Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFLECTING TELESCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Examining the Angular Resolution of the Astro-H's Soft X-Ray Telescopes

The international x-ray observatory ASTRO-H was renamed Hitomi after launch. It covers a wide energy range from a few hundred eV to 600 keV. It is equipped with two soft x-ray telescopes (SXTs: SXT-I and SXT-S) for imaging the soft x-ray sky up to 12 keV, which focus an image onto the respective focal-plane detectors: CCD camera (SXI) and a calorimeter (SXS). The SXTs are fabricated in a quadrant unit. The angular resolution in half-power diameter (HPD) of each quadrant of the SXTs ranges between 1.1 and 1.4 arc min at 4.51 keV. It was also found that one quadrant has an energy dependence on the HPD. We examine the angular resolution with spot scan measurements. In order to understand the cause of imaging capability deterioration and to reflect it to the future telescope development, we carried out spot scan measurements, in which we illuminate all over the aperture of each quadrant with a square beam 8 mm on a side. Based on the scan results, we made maps of image blurring and a focus position. The former and the latter reflect figure error and positioning error, respectively, of the foils that are within the incident 8 mm x 8 mm beam. As a result, we estimated those errors in a quadrant to be approx. 0.9 to 1.0 and approx. 0.6 to 0.9 arc min, respectively. We found that the larger the positioning error in a quadrant is, the larger its HPD is. The HPD map, which manifests the local image blurring, is very similar from quadrant to quadrant, but the map of the focus position is different from location to location in each telescope. It is also found that the difference in local performance causes energy dependence of the HPD.

Astro-H/Hitomi; soft x-ray telescope; SXT; Wolter ↗

Observations of Phobos and Deimos with SpeX at NASA Infrared Telescope Facility

We measured near-infrared (NIR) reflectance spectra of Phobos and Deimos, using the prism (0.7–2.52 μm) and long-wavelength cross dispersed (LXD: 1.9–4.2 μm) modes of NASA Infrared Telescope Facility (IRTF)’s SpeX instrument. The goal of this study is to investigate the surface composition of Phobos and Deimos and search for any mineralogical absorption signatures that may be present on their surfaces, especially in the LXD spectral range. Prism spectra of Phobos showed significant slope variation at shorter wavelengths (λ <1.3 μm), which indicates surface heterogeneity possibly due to regolith’s composition and grain size, and/or space weathering. Deimos’ prism spectra were found to be consistent with the more red-sloped prism spectra of Phobos. The measured LXD spectra of Deimos revealed evidence of hydration with 3-μm band depths at 2.90 μm of 4–5%. The 3-μm band in Deimos could be attributed to exogenic sources such as solar wind implantation or OH-bearingimpactors, or to an endogenic source and the presence of carbonaceous material on its surface. Phobos’ andDeimos’ prism and LXD spectra, however, show no indications for absorption signatures of mafic silicates (i.e.,pyroxene, olivine), organics nor carbonates.

D Takir↗

Space Technology for Directly Imaging and Characterizing Exo-Earths

The detection of Earth-like exoplanets in the habitable zone of their stars, and their spectroscopic characteri- zation in a search for biosignatures, requires starlight suppression that exceeds the current best ground-based performance by orders of magnitude. The required planet/star brightness ratio of order 10-10 at visible wave-lengths can be obtained by blocking stellar photons with an occulter, either externally (a starshade) or internally (a coronagraph) to the telescope system, and managing diffracted starlight, so as to directly image the exoplanet in reflected starlight. Coronagraph instruments require advancement in telescope aperture (either monolithic or segmented), aperture obscurations (obscured by secondary mirror and its support struts), and wavefront error sensitivity (e.g. line-of-sight jitter, telescope vibration, polarization). The starshade, which has never been used in a science application, benefits a mission by being decoupled from the telescope, allowing a loosening of telescope stability requirements. In doing so, it transfers the difficult technology from the telescope system to a large deployable structure (tens of meters to greater than 100 m in diameter) that must be positioned precisely at a distance of tens of thousands of kilometers from the telescope. We describe in this paper a roadmap to achieving the technological capability to search for biosignatures on an Earth-like exoplanet from a future space telescope. Two of these studies, HabEx and LUVOIR, include the direct imaging of Earth-sized habitable exoplanets as a central science theme.

Crill, Brendan P.↗

Polarimeter for Low Energy X-ray Astrophysical Sources (PLEXAS)

The Polarimeter for Low Energy X-ray Astrophysical Sources (PLEXAS) is an astrophysics mission concept for measuring the polarization of X-ray sources at low energies below the C-K band (less than 277 eV). PLEXAS uses the concept of variations in the reflectivity of a multilayered X-ray telescope as a function of the orientation of an X-rays polarization vector with respect to the reflecting surface of the optic. By selecting an appropriate multilayer, and rotating the X-ray telescope while pointing to a source, there will be a modulation in the source intensity, as measured at the focus of the telescope, which is proportional to the degree of polarization in the source.

Murray, Stephen S.↗

Range Imaging without Moving Parts

Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected from the target would be focused by the receiver optical system onto an array of optical fibers matching the array in the transmitter. These optical fibers would couple the received light to one or more photodetector( s). Optionally, the receiver could include solid-state optical switches for choosing which optical fiber(s) would couple light to the photodetector(s). This instrument architecture is flexible and can be optimized for a wide variety of applications and levels of performance. For example, it is scalable to any number of pixels and pixel resolutions and is compatible with a variety of ranging and photodetection methodologies, including, for example, ranging by use of modulated (including pulsed and encoded) light signals. The use of fixed arrays of optical fibers to generate controlled illumination patterns would eliminate the mechanical complexity and much of the bulk of optomechanical scanning assemblies. Furthermore, digital control of the selection of the fiber-optic pathways for the transmitted beams could afford capabilities not seen in previous three-dimensional range-imaging systems. Instruments of this type could be specialized for use as, for example, proximity detectors, three-dimensional robotic vision systems, airborne terrain-mapping systems, and inspection systems.

Blair, J. Bryan↗

Ray-trace analysis of glancing-incidence X-ray optical systems

The results of a ray-trace analysis of several glancing-incidence X-ray optical systems are presented. The object of the study was threefold. First, the vignetting characteristics of the S-056 X-ray telescope were calculated using experimental data to determine mirror reflectivities. Second, a small Wolter Type I X-ray telescope intended for possible use in the Geostationary Operational Environmental Satellite program was designed and ray traced. Finally, a ray-trace program was developed for a Wolter-Schwarzschild X-ray telescope.

Foreman, J. W., Jr.↗

Advanced Al Mirrors Protected with LiF Overcoat to Realize Stable Mirror Coatings for Astronomical Telescopes

Pure Aluminum (Al) exhibits intrinsic high reflectance over the proposed Large UV/Optical/IR (LUVOIR) Surveyor observatory target spectral range (90-2500 nm). However, Al coatings have to be protected from oxygen exposure in order to prevent the formation of the naturally occurring Al2O3 oxide layer, which limit performance for use only above 160 nm. Aluminum protected with fluorides such as LiF or MgF2 have been the most commonly used solutions. But below 102 nm and down to 90 nm, no transparent material is available to protect Al and coating mirror reflectance stays below 40%. But even above 102 nm, the reflectance of protected Al is limited by the residual absorption of the fluoride overcoats. Hence, this paper will report on recent advances in producing enhanced Al-based mirror coatings with the highest possible far-ultraviolet (FUV) reflectance, while exhibiting a more stable LiF protection layer. The process starts with a bare optically smooth glass substrate that is coated with Al in an ultra-high vacuum chamber by using the physical vapor deposition (PVD) process, which has been shown to provide the best aluminum thin-films when compared to other approaches. The next step is done by in-situ exposure of the freshly made Al film to a reactive XeF2 gas that will grant a thin AlF3 overcoat (2-3 nm) to the Al film that prevents further oxidation. This fluorinated Al film is then coated with a final layer of a LiF metal-fluoride overcoat. The coating process is finalized with a second exposure to the XeF2 precursor gas. The preparation of these mirror coatings will be studied and analyzed as a function of the XeF2 exposure time and deposition rate of the LiF layer during the PVD process. This paper will present and discuss characterization of a number of Al+XeLiF witness coupons produced with this reactive PVD (rPVD) process. These studies include characterization of specular reflectance in the 90-2500 nm spectral range, micro-roughness, long-term stability, as well as polarization characteristics in the visible and near-infrared spectral regions. These studies have been performed in order to demonstrate the improved reflectance performance, longer durability, and less hygroscopic nature of protected Al mirrors produced with the rPVD process (through exposure to XeF2) and in comparison with the standard PVD process.

optics↗

Honeywell multispectral linear array (MLA) instrument design A system overview

In support of NASA's Experimental Land Observing System, a simple, reliable and relatively inexpensive multispectral linear array (MLA) instrument concept has been developed. The design satisfies requirements for multichannel radiometry and wide field imaging. A reflective off-axis anastigmat telescope is mounted in a highly strength-to-weight efficient truss structure, coupled to a solid beamsplitter assembly. Attention is given to the optical design of the MLA instrument, the telescope structure, the detector arrays, detector cooling, on-orbit calibration, signal processing electronics, the spacecraft interfaces, the modulation transfer function, the signal-to-noise ratio, radiometric accuracy, and spatial registration.

Eyring, D.↗

The Earth Radiation Budget (ERB) experiment - An overview

The development of ERB observational systems is traced from its beginnings in the late 1950's through to the current ERB on the Nimbus 7 satellite. The instruments comprising the current 22-channel ERB experiment are described in some detail. Noteworthy are the inclusion in one solar channel, of a self-calibrating cavity to measure the solar constant and the use of biaxial scanning telescopes to determine the angular reflection and emission model required for processing the narrow-angle radiometric data. A fairly detailed description of the prelaunch and in-flight calibrations is given along with an analysis of the radiometric performance of the instruments. The data processing system is traced with the aid of a schematic flow diagram showing the steps required to produce the many tape and microfilm products archived. Future plans for improving the quality and accuracy of the data products are discussed. Finally, the upcoming Earth Radiation Budget Experiment (ERBE) is briefly mentioned. It will be capable of simultaneously measuring the radiation budget from three satellites, each having a different equator crossing time and angle.

Jacobowitz, H.↗

A Near-Infrared Mapping Spectrometer for investigation of Jupiter and its satellites

The Near-Infrared-Mapping Spectrometer (NIMS) is one of the science instruments in the Galileo mission, which will explore Jupiter and its satellites in the mid-1990's. The NIMS experiment will map geological units on the surfaces of the Jovian satellites and characterize their mineral content; and, for the atmosphere of Jupiter, investigate cloud properties and the spatial and temporal variability of molecular abundances. The optics are gold-coated reflective and consist of a telescope and a grating spectrometer. The balance of the instrument includes a 17-detector (silicon and indium antimonide) focal plane array, a tuning fork chopper, microprocessor-controlled electronics, and a passive radiative cooler. A wobbling secondary mirror in the telescope provides 20 pixels in one dimension of spatial scanning in a pushbroom mode with 0.5 mr x 0.5 mr instantaneous field of view. The spectral range is 0.7-5.2 microns; resolution is 0.025 micron. NIMS is the first infrared experiment to combine both spatial and spectral mapping capability in one instrument.

Aptaker, Irving M.↗

The Solar/Stellar Coronal Explorer and the Solar/Stellar Coronal Observatory

The Solar/Stellar Coronal Explorer (SSCE) carries six identical Ritchey-Chretien Telescopes of 127 mm aperture each; their images will be recorded by multianode microchannel-array detectors. The mirrors of five of the telescopes are coated with multilayer reflecting structures that select narrow XUV wavelength bands corresponding to strong emission lines emitted by solar or stellar coronal plasmas. Also noted here is a larger explorer mission concept, that of the Solar/Stellar Coronal Observatory, which will undertake more extensive spectroscopic observations.

Walker, Arthur B. C., Jr.↗

Martian spectral units derived from ISM imaging spectrometer data

Based on results of the Viking mission, the soil layer of Mars has been thought to be fairly homogeneous and to consist of a mixture of as few as two components, a 'dark gray' basaltic material and a 'bright red' altered material. However, near-infrared reflectance spectra measured recently both telescopically and from spacecraft indicate compositional heterogeneity beyond what can be explained by just two components. In particular, data from the ISM imaging spectrometer, which observed much of the equatorial region at a spatial resolution of approximately 22 km, indicate spatial differences in the presence and abundance of Fe-containing phases, hydroxylated silicates, and H2O. The ISM data was used to define, characterize, and map soil 'units' based on their spectral properties. The spatial distribution of these 'units' were compared to morphologic, visible color, and thermal inertia features recognized in Viking data.

Murchie, S.↗

B-MINE: The Balloon-Borne Microcalorimeter Nuclear Line Explorer

B-MINE is a concept for a balloon mission designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the extent and velocity distribution of the 44Ti emitting region. The payload introduces the concept of focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics. B-MINE has a thin, plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3 sigma sensitivity in 10 (exp 6) s of 3.3 x 10(exp -7) ph cm(exp -2) s(exp -1) at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroid and width in CAS A.

Silver, E.↗

High-Resolution, Wide-Field-of-View Scanning Telescope

A proposed telescope would afford high resolution over a narrow field of view (<0.10 ) while scanning over a total field of view nominally 16 wide without need to slew the entire massive telescope structure. The telescope design enables resolution of a 1-m-wide object in a 50- km-wide area of the surface of the Earth as part of a 200-km-wide area field of view monitored from an orbit at an altitude of 700 km. The conceptual design of this telescope could also be adapted to other applications both terrestrial and extraterrestrial in which there are requirements for telescopes that afford both wide- and narrow-field capabilities. In the proposed telescope, the scanning would be effected according to a principle similar to that of the Arecibo radio telescope, in which the primary mirror is stationary with respect to the ground and a receiver is moved across the focal surface of the primary mirror. The proposed telescope would comprise (1) a large spherical primary mirror that would afford high resolution over a narrow field of view and (2) a small displaceable optical relay segment that would be pivoted about the center of an aperture stop to effect the required scanning (see figure). Taken together, both comprise a scanning narrow-angle telescope that does not require slewing the telescope structure. In normal operation, the massive telescope structure would stare at a fixed location on the ground. The inner moveable relay optic would be pivoted to scan the narrower field of view over the wider one, making it possible to retain a fixed telescope orientation, while obtaining high-resolution images over multiple target areas during an interval of 3 to 4 minutes in the intended orbit. The pivoting relay segment of the narrow-angle telescope would include refractive and reflective optical elements, including two aspherical mirrors, to counteract the spherical aberration of the primary mirror. Overall, the combination of the primary mirror and the smaller relay optic would provide narrow-angle, diffraction-limited high resolution at a wavelength of 500 nm.

Sepulveda, Cesar↗

New composite reflectance spectra of Mars from 0.4 to 3.14 micron

To verify the quality and accuracy of Phobos-2 Imaging Spectrometer for Mars (ISM) spectra of Mars, we have performed comparisons with telescopic data obtained contemporaneously and which have spatial and spectral overlap with the ISM measurements. We find general agreement between the independently-calibrated data sets in terms of spectral shape and absorption band strength and position in the 0.77 to 0.93 micron overlap region. The telescopic data were scaled to the ISM reflectance values in this overlap region to yield new bright and dark region composite reflectance spectra from 0.40 to 3.14 microns. We ascribe the increase in band depth and overall spectral heterogeneity of the ISM data relative to previous telescopic observations to the more than order of magnitude increase in spatial resolution achieved by ISM from Martian orbit. Further increases in spatial resolution from future orbital imaging spectroscopic instruments can be expected to reveal even greater degrees of compositional and mineralogic diversity on Mars.

Mustard, John F.↗

Suppressing Spurious Reflections In An Interferometer

Dynamic-aperture fringe discriminator is simple device enhancing operation of interferometer of spherical-wave-front type used to test lenses, telescopes, and other optical instruments. Device suppresses reflections from surfaces of refractive optical elements in instrument and/or test setup. Reflections from refractive optical components eliminated by blocking half of interferometer aperture.

Steimle, Lawrence J.↗

Compositional information for the Moon: Some characteristics of current near-IR spectra (telescopic and laboratory)

For the last decade telescopic near infrared spectra have been obtained for small lunar areas. Such spectra, with the ground truth foundation from lunar samples, have been used extensively to address a multitude of problems in lunar science. Much of the near infrared spectral reflectance data from both laboratory and telescopic measurements have recently been compiled in comparable formats and an initial comparative assessment of the available data using selected spectral parameters has been made. The objective is to develop a framework for the systematics of lunar near-IR spectra in order to better interpret spectra of unknown materials in terms of useful compositional information. Each spectrum was first classified according to its general character then a variety of parameters sensitive to mineralogy and alteration products were measured for each spectrum: band width, band strength, absorption band center near 1 micron, band symmetry, continuum slope, etc. The telescopic and laboratory data sets are briefly described. The comparative analysis shows that a few well known lunar spectral properties are evident in both sets, such as the systematic variation in pyroxene composition between the highlands and the mare. However, an additional gabbroic component can be detected in many highland craters.

Pieters, Carle M.↗