under SBLOCA scenario by using Cardinal to support the fracture mechanics analyses

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended durations or under accident condition. As one of the most significant components of a Reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Ageing degradation mechanisms (e.g. thermos-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary. The multi-physics simulations are performed using Cardinal, a wrapping of the GPU-oriented spectral element Computational Fluid Dynamics (CFD) code NekRS and other multi-physics sub-modules within the MOOSE framework. Cardinal now fully supports MOOSE stochastic perturbations of NekRS models with varying boundary conditions, initial conditions, material properties, and any other quantity which is defined by a kernel (such as coefficients in a momentum source model). The implementation is designed in a flexible manner so that scalar values are sent from MOOSE into a user scratch space in NekRS, which can then be applied for any purpose within the NekRS case files (both on the host and device). When modeling PTS, several factors can impact the results significantly. In this report, the impacts of the geometry of the model, Reynolds number and buoyancy effect are investigated. Two geometry, i.e., a simplified model and a realistic RPV model, with both laminar and turbulent flow condition are adopted for the PTS simulation with and without buoyancy effect. The purpose of the investigation is to understand the impact of these factors on the prediction of temperature history of RPV. The accurate prediction on the temperature evolution, which will be exported to Grizzly code for further analyses on the progression of aging mechanisms and their effects on the integrity of RPV structures, is very crucial. Based on the understanding of these factors, a more sophisticated model is built to analysis the PTS under SBLOCA scenario. A literature survey is conducted to pick the SBLOCA scenario for the multi-physics simulation. The analysis helps to explain the form and the transformation of the cold plum when the ECC is activated under SBLOCA. This model can be can be applied to study the PTS effect for different RPV configurations. The results can help to assess structural component degradation for advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Microreactor Safety Analysis Challenges and Recommendations for Utilization of the Comprehensive Reactor Analysis Bundle

To enable the broad deployment of microreactors in fundamentally new application regimes (i.e., mobile and autonomous operations), their safety must be indisputable in terms of possessing inherent resistance to severe offsite dose consequences. Therefore, mechanistic beyond-design-basis event source term calculations that demonstrate a sufficiently large margin of safety will be required to accommodate these new application regimes, which have no history of commercial regulation. Even for traditional reactor operation configurations, safety analysis expertise and familiarity with accident phenomena and conditions in microreactors—specifically those with heat pipe primary cooling arrangements—are lacking compared with other advanced reactor concepts and small modular reactors. Recently, modeling and simulation tools to account for unique heat pipe design aspects have been developed by Sandia National Laboratories with MELCOR and by the US Department of Energy’s (DOE’s) Office of Nuclear Energy Advanced Modeling and Simulation Program with BlueCRAB. However, further demonstration and assessment of potential knowledge gaps are needed to support these codes’ broad usage by the microreactor community. Through the DOE Microreactor Program, an initial assessment of these two tools and guidance on how an evaluation model could be constructed was performed and is reported herein. Moreover, a proposed approach for demonstrating an evaluation model using these two tools is outlined.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Single-Phase, Transient, Subchannel Code, within the MOOSE Multi-Physics Computational Framework

Subchannel codes have been widely used for thermal-hydraulics analyses in nuclear reactors. This paper details the development of a novel subchannel code within the Idaho National Laboratory’s (INL) Multi-physics Object Oriented Simulation Environment (MOOSE). MOOSE is a parallel computational framework targeted at the solution of systems of coupled, nonlinear partial differential equations, that often arise in the simulation of nuclear processes. As such, it includes codes/modules able to solve the multiple linear and nonlinear physics that describe a nuclear reactor, under normal operation conditions or accidents. This includes thermal-hydraulics, fuel performance, and neutronics codes, between others. A MOOSE-based subchannel code is a new addition to the fleet of INL-developed codes, based on the MOOSE framework. In this work, we present the derivation of the subchannel equations for a single-phase fluid, we proceed with the description of the algorithm that is used to solve these equations and describe how this algorithm was implemented within MOOSE. We also present how this code can be coupled to the BISON fuel performance code. Next, we verify the friction model and the turbulent mixing model. We calibrate the turbulent modeling parameters for momentum mixing and enthalpy mixing, C T , β. We validate the code using experimental results and last demonstrate the coupling capabilities using a simple example.

42 ENGINEERING↗

Post-irradiation 1600°C Heating Test of AGR-1 UCO Fuel Kernels

Five bare kernels were selected from the U.S. Advanced Gas Reactor (AGR) 1 irradiation experiment Compact 5-3-1 to perform post-irradiation safety tests. The safety test involved heating the kernels in the Fuel Accident Condition Simulator (FACS) furnace in the inert atmosphere to a peak temperature of 1600°C and isothermally holding at this temperature for about 47 hours while collecting fission products released. This test was to assess the retention of fission products in bare kernels without the effects of the other TRISO layers (buffer, IPyC, SiC, and OPyC) or the graphitic matrix material. The bare kernels released nearly 100% of cesium and antimony, while they were able to maintain about 30% of europium, 50% of strontium, and the majority of cerium and ruthenium. In addition, about 48% of the calculated inventory of Kr-85 released during the test, indicating that kernels were capable of retaining a considerable fraction of fission gas K-85 during irradiation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic Modeling of a Fast Spectrum Molten Salt Reactor Integrated Energy System

Liquid-fueled molten salt fast reactors and nuclear-powered integrated energy systems (IESs) have the potential to play a pivotal role in the green energy transition. However, these systems have little to no operating experience. There is therefore increased interest and value in modeling and simulating these systems. The IES dynamic model developed in this work utilizes a lumped-parameter control volume methodology to investigate the behavior of the IES in a variety of accident scenarios. The results provide initial evidence for the potential inherent safety of the advanced reactor because of temperature-dependent reactivity feedback and the efficiency of hydrogen and electricity production at the high temperatures provided by the advanced reactor.

MCFR↗

Multiphysics Analyses of the Protected and Unprotected Loss of Forced Cooling Accidents in the HTR-PM

Here, we present the multiphysics simulation results for the protected pressurized and depressurized loss of forced cooling (PLOFC and DLOFC) events in the High-Temperature gas-cooled Reactor--Pebble-bed Module (HTR-PM) equilibrium core using the Griffin-Pronghorn coupled code system. Additionally, this paper discusses the strategy for estimating the spontaneous fission neutron source needed for unprotected events and re-criticality calculations. The solutions of the protected PLOFC and DLOFC events were verified against similar solutions obtained for temperature evolutions from the open literature. Both the average and maximum pebble surface temperatures behaved as expected during the DLOFC and remained below 1800 K. The PLOFC results are highly dependent on the ability to resolve the natural circulation in the core, which is impacted by the mesh resolution in Pronghorn. Furthermore, we present the results of the unprotected DLOFC transient to predict the timing of the re-criticality event, which occurred 47 hours after the onset of the transient, and the new steady-state power of 1.3 MW.

42 - ENGINEERING↗