Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECEIPTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-T-251: Developing a Daily Proton Beam Monitoring System

Purpose: To develop a daily monitoring system for proton beam output check and beam uniformity check. Methods: Designed for continuously irradiated photon and electron beams with a field size of 20 cm x 20 cm, the daily output checker (Sun Nuclear, Inc.) is not suitable for monitoring proton beams with inter-pulse beam-off and a field size smaller than 14–16 cm in diameter. To allow such proton beam monitoring, the following tests were performed. 1. Absolute dose and array calibrations which accept continuous irradiation only, were performed using photon beams. 2. Five ion chambers within the central area of 8 cm x 8 cm were utilized to check constancy of output at the center of beam modulation and at distal edge and to check beam symmetry and flatness. 3. To simplify our evaluation, the array calibration was manually modified, such that all five chambers report equal values in spite of their differences in build-up thicknesses. 4. The chamber at the lower-right corner is placed under a buildup thickness that can offer dose measurement at the distal edge. This buildup thickness was determined by proton beam range measurements, which established buildup thickness for beam output measurement at the central chamber and range measurement at the corner chamber. 5. The beam-off delay which allows receipt of pulsed irradiation was activated and optimal delay times were determined for each proton beam at 149.6, 185.6, and 249.5 MeV. Results: The above system was tested by miss-steering proton beams and altering phantom thickness by 1 mm at a time. The system reliably monitored the beam with: 3% tolerance for beam flatness, symmetry and output. The range difference of 0.5 mm could be detected at all energies by setting a tolerance of 20%. Conclusion: A quick daily proton beam monitoring system was feasible.

07 ISOTOPE AND RADIATION SOURCES↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗

Characterization of the antispike IgG immune response to COVID-19 vaccines in people with a wide variety of immunodeficiencies

Research on coronavirus disease 2019 vaccination in immune-deficient/disordered people (IDP) has focused on cancer and organ transplantation populations. In a prospective cohort of 195 IDP and 35 healthy volunteers (HV), antispike immunoglobulin G (IgG) was detected in 88% of IDP after dose 2, increasing to 93% by 6 months after dose 3. Despite high seroconversion, median IgG levels for IDP never surpassed one-third that of HV. IgG binding to Omicron BA.1 was lowest among variants. Angiotensin-converting enzyme 2 pseudo-neutralization only modestly correlated with antispike IgG concentration. IgG levels were not significantly altered by receipt of different messenger RNA–based vaccines, immunomodulating treatments, and prior severe acute respiratory syndrome coronavirus 2 infections. While our data show that three doses of coronavirus disease 2019 vaccinations induce antispike IgG in most IDP, additional doses are needed to increase protection. Because of the notably reduced IgG response to Omicron BA.1, the efficacy of additional vaccinations, including bivalent vaccines, should be studied in this population.

60 APPLIED LIFE SCIENCES↗

Relativistic nuclear corrections to the spin structure function of the deuteron in the light-cone variables

The relativistic deuteron has been considered in the light-cone formalism as a system of two strongly interacting nucleons (two-nucleon approximation). The technique for the calculation of the average helicity of the proton in the deuteron has been considered in the light-cone variables. A receipt has been pro-posed for the consistent calculation of relativistic nuclear corrections to the average helicity of the proton in the deuteron and to the spin structure function of the deuteron g{sub 1}{sup D}. Relativistic-correction-induced change in the Bjorken sum rule has been discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physical processes involved in strip electrode welding using the method of slatted splicing

Physical processes that take place in a strip electrode during welding using the slatted splicing technique are considered. Flowing of the welding current in the electrode is shown to be the key process which determines electrode heating and melting. Technological receipts are proposed that allow obtaining high-quality welds by the method of slatted splicing.

36 MATERIALS SCIENCE↗

Robust Event Simulation Variants Endowed to Ns-3 for General Exploration

Sandia's ns-3 contributions are modifications to the open source ns-3 network simulator that enable simulation speedup. One improvement, for example, removes the need for simulating the transmission and receipt of packets between nodes that are too distant to actually be able to communicate. In large-scale simulations this optimization has shown significant gains in performance. Additional contributions will pave the way for parallel discrete simulation (PDES) in ns-3. SAND2020-12456 O Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Dickson, Joseph↗

COVID-19 Outcomes by Cancer Status, Site, Treatment, and Vaccination

Background: Studies have shown an increased risk of severe SARS-CoV-2–related (COVID-19) disease outcome and mortality for patients with cancer, but it is not well understood whether associations vary by cancer site, cancer treatment, and vaccination status. Methods: Using electronic health record data from an academic medical center, we identified a retrospective cohort of 260,757 individuals tested for or diagnosed with COVID-19 from March 10, 2020, to August 1, 2022. Of these, 52,019 tested positive for COVID-19 of whom 13,752 had a cancer diagnosis. We conducted Firth-corrected logistic regression to assess the association between cancer status, site, treatment, vaccination, and four COVID-19 outcomes: hospitalization, intensive care unit admission, mortality, and a composite “severe COVID” outcome. Results: Cancer diagnosis was significantly associated with higher rates of severe COVID, hospitalization, and mortality. These associations were driven by patients whose most recent initial cancer diagnosis was within the past 3 years. Chemotherapy receipt, colorectal cancer, hematologic malignancies, kidney cancer, and lung cancer were significantly associated with higher rates of worse COVID-19 outcomes. Vaccinations were significantly associated with lower rates of worse COVID-19 outcomes regardless of cancer status. Conclusions: Patients with colorectal cancer, hematologic malignancies, kidney cancer, or lung cancer or who receive chemotherapy for treatment should be cautious because of their increased risk of worse COVID-19 outcomes, even after vaccination. Impact: Additional COVID-19 precautions are warranted for people with certain cancer types and treatments. Further, significant benefit from vaccination is noted for both cancer and cancer-free patients.

60 APPLIED LIFE SCIENCES↗

Radiation Therapy After Breast-Conserving Surgery in Women 70 Years of Age and Older: How Wisely Do We Choose?

Background: Despite data from randomized trials supporting omission of radiation therapy (RT) for women ≥ 70 years of age with T1, estrogen receptor-positive (ER+) tumors undergoing breast-conserving therapy (BCT), RT usage remains high. We reviewed our institutional experience to determine if risk factors for local recurrence or comorbidities influenced use. Methods: Women ≥ 70 years of age with T1, ER+, human epidermal growth factor receptor 2-negative (HER2−) tumors undergoing BCT in 2010–2012 were identified from a prospectively maintained database. Ten-year estimated mortality was calculated using the Suemoto index. The associations of clinicopathological features and mortality risk on receipt of RT were examined. Results: Overall, 323 patients with 327 cancers were identified. Median age was 75 years, median tumor size was 1 cm, and all were clinically node negative; 53.7% of patients received RT. RT usage decreased with age (73.6%, age 70–74 years; 49.5%, age 75–79 years; 33.3%, age 80–84 years; 10.7%, ≥ 85 years; p < 0.001). Within age groups, estimated mortality did not impact RT usage. On multivariable analysis, only younger age and larger tumor size were associated with RT use. Recurrence-free survival was 98% versus 93% with and without RT, respectively (p = 0.011). Those who received adjuvant radiation also had improved overall survival (92% vs. 89%), although this effect did not reach statistical significance (p = 0.051). Conclusion: Neither the factors associated with risk of local recurrence nor the estimated risk of death in 10 years were associated with use of adjuvant radiation in a large cohort of women ≥ 70 years of age with small ER+ breast cancers treated with breast-conserving surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surgical Management of the Axilla in Clinically Node-Positive Patients Receiving Neoadjuvant Chemotherapy: A National Cancer Database Analysis

Background: The feasibility of sentinel lymph node biopsy (SLNB) in patients with clinically node-positive (cN+) disease who convert to clinically node-negative (cN0) disease following neoadjuvant chemotherapy (NAC) has been evaluated in several large clinical trials, but it remains unclear whether the approach has been broadly adopted in the United States. Methods: The National Cancer Database was used to identify women diagnosed with cN+ breast cancer who received NAC followed by surgery between 2012 and 2015. Trends in axillary surgery were evaluated and multivariable logistic regression analyses performed to determine factors associated with receipt of SLNB. Results: Of 12,965 women cN+ at baseline, the use of SLNB increased from 31.8% in 2012 to 49% in 2015 (p < 0.001). Using axillary pCR as a surrogate for patients who convert to cN0 following NAC, among 5127 (39.5%) ypN0 patients, SLNB increased from 38.2 to 58.4% over the study period (p < 0.001), resulting in avoidance of axillary dissection in 42.2% of ypN0 patients by 2015. In adjusted analyses, factors significantly associated with SLNB attempt included cN1 disease, age < 45 years, treatment facility type, triple-negative and HER2-positive subtypes, and year of diagnosis. In women with residual isolated tumor cells (ITCs), micrometastases, and ypN1 disease, SLNB was the only axillary procedure performed in 36.9%, 23.6%, and 13.0% of cases. Conclusions: The use of SLNB in cN+ patients receiving NAC increased significantly between 2012 and 2015. SLNB alone was performed in more than 10% of patients with ypN1 disease, 20% with micrometastases, and 35% with ITCs; the oncologic safety of omitting axillary dissection in these patients requires further evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LQCD NN S-wave @ SU(3) on C103

This data contains lattice QCD data files for one- and two-nucleon correlation functions on the C103 ensemble. It also contains lattice QCD data sets needed to compute the HAL QCD potential on the same configurations. 'LQCD NN S-wave @ SU(3) on C103' Copyright (c) 2025, The Regents of the University of California, through Lawrence Berkeley National Laboratory (subject to receipt of any required approvals from the U.S. Dept. of Energy). All rights reserved. This work is openly licensed via CC BY 4.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GLYCOLIC - FORMIC ACID FLOWSHEET DEVELOPMENT

Flowsheet testing was performed to further develop the nitric/glycolic/formic acid flowsheet as an alternative to the nitric/formic flowsheet currently being processed at the DWPF. This new flowsheet has shown that mercury can be removed in the Sludge Receipt and Adjustment Tank (SRAT) with minimal hydrogen generation. All other processing objectives were also met, including greatly reducing the Slurry Mix Evaporator (SME) product yield stress as compared to the baseline nitric/formic flowsheet. Eight runs were performed in total, including the baseline run. The baseline nitric/formic flowsheet run was extremely difficult to process under existing DWPF acceptance criteria with this simulant at the HM levels of noble metals. While nitrite was destroyed and mercury was removed to near the DWPF limit, the rheology of the SRAT and SME products were well above design basis and hydrogen generation far exceeded the DWPF limit. In addition, mixing during the SME cycle was very poor. In this sense, the nitric/glycolic/formic acid flowsheet represents a significant upgrade over the current flowsheet. In the nitric/glycolic/formic flowsheet runs, mercury was successfully removed with almost no hydrogen generation and the SRAT and SME products yield stresses were within process limits or previously processed ranges. It is recommended that DWPF continue to support development of the nitric/glycolic/formic flowsheet. Although experience is limited at this time, this flowsheet meets or outperforms the current flowsheet in many regards, including off-gas generation, mercury removal, product rheology and general ease of processing. Additional flowsheet testing will allow for a more thorough understanding of the chemistry and effectiveness of the flowsheet over a range of sludge compositions and formic/glycolic ratios. This testing will also show whether the REDOX and metal solubility concerns with this change in the flowsheet can be addressed by just adjusting the volumes of glycolic acid added. The outstanding issues regarding the glycolic/formic flowsheet include increasing understanding of the impact on glass REDOX control and increased metal solubility, particularly iron, during processing. Additionally, evaluations of the utility of the flowsheet over varying sludge compositions should be completed to ensure flowsheet robustness. Work has already been initiated to further understand the REDOX and iron solubility areas.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE IMPACT OF THE MCU LIFE EXTENSION SOLVENT ON DWPF GLASS FORMULATION EFFORTS

As a part of the Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) Life Extension Project, a next generation solvent (NG-CSSX), a new strip acid, and modified monosodium titanate (mMST) will be deployed. The strip acid will be changed from dilute nitric acid to dilute boric acid (0.01 M). Because of these changes, experimental testing with the next generation solvent and mMST is required to determine the impact of these changes in 512-S operations as well as Chemical Process Cell (CPC), Defense Waste Processing Facility (DWPF) glass formulation activities, and melter operations at DWPF. To support programmatic objectives, the downstream impacts of the boric acid strip effluent (SE) to the glass formulation activities and melter operations are considered in this study. More specifically, the impacts of boric acid additions to the projected SB7b operating windows, potential impacts to frit production temperatures, and the potential impact of boron volatility are evaluated. Although various boric acid molarities have been reported and discussed, the baseline flowsheet used to support this assessment was 0.01M boric acid. The results of the paper study assessment indicate that Frit 418 and Frit 418-7D are robust to the implementation of the 0.01M boric acid SE into the SB7b flowsheet (sludge-only or ARP-added). More specifically, the projected operating windows for the nominal SB7b projections remain essentially constant (i.e., 25-43 or 25-44% waste loading (WL)) regardless of the flowsheet options (sludge-only, ARP added, and/or the presence of the new SE). These results indicate that even if SE is not transferred to the Sludge Receipt and Adjustment Tank (SRAT), there would be no need to add boric acid (from a trim tank) to compositionally compensate for the absence of the boric acid SE in either a sludge-only or ARP-added SB7b flowsheet. With respect to boron volatility, the Measurement Acceptability Region (MAR) assessments also suggest that Slurry Mix Evaporator (SME) acceptability decisions would not be different assuming either 100% of the B{sub 2}O{sub 3} from the SE were retained or volatilized. More specifically, the 0.84 wt% B{sub 2}O{sub 3} in the SE is so minor that its presence in the SME analysis does not influence SME acceptability decisions. In fact, using the 100% retention and 100% volatilization composition projections, only minor differences in the predicted properties of the glass product occur with all of the glasses being acceptable over a WL interval of 32-42%. Based on the 0.01M boric acid flowsheet, there is very little difference between Frit 418 and Frit 418-7D (a frit that was compositionally altered to account for the 0.84 wt% B{sub 2}O{sub 3} in the SE) with respect to melt temperature. In fact, when one evaluates the composition of Frit 418-7D, it lies within the current Frit 418 vendor specifications and therefore could have been produced by the vendor targeting the nominal composition of Frit 418.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2010 Annual Summary Report for the Area 3 and Area 5 Radioactive Management Sites at the Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office performed an annual review of the Area 3 and Area 5 Radioactive Waste Management Site (RWMS) Performance Assessments (PAs) and Composite Analyses (CAs) in fiscal year (FY) 2010. This annual summary report presents data and conclusions from the FY 2010 review, and determines the adequacy of the PAs and CAs. Operational factors (e.g., waste forms and containers, facility design, and waste receipts), closure plans, monitoring results, and research and development (R&D) activities were reviewed to determine the adequacy of the PAs. Likewise, the environmental restoration activities at the Nevada National Security Site (NNSS) (formerly the Nevada Test Site) relevant to the sources of residual radioactive material that are considered in the CAs, the land-use planning, and the results of the environmental monitoring and R&D activities were reviewed to determine the adequacy of the CAs.

54 ENVIRONMENTAL SCIENCES↗

UNCERTAINTIES OF ANION AND TOC MEASUREMENTS AT THE DWPF LABORATORY

The Savannah River Remediation (SRR) Defense Waste Processing Facility (DWPF) has identified a technical issue related to the amount of antifoam added to the Chemical Process Cell (CPC). Specifically, due to the long duration of the concentration and reflux cycles for the Sludge Receipt and Adjustment Tank (SRAT), additional antifoam has been required. The additional antifoam has been found to impact the melter flammability analysis as an additional source of carbon and hydrogen. To better understand and control the carbon and hydrogen contributors to the melter flammability analysis, SRR's Waste Solidification Engineering (WSE) has requested, via a Technical Task Request (TTR), that the Savannah River National Laboratory (SRNL) conduct an error evaluation of the measurements of key Slurry Mix Evaporator (SME) anions. SRNL issued a Task Technical and Quality Assurance Plan (TTQAP) [2] in response to that request, and the work reported here was conducted under the auspices of that TTQAP. The TTR instructs SRNL to conduct an error evaluation of anion measurements generated by the DWPF Laboratory using Ion Chromatography (IC) performed on SME samples. The anions of interest include nitrate, oxalate, and formate. Recent measurements of SME samples for these anions as well as measurements of total organic carbon (TOC) were provided to SRNL by DWPF Laboratory Operations (Lab OPS) personnel for this evaluation. This work was closely coordinated with the efforts of others within SRNL that are investigating the Chemical Process Cell (CPC) contributions to the melter flammability. The objective of that investigation was to develop a more comprehensive melter flammability control strategy that when implemented in DWPF will rely on process measurements. Accounting for the uncertainty of the measurements is necessary for successful implementation. The error evaluations conducted as part of this task will facilitate the integration of appropriate uncertainties for the measurements utilized in that control strategy. The flammability control strategy presented in relies on SME measurements of TOC and nitrate while one of the uses by WSE of the oxalate and formate measurement data will be the estimation of the amount of carbon coming from antifoam additions. The estimation is to be conducted by backing out contributions to the measured TOC concentration in the SME from the oxalate and the formate concentrations that are measured in the SME. The resulting adjusted TOC value will provide a basis for WSE to estimate the amount of antifoam that was added for that SME batch. The uncertainties of the oxalate, formate, and TOC measurements provided by the evaluations conducted as part of this task will allow for the propagation of their uncertainties into the estimated quantity of carbon coming from the added antifoam. The purpose of this technical report is to present the measurements generated by the DWPF Laboratory for recent SME batches, to conduct an evaluation of their uncertainties, and to provide the approach for propagating the uncertainties associated with these measurements into DWPF's strategies for controlling melter flammability and for monitoring antifoam additions. JMP Version 7.0.2 was used to support the analyses presented in this report.

08 HYDROGEN↗

GLYCOLIC-FORMIC ACID FLOWSHEET FINAL REPORT FOR DOWNSELECTION DECISION

Flowsheet testing was performed to develop the nitric-glycolic-formic acid flowsheet (referred to as the glycolic-formic flowsheet throughout the rest of the report) as an alternative to the nitric/formic flowsheet currently being processed at the DWPF. This new flowsheet has shown that mercury can be removed in the Sludge Receipt and Adjustment Tank (SRAT) with minimal hydrogen generation. All processing objectives were also met, including greatly reducing the Slurry Mix Evaporator (SME) product yield stress as compared to the baseline nitric/formic flowsheet. Forty-six runs were performed in total, including the baseline run and the melter feed preparation runs. Significant results are summarized. The baseline nitric/formic flowsheet run, using the SB6 simulant produced by Harrell was extremely difficult to process successfully under existing DWPF acceptance criteria with this simulant at the HM levels of noble metals. While nitrite was destroyed and mercury was removed to near the DWPF limit, the rheology of the SRAT and SME products were well above design basis and hydrogen generation far exceeded the DWPF SRAT limit. In addition, mixing during the SME cycle was very poor. In this sense, the nitric/glycolic/formic acid flowsheet represents a significant upgrade over the current flowsheet. Mercury was successfully removed with almost no hydrogen generation and the SRAT and SME products yield stresses were within process limits or previously processed ranges. The glycolic-formic flowsheet has a very wide processing window. Testing was completed from 100% to 200% of acid stoichiometry and using a glycolic-formic mixture from 40% to 100% glycolic acid. The testing met all processing requirements throughout these processing windows. This should allow processing at an acid stoichiometry of 100% and a glycolic-formic mixture of 80% glycolic acid with minimal hydrogen generation. It should also allow processing endpoints in the SRAT and SME at significantly higher total solids content and may be effective at acid stoichiometries below 100%, although no testing was performed below 100% acid stoichiometry. There are several issues related to the development of the glycolic-formic flowsheet. First, the measurement of anions using the new glycolate anion procedure likely needs to be optimized to improve the accuracy of the anions important to DWPF processing and REDOX prediction. Second, the existing REDOX equation with an added term for glycolate did not accurately predict the glass REDOX for the glycolic-formic flowsheet. Improvement of the anion measurement or modification of the REDOX methodology or equation may be necessary to improve the REDOX prediction. Last, the glycolic-formic flowsheet dissolves a number of metals, including iron. This leads to a thinner slurries but also dissolves up a portion of the iron, which is currently used for criticality control. It is recommended that DWPF continue to support development of the glycolic-formic flowsheet. This flowsheet meets or outperforms the baseline flowsheet in off-gas generation, mercury removal, product rheology and general ease of processing. Additional testing is in progress to demonstrate the effectiveness of the nitric-glycolic-formic flowsheet in processing a wide sludge processing window using the matrix sludge simulants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PARTITIONING OF GADOLINIUM IN THE CHEMICAL PROCESSING CELL

A combination of short-term beaker tests and longer-duration Sludge Receipt and Adjustment Tank (SRAT) simulations were performed to investigate the relative partitioning behaviors of gadolinium and iron under conditions applicable to the Chemical Processing Cell (CPC). The testing was performed utilizing non-radioactive simple Fe-Gd slurries, non-radioactive Sludge Batch 6 simulant slurries, and a radioactive real-waste slurry representative of Sludge Batch 7 material. The testing focused on the following range of conditions: (a) Fe:Gd ratios of 25-100; (b) pH values of 2-6; (c) acidification via addition of nitric, formic, and glycolic acids; (d) temperatures of {approx}93 C and {approx}22 C; and (e) oxalate concentrations of <100 mg/kg and {approx}10,000 mg/kg. The purpose of the testing was to provide data for assessing the potential use of gadolinium as a supplemental neutron poison when dispositioning excess plutonium. Understanding of the partitioning behavior of gadolinium in the CPC was the first step in assessing gadolinium's potential applicability. Significant fractions of gadolinium partitioned to the liquid-phase at pH values of 4.0 and below, regardless of the Fe:Gd ratio. In SRAT simulations targeting nitric and formic acid additions of 150% acid stoichiometry, the pH dropped to a minimum of 3.5-4.0, and the maximum fractions of gadolinium and iron partitioning to solution were both {approx}20%. In contrast, in a SRAT simulation utilizing a nitric and formic acid addition under atypical conditions (due to an anomalously low insoluble solids content), the pH dropped to a minimum of 3.7, and the maximum fractions of gadolinium and iron partitioning to solution were {approx}60% and {approx}70%, respectively. When glycolic acid was used in combination with nitric and formic acids at 100% acid stoichiometry, the pH dropped to a minimum of 3.6-4.0, and the maximum fractions of gadolinium and iron partitioning to solution were 60-80% and 3-5%, respectively. Thus, the presence of glycolic acid increased dissolution of gadolinium, but decreased dissolution of iron. In beaker tests, the fractions of gadolinium partitioning to solution were all less than the minimum detection limits at pH 6, on the order of a few percent at pH 4, and ranging from 70-90% at pH 2. In contrast, the fractions of iron partitioning to solution were all less than the minimum detection limits at pH 6, {le} 0.04% at pH 4, and {le} 0.9% at pH 2. A possible explanation for the small magnitude of these fractions (as compared to the fractions observed in the SRAT simulations) was incomplete equilibrium, due to the short duration (30 minutes) of the beaker tests. As demonstrated by the SRAT simulations, the typical partitioning equilibration time was on the order of hours. The Fe:Gd ratio appeared to impact the extent of liquid-phase conditions under certain conditions, although the exact relationship was not clear. Temperature impacts on the liquid-phase gadolinium concentrations were modest, with liquid phase concentrations typically increasing about 25% as temperatures rose from {approx}22 C to {approx}93 C. The presence of high concentrations of oxalate did not appear to change the liquid-phase gadolinium concentrations - however, it did increase the liquid-phase iron concentrations (from being undetectable to being detectable but still minor). Additional gadolinium partitioning testing is recommended. Of greatest usefulness will be SRAT simulations focusing on a wider range of acid addition scenarios and alternate sludge compositions, particularly those specific to future sludge batches where addition of excess plutonium is being considered.

54 ENVIRONMENTAL SCIENCES↗

SLUDGE WASHING AND DEMONSTRATION OF THE DWPF FLOWSHEET IN THE SRNL SHIELDED CELLS FOR SLUDGE BATCH 7A QUALIFICATION

Waste Solidification Engineering (WSE) has requested that characterization and a radioactive demonstration of the next batch of sludge slurry (Sludge Batch 7a*) be completed in the Shielded Cells Facility of the Savannah River National Laboratory (SRNL) via a Technical Task Request (TTR). This characterization and demonstration, or sludge batch qualification process, is required prior to transfer of the sludge from Tank 51 to the Defense Waste Processing Facility (DWPF) feed tank (Tank 40). The current WSE practice is to prepare sludge batches in Tank 51 by transferring sludge from other tanks. Discharges of nuclear materials from H Canyon are often added to Tank 51 during sludge batch preparation. The sludge is washed and transferred to Tank 40, the current DWPF feed tank. Prior to transfer of Tank 51 to Tank 40, SRNL simulates the Tank Farm and DWPF processes with a Tank 51 sample (referred to as the qualification sample). Sludge Batch 7a (SB7a) is composed of portions of Tanks 4, 7, and 12; the Sludge Batch 6 heel in Tank 51; and a plutonium stream from H Canyon. SRNL received the Tank 51 qualification sample (sample ID HTF-51-10-125) following sludge additions to Tank 51. This report documents: (1) The washing (addition of water to dilute the sludge supernate) and concentration (decanting of supernate) of the SB7a - Tank 51 qualification sample to adjust sodium content and weight percent insoluble solids to Tank Farm projections. (2) The performance of a DWPF Chemical Process Cell (CPC) simulation using the washed Tank 51 sample. The simulation included a Sludge Receipt and Adjustment Tank (SRAT) cycle, where acid was added to the sludge to destroy nitrite and reduce mercury, and a Slurry Mix Evaporator (SME) cycle, where glass frit was added to the sludge in preparation for vitrification. The SME cycle also included replication of five canister decontamination additions and concentrations. Processing parameters were based on work with a non-radioactive simulant. (3) Vitrification of a portion of the SME product and characterization and durability testing (as measured by the Product Consistency Test (PCT)) of the resulting glass. (4) Rheology measurements of the initial slurry samples and samples after each phase of CPC processing. This program was controlled by a Task Technical and Quality Assurance Plan (TTQAP), and analyses were guided by an Analytical Study Plan. This work is Technical Baseline Research and Development (R&D) for the DWPF. It should be noted that much of the data in this document has been published in interoffice memoranda. The intent of this technical report is bring all of the SB7a related data together in a single permanent record and to discuss the overall aspects of SB7a processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SCIX IMPACT ON DWPF CPC

A program was conducted to systematically evaluate potential impacts of the proposed Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) Chemical Processing Cell (CPC). The program involved a series of interrelated tasks. Past studies of the impact of crystalline silicotitanate (CST) and monosodium titanate (MST) on DWPF were reviewed. Paper studies and material balance calculations were used to establish reasonable bounding levels of CST and MST in sludge. Following the paper studies, Sludge Batch 10 (SB10) simulant was modified to have both bounding and intermediate levels of MST and ground CST. The SCIX flow sheet includes grinding of the CST which is larger than DWPF frit when not ground. Nominal ground CST was not yet available, therefore a similar CST ground previously in Savannah River National Laboratory (SRNL) was used. It was believed that this CST was over ground and that it would bound the impact of nominal CST on sludge slurry properties. Lab-scale simulations of the DWPF CPC were conducted using SB10 simulants with no, intermediate, and bounding levels of CST and MST. Tests included both the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) cycles. Simulations were performed at high and low acid stoichiometry. A demonstration of the extended CPC flowsheet was made that included streams from the site interim salt processing operations. A simulation using irradiated CST and MST was also completed. An extensive set of rheological measurements was made to search for potential adverse consequences of CST and MST and slurry rheology in the CPC. The SCIX CPC impact program was conducted in parallel with a program to evaluate the impact of SCIX on the final DWPF glass waste form and on the DWPF melter throughput. The studies must be considered together when evaluating the full impact of SCIX on DWPF. Due to the fact that the alternant flowsheet for DWPF has not been selected, this study did not consider the impact of proposed future alternative DWPF CPC flowsheets. The impact of the SCIX streams on DWPF processing using the selected flowsheet need to be considered as part of the technical baseline studies for coupled processing with the selected flowsheet. In addition, the downstream impact of aluminum dissolution on waste containing CST and MST has not yet been evaluated. The current baseline would not subject CST to the aluminum dissolution process and technical concerns with performing the dissolution with CST have been expressed. Should this option become feasible, the downstream impact should be considered. The main area of concern for DWPF from aluminum dissolution is an impact on rheology. The SCIX project is planning for SRNL to complete MST, CST, and sludge rheology testing to evaluate any expected changes. The impact of ground CST transport and flush water on the DWPF CPC feed tank (and potential need for decanting) has not been defined or studied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗